• 제목/요약/키워드: DC stress

검색결과 490건 처리시간 0.026초

DC 전압이 유입변압기 절연시스템에 미치는 영향에 관한 연구 (Study on the effect of DC voltage in oil-immersed transformer insulation system)

  • 장효재;김용한;석복렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1552-1553
    • /
    • 2011
  • The HVDC transformer which is one of the main equipments for HVDC(High Voltage Direct Current) electric power transmission systems is exposed to not only AC voltage but also the inflowing DC voltage which comes from the DC-AC converter systems. Therefore, the HVDC transformer insulation system is required to withstand the electric field stress under AC, DC and DC polarity reversal conditions. However the electric field distributions under those conditions are different because the AC electric field and DC electric field are governed by permittivity and conductivity, respectively. In this study, the changes of electric potential and electric field of conventional AC transformer insulation system under DC polarity reversal test condition were analyzed by FEM(Finite Element Method). The DC electric field stress was concentrated in the solid insulators while the AC electric field stress was concentrated in the mineral oil. In addition, the electric stress under that condition which is affected by the surface charge accumulation at the interfaces between insulators was evaluated. The stress in some parts could be higher than that of AC and DC condition, during polarity reversal test. The result of this study would be helpful for the HVDC transformer insulation system design.

  • PDF

넓은 입력 전압 범위와 감소된 스트레스 전압 기능성을 갖는 새로운 승압형 멀티레벨 DC-DC 컨버터 (A New Multi Level High Gain Boost DC-DC Converter with Wide Input Voltage Range and Reduced Stress Voltage Capability)

  • 이바둘라예브 안바르;박성준
    • 전력전자학회논문지
    • /
    • 제25권2호
    • /
    • pp.133-141
    • /
    • 2020
  • The use of high-gain-voltage step-up converters for distributed power generation systems is being popularized because of the need for new energy generation and power conversion technologies. In this study, a new constructed high-gain-boost DC-DC converter was proposed to coordinate low voltage output DC sources, such as PV or fuel cell systems, with high DC bus (380 V) lines. Compared with traditional boost DC-DC converters, the proposed converter can create higher gain and has wider input voltage range and lower voltage stress for power semiconductors and passive elements. Moreover, the proposed topology produces multilevel DC voltage output, which is the main advantage of the proposed topology. Steady-state analysis in continuous conduction mode of the proposed converter is discussed in detail. The practicability of the proposed DC-DC converter is presented by experimental results with a 300 W prototype converter.

전압 스트레스와 맥동이 개선된 양극성 출력 전압을 갖는 LCCT Z-소스 DC-DC 컨버터 (LCCT Z-Source DC-DC Converter with the Bipolar Output Voltages for Improving the Voltage Stress and Ripple)

  • 박종기;신연수;정영국;임영철
    • 전력전자학회논문지
    • /
    • 제18권1호
    • /
    • pp.91-102
    • /
    • 2013
  • This paper proposes the improved LCCT(Inductor-Capacitor-Capacitor-Trans) Z-source DC-DC converter (Improved LCCT ZSDC) which can generate the bipolar output voltages according to duty ratio D. The proposed converter has the characteristic and structure of Quasi Z-source DC-DC converter(Quasi ZSDC) and conventional LCCT Z-source DC-DC converter(LCCT ZSDC). To confirm the validity of the proposed method, PSIM simulation and a DSP based experiment were performed for each converter. In case which the input DC voltage is 70V, the bipolar output DC voltage of positive 90V and negative 50V could generate. Also, as comparison result of the capacitor voltage ripple in Z-network and the input current under the same condition for each converter, the voltage stress and the capacitor voltage in Z-network of the proposed method were lower compared with the conventional methods. Finally, the efficiency for each method was investigated according to load variation and duty ratio D.

Pr6O1계 ZnO 바리스터의 DC 가속열화 스트레스에 따른 전기적, 유전적 거동에 미치는 소결온도의 영향 (Effect of Sintering Temperature on Electrical and Dielectric Behavior of Pr6O1-Based ZnO Varistors with DC Accelerated Aging Stress)

  • 남춘우;정영철;김향숙
    • 한국전기전자재료학회논문지
    • /
    • 제15권3호
    • /
    • pp.244-252
    • /
    • 2002
  • The electrical and dielectric behavior fort DC accelerated aging stress of P $r_{6}$ $O_{11}$-based Zno varistors cnsisting of ZnO-P $r_{6}$ $O_{11}$-CoO-C $r_2$ $O_3$-E $r_2$ $O_3$ were investigated with sintering temperature in the range of 1325~1345$^{\circ}C$. The varistor ceramics with increasing sintering temperature were more densified. A more densified varistors leaded to high stability for DC accelerated aging stress. Furthermore, the stability for DC accelerated aging stress was increased with the leakage current and dtan $\delta$/dV decreasing in order of 1325longrightarrow1335longrightarrow1345longrightarrow134$0^{\circ}C$ in sintering temperature. It was found that the stability for DC stress is affected more greatly by the leakage current and dtan $\delta$/dV than the densification. It is considered that the stability of varistors for DC stress can be estimated by considering the factors, such as the densification, leakage current, and dtan $\delta$/dV. As a result, the varistor sintered at 134$0^{\circ}C$ exhibited the highest stability, with %$\Delta$ $V_{lmA}$=-1.54%, %$\Delta$$\alpha$=-2.49%, %$\Delta$ $I_{\ell}$=+240.68%, 5%$\Delta$tan$\delta$=+29.96%.96%.96%.%.

dc/dc 컨버터의 스위칭 소자의 전압 스트레스 (Voltage Stress of Switching Device in dc/dc Converter)

  • 마근수;최진호;김양모
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.1019-1021
    • /
    • 1992
  • This paper deals with the stress of the converters using the resonant switches. It is represented the reduction of the voltage and current stresses. According to the configuration of the multiple poly-phase converter. Especially, about buck ZVS-QRC it is studied the reduction of the voltage stress, and represented the result of simulation.

  • PDF

Hot Carrier Stress로 인한 SOI MOSFET의 전력 성능 저하 (Effect of Hot Carrier Stress on The Power Performance Degradation in SOI MOSFET)

  • 이병진;박성욱;박종관
    • 전자공학회논문지 IE
    • /
    • 제45권4호
    • /
    • pp.7-10
    • /
    • 2008
  • 본 연구에서는 load-pull 장비를 이용하여 hot carrier 현상에 따른 RF 전력 성능 저하를 측정 분석하였다. 스트레스를 인가한 주에 RF 전력 지수들은 감소하였으며, 고정 전압 조건에서 관찰한 SOIl MOSFET의 DC 성능 지수들 또한 hot carrier stress로 인하여 감소함을 할 수 있었다. 또한 Hot carrier stress로 인한 DC 성능 저하로 인하여 RF 전력 성능 저하의 감소를 알 수 있었다.

열적 stress에 의한 폴리이미드 표면에서의 TN-LCD의 잔류DC 특성 (Residual DC characteristic on Twisted Nematic Liquid Display on the Polyimide Surface by the Thermal Stress)

  • 배유한;황정연;김종환;문현찬;한정민;김영환;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.498-501
    • /
    • 2004
  • In this study, the threshold voltage and the response time of thermal stressed TN-LCDs showed the same performances on no thermal stressed TN-LCDs. There was little change of value in TN cells. Also, the transmittances of TN-LCDs on the rubbed PI surface were almost same while increasing thermal stress time. However, the thermal stability of TN cell was decreased by the high thermal stress for the long duration. Residual DC was decreased as the thermal stress increases. Especially, when TN cell was stressed more and more by heating, residual DC was changed a lot. As a result, the residual DC property of LCD in projection TV is affected very much by heating.

  • PDF

Minimization of Voltage Stress across Switching Devices in the Z-Source Inverter by Capacitor Voltage Control

  • Tran, Quang-Vinh;Chun, Tae-Won;Kim, Heung-Gun;Nho, Eui-Cheol
    • Journal of Power Electronics
    • /
    • 제9권3호
    • /
    • pp.335-342
    • /
    • 2009
  • The Z-source inverter (ZSI) provides unique features such as the ability to boost dc voltage with a single stage simple structure. Although the dc capacitor voltage can be boosted by a shoot-through state, the voltage stress across the switching devices is rapidly increased, so high switching device power is required at the ZSI. In this paper, algorithms for minimizing the voltage stress are suggested. The possible operating region for obtaining a desired ac output voltage according to both the shoot-through time and active state time is investigated. The reference capacitor voltages are derived for minimizing the voltage stress at any desired ac output voltage by considering the dc input voltage. The proposed methods are carried out through the simulation studies and experiments with 32-bit DSP.

A Forward-Integrated Buck DC-DC Converter with Low Voltage Stress for High Step-Down Applications

  • Adivi, Maedeh Ghanbari;Yazdani, Mohammad Rouhollah
    • Journal of Power Electronics
    • /
    • 제18권2호
    • /
    • pp.356-363
    • /
    • 2018
  • The combination of a buck converter and a forward converter can be considered to accomplish a high step-down non-isolated converter. To decrease the insufficient step-down ratio of a regular buck converter and to distribute switch voltage stress, a forward-integrated buck (FIB) converter is proposed in this paper. The proposed interleaved DC-DC converter provides an additional step-down gain with the help of a forward converter. In addition to its simple structure, the transformer flux reset problem is solved and an additional magnetic core reset winding is not required. The operational principle and an analysis of the proposed FIB converter are presented and verified by experimental results obtained with a 240 W, 150 V/24 V prototype.

영구거푸집으로 활용한 탄소섬유 FRP 판과 DFRCC 사이의 부착응력에 관한 실험적 연구 (An Experimental Study for Bond Stress between DFRCC and Carbon FRP Plank Used as a Permanent Formwork)

  • 박찬영;유승운
    • 대한토목학회논문집
    • /
    • 제34권6호
    • /
    • pp.1687-1694
    • /
    • 2014
  • 최근 들어 탄소섬유 FRP가 보수/보강재로 많이 활용되고 있다. 본 연구에서는 탄소섬유 FRP 판을 영구 거푸집으로 활용하여 새로운 콘크리트 교량 바닥판 시스템을 개발하기 위하여 CFRP판과 고인성 섬유보강 콘크리트 사이의 부착성능에 대한 평가를 실시하였다. 현장타설 콘크리트와 CFRP 간에 부착을 높이기 위하여 시중에 유통되는 에폭시를 사용하여 규사를 부착하였다. 일반콘크리트의 부착응력은 2.11~5.43MPa으로 나타났고, 고인성 섬유보강 콘크리트인 DC1 (RF4000)과 DC2 (PP)의 부착응력은 각각 3.91~5.60MPa, 2.92~5.21MPa이며, DC3 (RF4000+RSC15)의 부착응력은 4.80~5.58MPa, DC4 (PP+RSC15)의 평균 부착응력은 5.57~5.89MPa으로 나타났다.