• Title/Summary/Keyword: DC/AC inverter

Search Result 458, Processing Time 0.028 seconds

Life Estimation of Electrolytic Capacitors in Inverters (인버터용 전해커페시터의 수명 추정)

  • Lee, Dong-Choon
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.243-245
    • /
    • 2000
  • In general, aluminum electrolytic capacitors are used in the DC link of PWM inverters fur ac motor drives. The capacitor usually has the shortest lifetime in the system and then determines the lifetime of the inverter system. In this paper, a method of capacitor lifetime estimation is proposed by using an ESR(equivalent series resistance) model and a heat transfer model of capacitor, from which internal operating temperature is estimated. Then, the lifetime is predicted by Arrhenius's equation. A practical example is presented.

  • PDF

A Study on the Operating Characteristics for a Grid-Connected Photovoltaic Power System (계통연계형 태양광 발전시스템의 운전특성에 관한 연구)

  • Ahn, K.S.;Hwang, I.H.;Jeong, S.J.;Lim, H.C.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2436-2438
    • /
    • 1998
  • The operating characteristics of a 3 kW grid-connected photovoltaic (PV) power system was studied by analying annual photovoltaic data. The system performance for grid connection was investigated using a DC/ AC inverter. The results of a demonstration test show that the system utilization rate is 15.6% and the system efficiency is 8.03%.

  • PDF

THERMAL SIMULATION OF PWM INVERTER (PWM 인버터의 열해석)

  • Kang H.Y.;RYU J.S.;LEE S.W.;KIM Y.G.;SONG J.G.;SHIN Y.J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.35-38
    • /
    • 2005
  • 인버터는 전기적으로 DC(직류)를 AC(교류)로 변환하는 역 변환 장치이며, 상용전원(AC 22V/440V)으로부터 공급된 전력을 입력받아 전압과 주파수를 가변시켜 전동기에 공급함으로써 전동기의 속도를 고효율로 이용하게 제어하는 장치이다. 본 논문에서는 550kW급 IGBT, DIODE의 발열에 의한 인버터 내부의 열 및 온도분포를 ICEPAK 상용코드를 통하여 수치적 해석을 수행하였다. 인버터의 발열은 캐패시터의 수명과 소자들의 오작동 등 많은 열적 문제를 가지고 있으며 Heat-sink, Fan, Duck등을 통하여 전도와 대류가 이루어지는 시스템이다. 인버터은 많은 파라미터들에 의해 온도가 결정되기 때문에 실험을 통한 해석은 제한적 일수 밖에 없다. 따라서 수치해석을 통하여 빠른 시간에 효율적인 열 설계를 할 수 있으며, 인버터의 크기는 최종적으로 Heat-sink의 형상에 따라 달라지므로 이를 최적화 하고 소형화 하는 작업이 필요하다. 인버터의 복잡한 내부구조상 하단부(발열원, Heat-sink, Fan등)만 수치해석을 수행하였을 때와 Full Model과는 $15^{\circ}C$ 온도 차이를 보였다. 최종적으로 인버터의 최적 열 설계를 위하여 Frame위치 변경, Heat-Sink 형상변화등 많은 수치해석을 통하여 만족할 만한 결과를 얻었다.

  • PDF

Design of Capacitive Power Transfer Using a Class-E Resonant Inverter

  • Yusop, Yusmarnita;Saat, Shakir;Nguang, Sing Kiong;Husin, Huzaimah;Ghani, Zamre
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1678-1688
    • /
    • 2016
  • This paper presents a capacitive power transfer (CPT) system using a Class-E resonant inverter. A Class-E resonant inverter is chosen because of its ability to perform DC-to-AC inversion efficiently while significantly reducing switching losses. The proposed CPT system consists of an efficient Class-E resonant inverter and capacitive coupling formed by two flat rectangular transmitter and receiver plates. To understand CPT behavior, we study the effects of various coupling distances on output power performance. The proposed design is verified through lab experiments with a nominal operating frequency of 1 MHz and 0.25 mm coupling gap. An efficiency of 96.3% is achieved. A simple frequency tracking unit is also proposed to tune the operating frequency in response to changes in the coupling gap. With this resonant frequency tracking unit, the efficiency of the proposed CPT system can be maintained within 96.3%-91% for the coupling gap range of 0.25-2 mm.

Voltage Dip Compensation Algorithm Using Multi-Level Inverter (멀티레벨 인버터의 순간정전 보상알고리즘에 관한 연구)

  • Yun, Hong-Min;Kim, Yong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.12
    • /
    • pp.133-140
    • /
    • 2013
  • Cascaded H-Bridge multi-level inverters can be implemented through the series connection of single-phase modular power bridges. In recent years, multi-level inverters are becoming increasingly popular for high power applications due to its improved harmonic profile and increased power ratings. This paper presents a control method for balancing the dc-link voltage and ride-through enhancement, a modified pulse width-modulation Compensation algorithm of cascaded H-bridge multi-level inverters. During an under-voltage protection mechanism, causing the system to shut down within a few milliseconds after a power interruption in the main input sources. When a power interruption occurs finish, if the system is a large inertia restarting the load a long time is required. This paper suggests modifications in the control algorithm in order to improve the sag ride-through performance of ac inverter. The new proposed strategy recommends maintaining the DC-link voltage constant at the nominal value during a sag period, experimental results are presented.

New Backstepping-DSOGI hybrid control applied to a Smart-Grid Photovoltaic System

  • Nebili, Salim;Benabdallah, Ibrahim;Adnene, Cherif
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.4
    • /
    • pp.1-12
    • /
    • 2022
  • In order to overcome the power fluctuation issues in photovoltaic (PV) smart grid-connected systems and the inverter nonlinearity model problem, an adaptive backstepping command-filter and a double second order generalized Integrators (DSOGI) controller are designed in order to tune the AC current and the DC-link voltage from the DC side. Firstly, we propose to present the filter mathematical model throughout the PV system, at that juncture the backstepping control law is applied in order to control it, Moreover the command filter is bounded to the controller aiming to exclude the backstepping controller differential increase. Additionally, The adaptive law uses Lyapunov stability criterion. Its task is to estimate the uncertain parameters in the smart grid-connected inverter. A DSOGI is added to stabilize the grid currents and eliminate undesirable harmonics meanwhile feeding maximum power generated from PV to the point of common coupling (PCC). Then, guaranteeing a dynamic effective response even under very unbalanced loads and/or intermittent climate changes. Finally, the simulation results will be established using MATLAB/SIMULINK proving that the presented approach can control surely the smart grid-connected system.

Characteristic PCS of Inverter by Boost Converter of PV Generation (태양광 발전 부스트 컨버터를 이용한 인버터 PCS 특성)

  • Hwang, Lark-Hoon;Na, Seung-kwon;Oh, Sang-hak
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.6
    • /
    • pp.654-664
    • /
    • 2018
  • In this paper, this system is operated by PCS that is driven by being synchronized voltage fed inverter and AC source, and in the steady state of power source charge battery connected to DC side with solar cell using a photovoltaic (PV) that it was so called constant voltage charge. it can cause the effect of energy saving of electric power, from 10 to 20%. and through a normal operation of electric energy storage system (EESS). In addition, better output waveform was generated because of pulse width modulation (PWM) method, and it was Proved to test by experiment maintained constant output voltage regardless of AC source disconnection, load variation, and voltage variation of AC power source.

An Experimental Study on the Fire Risk at Welding·Cutting Process (용접·절단 작업시 화재위험성에 관한 실험적 연구)

  • Lee, Sung-Ryong
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.60-66
    • /
    • 2012
  • In this study, it was evaluated the fire risk during welding cutting tasks. Welding-cutting machines are representatively used at construction sites. Inverter AC/DC TIG welding macnine and inverter air plasma cutting machine were used in experiments. Temperature of spreaded cinders was measured using a thermal camera. Cinder sizes and spread range were measured according to the height and input current. It was also evaluated the fire risk during welding-cutting process, when flammable materials were located around the working area. There were used hay, dust fence, urethane foam, vinyl, paper and oil as flammable materials. Temperature of spreaded cinders was reached at about $450^{\circ}C$. Cinders were spread approximately 4.7 m, when a worker carried out cutting process at 2.5 m height. The possibility of a fire is very high, when flammable materials were located around the working area.

Circuit Design of Parallel Power Operation Equipment for Peak Power Reduction (상전원의 피크치 전력 감소를 위한 전력병합장치 회로설계)

  • Yang, Jaesoo;Kim, Donghan;Kim, ManDo
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.3 no.9
    • /
    • pp.273-278
    • /
    • 2014
  • Recent use of electricity during peak hours electricity supply-demand imbalance is inevitable that limit power use force. Therefore, in this paper, a circuit of parallel power operation equipment for peak power reduction which saves the power to electricity storage device during the non-peak power time and supply from the storage power during the expected power shortages time is designed Through this circuitry, the peak power of the commercial power supply with the parallel operation and connection of the commercial power supply and the power supply of the inverter from electricity storage that is a key feature of PRS(Peak power Reduction System) can be controlled. In addition, in order to increase the efficiency, a Transless Power Circuit DC-AC inverter is developed. Moreover, a variable impedance control is applied to the storage of electric power of an Uninterruptible Power Supply associated with a commercial power source.

A novel anti-islanding method using Goertzel Algorithm (Goertzel 알고리즘을 이용한 새로운 단독운전 방지 기법)

  • Won, Dong-Jo;Kim, Jae-Hyung;Kim, Jun-Gu;Won, Chung-Yuen;Lee, Tae-Won
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.299-301
    • /
    • 2009
  • In this paper, a novel anti-islanding method of DC-AC single phase inverter is proposed. The inverter injects a little harmonic current with the output current of a PCS(Power Conditioning System). When the islanding condition is occurred, the voltage harmonic components appear on the output voltage of the PCS due to the injection of a little harmonic current. So, the PCS detects the voltage harmonic components using the Goertzel algorithm, and then the PCS decides that the islanding condition is occurred. When the PCS recognizes the islanding condition, the PCS are stopped. The proposed a novel anti-islanding method is analyzed, and its validity is proven through simulation.

  • PDF