• 제목/요약/키워드: DC Cable

검색결과 128건 처리시간 0.025초

Reduced Switch Count Topology of Current Flow Control Apparatus for MTDC Grids

  • Diab, Hatem Yassin;Marei, Mostafa Ibrahim;Tennakoon, Sarath B.
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1743-1751
    • /
    • 2016
  • The increasing demand for high voltage DC grids resulting from the continuous installation of offshore wind farms in the North Sea has led to the concept of multi-terminal direct current (MTDC) grids, which face some challenges. Power (current) flow control is a challenge that must be addressed to realize a reliable operation of MTDC grids. This paper presents a reduced switch count topology of a current flow controller (CFC) for power flow and current limiting applications in MTDC grids. A simple control system based on hysteresis band current control is proposed for the CFC. The theory of operation and control of the CFC are demonstrated. The key features of the proposed controller, including cable current balancing, cable current limiting, and current nulling, are illustrated. An MTDC grid is simulated using MATLAB/SIMULINK software to evaluate the steady state and dynamic performance of the proposed CFC topology. Furthermore, a low power prototype is built for a CFC to experimentally validate its performance using rapid control prototyping. Simulation and experimental studies indicate the fast dynamic response and precise results of the proposed topology. Furthermore, the proposed controller offers a real solution for power flow challenges in MTDC grids.

직류 전력케이블용 반도전 복합체의 열적 특성 (Thermal Properties of Semiconductive Composites for DC Power Cable)

  • 이기정;서범식;양종석;성백룡;박대희
    • 한국전기전자재료학회논문지
    • /
    • 제26권1호
    • /
    • pp.49-55
    • /
    • 2013
  • In this paper, semiconducting shield specimens for a DC cable os fabricated and characterized by measurement of volume resistance, tensile strength, and the coefficient of expansion to show the electrical and mechanical characteristics of the semiconducting shield. Due to the PTC phenomenon, the volume resistance at $25^{\circ}C$ increases rapidly in comparison to the volume resistance at $90^{\circ}C$. Since the compounding ration of carbon black is low, the tensile strength and density become lower and the coefficient of expansion is increased. As the general specification of the tensile strength and density is $0.8kgf/mm^2$ and 150%, respectively, the fabricated specimen in this paper has excellent mechanical characteristic.

고주파 성형 재료용 폴리에칠렌의 절연 신뢰도 분석 (An Analysis of Insulating Reliability in Polyethylene for High Frequency Molding Materials)

  • 박건호;김기준;왕종배;신철기;김진사;이준웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 제2회 학술대회 논문집 일렉트렛트 및 응용기술전문연구회
    • /
    • pp.64-67
    • /
    • 2000
  • In this study, the DC dielectric breakdown of polyethylene used for clothing material of cable was experimented and then its data were simulated by Weibull distribution probability. The dielectric breakdown characteristics in polyethylene were examined and various effects of the DC dielectric breakdown on polyethylene were also discussed.

  • PDF

외부자계 영향에 따른 HTS 선재의 직$\cdot$교류 통전 특성 (DC and AC current transport characteristics of HTS tapes with external magnetic field)

  • 임성우;최용선;최효상;황시돌;정영호
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.15-18
    • /
    • 2003
  • HTS(High Temperature Superconductor) tapes have dependence on critical characteristics such as electric, magnetic field and temperature. In order to confirm these effects, we examined the current transport characteristics of HTS tapes. First, after being fed DC and AC, the dependence of HTS tapes of 10cm on external magnetic field was investigated. On centeral region of HTS tape, about 1cm, external magnetic field was applied. Second, after applying DC of 50A to HTS tapes, we applied time variable magnetic field about 100mT and investigated the quench characteristics. Finally, AC, which is about 10 times of I$_{c}$, was applied to HTS tapes and over current characteristics were investigated. The data acquired in this study will be used as a source for the study of HTS cable conductor which is supposed to carry on.n.

  • PDF

발전소 직류 제어회로 과도현상 분석 및 보조계전기 선정 적합성 검토 (A Analysis of DC Control Circuit Transient and a Study of Auxiliary Relay Design Compatability in the Power Plant)

  • 선현규;홍영희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1948_1949
    • /
    • 2009
  • All the power generating station require dc auxiliary power systems to operate those dc components that must be available if a loss of ac power occur. Some examples of such components are auxiliary motors, circuit breakers, relays and solenoids. The dc source may be one common battery for both power and control or two separate batteries; one for power and another for control. Typically, a dc auxiliary power system is designed as an ungrounded system, instead of grounded system, so that a low-resistance ground fault on one of its two polarities will not affect the operation of the system, thus increasing system reliability and continuity of service. A ground detector should provide a high polarity-to-ground resistance so that a single ground fault occurring on the system will not affect the operation of that system. Sensitive relays have been known to energize momentarily while the cable and capacitive charge to ground shifts[1]. A power station had experienced this kind of incident and performed root cause analysis based on PC based simulation program known as PSpice. This simulation showed adapted relays on the system energize momentarily and design criteria on this relay should be corrected.

  • PDF

온도 및 절연체에 따른 케이블의 단선시간 특성 해석 (Fusing Time Characteristics Analysis of Cable according to Temperature and Insulator)

  • 김주희;강신동;김재호
    • 한국안전학회지
    • /
    • 제33권5호
    • /
    • pp.15-20
    • /
    • 2018
  • This paper describes the fusing time characteristics of Light PVC Sheathed Circular Cord(VCTF) and Tray Frame Retardant(TFR) cables according to increased temperature under over current condition. The experimental equation will be used to determine the validity and reliability of the test results. The over current flowed 3, 5 and 10 times higher than the amount of allowable current using DC power supply with DAQ(Data Acquisition) measurement system. An infrared radiation heater, which was controlled by a variable AC auto transformer, was used to increase the temperature from room temperature to 50, 100 and 150 degrees Celsius. First, two type of cables were analyzed those with different cross-sectional areas with in the same structure and those with different structures with in the same cross-sectional areas. Then, it was determined how fusing time had been influenced according to the cross-sectional areas and different structures, respectively. The cable resistance was increased by joule heating according to increasing temperature. Therefore, the allowable current of cable is decreased. Finally, the fusing time of the cable was decreased due to increased temperatures at current flow, which were 3 times the amount of allowable current. The instantaneous breakdown was observed when current flow was 5 and 10 times over the amount of allowable current. The fusing time is directly affected by the structure of cable insulation.

계측시스템을 활용한 틸팅열차 추진장치 특성 연구 (A Study on TTX Traction Characteristics using Measurement System)

  • 한영재;이수길;박춘수;한성호;이준석;정권일
    • 한국전기전자재료학회논문지
    • /
    • 제20권12호
    • /
    • pp.1093-1098
    • /
    • 2007
  • Tilting trains are currently in operation in 13 countries around the world. With the advances in tilting technology, verification of economic efficiency, and changes in economic situations, the introduction of tilting trains will rapidly spread across the globe. The measurement system is composed of the industrial computers installed in the console and the measurement racks mounted on each car. It is utilized to accumulate the data by the communication card and the optical cable. The optical cable and power cable are coupled at the connector located in joint of train to make easy to disconnect car each other. The signal conditioner is designed to choose and to extend the channel for each sensor readily. The sensor measurement rack has adopted as decentralization method. It is installed in each car to minimize the cable length. In also, it is manufactured based on 19"rack and covered to protect the cable. In this study, the programs for measurement and analysis were also developed to understand the traction system characteristics of TTX. Using this measurement system, we studied that acceleration test, re-powering test, and gradually powering test. The acceleration performance of TTX is 1.735 km/h/s, and it is inner standard value. The notch test result from 1 to 7 steps, DC link voltage is under standard value, and the output electric current of inverter is controlled normally. From the test results, we saw the performances of the traction systems are normal.

화력 발전소 고전압 케이블 접속재의 On-Line 직류 누설 전류 시스템 개발과 진단 Factor에 관한 연구 (A Study on Development and Diagnosis Factors of On-Line DC Leakage Current System for Junctions of High-Voltage Cables in Operation at Thermoelectric Power Station)

  • 박성희;엄기홍
    • 한국인터넷방송통신학회논문지
    • /
    • 제18권6호
    • /
    • pp.187-193
    • /
    • 2018
  • 국내에서의 전력에 대한 수요는 점진적으로 증가하고 있는 추세이다. 수요에 대응하기 위한 발전소는 기능이 다양해지고 효율이 점차 커져야 한다. 발전소 내의 전력 기기에서 사고가 발생하면 막대한 경제적 손실 및 장애를 초래하게 된다. 사고 발생의 원인 중의 하나로서 절연 성능이 저하 된 케이블이 있다. 케이블 사고를 미연에 방지하기 위하여 절연의 상태를 감시하고 확인하여야 한다. 케이블 사고는 연결 부위인 접속에서 발생하는 사고가 대부분을 차지한다. 본 연구와 관련하여 우리는 접속부 상태를 판별하기 위한 장비를 개발하였고, 한국서부발전(주)의 현장에 설치하여 운용 중이다. 본 논문에서는 현장에서 설치 운용 중인 장비에 대한 설명과 더불어 설치 운용된 결과를 통해 케이블의 수명을 예측할 수 있는 고전압 케이블 접속재의 안정적 사용을 위한 온라인 감시진단기법 중에서 사고가 가장 빈번하게 발생하는 접속부에 대해 안정적인 사용을 위한 진단의 정확성과 신뢰성을 향상시키기 위한 연구를 하였다. 이 논문에서 하드웨어 구성을 위주로 우리가 개발한 장비를 소개한다.

넓은 공극에서 강인성을 가지고 동작하는 단일전력단 무선전력전송 교류-직류 컨버터 (Single-Stage AC/DC Converter for Wireless Power Transfer Operating With Robustness in Wide Air Gaps)

  • 우정원;장기찬;김민지;김은수
    • 전력전자학회논문지
    • /
    • 제26권2호
    • /
    • pp.141-149
    • /
    • 2021
  • In the field of electric vehicles and AGVs, wireless power transfer (WPT) charging systems have been developed recently because of its convenience, reliability, and positive environmental impact due to cable and cord elimination. In this study, we propose a WPT charging system using a single stage AC-DC converter that can be reduced in size and weight and thus can ensure convenience. The proposed single-stage AC-DC converter can control a wide output voltage (36-54 VDC) within coupling ranges by using the variable link voltage applied to the WPT resonant circuit through phase-shifted modulation at a fixed switching frequency. Moreover, the input power factor and total harmonic distortion can be improved by using the proposed converter. A 1 kW prototype that can operate with an air gap range of 40-50 mm is fabricated and validated through experimental results and analysis.

지중 배전케이블의 최적 교체기준 수립을 위한 열화진단 및 특성분석 (Aging Diagnosis and Characteristic Analysis of Distribution ,Power Cables I to Prepare Optimal Replacement Criterion)

  • 김주용;송일근;정익중;한명관;심유종;문재덕
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권5호
    • /
    • pp.258-263
    • /
    • 2004
  • The purpose of this experiment is to modify diagnosis criterion of isothermal relaxation current(IRC) measurement equipment which is using for distribution cable diagnosis. We're using this system for several years in the field instead of DC leakage current measurement and lots of cables were replaced. But we have to investigate on the reliability of this equipment for our cables because we didn't carried out condition assessment of extracted cables after field diagnosis by this equipment. It is important thing for cable maintenance. If the replacement criterion is improper we can not prevent failures or will waste budget on account of replacement of the sound cables. In this paper we selected field installed cables and injected silicone fluid to the cables for insulation rehabilitation. In order to prove reliability of the diagnosis equipment we compared diagnosis results and AC breakdown strength according to operating time after silicone treatment. This is the results of the field test for 1 year.