• 제목/요약/키워드: D3-28S

검색결과 1,459건 처리시간 0.028초

Design and Fabrication of Dual Linear Polarization Antenna for mmWave Application using FR-4 Substrate

  • Choi, Tea-Il;Yoon, Joong-Han
    • Journal of the Korea Society of Computer and Information
    • /
    • 제27권3호
    • /
    • pp.71-77
    • /
    • 2022
  • In this paper, we propose 1×2 array antenna with dual linear polarization characteristics for mmWave band operation. The proposed antenna is designed two microstirp feeding structure and FR-4 substrate, which is thickness 0.4 mm, and the dielectric constant is 4.3. The size of 1×2 array antenna is 2.33 mm×2.33 mm, and total size of array antenna is 13.0 mm×6.90 mm. From the fabrication and measurement results, bandwidths of 1.13 GHz (28.52~29.65 GHz) for port 1 and 1.08 GHz (28.45~29.53 GHz) for port 2 were obtained based on the impedance bandwidth. Cross polarization ratios are obtained from 7.68 dBi to 16.90 dBi in case of vertical polarization, and from 7.46 dBi to 15.97 dBi in case of horizontal polarization for input port 1, respectively. Also, cross polarization ratios are obtained from 8.59 dBi to 13.72 dBi in case of vertical polarization and from 9.03 dB to 14.0 dB in case of horizontal polarization for input port 2, respectively.

A size-dependent quasi-3D model for wave dispersion analysis of FG nanoplates

  • Karami, Behrouz;Janghorban, Maziar;Shahsavari, Davood;Tounsi, Abdelouahed
    • Steel and Composite Structures
    • /
    • 제28권1호
    • /
    • pp.99-110
    • /
    • 2018
  • In this paper, a new size-dependent quasi-3D plate theory is presented for wave dispersion analysis of functionally graded nanoplates while resting on an elastic foundation and under the hygrothermaal environment. This quasi-3D plate theory considers both thickness stretching influences and shear deformation with the variations of displacements in the thickness direction as a parabolic function. Moreover, the stress-free boundary conditions on both sides of the plate are satisfied without using a shear correction factor. This theory includes five independent unknowns with results in only five governing equations. Size effects are obtained via a higher-order nonlocal strain gradient theory of elasticity. A variational approach is adopted to owning the governing equations employing Hamilton's principle. Solving analytically via Fourier series, these equations gives wave frequencies and phase velocities as a function of wave numbers. The validity of the present results is examined by comparing them with those of the known data in the literature. Parametric studies are conducted for material composition, size dependency, two parametric elastic foundation, temperature and moisture differences, and wave number. Some conclusions are drawn from the parametric studies with respect to the wave characteristics.

Design of Circularly Polarized Microstrip Patch Antenna Using Asymmetric Inset Feeding (비대칭 인셋 급전을 이용한 원형 편파 마이크로스트립 패치 안테나 설계)

  • Kwan-Joon Park;Dong-Kook Park
    • Journal of IKEEE
    • /
    • 제28권3호
    • /
    • pp.279-284
    • /
    • 2024
  • In this paper, we propose a novel method for implementing a microstrip patch antenna with circular polarization characteristics through an asymmetric inset feed structure. The proposed method involves designing an antenna by taking advantage of the length difference of the asymmetric inset slots inserted into the antenna, as well as the lengths of additional slots incorporated into the design to achieve circular polarization characteristics. Using this approach, we designed and fabricated an antenna operating at 2.4 GHz in the S-band for satellite communication systems, utilizing a 1 mm thick FR-4 dielectric substrate. The measurement results confirmed a gain of 2dBi, an axial ratio of less than 3dB, and a reflection coefficient below -10dB in the frequency range of 2.35 to 2.43 GHz. Based on these results, it is expected that by employing the proposed method, circularly polarized antennas utilizing inset feeds can be realised, thereby making them applicable in small satellite communication systems and various wireless IoT environmental service applications that use the ISM band.

Intake and Digestive Processes in the Rumen of Rams Fed with Digitaria decumbens Harvested at Four Stages of Grass Regrowth Age

  • Assoumaya, C.;Boval, M.;Sauvant, D.;Xande, A.;Poncet, C.;Archimede, H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제20권6호
    • /
    • pp.925-932
    • /
    • 2007
  • This study was designed to measure the effect of regrowth age of Digitaria decumbens (D. decumbens) on the intake and dynamics of digesta in the rumen of rams. Six Black-belly rams (mean liveweight: 51.6 (s.d. 0.68) kg) fitted with rumen cannulae were fed twice daily a 14-, 28-, 42- and 56-day old fresh D. decumbens successively for 4 experimental periods. The daily dry matter intake decreased curvilineary from 75.2 to 48.5 (s.e. 2.0) g/kg $BW^{0.75}$ as the age of the D. decumbens grass increased from 14 to 56 days. Dry matter intake for the first 3 h after the morning meal was 863.6, 598.3, 576.4 and 401.5 (s.e. 55.6) g for the 14-, 28-, 42- and 56-day old grasses respectively. The pool of NDF in the rumen at the end of the 3-h feeding period did not vary significantly among the four diets. Twelve hours after the beginning of the morning meal, the pool of NDF increased with the forage regrowth age. Within the total pool of NDF, the pool of large particles tended to increase with the regrowth age. It was concluded that high intake was associated with fast evacuation of NDF from the rumen. Moreover, digestion (cellulolysis) rate and degree of particle reduction by rumination are highly correlated, though speed of physical degradation of forage seems to be the driving force behind intake.

THERMAL-FLUID ANALYSIS FOR COOLING PERFORMANCE IMPROVEMENT OF 3.3KV(105A) COMPACT RACK TYPE MEDIUM VOLTAGE INVERTER SYSTEM (3.3kV(105A) COMPACT RACK TYPE 고압 인버터 시스템의 방열 성능 향상을 위한 열유동 해석)

  • Kim, S.Y.;Kim, S.D.;Ryoo, S.R.;You, N.K.;Kim, T.B.;Hong, C.O.;Ko, H.S.
    • Journal of computational fluids engineering
    • /
    • 제19권3호
    • /
    • pp.24-28
    • /
    • 2014
  • With ever rising concerns about saving of fossil fuel resource, there have been an increasing demand for use of energy more efficiently. The electric motor driven inverters can be a great help to improve energy efficiency. They are also used to control the motor speed to the actual need. Therefore the use of them can lead to reduce energy consumption. In particular, the medium voltage(MV) drive systems used for pumps, fans, steel rolling mills and tractions have widespread applications in the industry. They cover power ratings from 0.4MW to 40MW at the MV level of 2.3kV to 13.8kV. The majority of the installed MV drive systems however, are in the 1MW to 4MW range with voltage rating from 3.3kV to 6.6kV. But they are required to reduce size and weight like other power electronic equipments. In this paper, we studied on the 3.3kV(105A) compact rack type inverter system for improving the cooling efficiency. At first, we confirmed the tendency of temperature with computational simulation using ANSYS ICEPAK and actual experimental tests. And then we researched thermal performance improvement designs in order to reduce temperature of the transformer for the safe operation. It can reduce temperature of transformer that using pipe type flow guide in the system. As a result, we found out more efficient solution by thermal-fluid analysis.

Evaluation on Accuracy of Noise Measurement Applications for iPhone 4 and iPhone 3Gs (아이폰 4 및 아이폰 3Gs의 소음측정 애플리케이션에 대한 정확도 평가)

  • Ma, Hye Ran;Park, Doo Yong
    • Journal of the Korean Society of Safety
    • /
    • 제28권1호
    • /
    • pp.24-28
    • /
    • 2013
  • This article evaluates the accuracy of noise measurements for 37 noise measurement applications for iPhone 4 and iPhone 3Gs. Noise levels were measured using simultaneously a precision sound level meter and iPhones installed noise measurement applications at the levels of 70 dB, 80 dB and 90 dB at 1,000 Hz. Measurement errors were estimated by subtracting two measurements between iPhone and sound level meter. It was found that measurement errors of 34 applications(89.2%) were greater than ${\pm}2$ dB which is the maximum allowable error range for the Type II sound level meter. It was only 4 applications that measurement errors lie within ${\pm}2$ dB error range. There was no significant differences among measurements with four iPhone 4s. However, there were significant differences between the measurements with iPhone 4 and iPhone 3Gs using the same application. It was due to the different hardware specifications such as microphone. Therefore, noise measurement applications, for example, which has to utilize hardware of the smartphone, should be programmed to identify hardware specifications and to adopt appropriate correction factors upon hardware specifications. In conclusion, it is necessary to check accuracy and validity before using the noise measurement applications for iPhones. Also, it was suggested that it should develop an evaluation guideline or protocol on accuracy testing for the measurement applications using a smartphone.

Analysis the skin physical properties of periorbital region and cheek based on female's aging pattern by 7 years (한국 성인 여성의 눈가 피부 특성 분석)

  • Cho, Ga-Young;Kim, Jee-Yeun;Yeom, Myung-Hun;Cho, Jun-Cheol;Kim, Yoon-Bum
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • 제25권3호
    • /
    • pp.88-96
    • /
    • 2012
  • Objectives : We investigated the skin properties on the periorbital region and cheek of Korean female according to age pattern by 7year based on Sang Go Cheun Jin Ron (上古天眞論) in So Moon (素問,) Methods : 49 Korean females, aged 21-56 years ($39.54{\pm}10.04$ years) were participated in this study. We measured the skin properties of periorbital region and cheek with SkinTouch (Amorepacific, Korea). Skin moisture, sebum, elasticity, lightness, roughness, area of wrinkle, depth of wrinkle were assessed. Results : Differences were noticed depending on the site and age. The level of moisture was higher on the eyelid than crow's feet. The level of lightness and elasticity were lower on the periorbital region than cheek. Skin lightness was highest on group1(under 28y) and lowest on group5(over 49y). Skin roughness was highest on group1(under 28y) and lowest on group4(over 42y under 49y). The level of wrinkle are was lowest on group1(under 28y) and highest on group 5(over49y). The level of wrinkle depth was lowest on group1(under 28y) and highest on group 4(over 42y under 49y). Conclusion : Unique aging pattern by 7 years of female is reflected to diverse skin properties of eyes. It can be possible to apply the theory on Sang Go Cheun Jin Ron (上古天眞論) to practical use in dermatology and cosmetic.

Effects of Phytezyme Supplementation on the Growth Performance and Nutrient Digestibility in Growing Pigs

  • Hong, J.W.;Kim, I.H.;Kwon, O.S.;Lee, S.H.;Bae, H.D.;Kang, S.J.;Yang, U.M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제14권10호
    • /
    • pp.1440-1443
    • /
    • 2001
  • Forty eight $Duroc{\times}Yorkshire{\times}Landrace$ pigs ($15.2{\pm}0.3kg$ average initial BW) were used conducted to evaluate the effects dietary phytase (Phytezyme, WOOJIN, Co. Ltd) supplementation on the growth performance and nutrient digestibility in growing pigs. There were three pigs per pen and four pens per treatment. Treatments were 1) Con (corn-wheat-SBM), 2) PE0.1 (low-P iet+0.1% Phytezyme), 3) PE0.2 (Iow-P diet+0.2% Phytezyme), 4) PE0.3 (low-P diet+0.3% Phytezyme). During d 0 to 28, average daily gain was not significantly different among the treatments. Pigs fed PE0.3 diet significantly decreased (p<0.05) their average daily feed intake compared to pigs fed Con diet. Also, gain/feed in pigs fed PE0.1 and PE0.3 diet was improved (p<0.05) compared to pigs fed Con and PE0.2 diet (p<0.05). For d 28 to 56, pigs fed PE0.2 diet grew significantly faster (p<0.05) than pigs fed Con and PE0.1 diet. Gain/feed was greater (p<0.05) for PE0.2 and PE0.3 treatments than for Con. For overall period, average daily gain was increased (P<0.05) by the addition of 0.2% Phytezyme compared with Con. Gain/feed was significantly improved (p<0.05) by supplementation of PE0.3. Pigs fed PE0.2 showed increased DM and N digestibilities compared to pigs fed other treatments. Supplemented diets PE0.2 and PE0.3 improved (p<0.05) the apparent digestibility of Ca and P compared to other treatments. In conclusion, the results obtained from these feeding trials suggest that the Phytezyme supplementation of diets for growing-finishing pigs had improved growth performance and nutrient availability.

Technical Trends of Interposers for 2.5D Integration (2.5D 집적을 위한 인터포저 기술개발 동향)

  • Choi, K.S.;Bae, H.C.;Moon, S.H.;Eom, Y.S.
    • Electronics and Telecommunications Trends
    • /
    • 제27권1호
    • /
    • pp.51-60
    • /
    • 2012
  • 실리콘 관통 홀(TSV) 기술은 2006년 삼성전자가 낸드 플래시 메모리에 적용하여 적층된 시제품을 선보인 이후 선풍적인 기술적 관심을 불러일으키고 있다. 그러나, 안타깝게도 CMOS 이미지 센서 모듈 외에는 실제로 양산에 적용되고 있는 사례가 매우 드물다. 이는 기술적으로, 그리고 상업적으로도 극복해야 하는 어려움이 많기 때문이다. 최근 Xilinx사는 28nm FPGA를 네 개의 작은 칩으로 분리하여 TSV가 있는 실리콘 인터포저 위에 2차원적으로 집적한 제품을 고객사들에게 선적하기 시작했다. 이와 같은 2.5D 집적 기술은 3D IC 집적 기술의 상용화를 위한 중간 단계로 여겨질 뿐만 아니라 그 자체로 독립적인 시장을 형성할 기술로도 판단되고 있다. 본고에서는 2.5D 집적을 위한 인터포저 기술개발 및 표준화 동향에 대해 소개하고자 한다.

  • PDF

Quantitative Analysis of GBCA Reaction by Mol Concentration Change on MRI Sequence (MRI sequence에 따른 GBCA 몰농도별 반응에 대한 정량적 분석)

  • Jeong, Hyun Keun;Jeong, Hyun Do;Kim, Ho Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • 제52권2호
    • /
    • pp.182-192
    • /
    • 2015
  • In this paper, we introduce how to change the reaction rate as mol concentration when we scan enhanced MRI with GBCA(Gadolinium Based Contrast Agent), Also show the changing patterns depending on diverse MRI sequences which are made by different physical principle. For this study, we made MRI phantom ourselves. We mixed 500 mmol Gadoteridol with Saline in each 28 different containers from 500 to 0 mmol. After that, MR phantom was scanned by physically different MRI sequences which are T1 SE, T2 FLAIR, T1 FLAIR, 3D FLASH, T1 3D SPACE and 3D SPCIR in 1.5T bore. The results were as follows : *T1 Spin echo's Total SI(Signal Intensity) was 15608.7, Max peak was 1352.6 in 1 mmol. *T2 FLAIR's Total SI was 9106.4, Max peak was 0.4 1721.6 in 1 mmol. *T1 FLAIR's Total SI was 20972.5, Max peak was 1604.9 in 1 mmol. *3D FLASH's Total SI was 20924.0, Max peak was 1425.7 in 40 mmol. *3D SPACE 1mm's Total SI was 6399.0, Max peak was 528.3 in 3 mmol. *3D SPACE 5mm's Total SI was 6276.5, Max peak was 514.6 in 2 mmol. *3D SPCIR's Total SI was 1778.8, Max peak was 383.8 in 0.4 mmol. In most sequences, High signal intensity was shown in diluted lower concentration rather than high concentration, And also graph's max peak and pattern had difference value according to the each different sequence. Through this paper which have quantitative result of GBCA's reaction rate depending on sequence, We expect that practical enhanced MR protocol can be performed in clinical field.