• 제목/요약/키워드: DC leakage current

검색결과 242건 처리시간 0.024초

A Zero Voltage Switching Phase Shift Full Bridge Converter with Separated Primary Winding

  • Kim, Young-Do;Kim, Chong-Eun;Cho, Kyu-Min;Park, Ki-Bum;Cho, In-Ho;Moon, Gun-Woo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.379-381
    • /
    • 2008
  • Generally additional leakage inductance and two clamp diodes are adopted into the conventional phase shift full bridge (PSFB) converter for reducing the voltage stress of secondary rectifier diodes and extending the range of zero voltage switching (ZVS) operation. However, since additional leakage inductance carries the ac current similar to the primary one, the core and copper loss oriented from additional leakage inductance can be high enough to decrease the whole efficiency of DC/DC converter. Therefore, in this paper, a new ZVS phase shift full bridge converter with separated primary winding (SPW) is proposed. Proposed converter makes the transformer and additional leakage inductor with one ferrite core. Using this method, leakage inductance is controlled by the winding ratio of separated primary winding. Moreover, by manufacturing the both magnetic components with one core, size and core loss can be reduced and it turns out the improvement of efficiency and power density of DC/DC converter. The operational principle of proposed converter is analyzed and verified by the 1.2kW prototype.

  • PDF

반응성 스퍼터링법으로 Al/AIN/GaAs MIS 커패시터 제조시 DC 전력에 따른 전기적 특성 (Electrical Characteristic of Al/AIN/GaAs MIS Capacitor fabricated by Reactive Sputtering Method for the DC power)

  • 권정열;이헌용;김지균;김병호;김유경
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.566-569
    • /
    • 2001
  • In this paper, we investigated the electrical characteristics through DC power at manufacturing the MIS capacitor insulator AIN thin film based on reactive sputtering method. In case of deposition temperature 250$^{\circ}C$, pressure 5mTorr, total flow rate 8sccm(Ar:4sccm N2:4sccm), AIN thin film was deposited with changing DC power. As DC power increses, resistivity is observed a little increase. When AIN thin film is deposited at 100W, the result shows leakage current 10$\^$-8/A/$\textrm{cm}^2$ at 0.1MV/cm. Otherwise, In case of depositing at 150W and 200W, the result shows that the characteristic of leakage current is under 10$\^$-9//$\textrm{cm}^2$ at 0.1MV/cm. In C-V characteristic with DC power, deep depletion phenomenon is observed at inversion region in 100W and 150W. In 200W, that phenomenon, however, was showed to decrease. It shows that the hysterisis increases with being increasing DC power.

  • PDF

UHF RFID 응용을 위한 NMOS 게이트 교차연결 전류미러형 브리지 정류기의 설계 및 해석 (Design and Analysis of a NMOS Gate Cross-connected Current-mirror Type Bridge Rectifier for UHF RFID Applications)

  • 박광민
    • 대한전자공학회논문지SD
    • /
    • 제45권6호
    • /
    • pp.10-15
    • /
    • 2008
  • 본 논문에서는 UHF RFID 응용을 위한 새로운 NMOS 게이트 교차연결 전류미러형 브리지 정류기를 제시하였다. 제시된 정류기의 직류 변환 특성은 고주파 등가회로를 이용하여 해석하였으며, 주파수 증가에 따른 게이트 누설전류를 회로적인 방법으로 줄일 수 있는 게이트 커패시턴스 감소 기법을 이론적으로 제시하였다. 구해진 결과, 제안한 정류기는 기존의 게이트 교차 연결형 정류기와 거의 같은 직류 출력전압 특성을 보이면서도, 게이트 누설전류가 1/4 이하로 감소하고, 부하저항에서의 소비전력도 30% 이상 감소하며, 부하저항의 변화에 대해 보다 안정적인 직류전압을 공급함을 알 수 있었다. 또한 제안한 정류기는 13.56MHz의 HF(for ISO 18000-3)부터 915MHz의 UHF(for ISO 18000-6) 및 2.45GHz의 마이크로파 대역 (for ISO 18000-4)까지의 전 주파수 범위에 대해 충분히 높고 잘 정류된 직류 변환 특성을 보여 특정 주파수 대역을 사용하는 다양한 RFID 시스템의 트랜스폰더 칩 구동을 위한 범용 정류기로 사용될 수 있다.

13kW급 고주파 ZVS FB DC-DC 콘버터 개발 (A Study on the Development of A 13kW High Frequency ZVS FB DC-DC Converter)

  • 김은수;조기연;이재훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.542-546
    • /
    • 1994
  • The objective of the study is to design and develope a 13kW zero voltage switching DC-DC Converter far high power application. Due to using the snubber capacitor in the right leg instead of increasing transformer leakage inductance, DC characteristics and the total efficiency in the proposed ZVS DC-DC converter is increased mere than in the conventional ZVS DC-DC converter by reduction of the circulating current when the load current is large. Also, this paper includes simulation and experimental results of the proposed ZVS FB DC-DC converter.

  • PDF

직류 접지극의 전식보호 방법 연구 (Research on Protection Method for Ground Electrode of DC Systems from Corrosion)

  • 정우용;김효성
    • 전력전자학회논문지
    • /
    • 제26권2호
    • /
    • pp.90-95
    • /
    • 2021
  • In contrast to AC grounding systems, the ground electrode in DC systems continuously maintains positive or negative polarity. Ground electrodes with (+) polarity proceeds by oxidation reaction. Thus, the DC current should flow opposite to the polarity of the leakage current flowing through the (+) ground electrode by using a compensation electrode, and the current flowing through the (+) ground electrode can be 0A. However, according to protecting the (+) ground electrode, the compensation electrode corrodes and gets damaged. Thus, the (+) ground electrode must be protected from corrosion, and the service life of the compensation electrode must be extended. As an alternative, the average value of the current flowing through the compensation electrode should be equal with the value of the leakage current flowing through the (+) ground electrode by using the square waveform. Throughout the experiment, the degree of corrosion on the compensation electrode is analyzed by the frequency of the compensation electrode for a certain time. In the experiment, the frequencies of the square waveform are considered for 0.1, 1, 10, 20, 50, 100 Hz, and 1 kHz. Through experiments and analysis, the optimal frequency for reducing the electrolytic damage of the (+) electrode and compensation electrode in an LVDC grounding environment is determined.

절연유(絶緣油) 열화(劣化)센서 특성(特性) 연구(硏究) (A Study on the characteristics of degradation sensor for insulation oil)

  • 전영갑;선종호;강동식;주병수;윤진열;정상진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1371-1374
    • /
    • 1995
  • It is well known that the degradation of transformer oil conseqently lead to the failure of transformer. This paper discussed the characteristics of the degradation sensor checking transformer oil condition in live line. The degadation sensor is composed of base ring, electrodes and porous ceramic, passed through the transformer oil and checks the transformer oil condition through sensor's leakage current. So it is important to minimize the leakage current of base ring and connection parts. To investigate the leakage current of base ring and connection parts the characteristics of V-T-I and DC 2 KV and other examinations were performed. It is verified that ionized transformer oil caused by the expansion of temperature increases in the leakage current of porous ceramic sensor. It is certification that the leakage current of other parts of porous ceramic is very small(about 2%) compared with the porous ceramic body and it is confirmed that the leakage current in porous ceramic is changed sensitively according to the new oil(NO) and and the degradation oil(DO).

  • PDF

변압기(變壓器) 절연유(絶緣油) 열화(劣化)센서의 특성연구(特性硏究) (A study on the characteristics of degradation sensor for transformer insulation oil)

  • 전영갑;선종호;강동식;김문덕;권동진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1765-1768
    • /
    • 1996
  • It is well known that the degradation transformer oil is mainly effected to the failure of transformer. In this paper it is discussed the characteristics of the degradation sensor checking transformer oil condition in live line. The degadation sensor composed with base ring, electrodes and porous ceramic passed through the transformer oil and checked the transformer oil condition with sensor's leakage current. It is important to minimize the leakage current of base ring and connection parts. To investigate the leakage current of base ring and connection parts it is examined the characteristics of V-T-I and DC 2 KV and other examinations. It is verified that ionized transformer caused by the expansion of oil temperature increase in the leakage current of porous ceramic sensor. It is certificated that the leakage current of other parts of porous ceramic is very small (about 2 %) than the porous ceramic and it is confirmed that the leakage current in porous ceramic is changed sensitively according to the new oil(NO) and and the degradation oil(DO).

  • PDF

Labview를 이용한 배전용 폴리머애자의 누설전류 측정 및 분석 프로그램 개발 (Development of data acquisition and analysis program modules for leakage current of polymeric insulators using the Labview software)

  • 조성수;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1969-1971
    • /
    • 2000
  • This paper presents a data acquisition and analysis program modules that has been developed using the Labview program. These program modules can use to acquire and analyze leakage current data of insulator under different contamination conditions. The experimental hardware made up salt fog chamber, AC/DC power supply, transducer (shunt resistor), measurement devices and PC with the GPIB (General Purpose Interface Bus). And analysis program modules can calculate pulse level count, accumulated charge, average leakage current, power spectrum, and harmonics. The result of applying these analytical program modules to polymeric insulator is available for evaluation of leakage current characteristic of outdoor insulators.

  • PDF

HVDC용 LSR/Nano Silica Composites의 IPT특성 연구 (Study on IPT Characteristics of LSR / Nano Silica Composites for HVDC)

  • 박재준
    • 전기학회논문지
    • /
    • 제68권1호
    • /
    • pp.61-68
    • /
    • 2019
  • Only the power is converted from AC to DC, in accordance with IEC 60587 based test method, in order to develop the LSR(Liquid Silicone Rubber) insulator material for HVDC, the experiment of Inclined Plate Tracking and Erosion Resistance was conducted. A contaminant (2.5 mS/cm: ammonium chloride) was applied at a rate of 0.3 ml/min and a voltage of ${\pm}3.5kV$, and was evaluated on the basis of 60 mA/2s. The samples were prepared by dispersing LSR/Nano silica_25wt% Composites in LSR. The erosion phenomena of surface discharge and tracking due to DC polarity and negative polarity were measured by image, leakage current maximum and thermal camera. The thermal imaging camera measured the surface temperature generated by the joule heat of the leakage current due to the drying discharge and the conductive current. After the measurement, the tracking and erosion mechanisms were evaluated for erosion weight, erosion depth and erosion length. Positive and negative polarity of LSR/Nano Silica_25wt% composite Tracking and erosion results show that positive polarity is more severe than negative polarity.

변압기 2차측 LLC 직렬공진컨버터 적용 승압형 DC/DC 컨버터 (The Secondary LLC Series Resonant Converter for the Boost DC/DC Converter)

  • 이현관;차인수;이기식;정봉근;강성인;김은수
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권8호
    • /
    • pp.423-429
    • /
    • 2006
  • Recently, the high frequency isolated boost DC/DC converter has been widely used for the PCS (Power Conditioning System) system because of its small size and low cost. However, the high frequency isolated boost DC/DC converters applied the conventional voltage-fed converter and current-fed converter have the problems such as the high conduction losses and the surge voltage due to the high circulating current and the leakage inductance, respectively. To overcome this problems, in this paper the secondary LLC resonant converter is proposed, and the experimental results of the secondary LLC series resonant converter for boost DC/DC converter are verified on the simulation based on the theoretical analysis and the 700W experimental prototype.