• Title/Summary/Keyword: DC-LED

Search Result 210, Processing Time 0.026 seconds

Comparative Analysis of Nurse-led Health Care in Child Daycare Centers (어린이집 방문간호사의 직무에 대한 인식비교)

  • Oh, Won-Oak;Im, YeoJin;Park, Ihnsook;Lee, Anna;Suk, Min Hyun
    • Journal of Korean Public Health Nursing
    • /
    • v.37 no.1
    • /
    • pp.25-40
    • /
    • 2023
  • Purpose: To compare perceptions of nurse-led health care visits in child daycare centers and calculate determination coefficients (DC) reflecting the job values. Methods: This was a secondary analysis study that applied the evaluation report for visiting nursing services for child daycare centers, prepared by the Seoul Nurses Association in 2021. Totally, 86 visiting nurses, 1997 childcare teachers, and 1915 parents were included in the study. The job recognition questionnaire was used to identify the levels of readiness, importance, and difficulty of a visiting nurse's job. Results: The visiting nurses showed high levels of readiness and importance for most duties and tasks expected of them. Compared to the nurses, the parents determined a greater importance towards the jobs of visiting nurses. The visiting nurses and childcare teachers exhibited similar levels of importance for the job. The highest and lowest DC scores were obtained for 'child developmental evaluation and referral' and 'child education', respectively. Conclusion: The duties and tasks verified in this study can be evidence for the job description, and should be preferentially developed for enhancing the competency of visiting nurses. Considering the importance of nurse-led health care, this will warrant an expansion of services to other regions.

Differentiation Induction of Dendritic Cell Phenotypes from Human Leukemic Cell Lines

  • Lee, Dae-Heui;Park, Jae-Sun;Eo, Wan-Kyu;Kim, Woo-Mi;Kang, Koo-Il
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.5 no.1
    • /
    • pp.79-86
    • /
    • 2001
  • Recent clinical studies have shown that a high proportion of patients with acute promyelocytic leukemia (APL) achieve complete remission after treatment with all-trans retinoic acid (ATRA). However, most patients who receive continuous treatment with ATRA relapse and develop ATRA-resistant leukemia. Dendritic cells (DCs) are important antigen-presenting cells in the development of antileukemic T-cell responses. In this study, we investigated the strategies to overcome ATRA resistance of APL cells by inducing the differentiation of DCs from human leukemic cell lines for the developtment of adoptive immunotherapy. CD83 was used as a mature DC marker in this study and the expression of CD83 mRNA was determined by RT-PCR method. The promyelocytic leukemic cell line HL-60, B lymphoblast cell lines RPMI 7666 and NC-37 could be induced to dendritic cells in vitro. Treatment of HL-60 with phorbol 12-myristate 13-acetate (PMA) resulted in the expression of myeloid-related DC phenotypes, while treatment of RPMI 7666 with fms-like tyrosine kinase 3 ligand (Flt3-ligand, FL) and treatment of NC-37 with PMA and FL led to the expression of lymphoid-related DC phenotypes. In conclusion, myeloid-related DC phenotypes and lymphoid-related DC phenotypes could be generated from HL-60, NC-37 and RPMI 7666 cell lines, respectively. These DC phenotypes can potentially be used to generate antileukemic T cells in vitro for adoptive immunotherapy.

  • PDF

Design and Fabrication of 1.2GHz range RF Transmitter and Receiver for Bi-directional Capsule Endoscopes (양방향 캡슐형 내시경용 1.2GHz 대역 RF 송수신기 설계 및 제작)

  • 장경만;문연관;류원열;윤영섭;조진호;최현철
    • Proceedings of the IEEK Conference
    • /
    • 2003.11c
    • /
    • pp.81-85
    • /
    • 2003
  • The Bi-directional Wireless Capsule endoscope con sists of CMOS Image sensor, FPGA, LED, Battery, DC to DC Converter, Transmitter, Receiver and Antennas. The RF transmitter at 1.2GHz range is designed and fabricated with 10 mm(diameter)x1.6 mm(thickness) dimension considering the maximum permission exposure(MPE), system size, power consumption, linearity and modulation method. The fabricated RF receiver at 400MHz range can demodulate the external signals so as to control the behavior of CMOS image sensor. four LEDs and Transmitter.

  • PDF

Luminous efficacy according to operating voltages of high flux RGB LEDs (고출력 RGB 발광다이오드의 구동전압에 따른 발광효율 비교)

  • Song, Sang-Bin;Kwon, Yong-Seok;Im, Sung-Mu;Yeo, In-Seon
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1710-1712
    • /
    • 2003
  • This paper analyzes the effects of various operating voltages on the luminous efficacy of high flux RGB LEDs. At first, their equivalent diode model are established from measurements of the V-I characteristics. Operating voltages of three types are applied to a simple LED circuit: DC, square-wave, and full-wave-rectified sine wave. As the result, DC voltage driving gives the hightest efficiency, but invokes much greater variation in the luminous flux and more shift in the peak wavelength.

  • PDF

An Efficient High Voltage Level Shifter using Coupling Capacitor for a High Side Buck Converter

  • Seong, Kwang-Su
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.125-134
    • /
    • 2016
  • We propose an efficient high voltage level shifter for a high side Buck converter driving a light-emitting diode (LED) lamp. The proposed circuit is comprised of a low voltage pulse width modulation (PWM) signal driver, a coupling capacitor, a resistor, and a diode. The proposed method uses a property of a PWM signal. The property is that the signal repeatedly transits between a low and high level at a certain frequency. A low voltage PWM signal is boosted to a high voltage PWM signal through a coupling capacitor using the property of the PWM signal, and the boosted high voltage PWM signal drives a p-channel metal oxide semiconductor (PMOS) transistor on the high side Buck converter. Experimental results show that the proposed level shifter boosts a low voltage (0 to 20 V) PWM signal at 125 kHz to a high voltage (370 to 380 V) PWM signal with a duty ratio of up to 0.9941.

A Novel Switching Mode for High Power Factor Correction and Low THD

  • Park, Gyumin;Eum, Hyunchul;Yang, Seunguk;Hwang, Minha;Park, Inki
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.210-212
    • /
    • 2018
  • A new switching mode has been proposed to obtain high power factor and low THD in single stage AC-DC converter. The conventional voltage mode control in critical conduction mode distorts input current shape with poor THD in flyback topology. Once TRIAC dimmer is connected, visible flicker in the LED lamp is easily detected due to a lack of TRAIC holding current near the input voltage zero cross. The newly proposed method can shape the input current by providing a desired reference voltage so that low THD is obtained by ideal sinusoidal input current in case of no dimmer connection and flat input current performs good TRIAC dimmer compatibility in phase-cut dimming condition. To confirm the validity of the proposed method, theoretical analysis and experimental result from 8W dimmable LED lighting system are presented.

  • PDF

Flyback AC-DC Converter with Low THD Based on Primary-Side Control

  • Chang, Changyuan;He, Luyang;Cao, Zixuan;Zhao, Dadi
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1642-1649
    • /
    • 2018
  • A single-stage flyback LED AC-DC converter based on primary-side control under constant current mode is proposed in this study. The proposed converter features low total harmonic distortion (THD) and high power factor (PF). It also consists of a zero-crossing distortion compensation circuit and a variable duty ratio control compensation circuit to deal with the line current distortions caused by fixed duty ratio control. The system model and layout are built in Simplis and Cadence, respectively. The feasibility and performance of the proposed circuit is verified by designing and fabricating an IC controller in the HHNEC $0.35{\mu}m$ 5 V/40 V HVCMOS process. Experimental results show that the PF can reach a level in the range of 0.985-0.9965. Moreover, the average THD of the entire system is approximately 10%, with the minimum being 6.305%, as the input line voltage changes from 85 VAC to 265 VAC.

Parameter Calculation of HPF Single Phase Boost Converter Operated by Variable Hysteretic Current Mode Control (가변밴드폭 전류 연속모드로 동작하는 고역률 단상 Boost Converter의 파라메타 산정에 관한 연구)

  • Yun, Byung-Han;Kwon, Soon-Jae;Yoo, Dong-Wook;Kim, Cheul-U
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.1038-1040
    • /
    • 1993
  • Single phase AC to DC Boost-converter which is control led with a variable hysteretic current mode for improvent of input power factor makes high power factor possible. Power Factor correction circuit can be identified with a determination of each parameters. A simaluation and experiment result to load and parameter variation is examined.

  • PDF

Evaluation of Particle Counting by Smartphone-based Fluorescence Smartscope and Particle Positioning in Spinning Helical Channel (스마트폰 기반 형광 smartscope의 입자계수 및 회전하는 나선형 채널의 입자정렬 성능 평가)

  • Park, Eunjung;Kim, Subin;Cho, Myoung-Ock;Kim, Kyunghoon;Shourav, Mohiuddin Khan;Kim, Sunwook;Lee, Jeonghoon;Kim, Jung Kyung
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.20 no.3
    • /
    • pp.19-28
    • /
    • 2015
  • With the aim of developing a smartphone-based point-of-care device that is small, inexpensive, and easy to handle by non-expert, we designed a fluorescence smartscope for counting particles and a DC motor-controlled particle positioning system. Our smartscope can count the number of fluorescent particles and fluorescently-stained white blood cells through a phone camera with an adaptor containing a LED, a ball lens and optical filters and an application running on a smartphone. The motor was controlled wirelessly via Bluetooth with an Android smartphone. We found that axial spinning of a helical microfluidic channel allows arrangement of particles having size similar to the white blood cells. The motor-controlled particle positioning system can minimize time-consuming manual processes and automate sample preparation process and thus, if integrated with the smartscope, it can be used for a point-of-care testing device based on a smartphone.

High-temperature oxidation resistance of Ti-Si-N coating layers prepared by DC magnetron sputtering method (DC magnetron sputtering법으로 제조된 Ti-Si-N코팅막의 내산화성에 관한 연구)

  • Choi, Jun-Bo;Ryu, Jung-Min;Cho, Gun;Kim, Kwang-Ho;Lee, Mi-Hye
    • Journal of the Korean institute of surface engineering
    • /
    • v.35 no.6
    • /
    • pp.415-421
    • /
    • 2002
  • Ti-Si-N coating layers were codeposited on silicon wafer substrates by a DC reactive magnetron sputtering technique using separate titanium and silicon targets in $N_2$/Ar gas mixtures. The oxidation behavior of Ti-Si-N coating layers containing 4.0 at.%, 10.0 at.%, and 27.3 at.% Si was investigated at temperatures ranging from 600 to $960^{\circ}C$. The coating layers containing 4.0 at.% Si became fast oxidized from $600^{\circ}C$ while the coating layers containing 10.0 at.% Si had oxidation resistance up to $800^{\circ}C$. It was concluded that an increase in Si content to a level of 10.0 at.% led to the formation of finer TiN grains and a uniformly distributed amorphous Si3N4 phase along grain boundaries, which acted as efficient diffusion barriers against oxidation. However, the coating layers containing 27.3 at.% Si showed relatively low oxidation resistance compared with those containing 10.0 at.% Si. This phenomenon would be explained by the existence of free Si which was not nitrified in the coating layers containing 27.3 at.% Si.