• Title/Summary/Keyword: DC leakage current

Search Result 242, Processing Time 0.024 seconds

Influence of Dy Doping on Electrical Properties and dc Aging Behaviors of Zn-Pr-Co-Cr System

  • Nahm, Choon-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.6
    • /
    • pp.234-240
    • /
    • 2007
  • The electrical properties and dc aging behavior for specified stress state of system, which is composed of quaternary Zn-Pr-Co-Cr, were investigated for different $Dy_2O_3$ addition doping level. As $Dy_2O_3$ doping level increased, the density decreased in the range of 5.51-4.90 $g/cm^3$, reaching maximum at 0.5 mol% and the average ZnO grain size decreased in the range of 17.7-6.0 ${\mu}m$. The incorporation of $Dy_2O_3$ significantly improved the non-ohmic properties, above 30 in non-ohmic coefficient, compared with that of undoped samples. The samples with the best performance of non-ohmic properties were obtained for $Dy_2O_3$ doping level of 1.0 mol%, with 49 in non-ohmic coefficient and 2.6 ${\mu}A/cm^2$ in leakage current. The samples with the highest stability were obtained for $Dy_2O_3$ doping level of 0.5 mol%.

A Study on the Electrical Fire Risk Assessment Methods of LED Lightings for Outdoor (옥외용 LED 조명의 전기화재 위험성 평가기법에 관한 연구)

  • Kim, Hyang-Kon;Kim, Dong-Ook;Choi, Hyo-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.3
    • /
    • pp.674-679
    • /
    • 2011
  • In this paper, we experimented and analyzed about electric fire risk assessment methods of LED lightings for outdoor. LED lighting is composed of AC power lines, AC/DC converter, DC power lines and LED lamps. There are some risk factors of electric fire in LED lighting such as short circuit between power lines or power line and ground, dielectric breakdown, leakage current, abnormal voltage inflow, poor contacts(connections), etc. As a result of this study, insulation coverings of wire was ignited due to dielectric breakdown between power lines and molten marks were formed in copper conductor. LED lighting was blown out while short circuit, beside that, electrical disorder did not occur. When abnormal voltage was inflowed, electronic components such as varistor, condenser were damaged. Partial heating was produced and insulation was melted and carbonized by arc and heating while poor contacts were happened. We expect that the results of this study would be helpful for electrical safety of LED lightings for outdoor.

Terbia Addition Effects on Accelerated aging Characteristics of (Pr, Co, Cr)-doped ZnO Varistors ((Pr, Co, Cr)-doped ZnO 바리스터의 가속열화특성에 테르비아 첨가효과)

  • Nahm, Choon-Woo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.6
    • /
    • pp.508-513
    • /
    • 2007
  • The electrical properties and stability of $ZnO-Pr_6O_{11}-CoO-Cr_2O_3-based$ varistors were investigated for different $Tb_4O_{11}$ amounts in the range of $0{\sim}1.0\;mol%$. As the $Tb_4O_{11}$ amount increased, the sintered density increased in the range of $99.1{\sim}101.1%$ of theoretical density and the average grain size decreased in the range of $7.7{\sim}4.8{\mu}m$. The varistor voltage increased in the range of $280.9{\sim}715.8V/mm$ and the nonlinear coefficient increased in the range of $26.4{\sim}44.4$ with the increased of $Tb_4O_{11}$ amount. The 0.25 mol% $Tb_4O_{11}$-doped varistors exhibited the high electrical stability, with -0.1% in variation rate of varistor voltage, -0.7% in variation rate of nonlinear coefficient, and +17.4% in variation rate of leakage current for specified dc accelerated aging stress of $0.95V_{1mA}/150^{\circ}C/24h$.

DC Characteristics of n-MOSFET with $Si_{0.88}Ge_{0.12}$ Heterostructure Channels ($Si_{0.88}Ge_{0.12}$ 이종접합 구조의 채널을 이용한 n-MOSFET의 DC 특성)

  • Choi, Sang-Sik;Yang, Hyun-Duk;Han, Tae-Hyun;Cho, Deok-Ho;Lee, Nae-Eung;Shim, Kyu-Hwan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.150-151
    • /
    • 2006
  • $Si_{0.88}Ge_{0.12}$/Si heterostructure channels grown by RPCVD were employed to n-type metal oxide semiconductor field effect transistors(MOSFETs), and their electrical properties were investigated. SiGe nMOSFETs presented very high transconductance compared to conventional Si-bulk MOSFETs, regardless substantial drawbacks remaining in subthreshold-slope, $I_{off}$, and leakage current level. It looks worthwhile to utilize excellent transconductance properties into rf applications requesting high speed and amplification capability, although optimization works on both device structure and unit processes are necessary for enhanced isolation and reduced power dissipation.

  • PDF

The Effect of Cobalt Oxide Addition on Electrical and Dielectic Stability of Zinc Oxide Varistors (코발트 산화물 첨가가 산화아연 바리스터의 전기적, 유전적 안정성에 미치는 영향)

  • Nahm Choon-Woo;Yoo Dae-Hoon
    • Korean Journal of Materials Research
    • /
    • v.15 no.11
    • /
    • pp.722-729
    • /
    • 2005
  • The electrical and dielectric stability of zinc oxide-based varistors were investigated with the cobalt oxide contents in the range of $0.5\~5.0 mo\l%$. As cobalt oxide contents increased, the ceramic density increased in the range of $5.25\~5.55g/cm^3$ and the varistor voltage decreased in the range of $235.3\~86.0V$. The varistor with on addition of cobalt oxide $1.0 mol\%$ exhibited good nonlinearity. in which the nonlinear exponent is 66.6 and the leakage current is $1.2{\mu}A$. Furthermore, the varistors exhibited the highest electrical and dielectric stability, with $\%{\Delta}V_{1mA}=-1.9\%,\;\%{\Delta}{\alpha}=-10.5\%,\;\%{\Delta}I_L=+275.0\%,\;and\;\%{\Delta}tna{\delta}=+55.6\%$, under DC accelerated aging $0.95V_{1mA}/150^{\circ}C/24h$.

Design and Characteristic Analysis for High-speed Interior Permanent Magnet Synchronous Motor with Ferrite Magnet (페라이트 영구자석을 갖는 고속 매입형 영구자석 전동기의 특성해석 및 설계)

  • Park, Hyung-Il;Shin, Kyung-Hun;Yang, Hyun-Sup;Choi, Jang-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.11
    • /
    • pp.1806-1812
    • /
    • 2016
  • We propose an interior permanent magnet syhchronous motor (IPMSM) with arc-shape ferrite permanent magnets (PMs) as a substitute for the rare-earth permanent magnet, and determine its optimal design through parametric study. First, we use 2D finite element analysis to analyze 4-poles and 6-slots initial model according to performance requirements and design parameters. The current angle of the maximum average torque considered in the analysis is different compared with the current angle of the minimum torque ripple. Thus, the parametric study for optimal rotor design is performed by varying the thickness and the offset radius of the PMs according to current angle. In particular, a narrow bridge is required in conventional IPMSM for reducing flux leakage; however, the increase in cogging torque in the analysis model saturates the narrow bridge (large offset radius). Therefore, we suggest an appropriate shape considering limiting conditions such as DC link voltage, average torque, torque ripple, and cogging torque taking into account performance requirements.

Environmental Properties of ZnO Varistors with Variation of Sintering Temperature (소결온도에 따른 ZnO 바리스터의 내환경 특성)

  • Lee, Sung-Gap;Cho, Hyun-Moo;Lee, Jong-Deok;Park, Sang-Man
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.12
    • /
    • pp.1111-1116
    • /
    • 2005
  • ZnO varistor ceramics added a glass-frit 0.03 $wt\%$ were fabricated with variation of sintering temperature. The sintering temperature and time were $1125^{\circ}C\~1200^{\circ}C$ and 2 h. The average grain sizes increased and the varistor voltage decreased with increasing the sintering temperature. The values of the specimen sintered at $1200^{\circ}C$ were $23.7\;{\mu}m$ and 329 V, respectively. The leakage current of all specimens was less than $1\;{\mu}A$ at DC $82\%$ of varistor voltage. The clamping voltage ratio of the specimen sintered at $1175^{\circ}C$ was 1.37. The endurance of surge current and the deviation of varistor voltage of the specimen sintered at $1175^{\circ}C$ were 6400 $A/cm^2$ and ${\Delta}-2.81\%$, respectively. After the High Temperature Load Test(HTLT) at $85^{\circ}C$ for 1000 h, the specimen sintered at $1175^{\circ}C$ showed the lowest deviation of varistor voltage of ${\Delta}-1.92\%$.

Industry safety characteristic of Prismatic EDLCs (각형 전기이중층 커패시터의 산업 안전성)

  • 김경민;장인영;강안수
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2004.05a
    • /
    • pp.247-257
    • /
    • 2004
  • Electrodes were fabricated based on activated carbon powder BP-20, conducting agent such as Super P, vapor grown carbon fiber (VGCF) and acetylene black (AB), and the mixed binders of flexible poly(vinylidenefluoridehexafluoropropylene) [P(VdF-co-HFP)] and cross linking dispersion agent of polyvinylpyrrolidone (PVP) to increase mechanical strength. According to impedance measurement of the electrode with the addition of conducting agent, we found that it was possible to charge rapidly by the fast steady-state current convergence due to low equivalent series resistance (AC-ESR, fast charge transfer rate at interface between electrode and electrolyte and low RC time constant. The self-discharge of unit cell showed that diffusion process was controlled by the ion concentration difference of initial electrolyte due to the characteristics of Electric Double Layer Capacitor (EDLC) charged by ion adsorption in the beginning, but this by current leakage through the double-layer at the electrode/electrolyte interface had a minor effect and voltages of curves were remained constant regardless of electrode material. We found that the 2.3V/230F grade EDLC would be applied to industrial safety usage such as uninterrupted power supply (UPS) because of the constant DC-ESR by IR drop regardless of discharge current.

  • PDF

Aging Diagnosis of Underground Distribution Power Cables by Isothermal Relaxation Current Measurement Equipment (완화전류 측정에 의한 지중배전케이블의 열화진단)

  • Kim, Ju-Yong;Song, Il-Keun;Kim, Dong-Myung;Yun, Tae-Sang;Jeong, Sang-Bong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.502-505
    • /
    • 2004
  • The purpose of this experiment is to modify diagnosis criterion of isothermal relaxation current(IRC) measurement equipment which is using for distribution cable diagnosis. We're using this system for several years in the field instead of DC leakage current measurement and lots of cables were replaced. But we have to investigate on the reliability of this equipment for our cables because we didn't carried out condition assessment of extracted cables after field diagnosis by this equipment. It is important thing for cable maintenance. If the replacement criterion is improper we can not prevent failures or will waste budget on account of replacement of the sound cables. In this papar we selected field installed cables and injected silicone fluid to the cables for insulation rehabilitation. In order to prove reliability of the diagnosis equipment we compared diagnosis results and AC breakdown strength according to operating time after silicone treatment. This is the results of the field test for 1 year.

  • PDF

Aging Diagnosis and Characteristic Analysis of Distribution ,Power Cables I to Prepare Optimal Replacement Criterion (지중 배전케이블의 최적 교체기준 수립을 위한 열화진단 및 특성분석)

  • 김주용;송일근;정익중;한명관;심유종;문재덕
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.5
    • /
    • pp.258-263
    • /
    • 2004
  • The purpose of this experiment is to modify diagnosis criterion of isothermal relaxation current(IRC) measurement equipment which is using for distribution cable diagnosis. We're using this system for several years in the field instead of DC leakage current measurement and lots of cables were replaced. But we have to investigate on the reliability of this equipment for our cables because we didn't carried out condition assessment of extracted cables after field diagnosis by this equipment. It is important thing for cable maintenance. If the replacement criterion is improper we can not prevent failures or will waste budget on account of replacement of the sound cables. In this paper we selected field installed cables and injected silicone fluid to the cables for insulation rehabilitation. In order to prove reliability of the diagnosis equipment we compared diagnosis results and AC breakdown strength according to operating time after silicone treatment. This is the results of the field test for 1 year.