• Title/Summary/Keyword: DC image

Search Result 241, Processing Time 0.028 seconds

A Still Image Coding of Wavelet Transform Mode by Rearranging DCT Coefficients (DCT계수의 재배열을 통한 웨이브렛 변환 형식의 정지 영상 부호화)

  • Kim, Jeong-Sik;Kim, Eung-Seong;Lee, Geun-Yeong
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.38 no.5
    • /
    • pp.464-473
    • /
    • 2001
  • Since DCT algorithm divides an image into blocks uniformly in both the spatial domain and the frequency domain, it has a weak point that it can not reflect HVS(Human Visual System) efficiently To avoid this problem, we propose a new algorithm, which combines only the merits of DCT and wavelet transform. The proposed algorithm uses the high compaction efficiency of DCT, and applies wavelet transform mode to DCT coefficients, so that the algorithm can utilize interband and intraband correlations of wavelet simultaneously After that, the proposed algorithm quantizes each coefficient based on the characteristic of each coefficient's band. In terms of coding method, the quantized coefficients of important DCT coefficients have symmetrical distribution, the bigger that value Is, the smaller occurrence probability is. Using the characteristic, we propose a new still image coding algorithm of symmetric and bidirectional tree structure with simple algorithm and fast decoding time. Comparing the proposed method with JPEG, the proposed method yields better image quality both objectively and subjectively at the same bit rate.

  • PDF

Basic Study for the Development of Teat Cup Handling System Operated by a Robot (로봇에 의한 유두컵 착탈 시스템 개발을 위한 기초 연구)

  • 이영진;장동일
    • Journal of Animal Environmental Science
    • /
    • v.6 no.2
    • /
    • pp.105-112
    • /
    • 2000
  • The objective of this study was to determine the teat locations and to develop a teat cup handling system operated by a robot. The results of this study were summarized as follows: 1. The teat cup attaching and detaching operation system developed in this study consists of a control computer, a five-dimensional robot(PERFORMER-MK2), a DC servo gripper, a robot controller, two CCD-cameras (WV-vp410), an image grabber board(DT3153), a model cow, and a teat cup unit. 2. The coordinates of teat locations were measured by a stereo image processing unit. The error ranges of teats coordinates measured were (x, y, z) = (0.83, 1.95, 0.81) mm. When those were transferred into the Robot Coordinate System(RCS) coordinate, the total error ranges measured were x = 0.9 mm, y = 2.0 mm, z = 0.9 mm. 3. The rates of success of teat cup attaching and detaching operation by a robot system were 91.5% on average; the operation time needed were 27.8 sec. Total working hours for the teat cup handling including image processing were 86.1 sec.

  • PDF

Prediction of Mechanical and Electrical Properties of NiO-YSZ Anode Support for SOFC from Quantitative Analysis of Its Microstructure (미세조직 정량 분석을 통한 고체산화물연료전지용 NiO-YSZ 연료극 지지체의 기계적/전기적 성능 예측)

  • WAHYUDI, WANDI;KHAN, MUHAMMAD SHIRJEEL;SONG, RAK-HYUN;LEE, JONG-WON;LIM, TAK-HYOUNG;PARK, SEOK-JOO;LEE, SEUNG-BOK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.5
    • /
    • pp.521-530
    • /
    • 2017
  • Improving the microstructure of NiO/YSZ is one of several approaches used to enhance the electrical and mechanical properties of an anode support in Solid Oxide Fuel Cells (SOFCs). The aim of the work reported in this paper was to predict the relationship between these microstructural changes and the resulting properties. To this end, modification of the anode microstructure was carried out using different sizes of Poly (Methyl Methacrylate) (PMMA) beads as a pore former. The electrical conductivity and mechanical strength of these samples were measured using four-probe DC, and three-point bend-test methods, respectively. Thermal etching followed by high resolution SEM imaging was performed for sintered samples to distinguish between the three phases (NiO, YSZ, and pores). Recently developed image analysis techniques were modified and used to calculate the porosity and the contiguity of different phases of the anode support. Image analysis results were verified by comparison with the porosity values determined from mercury porosimetry measurements. Contiguity of the three phases was then compared with data from electrical and mechanical measurements. A linear relationship was obtained between the contiguity data determined from image analysis, and the electrical and mechanical properties found experimentally. Based upon these relationships we can predict the electrical and mechanical properties of SOFC support from the SEM images.

Moire Reduction in Digital Still Camera by Using Inflection Point in Frequency Domain (주파수 도메인의 변곡점을 이용한 디지털 카메라의 moire 제거 방법)

  • Kim, Dae-Chul;Kyung, Wang-Jun;Lee, Cheol-Hee;Ha, Yeong-Ho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.1
    • /
    • pp.152-157
    • /
    • 2014
  • Digital still camera generally uses optical low-pass filter(OLPF) to enhance its image quality because it removes high spatial frequencies causing aliasing. However, the use of OLPF causes some loss of detail. On the other hand, when image are captured by using no OLPF, the moir$\acute{e}$ is generally existed in high spatial frequency region of an image. Therefore, in this paper, moir$\acute{e}$ reduction method in case of using no OLPF is suggested. To detect the moir$\acute{e}$, spatial frequency response(SFR) of camera was firstly analyzed by using ISO 12233 resolution chart. Then, moir$\acute{e}$ region is detected by using the patterns that are related to the SFR of camera. next, this region is analysed in the frequency domain. Then, the moir$\acute{e}$ is reduced by removing its frequency component, which represents inflection point between high frequency and DC components. Through the experimental results, it is shown that the proposed method can achieve moir$\acute{e}$ reduction with preserving the detail.

Moving Image Compression with Splitting Sub-blocks for Frame Difference Based on 3D-DCT (3D-DCT 기반 프레임 차분의 부블록 분할 동영상 압축)

  • Choi, Jae-Yoon;Park, Dong-Chun;Kim, Tae-Hyo
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.37 no.1
    • /
    • pp.55-63
    • /
    • 2000
  • This paper investigated the sub-region compression effect of the three dimensional DCT(3D-DCT) using the difference component(DC) of inter-frame in images. The proposed algorithm are the method that obtain compression effect to divide the information into subband after 3D-DCT, the data appear the type of cubic block(8${\times}$8${\times}$8) in eight difference components per unit. In the frequence domain that transform the eight differential component frames into eight DCT frames with components of both spatial and temporal frequencies of inter-frame, the image data are divided into frame component(8${\times}$8 block) of time-axis direction into 4${\times}$4 sub block in order to effectively obtain compression data because image components are concentrate in corner region with low-frequency of cubic block. Here, using the weight of sub block, we progressed compression ratio as consider to adaptive sub-region of low frequency part. In simulation, we estimated compression ratio, reconstructed image resolution(PSNR) with the simpler image and the complex image contained the higher frequency component. In the result, we could obtain the high compression effect of 30.36dB(average value in the complex-image) and 34.75dB(average value in the simple-image) in compression range of 0.04~0.05bpp.

  • PDF

HDTV Essential Padding Area in Digital Broadcasting (디지털 방송에서 HDTV 필수 부가영역)

  • Han, Chan-Ho;Yoon, In-Seop
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.6
    • /
    • pp.853-864
    • /
    • 2017
  • HD padding area is essential redundancy in HD broadcasting. It is possible to use this padding area for the purpose of improving DTV broadcasting services. For utilization of this area, The bit of a service data was converted to black and white $8{\times}8$ block image. Converted block images are compressed with active video and are delivered to a receiver as only DC coefficients in a video stream. video quality is not effected by the proposed method, and service data was perfectly recovered in receiver without errors by using block average and threshold. The proposed utilization of HD essential padding area can possibly overcome the limited transmission stream rate with the bandwidth of HD broadcasting. If service data in transport or video stram were transferred using this padding area, it is possible to improve video quality with expanded video stream rate. Additionally, because the proposed methods are based on well-established standards, it is also useful for world-wide HD broadcasting systems such as ATSC, DVB, and IPTV.

A Study on Production of Optimum Profile Considered Color Rendering in Input Device (입력 장치에서 컬러 랜더링을 고려한 최적의 프로파일 제작에 관한 연구)

  • Koo, Chul-Whoi;Cho, Ga-Ram;Lee, Sung-Hyung
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.28 no.2
    • /
    • pp.117-128
    • /
    • 2010
  • Advancements in digital image have put high quality digital camera into the hands of many image professionals and consumers alike. High quality digital camera images consist originally of raw which have a set of color rendering operation applied to them to produce good images. With color rendering, the raw file was converted to Adobe RGB and sRGB color space. Also color rendering can incorporate factor such as white balance, contrast, saturation. Therefore, in this paper we conduct a study on production of optimum profile considered color rendering in digital camera. To do the experiment, the images were Digital ColorChecker SG target and ColorChecker DC target. A profiling tool was ProfileMaker 5.03. The results were analyzed by comparing in color gamut of $CIEL^*a^*b^*$ color space and calculating ${\Delta}E^*_{ab}$. Also results were analyzed in terms of different $CIEL^*a^*b^*$ color space quadrants based on lightness, chroma.

The Development of Signal Processing Software for Single-and Multi-Voxel MR Spectroscopy (단위용적 및 다용적 기법 자기공명분광 신호처리 분석 소프트웨어의 개발)

  • Paik, Moon-Young;Lee, Hyun-Yong;Shin, Oun-Jae;Eun, Choong-Ki;Mu, Chi-Woong
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.39 no.5
    • /
    • pp.544-555
    • /
    • 2002
  • The aim of this study is to develop the $^1H$-MRS data postprocessing software for both single-voxel and multi-voxel technique, which plays and important role as a diagnostic tool in clinical field. This software is based on graphical user interface(GUI) under windows operating system of personal computer(PC). In case of single-voxel MRS, both of raw data in time-domain and spectrum data in frequency-domain are simultaneously displayed in a screen. Several functions such as DC correction, zero filling, line broadening, Lorentz-Gauss filtering and phase correction, etc. are included to increase the quality of spectrum data. In case of multi-voxel analysis, spectroscopic image reconstructed by 3-D FFT was displayed as a spectral grid and overlapped over previously obtained T1- or T2-weighted image for the spectra to be spatially registered with the image. The analysis of MRS peaks were performed by obtaining the ratio of peak area. In single-voxel method, statistically processed peak-area ratios of MRS data obtained from normal human brain are presented. Using multi-voxel method, MR spectroscopic image and metabolite image acquired from brain tumor are demonstrated.

Performance Evaluation of Radiochromic Films and Dosimetry CheckTM for Patient-specific QA in Helical Tomotherapy (나선형 토모테라피 방사선치료의 환자별 품질관리를 위한 라디오크로믹 필름 및 Dosimetry CheckTM의 성능평가)

  • Park, Su Yeon;Chae, Moon Ki;Lim, Jun Teak;Kwon, Dong Yeol;Kim, Hak Joon;Chung, Eun Ah;Kim, Jong Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.93-109
    • /
    • 2020
  • Purpose: The radiochromic film (Gafchromic EBT3, Ashland Advanced Materials, USA) and 3-dimensional analysis system dosimetry checkTM (DC, MathResolutions, USA) were evaluated for patient-specific quality assurance (QA) of helical tomotherapy. Materials and Methods: Depending on the tumors' positions, three types of targets, which are the abdominal tumor (130.6㎤), retroperitoneal tumor (849.0㎤), and the whole abdominal metastasis tumor (3131.0㎤) applied to the humanoid phantom (Anderson Rando Phantom, USA). We established a total of 12 comparative treatment plans by the four geometric conditions of the beam irradiation, which are the different field widths (FW) of 2.5-cm, 5.0-cm, and pitches of 0.287, 0.43. Ionization measurements (1D) with EBT3 by inserting the cheese phantom (2D) were compared to DC measurements of the 3D dose reconstruction on CT images from beam fluence log information. For the clinical feasibility evaluation of the DC, dose reconstruction has been performed using the same cheese phantom with the EBT3 method. Recalculated dose distributions revealed the dose error information during the actual irradiation on the same CT images quantitatively compared to the treatment plan. The Thread effect, which might appear in the Helical Tomotherapy, was analyzed by ripple amplitude (%). We also performed gamma index analysis (DD: 3mm/ DTA: 3%, pass threshold limit: 95%) for pattern check of the dose distribution. Results: Ripple amplitude measurement resulted in the highest average of 23.1% in the peritoneum tumor. In the radiochromic film analysis, the absolute dose was on average 0.9±0.4%, and gamma index analysis was on average 96.4±2.2% (Passing rate: >95%), which could be limited to the large target sizes such as the whole abdominal metastasis tumor. In the DC analysis with the humanoid phantom for FW of 5.0-cm, the three regions' average was 91.8±6.4% in the 2D and 3D plan. The three planes (axial, coronal, and sagittal) and dose profile could be analyzed with the entire peritoneum tumor and the whole abdominal metastasis target, with planned dose distributions. The dose errors based on the dose-volume histogram in the DC evaluations increased depending on FW and pitch. Conclusion: The DC method could implement a dose error analysis on the 3D patient image data by the measured beam fluence log information only without any dosimetry tools for patient-specific quality assurance. Also, there may be no limit to apply for the tumor location and size; therefore, the DC could be useful in patient-specific QAl during the treatment of Helical Tomotherapy of large and irregular tumors.

W-Band MMIC chipset in 0.1-㎛ mHEMT technology

  • Lee, Jong-Min;Chang, Woo-Jin;Kang, Dong Min;Min, Byoung-Gue;Yoon, Hyung Sup;Chang, Sung-Jae;Jung, Hyun-Wook;Kim, Wansik;Jung, Jooyong;Kim, Jongpil;Seo, Mihui;Kim, Sosu
    • ETRI Journal
    • /
    • v.42 no.4
    • /
    • pp.549-561
    • /
    • 2020
  • We developed a 0.1-㎛ metamorphic high electron mobility transistor and fabricated a W-band monolithic microwave integrated circuit chipset with our in-house technology to verify the performance and usability of the developed technology. The DC characteristics were a drain current density of 747 mA/mm and a maximum transconductance of 1.354 S/mm; the RF characteristics were a cutoff frequency of 210 GHz and a maximum oscillation frequency of 252 GHz. A frequency multiplier was developed to increase the frequency of the input signal. The fabricated multiplier showed high output values (more than 0 dBm) in the 94 GHz-108 GHz band and achieved excellent spurious suppression. A low-noise amplifier (LNA) with a four-stage single-ended architecture using a common-source stage was also developed. This LNA achieved a gain of 20 dB in a band between 83 GHz and 110 GHz and a noise figure lower than 3.8 dB with a frequency of 94 GHz. A W-band image-rejection mixer (IRM) with an external off-chip coupler was also designed. The IRM provided a conversion gain of 13 dB-17 dB for RF frequencies of 80 GHz-110 GHz and image-rejection ratios of 17 dB-19 dB for RF frequencies of 93 GHz-100 GHz.