• Title/Summary/Keyword: DC21

Search Result 519, Processing Time 0.039 seconds

A Study on the Remain Life with Aging in 22kV CV cable (22kV 전력케이블의 열화 판정에 관한 연구)

  • Lee, Kwan-Woo;Mok, Young-Soo;Kim, Bo-Kyeong;Park, Bok-Ki;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.19-21
    • /
    • 2003
  • In this paper, we studied on life-decision of underground cable of live-lines state. As all equipments have been wear, underground cables decided design-life on the whole 30 years because underground cable have been occurred aging as time goes. CV cable has been become about 30 years after installation in the South Korea, is come to a important point of time with estimation about life. Study target cable is 22 kV CV cables in this point of view and installation cable is about 10 years before and behind. Measurement method used dc leakage method of live-lines state that applied voltage of 50V in neutral point and data is analyzing result that is measured during 5 years. In this result, insulation resistance could confirm that change according to season and cause is effect of humidity, seasons and load current. Also, according as data is gone aging, insulation resistance by Weibull distribution could confirm functionally its decrease. As a result, the aging speed of cable that water tree is gone could confirm fastness very. Numerical analysis result, cable that water tree is not gone could confirm that life of cable that has passed 10 years remains about $10{\sim}20$ years.

  • PDF

The Effect of Regenerative Energy Storage System on Stabilization of Electro-Pneumatic Braking Blending (회생에너지 저장시스템이 제동 브랜딩 안정화에 미치는 영향)

  • Kim, Kyu-Joong;Lee, Keun-Oh
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.5
    • /
    • pp.15-21
    • /
    • 2010
  • Regenerative Energy Storage System(ESS) is a system that saves regenerative energy which generated instantly in the regenerative braking of Electric Multiple Unit(EMU) and disappear, and reuse the stored energy when EMU is in powering. Such system related to a research field of renewable energy which emerged concerning climate change and high oil prices. In the case of existing domestic rolling stock, about 25% to 30% of generated regenerative energy is restored to power source and is regarded as direct factor of raising catenary voltage. Such rapid change of catenary voltage is a cause of the failure of EMU's electronic equipment and lowering its reliability and is also a cause of train's fault occurred by tripping circuit breaker. In this paper, we intend to investigate the effect on blending characteristics of electric-braking and pneumatic-braking whether the regenerative energy storage system is used or not in urban transit DC 1,500V feeding system, while trains run. And we also intend to investigate its effect on stabilization of the blending, fluctuation of catenary voltage and various electric equipments.

An ionic liquid incorporated gel polymer electrolyte for double layer capacitors

  • Perera, Kumudu S.;Prasadini, K.W.;Vidanapathirana, Kamal P.
    • Advances in Energy Research
    • /
    • v.7 no.1
    • /
    • pp.21-34
    • /
    • 2020
  • Energy storage devices have received a keen interest throughout the world due to high power consumption. A large number of research activities are being conducted on electrochemical double layer capacitors (EDLCs) because of their high power density and higher energy density. In the present study, an EDLC was fabricated using natural graphite based electrodes and ionic liquid (IL) based gel polymer electrolyte (GPE). The IL based GPE was prepared using the IL, 1-ethyl-3-methylimidazolium trifluoromethanesulfonate (1E3MITF) with the polymer poly(vinyl chloride) (PVC) and the salt magnesium trifluoromethanesulfonate (Mg(CF3SO3)2 - MgTF). GPE was characterized by electrochemical impedance spectroscopy (EIS), DC polarization test, linear sweep voltammetry (LSV) test and cyclic voltammetry (CV) test. The maximum room temperature conductivity of the sample was 1.64 × 10-4 Scm-1. The electrolyte was purely an ionic conductor and the anionic contribution was prominent. Fabricated EDLC was characterized by EIS, CV and galvanostatic charge discharge (GCD) tests. CV test of the EDLC exhibits a single electrode specific capacitance of 1.44 Fg-1 initially and GCD test gives 0.83 Fg-1 as initial single electrode specific discharge capacitance. Moreover, a good stability was observed for prolonged cycling and the device can be used for applications with further modifications.

Thermal Reliability Analysis of BLDC Motor in a High Speed Axial Fan by Numerical Method (수치해석에 의한 고속팬용 밀폐구조형 BLDC모터의 열신뢰성 분석)

  • Moon, Sun-Ae;Lee, Jae-Heon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.3
    • /
    • pp.130-138
    • /
    • 2010
  • The thermal reliability of the closed-type BLDC motor for the high speed axial fans is analyzed by a numerical method in this paper. Since the module and the motor part are combined in a closed case, the heat generated from a rotor in the motor and the electronic components in the PCB module can not be effectively removed to the outside. Therefore the module will easily fail by high temperature. The accelerated-life testing was accomplished to formulate the life equation and numerical method is used to predict the inside temperature of the PCB module, which is one of the life equation parameter according to the environment. When the environment temperature of BLDC motor is 21, 35 and 50 $^{\circ}C$, the temperature in the PCB space is predicted as 73.4, 87.5 and 102.4 $^{\circ}C$. Then the life time with the temperature are calculated as 2,239, 863 and 328 hours.

Polarographic Behavior of 1-(2-Thiazolylazo) 2-naphthol in Acetonitrile (아세토니트릴 溶媒중에서 1-(2-Thiazolylazo)-2-naphthol 의 폴라로그래프적 거동)

  • Zun Ung Bae;Moo Lyong Seo
    • Journal of the Korean Chemical Society
    • /
    • v.32 no.1
    • /
    • pp.15-21
    • /
    • 1988
  • The Polarographic behavior of 1-(2-thiazolylazo)-2-naphthol (TAN) in acetonitrile solution was studied. From the DC polarograms of TAN in acetonitrile solution, the type of reduction current and the effect of proton donor such as water have been investigated. In order to explain the reduction mechanism, the number of the electrons for each reduction step was measured by controlled potential coulometric technique and the electrolysis products were identified by UV-Vis spectroscopy and IR spectroscopy. The results were shown that the reduction of TAN in acetonitrile solution occurred with four-one electron steps. In addition, each reduction step was considerably reversible and the reduction current was diffusion controlled.

  • PDF

A Study on the Process Improvement of Commutator Press Fitting by 6 Sigma Process (6시그마 프로세스를 이용한 정류자(Commutator) 압입 공정개선에 관한 연구)

  • Cheong, Seon-Hwan;Choi, Seong-Dae;Yang, Se-Young
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.4 no.2
    • /
    • pp.37-42
    • /
    • 2005
  • Recently $6{\sigma}$ quality control is an most important strategy to many enterprises in order to be a top company in the world, because it is an excellent scientific method to achieve the best quality control for their management and products. SY company is a small and medium one that has the quality problem for a long time such as occurring cracks on the surface of commutator at his assembly line while being assembled a rotor shaft and commutator of DC motor. This research was started to improve this problem by $6{\sigma}$ process, and as the results of this study, first, to find three vital fews, second, to get an achievement of about 21% improvement for the fracture strength of commutator, and third, to be recognized to change into $6{\sigma}$ quality control in SY company.

  • PDF

Thick Metal CMOS Technology on High Resistivity Substrate and Its Application to Monolithic L-band CMOS LNAs

  • Kim, Cheon-Soo;Park, Min;Kim, Chung-Hwan;Yu, Hyun-Kyu;Cho, Han-Jin
    • ETRI Journal
    • /
    • v.21 no.4
    • /
    • pp.1-8
    • /
    • 1999
  • Thick metal 0.8${\mu}m$ CMOS technology on high resistivity substrate(RF CMOS technology) is demonstrated for the L-band RF IC applications, and we successfully implemented it to the monolithic 900 MHz and 1.9 GHz CMOS LNAs for the first time. To enhance the performance of the RF circuits, MOSFET layout was optimized for high frequency operation and inductor quality was improved by modifying the technology. The fabricated 1.9 GHz LNA shows a gain of 15.2 dB and a NF of 2.8 dB at DC consumption current of 15mA that is an excellent noise performance compared with the offchip matched 1.9 GHz CMOS LNAs. The 900 MHz LNA shows a high gain of 19 dB and NF of 3.2 dB despite of the performance degradation due to the integrating of a 26 nH inductor for input match. The proposed RF CMOS technology is a compatibel process for analog CMOS ICs, and the monolithic LNAs employing the technology show a good and uniform RF performance in a five inch wafer.

  • PDF

Traditional Knowledge of Plants Used for River Fishing in Local Communities of North Jeolla Province, Korea (전북 지역사회에서 천렵에 이용된 식물들의 전통지식에 관한 연구)

  • Cheon, Inok;Song, Mi-Jang;Kim, Hyun;Lee, Ki Hoon;Yoo, Young Joon
    • The Korean Journal of Community Living Science
    • /
    • v.26 no.4
    • /
    • pp.675-681
    • /
    • 2015
  • This study investigates traditional knowledge of plants used for river fishing in local communities of North Jeolla Province, Korea. Data were collected using the participatory rural appraisal method based on interviews, informal meetings, open and group discussions, and overt observations with semi-structured questionnaires. Field investigations were conducted at 19 sites from July 2008 to April 2010. Interviews included 37 key informants (16 men and 21 women) who lived more than 50 years in the area. The average age of the informants was 83 (range = 60 to 96). The analysis recorded seven species, namely Albizia julibrissin Durazz., Juglans mandshurica Maxim., Perilla frutescens var. japonica (Hassk.) H. Hara, Nelumbo nucifera Gaertn., Persicaria hydropiper (L.) Spach, Zanthoxylum piperitum (L.) DC., and Styrax japonicus Siebold and Zucc..

Development of a Hydrostatic Guideway Driven by the Linear Motor (리니어모터를 이용한 초정밀 유정압안내면 개발)

  • 박천홍;황주호;오윤진;이찬홍
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.343-346
    • /
    • 2003
  • In order to discuss the availability of the hydrostatic guideway driven by the coreless linear motor to ultra precision machine tools, a prototype of guideway is designed and tested in this research. A coreless linear DC motor with the continuous force of 156 N and a laser scale with the resulution of 10 nm are used as the feeding system. The experiments are performed on the static stiffness. motion accuracy, positioning accuracy. microstep response and variation of velocity. The guideway has the infinite axial stiffness within 50 N of applied load, and has 0.08 ${\mu}{\textrm}{m}$ of linear motion error and 0.1 arcsec of angular motion error. It also has 0.21 ${\mu}{\textrm}{m}$ of positioning error and 0.09 ${\mu}{\textrm}{m}$ of repeatability, and it shows the stable response against the 10 nm resolution step command. The velocity variation of feeding system is less than 5%. From these results, it is confirmed that the hydrostatic guideway driven by the coreless linear motor is very useful for the ultra precision machine tools.

  • PDF

Study of Multi-Walled Carbon Nanotube Synthesis Using Liquid Nitrogen and Post-Process Filtration

  • Sornsuwit, Nuttaphong;Maaithong, Worawut
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.3
    • /
    • pp.18-21
    • /
    • 2008
  • The study deals with the effects of parameters in the synthesis of carbon nanotubes in liquid nitrogen to find the most appropriate conditions such as electrical voltage and time that give carbon nanotubes with large volume and less proportion of impurity, which is a non-nanotubed carbon. The experiment employed the method of arc-discharge between graphite cathode and anode which are immersed in liquid nitrogen. The electrical DC current of 60A and 70A were applied with the time period ranging from 10 seconds to 25 seconds. It was found that the electrical current of 60A and 13 seconds arc-discharge time allowed the largest volume of carbon nanotubes generation. The longer time leads to more impurities around the carbon nanotubes. By the filtration of CNTs-suspended solution using 0.2 micrometers porous paper filter and the characterization using TEM, the carbon nanotubes synthesized in the study were approximately 25 layers multi-walled nanotubes with the average diameter of 18.2 nanometers.