• Title/Summary/Keyword: DC 모터

Search Result 562, Processing Time 0.023 seconds

A System Development for Remotely Controlling Windows and Doors in Mobile Environment (모바일 환경에서의 원격 창호 관제시스템 개발)

  • Cho, Yong-Hyun;Ryu, Sung-Won;Ahn, Kyung-Gyu
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.25 no.4
    • /
    • pp.334-341
    • /
    • 2015
  • This paper develops a new system for remotely monitoring and controlling the windows and doors in mobile environment. We design and implement the opening and shutting unit, the gateway, and the control server system, respectively. The opening and shutting unit consists of the driver using DC motor and the motion controller which monitors the state and transfers the control information. The gateway supports TCP/IP and CDMA protocol, which is the interface of wire and wireless communication for transferring the current state and control information. The control server consists of the program to store and process the control information, the middleware to support the processing of various state message, and DB for monitoring the state and remotely controlling the system. Especially, an application software and the Web-based user interface have also been developed to support the mobile environment. The operation performances, environment influences, driving persistences, and operation failure ratio, which are based on PC and smart-phone, have been tested in 2 authorized agencies. The test results show that the developed system has a superior performance.

A Study on Reliability Compliance Test based on Thermal Fatigue Accelerated Test for CVVL BLDC Motor (CVVL BLDC 모터의 열피로 가속시험을 통한 수명보증시험 설계)

  • Lee, San-Hoon;Park, Sang-Wook;Kim, Min-Geiun;Seon, Han-Geol;Hong, Sung Ryeul;Han, Man-Seung
    • Journal of Applied Reliability
    • /
    • v.15 no.4
    • /
    • pp.241-247
    • /
    • 2015
  • Purpose : The demand for higher fuel economy vehicles has helped develop fuel-efficient vehicles such as a CVVL called continuous variable valve lift. Existing CVVL has been applying DC type motor to control intake valve, but recently some car parts manufacturers have been developing a BLDC type CVVL motor for improvements of endurance performance. The purpose of this study is to find the potential failure mechanism of the CVVL BLDC moto in early stage of development based on the design properties and design the accelerated life test model. Methods : CVVL BLDC is consist of brushs, coil, magnetic, PCB, bearing and so on. Each component has a latent failure mechanism caused by temperature, humidity, vibration. By analysis result of the failure mechanism, thermal fatigue is the most important factor of a durability of CVVL BLDC motor. So, we designed a new accelerated life test model for guarantee of the CVVL BLDC motor. Results : A crack occurred on via hole in test using the conditions we designed, so we did change the design to avoid this failure. The via hole dimension is changed a little larger, as a result we achieve improvements in reliability of the CVVL BLDC motor. By applying various kinds and extreme level of stresses, we can find the operating limits of products. Conclusion : In thesis, We analyzed the failure mechanism of CVVL BLDC and designed an accelerated life test method to give a guarantee for reliability. Based on the test results, we could improve the reliability of developments by change of design.

A Study on an Implementation of Control Panel of Sun Trackers and Monitoring System for Photovoltaic Generation Plants (태양광발전의 태양추적기제어반 및 모니터링시스템 구현에 관한 연구)

  • Lho, Tae-Jung;Park, Min-Yong;Lee, Seung-Hyeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.9
    • /
    • pp.3161-3167
    • /
    • 2010
  • Hall sensors of BLDC(brushless DC) motor are used to detect a position information for a control mechanism, which implements an algorithm for velocity and position control. Actual azimuth and altitude were measured to evaluate a control precision. The measurement revealed comparatively good accuracy that the measured values were $2.02^{\circ}$ and $1.01^{\circ}$ respectively, and the maximum error falls within $1.86^{\circ}$. The developed monitoring system of photovoltaic generation plants is a LCU(Local Control Unit) based on an integrated monitoring system which supports 1:N method for multiple simultaneous connections, remote control and real-time system state monitoring.

Experimental Study on Meso-Scale Milling Process Using Nanofluid Minimum Quantity Lubrication (나노유체를 이용한 메소스케일 밀링 가공 특성에 관한 실험적 연구)

  • Lee, P.H.;Nam, T.S.;Li, Chengjun;Lee, S.W.
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.10
    • /
    • pp.1493-1498
    • /
    • 2010
  • This paper present the characteristics of micro- and meso-scale milling processes in which compressed cold air, minimum quantity lubrication (MQL) and $MoS_2$ nanofluid MQL are used. For process characterization, the microand meso-scale milling experiments are conducted using desktop meso-scale machine tool system and the surface roughness is measured. The experimental results show that the use of compressed chilly air and nanofluid MQL in the micro- and meso-scale milling processes is effective in improving the surface finish.

Measurements of the Pitch Dynamic Stability Derivatives of a Standard Dynamics Model Using a Forced Vibration Technique (강제진동기법을 이용한 표준동역학 모델의 피치 동안정미계수측정)

  • Cho, Hwan-Kee;Kim, Seung-Pil;Baek, Seung-Woock;Chang, Jo-Won
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.6
    • /
    • pp.489-495
    • /
    • 2007
  • An experimental study was carried out in order to measure the pitch dynamic stability derivatives of a standard dynamics model in a low-speed wind tunnel. When a trigger signal is generated, the aircraft model starts oscillation with constant amplitudes and frequencies provided by DC electrical servomotor. The measured data are simultaneously recorded on a data recorder for 25 cycles of the model oscillation. The Phase shift needed to compute the dynamic stability derivatives is determined by calculating differences between the peak values of the input and output signals from the dynamic stability balance. Stabilator effects on the stability derivatives were also investigated with deflection angles. Although the driving apparatus and experimental equipments manufactured creatively for this study are different from other experiments, the variational trend of dynamic stability derivatives with the angle of attack is in a good accordance with the results of TPI, NAE, and FFA.

Fluid Dynamic Bearing Spindle Motors for DLP (DLP용 유체동압베어링 스핀들모터)

  • Kim, Yeung-Cheol;Seong, Se-Jin
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.2
    • /
    • pp.82-90
    • /
    • 2011
  • The small precision spindle motors in the high value-added products including the visible home appliances such as DLP projector require not only the energy conversion devices but also high efficiency, low vibration and sound operation. However, the spindle motors using the conventional ball bearing and sintered porous metal bearing have following problems, respectively: the vibration by the irregularity of balls and the short motor life cycle by the ball's abrasion and higher sound noises by dry contact between shaft and sleeve. In this paper, it is proposed that the spindle motor with a fluid dynamic bearing is suitable for the motor to drive the color wheel of the DLP(digital lightening processor) in the visible home appliances. The proposed spindle motor is composed of the fluid dynamic bearing with both the radial force and the thrust force. The fluid dynamic bearing is solved by the finite element analysis of the mechanical field with the Reynolds equations. The magnetic part of spindle motor, which is a type of Brushless DC Motor, is designed by the electro-magnetic field analysis coupled with the Maxwell equation. And the load capacity and the friction loss of fluid dynamic bearing are analyzed to bearing clearance variation by the fabrication error in designed motor. The design of the proposed motor is implemented by the load torque caused by the eccentricity and the unbalance of the fluid dynamic bearing when the motors are fabricated in error. The prototype of the motor with the fluid dynamic bearing is manufactured, and experiment results show the vibration, sound, and phase current at no load and color wheel load of the motors in comparison. The high performance characteristics with the low vibration, the low acoustic noise and the optimal mechanical structure are verified by the experimental results.

A Basic Experimental Study on Performance of Proton Exchange Membrane Fuel Cell System for Vehicle (PEM 연료전지 자동차 적용을 위한 성능실험에 관한 기초연구)

  • Lee, Hyun-kun;Oh, Byeong-soo;Jeong, Kwiseong
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.11 no.3
    • /
    • pp.137-147
    • /
    • 2000
  • Not only study of fuel cell performance but study of fuel cell application is very important, therefore these studies were paralleled together for the commercialization of exciting power generation. The objective of this study is to determine the characteristics of shaft power and efficiency as a function of rpm and to compare natural convection air method to forced air method. From these results, performance of forced air was better than that of natural convection air because it enables to improve mass transportation by increasing air flow rate. With decreasing shaft power, efficiency of fuel cell decreases remarkably because dc motor drives at the low range of efficiency. Fuel cell powered vehicle has to be driven considering efficiency and shaft power. It should be driven at 35-45% of efficiency and 0.55-0.75v/cell.

  • PDF

A PID Genetic Controller Design Using Reference Model (기준모델을 이용한 PID 유전 제어기 설계)

  • Park, K.H.;Nam, M.H.;Hwang, Y.W.;Chun, S.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.894-896
    • /
    • 1999
  • PID 제어는 50년의 역사를 갖기 때문에 현장의 사용자는 이 제어방식에 익숙해져 있으며, 제어장치의 구성이 간단하며 제어기의 최적동조가 가능하므로 많은 분야에서 사용되고 있다[1]. 그러나 PID 제어기에 의해서 얻은 결과에 대하여 만족하기 위해서는 많은 시행착오를 겪어야 한다. 또한 만족하는 결과를 얻었다고 할지라도 외란, 플랜트의 동특성이 바뀌는 경우 시스템을 추종하지 못하기 때문에 파라미터를 재조정하여야 한다. 유전 알고리즘은 자연세계의 진화 현상에 기초한 계산모델로서 John Holland에 의해서 1975년에 개발된 전역적인 최적화 알고리즘이며[1][2], 비선형 고차원, 불연속, 다중모드, 노이즈 함수 등에 대하여 강건함을 보여주고, 복잡한 탐색 공간에서 최적 값을 스스로 발견하는 학습 능력을 갖는다. 이 방법은 재생산, 교배, 돌연변이를 통하여 최적해를 찾은 방법으로 1989년에 D. E. Goldgerg에 의해서 체계적으로 정리된 후 여러 분야에서 응용되고 있다[3][4]. 그러나 유전 알고리즘은 목적함수만을 이용하여 해집단을 탐색하기 때문에 숙련운전자가 원하는 제어 특성 명세인 상승시간, 정착시간, 초과량(oveshoot) 둥을 구체적으로 명시하여 제어에 반영할 수 없다. 또한, 유전 알고리즘은 입력 값이 크게 바뀔 경우 다른 시스템으로 인식하여 새로운 탐색을 수행하는 단점을 가지고 있다. 본 논문은 첫째, 기준모델을 도입하여 플랜트의 성능을 기준모델로 표현하여 플랜트가 요구하는 성능지표를 정량적으로 규정하는 것이 가능하였다. 또한, 이것은 미지 플랜트 동특성을 식별하기 위한 신호로 사용되어, 플랜트의 정보를 얻는데 이용되었다. 즉, 기준모델과 플랜트 출력사이의 추종 오차 정보가 적응기구인 PID 유전제어기의 입력으로 사용되며, 구형파 입력의 경우에도 기준모델과 플랜트의 출력차는 크게 변하지 않는다. 따라서, 유전 알고리즘의 목적함수에 기준 모델을 제안 적용하여 안정적이고, 세밀한 제어를 수행하였다. 둘째, PID의 간단하면서 확실한 제어가 가능하다는 점과 전역적인 최적값을 찾을 수 있는 유전 알고리즘을 적용하여 고속제어를 요하는 직류 서보 모터(DC Servo Motor) 운전 시 실시간 파라미터 동조에 적용하였다.

  • PDF

Fault Detection and Isolation for the Inverter of BLDC Motor Drive using EKF (EKF를 이용한 BLDC 모터 구동기 인버터의 고장 검출 및 분리)

  • Kim, SunKi;Seong, SangMan;Kang, Kiho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.7
    • /
    • pp.706-712
    • /
    • 2014
  • The inverters used to drive Brushless DC motors (BLDC) include switching devices such as FETs and the faults in FETs cause severe performance degradation in systems where a BLDC acts as actuator. This paper presents a fault detection and isolation method for the FETs of an inverter for BLDC motor control systems, which is based on the EKF (Extended Kalman filter). Firstly, an equivalent circuit model for a BLDC motor plus its inverter system was derived. Secondly, a state-space equation was established, where the on-resistance of the FETs is expressed as a state variable and the EKF equation estimates the on-resistance. If the estimated resistance differs greatly from the known value, it can be asserted that there is a fault on that FET. Thirdly, the local convergence of the established EKF was proved. Finally, through the experiments, the performance of the proposed method was verified. The results show that the on-resistance is estimated close to the value specified in the FET data sheet in normal operation, whereas the estimated resistance is a much larger value than the normal one in case an FET fault occurs. Therefore, it is confirmed that the proposed fault detection and isolation method works appropriately in real systems.

Design of a AC Magnetic Leakage Flux Scan System use in DSP (DSP를 이용한 교류누설 자속 탐상 시스템의 설계)

  • 임형석;이영훈
    • Journal of the Korea Society of Computer and Information
    • /
    • v.8 no.4
    • /
    • pp.75-80
    • /
    • 2003
  • In this paper, we designed add current scan system basically. Although NDT system using AC method in now days had problem with limit of detection rate and limit of device organization, in this paper, we made up these problem so that designed device smaller than system used, reduction of cost of system organization and precision of measuring crack. Also, AC leakage flux system had high accuracy about minute crack in the surface and advantage of designing system easily so that we designed system for concerning about crack of surface. Furthermore, it can be able to detect exact crack of reference in wide area by using DSP320C31 chip to reduce the time of measuring crack.

  • PDF