• 제목/요약/키워드: DC power

검색결과 6,492건 처리시간 0.035초

연속 공정 PVD 방법에 의한 Coated Conductor 제조 (Fabrication of Coated Conductor by Continuous PVD Methods)

  • 고락길;정준기;김호섭;하홍수;;송규정;박찬;유상임;문승현;김영철
    • 한국전기전자재료학회논문지
    • /
    • 제17권11호
    • /
    • pp.1241-1245
    • /
    • 2004
  • Continuous physical vapor deposition (PVD) method is one of many processes to fabricate long length coated conductor which is required for successful large-scale application of superconducting power devices. Three film deposition systems (pulsed laser deposition, sputtering, and evaporation) equipped with reel-to-reel(R2R) metal tape moving apparatus were installed and used to deposit multi-layer oxide thin films. Both RABiTS and IBAD texture templates are used. IBAD template consists of CeO$_2$(PLD)/YSZ(IBAD) on stainless steel(SS) metal tape, and RABiTS template has the structure of CeO$_2$/YSZ/Y$_2$O$_3$ which was continuously deposited on Ni-alloy tape using R$_2$R evaporation and DC reactive sputtering in a deposition system designed to do both processes. 0.4 m-long coated conductor with Ic(77 K) of 34 A/cm was fabricated using RABiTS template. 0.5 m and 1.1 m-long coated conductor with Ic(77 K) of 41 A/cm and 26 A/cm were fabricated using IBAD template.

성막직전 기판 열처리가 롤투롤 스퍼터를 이용하여 성장시킨 터치 패널용 ITO 투명 전극의 특성 미치는 효과 연구

  • 김동주;김봉석;김한기
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.416-416
    • /
    • 2010
  • 본 연구에서는 저가격, 대면적화를 위한 롤투롤 스퍼터를 설계&개발하고, 성막직전 PET 기판의 열처리 유무를 통한 ITO 박막을 성막 시킨 저항막 방식의 터치 패널용 투명 전극에 대하여 전기적, 광학적, 구조적, 표면적 특성을 분석하였다. 롤투롤 스퍼터는 degassing챔버와 스퍼터 챔버가 한 시스템에 구성되었고, Degassing 챔버는 좌우측의 Rewinder/Unwinder 롤러에 의해 감고 풀어지는 PET기판의 수분 및 가스를 중앙부에 위치한 히터를 통해 제거하며, 수분 제거 후 스퍼터 챔버로 옮겨진 1250 mm폭의 PET기판을 Unwinder/Rewinder 롤러에 장착하며, Unwinder 롤러로부터 풀려진 PET 기판은 guide 롤러를 거쳐 cooling drum과의 물리적 접촉에 의해 PET 기판의 냉각이 일어나게 된다. ITO 캐소드 전에 장착된 할로겐 히터 상부로 기판이 지나가면서 열처리가 진행되고 열처리 후 두 개의 ITO 캐소드 상부를 지나면서 연속적으로 ITO 박막이 PET 기판에 성막 되게 된다. ITO 박막의 주요 성막 변수인 DC Power, Ar/$O_2$ 가스 유량비, 기판의 속도는 최적으로 고정하고, 성막 직전 기판의 열처리에 유무에 따른 ITO박막의 필름을 각각 고온 챔버에서 $140^{\circ}C{\times}90min$ 동안 열처리를 통한 내열성 테스트를 진행하여 ITO 필름의 특성 향상을 비교 분석하였다. 분석을 위해 전기적 특성은 four-point probe로 측정했고, 투과도는 Nippon Denshoku사(社)의 COH-300A를 이용해 가시광(550nm)에서 분석했고, FE-SEM으로 ITO박막 의 표면 상태를 분석하였다. 또한 Bending Tester(Z-100)를 이용하여 기계적 안정성을 분석하였다. 성막직전 PET 기판의 열처리를 하지 않은 ITO박막은 고온의 챔버 에서 $140^{\circ}C{\times}90min$ 동안 내열성 테스트 후 면저항이 511($\omega/\Box$)에서 630($\omega/\Box$)으로 높아졌으나, 성막직전 열처리를 통한 ITO 박막인 경우에는 465($\omega/\Box$)에서 448($\omega/\Box$)로 안정화 되었고, 투과율은 성막직전 열처리를 통해 1%향상되어 89%를 보였고, 유연성 또한 보다 우수한 특성을 보였다. 표면 조도는 평균 0.416 nm의 낮은 값을 보였다. 이는 PET 기판의 degassing 공정 중 충분히 제거되지 않은 가스나 불순물을 성막직전 열처리 공정으로 충분히 제거하여 깨끗한 PET 기판 상에 ITO 박막을 성막시키고, 열처리시 기판에 주어진 열에너지에 의해 보다 밀도가 높은 ITO 박막이 성장했기 때문으로 사료 된다.

  • PDF

Improved Uniformity in Resistive Switching Characteristics of GeSe Thin Film by Ag Nanocrystals

  • Park, Ye-Na;Shin, Tae-Jun;Lee, Hyun-Jin;Lee, Ji-Soo;Jeong, Yong-Ki;Ahn, So-Hyun;Lee, On-You;Kim, Jang-Han;Nam, Ki-Hyun;Chung, Hong-Bay
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.237.2-237.2
    • /
    • 2013
  • ReRAM cell, also known as conductive bridging RAM (CBRAM), is a resistive switching memory based on non-volatile formation and dissolution of conductive filament in a solid electrolyte [1,2]. Especially, Chalcogenide-based ReRAM have become a promising candidate due to the simple structure, high density and low power operation than other types of ReRAM but the uniformity of switching parameter is undesirable. It is because diffusion of ions from anode to cathode in solid electrolyte layer is random [3]. That is to say, the formation of conductive filament is not go through the same paths in each switching cycle which is one of the major obstacles for performance improvement of ReRAM devices. Therefore, to control of nonuniform conductive filament formation is a key point to achieve a high performance ReRAM. In this paper, we demonstrated the enhanced repeatable bipolar resistive switching memory characteristics by spreading the Ag nanocrystals (Ag NCs) on amorphous GeSe layer compared to the conventional Ag/GeSe/Pt structure without Ag NCs. The Ag NCs and Ag top electrode act as a metal supply source of our devices. Excellent resistive switching memory characteristics were obtained and improvement of voltage distribution was achieved from the Al/Ag NCs/GeSe/Pt structure. At the same time, a stable DC endurance (>100 cycles) and an excellent data retention (>104 sec) properties was found from the Al/Ag NCs/GeSe/ Pt structured ReRAMs.

  • PDF

ITER 초전도자석 전원장치용 변압기의 제작 및 시험 현황 (The Status of Manufacturing and Test for ITER AC/DC Converter Transformers)

  • 최정완;서재학;오종석;신현국;이장수;손명공;김승모;김명기
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 추계학술대회 논문집
    • /
    • pp.227-228
    • /
    • 2015
  • 우리나라가 조달하는 ITER(국제핵융합시험로) 초전도자석 전원장치용 변압기는 CCU/L(Correction Coil Upper/Lower) 컨버터 형식용 6대, CCS(Correction Coil Side) 컨버터 형식용 3대, VS1(Vertical Stabilization 1) 컨버터 형식용 2대, CS(Central Solenoid) 컨버터 형식용 6대 그리고 TF(Toroidal Field) 컨버터 형식용 1대로 구성되어 있다. ITER한국사업단은 (주)효성과 컨버터 변압기의 공급계약을 2011년에 체결하고 예비 설계를 시작하여 2014년에 최종설계를 마친 후 동년 후반부터 CCU/L, CCS 및 VS1 컨버터 형식용 각 1대씩의 초도품 변압기 제작에 착수하였다. 각 변압기는 제작이 완료되어 CCU/L 및 CCS 형식은 FAT(Factory Acceptance Test)를 완료하였고 VS1 형식은 공장 자체시험을 완료하고 현재 전기연구원에서 실시할 단락시험을 준비하고 있다. 이어 CS 형식의 초도품과 1대만 조달하는 TF 형식의 제작을 착수할 예정이고, 각 형식별 초도품 1대씩은 단락시험을 포함하는 형식시험(Type Test)을 실시하여 형식별 적합성을 검증하고, 나머지 물량은 정기시험(Routine Test)을 실시한 후 2017년까지 두 번으로 나누어 프랑스 남부에 위치한 ITER 현장에 운송 및 설치할 예정이다. 설치를 마친 변압기들은 각각의 컨버터 짝과 통합시험을 포함하는 SAT(Site Acceptance Teat)를 거친 후 ITER 기구에 인계될 예정이다.

  • PDF

태양광 어레이 I-V 곡선 측정을 위한 다채널 동시 측정방법에 관한 연구 (The Study of Method about the Multi-channel Simultaneous Measurement for Measuring the I-V Curve of Photovoltaic Array)

  • 박유나;장길수;고석환;강기환;소정훈;정영석;주영철;황혜미;송형준
    • 한국태양에너지학회 논문집
    • /
    • 제37권4호
    • /
    • pp.23-33
    • /
    • 2017
  • A great deal of study for loss reduction of photovoltaic system is conducted currently. It is hard to distinct the fault of photovoltaic system with the naked eye. For that reason, it is essential to repair and maintain the PV system by monitoring the system. The fault of individual modules can cause the huge loss of the entire system because of the mismatch. Therefore, the method of diagnosing the PV array is necessary by measuring the multi-channel arrays simultaneously. In this paper, it is presented the method of measuring I-V curve of multi-channel arrays simultaneously by using the charge and discharge characteristics of capacitor. Generated DC power at PV arrays is charged and discharged at the capacitors in a moment. By measuring the charged voltage and current, it is possible to diagnose of performance of PV arrays.

PEO 처리시 Ca-GP첨가에 따른 AZ31합금의 내식성 및 표면특성에 관한 연구 (A study on corrosion resistance and surface properties of AZ31 alloy according to Ca-GP addition during PEO treatment)

  • 이준수;박제신;박일송
    • 한국표면공학회지
    • /
    • 제54권5호
    • /
    • pp.238-247
    • /
    • 2021
  • PEO (plasma electrolytic oxidation) was applied to modify the surface of AZ31 magnesium alloy in this study. The mixed solution of sodium hydroxide (NaOH) and sodium silicate (Na2SiO3) was used as the electrolyte, and 0 - 0.05 g/L of Ca-GP (Glycerol Phosphate Calcium salt) was added in the electrolyte as an additive. PEO treatment was conducted at a current density of 30mA/cm2 for 5 minutes using a DC power supply. The surface properties were identified by SEM, XRD and surface roughness analyses, and the corrosion resistance was evaluated by potentiodynamic polarization and immersion tests. In addition, the biocompatibility was evaluated by immersion test in SBF solution. As the concentration of Ca-GP was increased, the surface morphology was denser and more uniform, and the amount of Ca and the thickness of oxide layer increased. Only Mg peak was observed in XRD analysis due to very thin oxide layer. The corrosion resistance of PEO-treated samples increased with the concentration of Ca-GP in comparision with the untreated sample. In particular, the highest corrosion resistance was identified at the group of 0.04g Ca-GP through potentiodynamic polarization and immersion tests in saline solution (0.9 wt.%NaCl). During the immersion in saline solution, pH rapidly increased at the beginning of immersion period due to rapid corrosion, and then increase rate of pH decreased. However, the pH value in the SBF temporarily increased from 7.4 to 8.5 during the day, then decreased due to the inhibition of corrosion with HA(hydroxyapatite) formation.

Protection properties of HTS coil charging by rotary HTS flux pump in charging and compensation modes

  • Han, Seunghak;Kim, Ji Hyung;Chae, Yoon Seok;Quach, Huu Luong;Yoon, Yong Soo;Kim, Ho Min
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권4호
    • /
    • pp.19-24
    • /
    • 2021
  • The low normal zone propagation velocity (NZPV) of high-temperature superconducting (HTS) tape leads to a quench protection problem in HTS magnet applications. To overcome this limitation, various studies were conducted on HTS coils without turn-to-turn insulation (NI coils) that can achieve self-protection. On the other hand, NI coils have some disadvantages such as slow charging and discharging time. Previously, the HTS coils with turn-to-turn insulation (INS coils) were operated in power supply (PS) driven mode, which requires physical contact with the external PS at room-temperature, not in persistent current mode. When a quench occurs in INS coils, the low NZPV delays quench detection and protection, thereby damaging the coils. However, the rotary HTS flux pump supplies the DC voltage to the superconducting circuit with INS coils in a non-contact manner, which causes the INS coils to operate in a persistent current mode, while enabling quench protection. In this paper, a new protection characteristic of HTS coils is investigated with INS coils charging through the rotary HTS flux pump. To experimentally verify the quench protection characteristic of the INS coil, we investigated the current magnitude of the superconducting circuit through a quench, which was intentionally generated by thermal disturbances in the INS coil under charging or steady state. Our results confirmed the protection characteristic of INS coils using a rotary HTS flux pump.

플라스틱 기어의 트라이볼로지적 특성 향상을 위한 DLC 코팅 적용 (Evaluation of Tribological Characteristics of Diamond-Like Carbon (DLC) Coated Plastic Gear)

  • 배수민;마디 카뎀;서국진;김대은
    • Tribology and Lubricants
    • /
    • 제35권1호
    • /
    • pp.1-8
    • /
    • 2019
  • Demand for plastic gears are increasing in many industries due to their low production cost, light weight, applicability without lubricant, corrosion resistance and high resilience. Despite these benefits, utilizing plastic gears is limited due to their poor material properties. In this work, DLC coating was applied to improve the tribological properties of polyamide66 gear. 0 V, 40 V, and 70 V of negative bias voltages were selected as a deposition parameter in DC magnetron sputtering system. Pin-on-disk experiment was performed in order to investigate the wear characteristics of the gears. The results of the pin-on-disk experiment showed that DLC coated polyamide66 with 40 V of negative bias voltage had the lowest friction coefficient value (0.134) and DLC coated PA66 with 0 V of negative bias voltage showed the best wear resistance ($9.83{\times}10^{-10}mm^3/N{\cdot}mm$) among all the specimens. Based on these results, durability tests were conducted for DLC coated polyamide66 gears with 0 V of negative bias voltage. The tests showed that the temperature of the uncoated polyamide66 gear increased to about $37^{\circ}C$ while the DLC coated gear saturated at about $25^{\circ}C$. Also, the power transmission efficiency of the DLC coated gear increased by about 6% compared to those without coating. Weight loss of the polyamide66 gears were reduced by about 73%.

KSTAR 전류전송계통 진공배기계 구축 및 시운전 (Construction and Tests of the Vacuum Pumping System for KSTAR Current Feeder System)

  • 우인식;송낙형;이영주;곽상우;방은남;이근수;김정수;장용복;박현택;홍재식;박영민;김양수;최창호
    • 한국진공학회지
    • /
    • 제16권6호
    • /
    • pp.483-488
    • /
    • 2007
  • KSTAR (Korea Superconducting Tokamak Advanced Research) 전류전송계 (Current Feeder System)는 4.5 K의 저온에서 운전되는 초전도자석과 300 K의 실온에서 운전되는 전원장치 (Magnet Power Supply)를 전기적으로 연결하는 장치이다. 전류전송계는 최대 35 kA의 DC 전류가 인가되는 TF 자석용 및 350초간 20$\sim$26 ㎄의펄스 전류가 인가되는 PF 자석용으로 분리되어 있으며 리드박스 내부는 전류인입선, 초전도버스라인, 열차폐체 및 냉각라인 등이 설치되어 있다. 리드박스와 초전도버스라인 진공덕트는 KSTAR 주장치와는 별도로 진공배기 시스템이 구축되어있으며, 전체적으로 아령 형상을 하고 있는 진공공간을 효율적으로 진공배기하기 위하여 버스라인 덕트와 주장치 저온용기 사이에 진공 분리막 (Vacuum Separator)이 설치되어 있다. 진공배기를 위한 초벌배기계는 로터리펌프 및 부스터펌프 (Mechanical Booster Pump)로 구축되었으며 고진공 배기계는 4대의 크라이오펌프 (Cryo-pump)로 구축되었다. 진공장치 운전을 위해 PLC 기반의 로컬 제어시스템을 구축하였고 장치 안전을 위한 자체 인터록과 중앙인터록 시스템 및 중앙제어연계시스템이 함께 구축되어 있다. 전류전송계 설치완료 후 진공배기 시운전을 통해 배기시스템의 자가진단 및 리드박스 내부에 설치되어 있는 헬륨배관의 진공누설검사를 완료하였으며, 액체질소를 사용하여 전류인입선 냉각시험을 완료하였다.

국내 전철 및 가전제품을 대상으로 한 전자장 수준 실태조사 (A survey on the EMF Levels of Study and Electric Appliances in Korea)

  • 장성기;조용성;이석조;유승화;정경미;임준호
    • 한국산업보건학회지
    • /
    • 제15권1호
    • /
    • pp.71-81
    • /
    • 2005
  • The purposes of this study was to collect, analyze, and describe the MF exposure levels from subways in Korea and to measure and evaluate the MF levels generated from electric appliances used at general homes. The target subway lines were Seoul Metropolitan Line 1 to Line 8, Bundang Line, Incheon Line, Daegu Line, Gwangju Line, and Busan Line 1 and Line 2. We measured at each station in those subway lines and, all the train types (pantograph-equipped, motor-equipped, and common), and platform types(facing and isolating) were investigated by the distance(80, 200, 400 cm) from the train on 19 targeted subway lines using 3 magnetic field measuring devices (EMDEXII, Enertech Co.) during the survey from January till October, 2004. On the other hand, the levels of the 60Hz magnetic fields generated from 14 items of home electric appliances such as electric blankets, hair dryers, electric razors, etc. were measured at 10 general homes using 5 EMDEXII meters with a sampling interval of 1.5 second by the distance(surface, 30, 50, 100, 300cm ) from the target electric appliances. The survey results in the whole subway lines examined in this study were as follows; Seoul Metropolitan Line 4 using AC(alternating current) power source showed the highest mean value of $2.85{\mu}T$, followed by Seoul Metropolitan Line 1 running between Seoul and Incheon using AC($2.78{\mu}T$), Seoul Metropolitan Line 1 between Seoul and Uijongbu using AC($2.73{\mu}T$), Bundang Line using AC($1.79{\mu}T$), Seoul Metropolitan Line 1 connected from Yongsan using AC($1.67{\mu}T$), Seoul Metropolitan Line 1 between Seoul and Suwon using AC($0.79{\mu}T$), and so on. In general, the intensity of the magnetic field in the subway systems in Korea was significantly higher when using AC($2.14{\pm}0.91{\mu}T$) than when using DC($0.29{\pm}0.44{\mu}T$) power source. Among the home electric appliances examined, microwave ovens showed the highest mean value of $7.69{\mu}T$, followed by hair dryers($6.47{\mu}T$), vacuum cleaners($5.27{\mu}T$), televisions ($2.26{\mu}T$), electric blankets($1.38{\mu}T$), personal computers ($0.81{\mu}T$), and so on. Two items of electric appliances showed the excess value of $0.2{\mu}T$ at the distance of 30cm in the MF exposure level; electric razors $1.58{\pm}2.13{\mu}T$ and vacuum cleaners $0.48{\pm}0.44{\mu}T$. As a whole, this study showed a tendency that the shift of the MF levels according to the increase of distance from the electric appliances was lower than those of the results surveyed in UK and USA. As a result, this study is expected to suggest meaningful data for the future study in exposure assessment of magnetic fields and for the establishment of guidelines for subways and electric appliances in Korea. More detailed and large scaled exposure assessment studies should be performed continuously to get the various and useful information on health risk assessment of MFs in Korea.