• Title/Summary/Keyword: DC Voltage unbalance

Search Result 69, Processing Time 0.041 seconds

Interlinking converter considering 1-phase short circuit state of AC-DC microgrid system (AC-DC 마이크로그리드의 각상 1선지락 상태를 고려한 인터링킹 컨버터)

  • Kim, Mi-Na;Choi, Bong-Yeon;Kang, Kyung-Min;Lee, Hoon;An, Chang-Gyun;Won, Chung-Yeun
    • Proceedings of the KIPE Conference
    • /
    • 2019.11a
    • /
    • pp.148-149
    • /
    • 2019
  • Voltage unbalance can be occured in AC-DC microgrid systems when AC loads or AC systems are connected. To solve this problem, 3-phase 4-wire interlinking converter is used. This paper proposes in PLL method that can detect accurate phase and voltage magnitude.

  • PDF

A Study of Two Phase Chopper System with Four Separate Groups of DC Motors in Powering (타동용 4 분제 2상쵸퍼방식의 특성)

  • 정연택;한경희;김용주;이영일;오봉환
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.3
    • /
    • pp.171-178
    • /
    • 1987
  • A study of two phase chopper system with four separate groups of DC motors in powering. A novel two phase chopper system with four separate groups of DC motors which applies the principles of two phase chopper with two separate groups of DC motors is dealt with this article. The main circuit consists of eight sets of chopping parts, four diodes and four separate groups of DC motors. Four groups of DC motors are driven through the series and parallel connections to each other in accordance with the operating conditions of the choppers. Although the proposed chopper circuit requires more circuit elements than the conventional two phase chopper system with combined output or two phase chopper system with two separate groups of DC motors, it has the following advantages` (1). It is possible to drive twice as much motors as conventional system does, using esisting receiving-and equipments and motors. (2). It is possible to control load voltage continuously from 0 to source voltage by changing time-ratio from 0 to 1. (3). Load current division becomes equalized. Therefore it is possible to drive not only series motors but also shunt and separately exited motors. (4). When smoothing reactor L is small, harmonic components of the proposed circuit is not so large. Therefore, the value of L can be determined from viewpoints of allowable value of ripple-ratio and current unbalance factor.

Research on the Mechanism of Neutral-point Voltage Fluctuation and Capacitor Voltage Balancing Control Strategy of Three-phase Three-level T-type Inverter

  • Yan, Gangui;Duan, Shuangming;Zhao, Shujian;Li, Gen;Wu, Wei;Li, Hongbo
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.6
    • /
    • pp.2227-2236
    • /
    • 2017
  • In order to solve the neutral-point voltage fluctuation problem of three-phase three-level T-type inverters (TPTLTIs), the unbalance characteristics of capacitor voltages under different switching states and the mechanism of neutral-point voltage fluctuation are revealed. Based on the mathematical model of a TPTLTI, a feed-forward voltage balancing control strategy of DC-link capacitor voltages error is proposed. The strategy generates a DC bias voltage using a capacitor voltage loop with a proportional integral (PI) controller. The proposed strategy can suppress the neutral-point voltage fluctuation effectively and improve the quality of output currents. The correctness of the theoretical analysis is verified through simulations. An experimental prototype of a TPTLTI based on Digital Signal Processor (DSP) is built. The feasibility and effectiveness of the proposed strategy is verified through experiment. The results from simulations and experiment match very well.

A New High Efficiency DC/DC Converter with Wide ZVS Range (넓은 영전압 스위칭 범위를 갖는 새로운 고효율 DC/DC 컨버터)

  • Park Ki-Bum;Kim Chong-Eun;Moon Gun-Woo;Yoon Myung-Joong
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.364-368
    • /
    • 2004
  • A new high efficiency DC/DC converter is proposed, which is derived from the conventional half-bridge converter. The proposed converter has good ZVS condition compared with the conventional half-bridge converter, and shows a high efficiency by solving the unbalance voltage stress and current stress problem of secondary rectifier diode of the conventional half-bridge converter. In this paper, the basic operations of the proposed converter is analyzed compared with that of the conventional half-bridge converter, and the excellent performance of the proposed converter is verified by the experimental results with the 42W prototype of the power supply for PDP Sustain Driver.

  • PDF

Compensation of Unbalanced Capacitor Voltage for Four-switch Three-phase Inverter Using DC Offset Current Injection (DC 오프셋 전류 주입에 의한 4-Switch 3-Phase Inverter의 커패시터 전압 불평형 보상)

  • Park, Young-Joo;Son, Sang-Hun;Choy, Ick
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.3
    • /
    • pp.365-373
    • /
    • 2015
  • The performance of 4-switch 3-phase inverter(FSTPI) is mainly affected by the unbalanced voltages between two capacitors which replace two switches of conventional 6-switch 3-phase inverter(SSTPI). This paper proposes a DC offset current injection method to compensate the capacitor voltage unbalance for FSTPI. A simplified SVPWM method which can be applied to FSTPI is also proposed. The validity of the proposed methods is verified by computer simulation.

Adaline-Based Control of Capacitor Supported DVR for Distribution System

  • Singh, Bhim;Jayaprakash, P.;Kothari, D.P.
    • Journal of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.386-395
    • /
    • 2009
  • In this paper, a new control algorithm for the dynamic voltage restorer (DVR) is proposed to regulate the load terminal voltage during various power quality problems that include sag, swell, harmonics and unbalance in the voltage at the point of common coupling (PCC). The proposed control strategy is an Adaline (Adaptive linear element) Artificial Neural Network (ANN) and is used to control a capacitor supported DVR for power quality improvement. A capacitor supported DVR does not need any active power during steady state because the voltage injected is in quadrature with the feeder current. The control of the DVR is implemented through derived reference load terminal voltages. The proposed control strategy is validated through extensive simulation studies using the MATLAB software with its Simulink and SimPower System (SPS) toolboxes. The DVR is found suitable to support its dc bus voltage through the control under various disturbances.

Regeneration inverter system for DC traction system (직류 지하철 급전시스템용 회생인버터 시스템)

  • Cho, Kee-Hyun;Jang, Su-Jin;Kim, Jong-Yoon;Won, Chung-Yuen;Kim, Yong-Ki
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.28-32
    • /
    • 2007
  • In this paper, a unified regenerative inverter and control algorithm are proposed in order to perform regenerative action and active power filter action. While the regenerative mode of traction, it works as regenerative inverter to reduce a excessive power of DC bus line and the powering mode of the traction, it works as active power filter to compensate ac current distortion, power factor, and voltage unbalance. In the paper, a regeneration inverter used PWM DC/AC inverter algorithm. And an active power filter used p-q theory. We are carrying out a mode analysis of DC traction system similar to actual system with MG-set and experimenting with prototype model. Through the simulation and experiment, we were proving the regeneration inverter operation which suggested in this paper.

  • PDF

Development of Control Algorithm for Improving Stability and Compensating Voltage Unbalance of Bipolar-type DC micro-grid (바이폴라 타입 DC 마이크로그리드의 전압 불평형 보상 및 안정도 향상을 위한 제어기법 개발)

  • Kim, Hyun-Jun;Lee, Ji-Heon;Han, Tae-hee;Han, Byung-Moon;Kim, Ju-Yong;Chae, Woo-Kyu
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.343-344
    • /
    • 2013
  • 본 논문에서는 바이폴라 타입 DC 마이크로그리드의 전압 불균형을 보상하기 위한 전압 밸런싱 기법과 안정도 향상을 위한 제어기법을 제안하였다. 선로 임피던스와 부하 불균형에 의한 전압 불평형 문제를 해석하고 제안하는 기법을 통해 이를 해결하였으며 과도 상태에 대한 DC 배전계통의 안정도 향상기법을 개발하였다. 제안하는 시스템의 동작 타당성을 체계적으로 분석하기 위해 PSCAD/EMTDC 소프트웨어를 이용한 시뮬레이션 모델을 개발하고 그 성능을 검증하였다.

  • PDF

A Study on DC-Link Voltage Unbalance of Three-Level Rectifier Connected with Serial Input Parallel Output LLC Converter (직렬 입력 병렬 출력 LLC 컨버터가 연결된 3레벨 정류기의 DC-Link 전압 불평형에 관한 연구)

  • Baek, Seung-Woo;Kim, Hag-Wone;Cho, Chun-Soo
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.391-392
    • /
    • 2020
  • 본 논문은 3레벨 정류기와 직렬 입력, 병렬 출력 LLC 컨버터가 연결된 전원 장치의 DC-Link 전압 불평형 제어에 관해 분석한다. 일반적으로 380Vac 입력을 가지는 3레벨 부스트 기반 정류기는 출력 전압을 700Vdc 이상으로 제어한다. 또한, 3레벨 컨버터는 두 개의 직렬 출력 커패시터를 가지며, 불균형 해소를 위한 제어 또는 물리적 불평형 해소 소자가 요구된다. 스위칭 신호를 공유하는 두 개의 LLC 컨버터가 연결된 시스템에 DC-Link 불평형 전압 제어가 적용되면 전력의 쏠림 현상이 발생한다. 본 논문은 제시된 시스템에서 전력의 쏠림 현상에 대해 그 원인을 분석하고 실험으로 검증한다.

  • PDF

Current Control for Three Phase PWM Converter Using LQ Controller with Conditional Integrator (조건부 적분기를 가지는 LQ 제어기를 이용한 3상 PWM 컨버터의 전류제어)

  • 김홍성;전윤석;조영준;목형수;최규하;김한성
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.345-351
    • /
    • 1997
  • In this paper, controller for PWM converter considering unsymetrical input voltage is designed and current controller using LQ controller with conditional integrator is proposed. And the proposed current controller is compared with other current controller-predictive controller, decoupling PI controller. As simulation results, LQ controller with Conditional Integrator shows the improved performance for DC link voltage regulation through transient test of load variation. And when unsymeritrical input voltage is applied to converter with conventional current controller considering only symetrical input voltage, input current is distorted but it is showed that current controller considering unsymetrical input has robust control characteristics under phase voltage unbalance.

  • PDF