• 제목/요약/키워드: DC current sensor

검색결과 215건 처리시간 0.023초

태양광발전시스템용 직류 누설전류 센서 개발 (Development of DC Leakage Current Sensor for Solar Power Generation System)

  • 김희선;한송엽;한후석
    • 전기학회논문지
    • /
    • 제63권6호
    • /
    • pp.828-833
    • /
    • 2014
  • Grid connected transformerless solar power generation system is frequently used with the benefits of cost and efficiency. However, significant DC leakage current can flow from the DC line into the ground with dielectric breakdown in the transformerless solar power generation system. The leakage current occurred in the DC line causes accidents such as fire and electric shock on human. To resolve this problem, high sensitivity DC leakage current sensor is needed. But recently the studies on safety of DC line are not performed. In this paper, a high sensitivity DC leakage current sensor that can detect DC leakage current in solar power generation system, is proposed. Based on the studies, DC leakage current sensor is fabricated and characteristic tests are carried out. Finally, the accuracy of sensor performance is verified by leakage current experiments in solar power generation system.

도시철도 직류 전력량 계측을 위한 직류용 스마트미터링 시스템 개발 및 성능시험 (Development and Performance Test of DC Smart Metering System for the DC Power Measurement of Urban Railway)

  • 정호성;신승권;김형철;박종영
    • 전기학회논문지
    • /
    • 제63권5호
    • /
    • pp.713-718
    • /
    • 2014
  • DC urban railway power system consists of DC power network and AC power network. The DC power network supplies electric power to railway vehicles and the AC power network supplies electric power to station electric equipment. Recently, because of power consumption reduction and peak load shaving, intelligent measurement of regenerative energy and renewable energy adapted on DC urban railway is required. For this reason, DC smart metering system for DC power network shall be developed. Therefore, in this paper, DC voltage sensor, current sensor, and DC smart meter were developed and evaluated by performance test. DC voltage sensor was developed for measuring standard voltage range of DC urban railway, and DC current sensor was developed as hall effect split core type in order to install in existing system. DC smart meter possesses function of general intelligent electric power meter, such as measuring electricity and wireless communication etc. And, DC voltage sensor showed average 0.17% of measuring error for 2,000V/50mA, and current sensor showed average 0.21% of measuring error for ${\pm}2,000V/{\pm}4V$ in performance test. Also DC smart meter showed maximum 0.92% of measuring error for output of voltage sensor and current sensor. In similar environment for real DC power network, measuring error rate was under 0.5%. In conclusion, accuracy of DC smart metering system was confirmed by performance test, and more detailed performance will be verified by further real operation DC urban railway line test.

DC Link단 단일 전류센서에 의한 브러시리스 직류 전동기의 토크 리플 저감 (Torque Ripple Reduction of BLDG Motors Using Single DC-Link Currant Sensor)

  • 백대진;원창희;이교범;최익;송중호;유지윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.974-976
    • /
    • 2001
  • This paper presents a method to reduce commutation torque ripples occurred during commutation in brushless do motor drives using a single DC-link current sensor. In brushless dc motor drives with a single dc current sensor instead of 3-phase line current sensors, it is noted that dc-link current sensor cannot give any information corresponding to the motor currents during line current commutation intervals. A new technique to resolve such a problem is dealt with based on a deadbeat current control in which motor armature voltage command is computed from a dc-link current reference, an actual current and counter emf voltage. The simulation results show that the proposed method reduces the torque ripple significantly.

  • PDF

DC전류검출기의 감도개선을 위한 자계변조 (Magnetic Modulation for the Improvement of sensitivity in DC Current sensor)

  • 이환;김한성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.791-793
    • /
    • 1993
  • The hall sensor is current detector using hall effect in semiconductor and the conventional type detect current with concentrating flux by current of conductor. So, detection of small current is very difficult because of residual magnetism. This paper give the experiments based results about method that detect the small DC current using minimizing the residual of hall element by magnetic modulation and concentrating flux. The suggested sensor can dector small current better than the conventional that.

  • PDF

Design and simulation of resonance based DC current sensor

  • Santhosh Kumar, B.V.M.P.;Suresh, K.;Varun Kumar, U.;Uma, G.;Umapathy, M.
    • Interaction and multiscale mechanics
    • /
    • 제3권3호
    • /
    • pp.257-266
    • /
    • 2010
  • A novel resonance based proximity DC current sensor is proposed. The sensor consists of a piezo sensed and actuated cantilever beam with a permanent magnet mounted at its free end. When the sensor is placed in proximity to a wire carrying DC current, resonant frequency of the beam changes with change in current. This change in resonant frequency is used to determine the current through the wire. The structure is simulated in micro and meso scale using COMSOL Multi physics software and the sensor is found to be linear with good sensitivity.

클램프 형 직교류 저 전류 측정 센서 (A Clamp Type Sensor for AC/DC Low Current Measurement)

  • 박영태;유광민
    • 한국전기전자재료학회논문지
    • /
    • 제15권12호
    • /
    • pp.1045-1053
    • /
    • 2002
  • This paper describes characteristics of the developed current sensor by means of two identically wound magnetic cores forming a clamp like for measurement of a low DC, or AC current. This sensor consists of peak value detectors, a sensor of an electrically compensated current transformer type, a reference alternating voltage, Precision measuring circuits to measure the output signals of sensor with harmonics, and can be measured up to 2 A at DC, or AC current. The current sensor shows a measurement accuracy of less than 0.3% in the frequency range 40 Hz - 10 HBz. The resolution and sensitivity of the sensor were evaluated 0.1 mA and 10 mV/mA, respectively.

DC 전류검출기의 감도 개선을 위한 새로운 자기변조 (A New Magnatic Modulation for Improving Sensitivity of DC Current Sensor)

  • 김한성;이환
    • 대한전기학회논문지
    • /
    • 제43권2호
    • /
    • pp.268-277
    • /
    • 1994
  • Current sensor using Hall device is an instrument of detecting a current by Hall effect. The existing current sensor is ordinarily worked by concentrating electromagnetism produced around the conducting wire turned iron core. The tiny curren, however, could not be accurately detected by the instrument owing to influence of residual magnetism exisisting in iron core, and the result of detecting is also somewhat on the large side. kAccordingly, We fabricated a new type of instrument minimizing the influence of residual magnetism existing in iron core and detected the tiny DC current accurately by taking advantage of magnetic modulation. The range of measuring DC current is 0[mA]-100[mA] and the maxiumm Linerity tolleance by the result of detecting current, can be reduced less than 3 percent.

  • PDF

무변압기형 태양광 인버터의 출력 전류 DC offset 제거 방법 (Output Current DC offset Removal Method for Trans-less PV Inverter)

  • 홍기남;최익;최주엽;이상철;이동하
    • 한국태양에너지학회 논문집
    • /
    • 제32권spc3호
    • /
    • pp.255-261
    • /
    • 2012
  • Since PV PCS uses output current sensor for ac output current control, the sensor's sensing value includes unnecessary offset inevitably. If PV inverter is controlled by the included offset value, it's output current will generate DC offset. The DC offset of output current for trans-less PV inverter is fatal to grid, which results in saturating grid side transformer. Usually DSP controller of PV inverter reads several times sensing value during initial operation and, finally, it's average value is used for offset calibration. However, if temperature changes, the offset changes, too. And also, the switch device is not ideal, both each switching element of the voltage drop difference and on & off time delay difference generate DC offset. Thus, to compensate for deadtime and the switch voltage drop, feedback control by output current DC offset should be provided to compensate additional distortion of the output current. The validity of the proposed method is confirmed through PSIM simulation.

A Phase Current Reconstruction Technique Using a Single Current Sensor for Interleaved Three-phase Bidirectional Converters

  • Lee, Young-Jin;Cho, Younghoon;Choe, Gyu-Ha
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권4호
    • /
    • pp.905-914
    • /
    • 2016
  • This paper proposes a new phase current reconstruction technique for interleaved three-phase bidirectional dc-dc converters using a single current sensor. In the proposed current reconstruction algorithm, a single current sensor is employed at the dc-link, and the dc-link current information is sampled at either the peak or valley point of the pulse-width modulation (PWM) carriers regularly. From the obtained current information, all phase currents are reconstructed in a single PWM cycle. After that, the digital current controller is applied to achieve current balancing in each phase. Compare to the previous multiple current sensor method, the proposed strategy reduces the number of the current sensors in the interleaved three-phase bidirectional converter as well as reducing potential current sensing error caused by non-ideal characteristics of the multiple current sensors. The effectiveness of the proposed method is verified from the experiments based on a 3kW three-phase bidirectional converter prototype for the automotive battery charging application.

자동차용 DC Current Sensor의 자장해석 및 코어 최적형상 설계에 관한 연구 (A Study on the Magnetic Field Analysis and Optimal Core Design of DC Current Sensor for Vehicles)

  • 이희성;박종민;김춘식;김성관
    • 한국자동차공학회논문집
    • /
    • 제17권5호
    • /
    • pp.74-83
    • /
    • 2009
  • Recently, usage of electric and electronic system for car increases rapidly. Consequently power monitoring supplied to the system is essential for management and controlling. Generally, battery status is monitored through measuring and diagnosing the current measurement method utilizing Hall Effect. Therefore, in this paper, we analysed magnetic field to develop the solution of DC current sensor using Hall Effect which is the core of design and development. By analysing the magnetic field by FEM using Maxwell 3D software, the location of the highest output current and stable part in the Hall IC sensor was shown. Also, the optimal core design of DC current sensor using parametric and Simplex method was presented. A car battery charge and discharge process dependant on time effect on the changing of magnetic field was simulated and compared to the result from the experiment result of actual vehicle.