• 제목/요약/키워드: DC current measurement

검색결과 232건 처리시간 0.032초

자동차 Power Seat 용 DC Motor의 소음 진동 자동 평가에 대한 연구 (Automatic Measurement of Noise and Vibration for Power seat DC motor in the vehicle)

  • 한형석;정의봉;김건혁;송도훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.1142-1147
    • /
    • 2002
  • For the evaluation of the DC motor noise and vibration, usually it is rely on human feeling because some kinds of noise are not definitely represented by measurement Instrument such as sound meter. But when we consider time signal of the noise and vibration. It is possible to represent them. And in this paper. it is suggested to study output current shape of the motor because it Is the source to make speed and torque variation of the motor. If the current shape is not stable. it makes operating state of the motor unstable and produces noise and vibration. By analyzing signal at time and frequency of noise and vibration and current shape. it is possible to automation of the noise and vibration measurement in the Production line.

  • PDF

3상 인버터의 DC 링크 커패시터 전류의 센서리스 측정 (Sensorless measurement of the DC link capacitor current of three-phase inverter)

  • 수효동;정영국;임영철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 추계학술대회 논문집
    • /
    • pp.205-206
    • /
    • 2012
  • A general method to measure the inverter DC bus capacitor current is described. It is an indirect estimated method. By measuring the input and out voltage and current can calculate DC bus capacitor current. This paper will develope the theory that describes the indirect method. It will discuss and verify the feasibility of this approach through the use of the PSIM. Using SPWM control method will be simulated and compared.

  • PDF

동력의지를 위한 BLDCM 구동 시스템 및 상전류 추정 기법 (A Brushless DC Motor Drive System and Phase Current Estimation Method For Active Knee Prothesis)

  • 남기준;최연범;정두희
    • 재활복지공학회논문지
    • /
    • 제7권2호
    • /
    • pp.7-12
    • /
    • 2013
  • 본 논문에서는 동력의지를 위한 브러쉬리스 DC 모터 구동 시스템과 DC 링크단의 전류를 이용하여 상전류를 추정하는 기법을 제안한다. 토크제어를 위해서는 전류 측정이 매우 중요하며 전류 측정 시 스위칭 노이즈를 최소화하기 위해 전류 센싱 시점은 스위칭 전압 명령에 동기화 되어야 한다. 저가의 시스템, 공간의 절약 그리고 제어의 단순화하기 위해 DC 링크단 전류를 사용한 제어를 실시하였다. 또한 환류 다이오드를 통해 흐르는 전류에서 발생하는 DC 링크단 전류와 상전류간의 오차를 줄이기 위해 Analog MUX를 이용한 상전류 추정방법을 사용하였다. 실험 결과를 통해 제안한 시스템의 유효성을 검증하였다.

  • PDF

새로운 측정방법을 이용한 바이폴라 트랜지스터에서의 직류 및 교류 전류 편중 효과에 관한 해석 (The Analysis of DC and AC Current Crowding Effects Model in Bipolar Junction Transistors Using a New Extraction Method)

  • 이흥수;이성현;김봉렬
    • 전자공학회논문지A
    • /
    • 제31A권8호
    • /
    • pp.46-52
    • /
    • 1994
  • DC and AC current crowding effects for microwave and high speed bipolar transistors are investigated in detail using a new and accurate measurement technique based on Z-parameter equationa. Using the new measurement technique dc and ac current crowding effects have been explained clearly in bipolar junction transistors. To model ac crowding effects a capacitive element defined as base capacitance (C$_b$), called ac crowding capacitance is added to base resistance in parallel thereby treating the base resistance(R$_b$) as base impedance Z$_b$. It is shown that base resistance decreases with increasing collector current due to dc current crowding and approaches to a certain limited value at high collector current due to current crowding and approaches to a certain limited value at high collector currents regardless of the emitter size. It is also observed that due to ac current crowding base capacitance increases with increasing collector current. To quantigy the ac crowding effects for SPICE circuit simulation the base capacitance(C$_b$) including the base depletion and diffusion components has been modeled with an analytical expression form.

  • PDF

경락노선상 직류 전위 측정에서의 문제점 (The Problems in the Measurement of DC Potential on Meridian Skin Area)

  • 허익범;이우철;이유정;인창식
    • 대한한의진단학회지
    • /
    • 제9권1호
    • /
    • pp.131-135
    • /
    • 2005
  • Background and purpose: The measurement of direct current (DC) potential on skin area of meridian has recently been adopted to explore the electrophysiological characteristics of meridian system, But there exists two problems to be explained; the entity of the DC potential to be measured and the characteristics of electrode gel interface of measurement system, It is not clear whether the DC potential reflect, at least hypothetically, the entity of meridian, and if there exist any unstable factor in the DC potential measurement system. Methods: In this study, we designed an electronic circuit model of skin and applied known DC potential sources $({\pm}10.75mV,\;0mV)$ to the electrode interface of the skin model. Results: The result showed that the measured DC potential changed according to the time, and the same phenomenon was observed when the electrode gel was replaced with an electric condenser. It is suggested that the measurement of DC potential on electrode gel interface is very difficult and produces unstable values due to the capacity effect of electrode gel. Conclusion: Further studies on the DC potential evaluation in the context of meridian study should consider and bypass this problem.

  • PDF

Selective detection of AC transport current distributions in GdBCO coated conductors using low temperature scanning Hall probe microscopy

  • Kim, Chan;Kim, Mu Young;Park, Hee Yeon;Ri, Hyeong-Ceoul
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제19권1호
    • /
    • pp.26-29
    • /
    • 2017
  • We studied the distribution of the current density and its magnetic-field dependence in GdBCO coated conductors with AC bias currents using low temperature scanning Hall probe microscopy. We selectively measured magnetic field profiles from AC signal obtained by Lock-in technique and calculated current distributions by inversion calculation. In order to confirm the AC measurement results, we applied DC current corresponding to RMS value of AC current and compared distribution of AC and DC transport current. We carried out the same measurements at various external DC magnetic fields, and investigated field dependence of AC current distribution. We notice that the AC current distribution unaffected by external magnetic fields and preserved their own path on the contrary to DC current.

직류전기철도에서의 실시간 누설전류 계측기법에 관한 조사분석 (Investigation of the real time stray current monitoring techniques on the DC railway system)

  • 정호성;한문섭;박영;김형철;김진호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 에너지변화시스템부문
    • /
    • pp.201-203
    • /
    • 2009
  • This paper presents the real time stray current monitoring techniques on the DC railway system. These techniques are two types. The first one is the rail potential measurement technique between running rail and earthing mats on the important locations such as substation, station, and so on. And the second one is measurement technique of stray current through substation earthing mats and from collection mats, and continuous monitoring of return currents through the running rails. We need to apply these techniques on DC railway system to monitor stray current periodically and maintain the system properly.

  • PDF

DC-DC 컨버터의 고속 손실측정과 분석을 위한 PC 기반 계측시스템 (A PC-based instrumental system for fast measurement and analysis of power losses in DC-DC converter)

  • 안태영;주정규
    • 전력전자학회논문지
    • /
    • 제8권6호
    • /
    • pp.569-575
    • /
    • 2003
  • 본 논문에서는 스위칭 전원장치의 효율을 높은 정밀도로 측정하고 분석학 수 있는 PC 기반 가상계측 기를 구성하여 운용한 결과를 보고한 것이다. 고전압 저전류 방식에 적합한 간접 측정방식과 저전압 대전류 전원장치에 적합한 직접 측정방식의 비교를 수행하였으며, 직접 측정방식에서는 측정 편차를 최소화시키기 위해서 보상 기능을 추가하였다. 구성된 가상계측기의 성능을 검증하기 위해서 50W급 통신기용 전원장치를 대상으로 특성을 계측하였다. 그 결과 기존의 방법에 비해서 전원장치의 정상상태 특성을 정확하게 평가할 수 있으며, 반복 측정 오차를 줄일 수 있을 뿐만 아니라, 실시간 측정이 가능하며, 측정 시간도 절약할 수 있었다.

부하변동에 강인한 DC/DC 승압 컨버터의 잔류 추정 (Robust Current Estimation of DC/DC Boost Converter against Load Variation)

  • 김인혁;정구종;손영익
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.2038-2040
    • /
    • 2009
  • This paper studies the state estimation problem for the current of DC/DC boost converters with parasitic inductor resistance. The parasitic resistance increases the system uncertainty when the output load variation occurs. In order to enhance the observation performance of the Luenberger observer this paper includes the integral of the estimation error signal to the estimation algorithm. By using the proposed PI observer the converter current signal is successfully reconstructed with the voltage measurement regardless of the load uncertainty. Computer simulation has been carried out by using Simulink/Sim Power System. Simulation results show the proposed method maintains robust estimation performance against the model uncertainty.

Fabrication and statistical characterization of Nb SQUID sensors for multichannel SQUID system

  • Kim, B.K.;Yu, K.K.;Kim, J.M.;Kwon, H.;Lee, S.K.;Lee, Y.H.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권4호
    • /
    • pp.62-66
    • /
    • 2020
  • We fabricated superconducting quantum interference devices (SQUIDs) based on Nb Josephson junctions, and characterized the key parameters of the SQUIDs. The SQUIDs are double relaxation oscillation SQUIDs (DROSs) having larger flux-to-voltage transfer coefficient than the standard DC-SQUIDs. SQUID sensors were fabricated by using Nb junction technology consisted of a DC magnetron sputtering and a conventional photolithography process. In multichannel SQUID systems for whole-head magnetoencephalography measurement with a helmet-type SQUID array, we need about 336 SQUID sensors for each system. In this paper, we fabricated a few hundred SQUID sensors, measured the critical current, flux modulation voltage and decided if each tested SQUID can be used for the multichannel systems. As the criterion for the acceptance of the sensors, we chose the critical current and amplitude of the modulation voltage to be 8 ㎂ and 80 ㎶, respectively. The average critical current of the SQUIDs was 10.58 ㎂. The typical flux noise of the SQUIDs with input coil shorted was 2 μΦ0/√Hz at white region.