• 제목/요약/키워드: DC load flow

검색결과 60건 처리시간 0.031초

직류 배전 시스템을 위한 고효율 양방향 컨버터의 설계 (Design of the High Efficiency Bidirectional Converter for DC Distributed Power System)

  • Tran, Duc-Hung;Choi, Woojin
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 추계학술대회 논문집
    • /
    • pp.5-6
    • /
    • 2016
  • This paper introduces a high efficiency bidirectional resonant converter using an additional LC auxiliary circuit for dcdistribution applications. The LC auxiliary circuit operates as a variable inductor and the additional LC circuit helps to increase the effective magnetizing inductance, thereby reducing the turn-off and primary circulating current. A 5 kW bidirectional converter for dc-distribution system is implemented to verify the validity of the proposed method. The experimental results show the high efficiency characteristics of the proposed converter over the wide range of load in both direction of power flow. The maximum efficiency of the proposed system was 98.1 % at 3 kW.

  • PDF

1500 A, 400 mH급 초전도 직류 리액터용 극저온 냉각 시스템 구조 설계 및 열 해석 (Structure Design and Thermal Analysis of Cryogenic Cooling System for a 1500 A, 400 mH Class HTS DC Reactor)

  • 권다어반;레덧탕;성해진;박민원;유인근
    • 한국산업정보학회논문지
    • /
    • 제23권1호
    • /
    • pp.31-41
    • /
    • 2018
  • 이 논문에서는 대 전류, 고온 초전도 직류 리액터를 위한 전도 냉각 시스템의 구조 설계에 대해 논의하고자 한다. 초전도 자석, 보 빈, 전류 리드, 고정용 구조물 그리고 열 교환기가 포함된 전도 냉각 시스템 부품의 크기를 3D CAD 프로그램을 사용하여 계산하였다. 또한, 최적의 설계 변수를 결정하고 열적-기계적 특성을 분석하기 위해서 유한 요소법 모델을 제작하였다. 리액터 자석의 운전 전류와 인덕턴스는 각각 1,500 A 400 mH이며, 이에 따른 극저온 냉동기의 냉각 용량을 결정하기 위해 초전도 직류 리액터에서 발생하는 열 부하를 계산하였다. 또한, 대 전류가 흐르는 1 단부전도 냉각 시스템의 작동 테스트를 수행하였다. 구리 바는 40 K까지 냉각되었고 초전도 리드는 안정적으로 작동했다. 실험 결과로써, 1 단부 영역의 총 열 부하는 190 W였다. 본 연구 결과는 상용 초전도 직류 리액터의 설계 및 제조에 있어 효과적으로 활용 될 것이다.

전압 변동 보상항을 이용한 직류 마이크로그리드의 에너지 관리 기법 (Energy Management Method of DC Microgrids by Using Voltage Compensation Term)

  • 고병선;이기영;김석웅;김래영
    • 전력전자학회논문지
    • /
    • 제23권5호
    • /
    • pp.328-335
    • /
    • 2018
  • An energy management method of DC microgrids using voltage compensation term is proposed in this study. Droop control is often implemented to operate the DC microgrid. However, the droop control necessarily generates voltage variation. Energy flow is also difficult to control because the droop control mainly focuses on proportional load sharing. To solve these problems, the voltage compensation term based on the low-bandwidth communication is used to determine the operating band of the converter. Energy management and voltage variation minimization can be achieved by judging the operating band according to the magnitude of voltage compensation term. The validity of the proposed method is verified by simulation and experiments.

직류 마이크로그리드의 전력 공유 정확도 및 전압 제어 성능 향상을 위한 전압 민감도 행렬 기반의 분산 제어 방법 (A Distributed Control Method based on Voltage Sensitivity Matrix in DC Microgrids for Improvement of Power Sharing Accuracy and Voltage Regulation Performance)

  • 이기영;고병선;이재석;김래영
    • 전력전자학회논문지
    • /
    • 제23권5호
    • /
    • pp.345-351
    • /
    • 2018
  • A distributed control method is proposed to improve the power sharing performance of bidirectional distributed generators and the voltage regulation performance of a DC bus in a DC microgrid. Voltage sensitivity analysis based on power flow analysis is conducted to analyze the structural characteristics of a DC microgrid. A distributed control method using a voltage sensitivity matrix is proposed on the basis of this analysis. The proposed method uses information received through the communication system and performs the droop gain variation method and voltage shift method without additional PI controllers. This approach achieves improved power sharing and voltage regulation performance without output transient states. The proposed method is implemented through a laboratory-scaled experimental system consisting of two bidirectional distributed generators, namely, a load and a non-dispatchable distributed generator in a four-bus ring-type model. The experimental results show improved power sharing accuracy and voltage regulation performance.

융통전력 여유 향상을 위한 BTB 컨버터 제어 전략 수립 (On Control Strategies for BTB Converters for Enhancement of Interface Flow Margins)

  • 온성민;송화창;장병훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.374-375
    • /
    • 2011
  • This paper presents a method to determine parameters of BTB (back-to-back) converters in terms of the enhancement of interface flow margins. Interface flow margin is by definition a measure of how much active power can be transferred from the external areas to the study area with the fixed load demand, and it is mainly constrained by system voltage stability. BTB converters are controllable equipments with the active power flow through them, and its DC link in fact can divide the AC systems at the location and hence can reduce the fault current level. This paper first cals margin sensitivities at the nose point of F-V curves and formulates an optimization problem to update the BTB parameters to improve the margins. This procedure is repeated performed until the required margin enhancement is achieved.

  • PDF

불평형 부하에서의 능동필터에 관한 연구 (The Study on the Active Power Filter in Unbalanced Load)

  • 최시영;이우철;이택기;현동석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권3호
    • /
    • pp.130-140
    • /
    • 2001
  • This paper presents the performance of a parallel active power filter(PT) system in unbalanced load condition. The unbalanced load leads to negative sequence of current, and makes 120Hz ripple in the DC-link voltage forcing large capacitance and increases the rating of APF. thus, the separation of negative sequence is performed in synchronous reference frame and controlled to flow into supply network. The validity of the scheme is investigated through simulation and the experimental results for a prototype active power filter system rated at 10kVA.

  • PDF

인버터 에어컨 시스템의 역률보상을 위한 AC-DC 컨버터 제어 (AC-DC Converter Control for Power Factor Correction of Inverter Air Conditioner System)

  • 박귀근;최재원
    • 제어로봇시스템학회논문지
    • /
    • 제13권2호
    • /
    • pp.154-162
    • /
    • 2007
  • In this paper, we propose a new AC-DC converter control method to comply with harmonics regulation(IEC 61000-3) effective for the inverter system of an air conditioner whose power consumption is less than 2,500W. There are many different ways of AC-DC converter control, but this paper focuses on the converter control method that is adopting an input reactor with low cost silicon steel core to strengthen cost competitiveness of the manufacturer. The proposed control method controls input current every half cycle of the line frequency to get unit power factor and at the same time to reduce switching loss of devices and acoustic noise from reactor. This kind of converter is known as a Partial Switching Converter(PSC). In this study, theoretical analysis of the PSC has been performed using Matlab/Simulink while a 16-bit micro-processor based converter has been used to perform the experimental analysis. In the theoretical analysis, electrical circuit models and equations of the PSC are derived and simulated. In the experiments, micro-processor controls input current to keep the power factor above 0.95 by reducing the phase difference between input voltage and current and at the same time to maintain a reference DC-link voltage against voltage drop which depends on DC-link load. Therefore it becomes possible to comply with harmonic regulations while the power factor is maximized by optimizing the time of current flow through the input reactor for every half cycle of line frequency.

각 부하지점별 유효부하지속곡선 작성법에 관한 연구 (A Study on Construction of the CMELDC at Load Points)

  • 김홍식;문승필;최재석
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권4호
    • /
    • pp.195-198
    • /
    • 2000
  • This paper illustrates a new method for constructing composite power system effective load duration curve(CMELDC) at load points. The main concept of proposed method is that the CMELDC can be obtain from convolution integral processing of the outage probabilistic distribution function of not supplied power and the load duration curve given at each load point. The effective load duration curve (ELDC) at HLI plays an important part in probabilistic production simulation, reliability evaluation, outage cost assessment and power supply margins assesment for power system planning and operation. And also, the CMELDC at HLII will extend the application areas of outage cost assessment and reliability evaluation at each load point. The CMELDC at load points using the Monte Carlo method and a DC load flow constrained LP have already been developed by authors. The effective load concept at HLII, however, has not been introduced sufficiently in last paper although the concept is important. In this paper, the main concept of the effective load at HLII which is proposed in this study is defined in details as the summation of the original load and the probabilistic loads caused by the forced outage of generators and transmission lines at this load point. The outage capacity probabilistic distribution function at HLII can be obtained by combining the not supplied powers and the probabilities of the not supplied powers at this load point. It si also expected that the proposed CMELDC can be applied usefully to research areas such as reliability evaluation, probabilistic production cost simulation and analytical outage cost assessment, etc. at HLII in future. The characteristics and effectiveness of this methodology are illustrated by case study of IEEE-RTS.

  • PDF

765kV 비연가 송전계통 과도 특성에 관한 고찰 (A Study on the Transient Characteristics in 765kV Untransposed Transmission Systems)

  • 안용진;강상희
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권7호
    • /
    • pp.397-404
    • /
    • 2004
  • This paper describes a study of transient characteristics in 765kV untransposed transmission lines. As the 765(kV) system can carry bulk power, some severe fault on the system nay cause large system disturbance. The large shunt capacitance and small resistance of 765kv transmission line make various difficulties for its protection. These problems including current difference between sending and receiving terminals on normal power flow, low order harmonic current component in fault current and current transformer saturation due to the long DC time constant of the circuit etc. must be investigated and solved. The analysis of transient characteristics at sending terminal has been carried out for the single phase to ground fault and 3-phase short fault, etc. The load current, charging current in normal condition and line flows, fault current, THD(Total Harmonic Distortion) of harmonics, time constants have been analysed for the 765kV untransposed transmission line systems.

Development of Energy Management System for Micro-Grid with Photovoltaic and Battery system

  • Asghar, Furqan;Talha, Muhammad;Kim, Sung-Ho
    • 한국지능시스템학회논문지
    • /
    • 제25권3호
    • /
    • pp.299-305
    • /
    • 2015
  • Global environmental concerns and the ever increasing need of energy, coupled with steady progress in renewable energy technologies, are opening up new opportunities for utilization of renewable energy resources. Distributed electricity generation is a suitable option for sustainable development thanks to the load management benefits and the opportunity to provide electricity to remote areas. Solar energy being easy to harness, non-polluting and never ending is one of the best renewable energy sources for electricity generation in present and future time. Due to the random and intermittent nature of solar source, PV plants require the adoption of an energy storage and management system to compensate fluctuations and to meet the energy demand during night hours. This paper presents an efficient, economic and technical model for the design of a MPPT based grid connected PV with battery storage and management system. This system satisfies the energy demand through the PV based battery energy storage system. The aim is to present PV-BES system design and management strategy to maximize the system performance and economic profitability. PV-BES (photovoltaic based battery energy storage) system is operated in different modes to verify the system feasibility. In case of excess energy (mode 1), Li-ion batteries are charged using CC-CV mechanism effectively controlled by fuzzy logic based PID control system whereas during the time of insufficient power from PV system (mode 2), batteries are used as backup to compensate the power shortage at load and likewise other modes for different scenarios. This operational mode change in PV-BES system is implemented by State flow chart technique based on SOC, DC bus voltages and solar Irradiance. Performance of the proposed PV-BES system is verified by some simulations study. Simulation results showed that proposed system can overcome the disturbance of external environmental changes, and controls the energy flow in efficient and economical way.