• Title/Summary/Keyword: D. Coating

Search Result 849, Processing Time 0.027 seconds

Laser Damage Threshold Increase of A/R Coating Films for 200MHz AOM (A/R 코팅 변화에 따른 200MHz AOM의 laser damage threshold 증가)

  • Kim, Yong-Hun;Lee, Hang-Hun;Lee, Jin-Ho;Park, Yeong-Jun;Park, Jeong-Ho
    • Korean Journal of Materials Research
    • /
    • v.7 no.3
    • /
    • pp.213-217
    • /
    • 1997
  • AOhf(Hcousto-r)l)tic niodulator) with :!OOlIiz freclucncl- and Sfi(;(Seconrl harmonic generation) green lasel-Lvith 53% nm wavelength were used for Il\'IIII~Dii.it,ii v~ilco disk recorder) FOI rhe appli~aptin of high densit]. optical recording, a high po\ver I ~ c r is r c ~ ~ l i ~ i l - u l ic I !tic. s\-sti,m a n d optic.,~I io;iting l,t)c>rs of each optical device must have a high laser damage threshoid hie rn;itie ant] retlwtive coatings on a $TeO_{2}$ singlc crystal. which is used as an acoustooptic material, by E-beam evaporation method. Laser damage threshold \vas nicdsureci hy Ar laser with the input power oi 0.55LV 1,aser damage threiholti 01 $ZrO_{2}$ and $SiO_{2}$. filn-is were higher than $AI_{2}O_{3}$ f i l m U'e also investigated a long--tern1 stability of the output po\ver of St{(; green laser

  • PDF

Analysis of Multi-layered Thin Film Using ATR FT-IR and pyro-GC/MS (ATR FT-IR과 pyro-GC/MS를 이용한 다층박막필름의 분석)

  • Park, Sung Il;Lee, Jung-Hyun;Lee, Myung Cheon
    • Journal of Adhesion and Interface
    • /
    • v.20 no.3
    • /
    • pp.102-109
    • /
    • 2019
  • The material constitution of multi-layered thin film coated on the PET base film was analyzed using ATR FT-IR and pyro GC/MS combination. The cross section of the film was acquired by cracking the film after dipping in liquid nitrogen and was observed using optical microscope. Total thickness of the coated film was $70{\mu}m$ and three layers were observed. Since each layers were too thin to analyze directly except the surface layer, analyzable area of each layers were exposed by using a proper solvent and were investigated using ATR FT-IR and pyro GC/MS. Results shows that three layers were commonly consisted of urethane-acrylate copolymers. Also, inorganic and/or metal inclusions detected by XPS and SEM-EDAX were exhibited by nano size $SiO_2$ particles in layer(1) and aluminum flakes in layer(2).

Fabrication of 3D Multilayered Microfluidic Channel Using Fluorinated Ethylene Propylene Nanoparticle Dispersion (불소화 에틸렌 프로필렌 나노 입자 분산액을 이용한 3차원 다층 미세유체 채널 제작)

  • Min, Kyoung-Ik
    • Korean Chemical Engineering Research
    • /
    • v.59 no.4
    • /
    • pp.639-643
    • /
    • 2021
  • In this study, fluorinated ethylene propylene (FEP) nanoparticle as an adhesive for fabricating a three-dimensional multilayered microfluidic device was studied. The formation of evenly distributed FEP nanoparticles layer with 3 ㎛ in thickness on substrates was achieved by simple spin coating of FEP dispersion solution at 1500 rpm for 30 s. It is confirmed that FEP nanoparticles transformed into a hydrophobic thin film after thermal treatment at 300 ℃ for 1 hour, and fabricated polyimide film-based microfluidic device using FEP nanoparticle was endured pressure up to 2250 psi. Finally, a three-dimensional multilayered microfluidic device composed of 16 microreactors, which are difficult to fabricate with conventional photolithography, was successfully realized by simple one-step alignment of FEP coated nine polyimide films. The developed three-dimensional multilayered microfluidic device has the potential to be a powerful tool such as high-throughput screening, mass production, parallelization, and large-scale microfluidic integration for various applications in chemistry and biology.

A Study on the Removal Characteristics of a Radioactively Contaminated Oxide Film from the irradiated Stainless Steel Surface using Short Pulsed Laser Ablation (초단 펄스레이저 어블레이션에 의한 스테인리스강 표면의 오염산화막 제거 특성)

  • Kim, Geun-Woo;Yoon, Sung-Sik;Kim, Ki-Chul;Lee, Myung-Won;Kang, Myungchang
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.10
    • /
    • pp.105-110
    • /
    • 2020
  • Radioactive Oxides are formed on the surface of the primary equipment in a nuclear power plant. In order to remove the oxide film that is formed on the surfaces of the equipment, chemical and physical decontamination technologies are used. The disadvantage of traditional technologies is that they produce secondary radioactive wastes. Therefore, in this study, the short-pulsed laser eco-friendly technology was used in order to reduce production of the secondary radioactive wastes. They were also used to minimize the damages that were caused on the base material and to remove the contaminated oxide film. The study was carried out using a Stainless steel 304 specimen that was coated with nickel-ferrite particles. Further, the laser source was selected with two different wavelengths. Furthermore, the depth of the coating layer was analyzed using a 3D laser microscope by changing the laser ablation conditions. Based on the analysis, the optimal conditions of ablation were determined using a 1064nm short-pulsed laser ablation technique in order to remove the radioactively contaminated oxide film from the irradiated stainless steel surface.

Characterization of Solidification and Microstructure of an Al-Zn-Mg-Si Alloy

  • He Tian;Dongdong Qu;Zherui Tong;Nega Setargew;Daniel J. Parker;David StJohn;Kazuhiro Nogita
    • Corrosion Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.104-112
    • /
    • 2024
  • Al-Zn-Mg-Si alloy coatings have been developed to inhibit corrosion of cold rolled steel sheets, and an understanding of the alloy system helps prevent coating defects. We used a Bridgman furnace to characterise the nature and formation mechanisms of the phases present in the quaternary system with 0.4 wt% Fe. In the directional solidification experiments we imposed steep temperature gradients and varied the pull rate. After the samples were quenched in the furnace, detailed characterization of the samples was carried out by electron microscopy (SEM/EDS). From the dT/dt vs T plots of the cooling curves of the alloys, the solidification path was determined to be $Liquid{\longrightarrow[80]^{544-558}}{\alpha}-Al{\longrightarrow[80]^{453-459}}Al/Mg_2Si{\longrightarrow[80]^{371-374}}Al/Zn{\longrightarrow[80]^{331-333}}Zn/mgZn_2$. The formation mechanisms of the Mg and Zn containing phases and their morphology was discussed together with the effects of the cooling rate. Key findings include the lengthening of the mushy zone in directionally solidified samples remelted against a positive temperature gradient, as well as an enrichening of the α-Al phase by Zn through remelting. Mg2Si and other Si based phases were observed to adopt a much finer faceted microstructure in favour of a script-like microstructure when exposed to the higher cooling rate of coolant quenching.

An in vitro study of mesenchymal stem cell proliferation on titanium discs coated with rhTGF-β2/PLGA by electrospray (Electrospray법으로 rhTGF-β2/PLGA 복합체를 코팅한 티타늄에서의 간엽줄기세포 증식에 관한 연구)

  • Kim, Joohyung;Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Lee, Woo-Sung;Lee, Joo-Hee;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.2
    • /
    • pp.120-125
    • /
    • 2016
  • Purpose: The purpose of this study is to identify the effect of mesenchymal stem cell proliferation on recombinant human transforming growth factor-beta (rhTGF-${\beta}2$) / poly (D,L-lactide-co-glycolide) (PLGA) treated titanium discs by electrospray. Materials and methods: Anodized titanium surface coated with PLGA was used for a control group to compare anodized titanium surface coated with 125 ng/ml and 500 ng/ml rhTGF-${\beta}2$ as test groups. Atomic force microscope (AFM) test was utilized to determine the difference in coating surface roughness, and field-emission scanning electron microscopy (FE-SEM) was taken to visualize even distribution of coating particles on titanium discs. The mesenchymal stem cell proliferation was tested by using MTT (3-(4,5-dimethylthiazol-2-yl)-2,5 diphenyl-tetrazolium bromide) assay on 1st, 4th, 7th days. Results: According to AFM results, there was no statistically significant difference in titanium discs treated with PLGA and with rhTGF-${\beta}2$/PLGA (P>.05). MTT assay test results showed that there was statistically significant difference in mesenchymal stem cell proliferation on test groups compared to control groups at 7th day, and cell viability on discs coated with rhTGF-${\beta}2$ was significantly higher than control groups (P<.05). Conclusion: Titanium surface coated with rhTGF-${\beta}2$/PLGA shows statistically significant higher cell proliferation and the titanium surface coated with the higher concentration of rhTGF-${\beta}2$ presents faster cell growth activity.

Stellite bearings for liquid Zn-/Al-Systems with advanced chemical and physical properties by Mechanical Alloying and Standard-PM-Route

  • Zoz, H.;Benz, H.U.;Huettebraeucker, K.;Furken, L.;Ren, H.;Reichardt, R.
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2000.04a
    • /
    • pp.9-10
    • /
    • 2000
  • An important business-field of world-wide steel-industry is the coating of thin metal-sheets with zinc, zinc-aluminum and aluminum based materials. These products mostly go into automotive industry. in particular for the car-body. into building and construction industry as well as household appliances. Due to mass-production, the processing is done in large continuously operating plants where the mostly cold-rolled metal-strip as the substrate is handled in coils up to 40 tons unwind before and rolled up again after passing the processing plant which includes cleaning, annealing, hot-dip galvanizing / aluminizing and chemical treatment. In the liquid Zn, Zn-AI, AI-Zn and AI-Si bathes a combined action of corrosion and wear under high temperature and high stress onto the transfer components (rolls) accounts for major economic losses. Most critical here are the bearing systems of these rolls operating in the liquid system. Rolls in liquid system can not be avoided as they are needed to transfer the steel-strip into and out of the crucible. Since several years, ceramic roller bearings are tested here [1.2], however, in particular due to uncontrollable Slag-impurities within the hot bath [3], slide bearings are still expected to be of a higher potential [4]. The today's state of the art is the application of slide bearings based on Stellite\ulcorneragainst Stellite which is in general a 50-60 wt% Co-matrix with incorporated Cr- and W-carbides and other composites. Indeed Stellite is used as the bearing-material as of it's chemical properties (does not go into solution), the physical properties in particular with poor lubricating properties are not satisfying at all. To increase the Sliding behavior in the bearing system, about 0.15-0.2 wt% of lead has been added into the hot-bath in the past. Due to environmental regulations. this had to be reduced dramatically_ This together with the heavily increasing production rates expressed by increased velocity of the substrate-steel-band up to 200 m/min and increased tractate power up to 10 tons in modern plants. leads to life times of the bearings of a few up to several days only. To improve this situation. the Mechanical Alloying (MA) TeChnique [5.6.7.8] is used to prOduce advanced Stellite-based bearing materials. A lubricating phase is introduced into Stellite-powder-material by MA, the composite-powder-particles are coated by High Energy Milling (HEM) in order to produce bearing-bushes of approximately 12 kg by Sintering, Liquid Phase Sintering (LPS) and Hot Isostatic Pressing (HIP). The chemical and physical behavior of samples as well as the bearing systems in the hot galvanizing / aluminizing plant are discussed. DependenCies like lubricant material and composite, LPS-binder and composite, particle shape and PM-route with respect to achievable density. (temperature--) shock-reSistibility and corrosive-wear behavior will be described. The materials are characterized by particle size analysis (laser diffraction), scanning electron microscopy and X-ray diffraction. corrosive-wear behavior is determined using a special cylinder-in-bush apparatus (CIBA) as well as field-test in real production condition. Part I of this work describes the initial testing phase where different sample materials are produced, characterized, consolidated and tested in the CIBA under a common AI-Zn-system. The results are discussed and the material-system for the large components to be produced for the field test in real production condition is decided. Outlook: Part II of this work will describe the field test in a hot-dip-galvanizing/aluminizing plant of the mechanically alloyed bearing bushes under aluminum-rich liquid metal. Alter testing, the bushes will be characterized and obtained results with respect to wear. expected lifetime, surface roughness and infiltration will be discussed. Part III of this project will describe a second initial testing phase where the won results of part 1+11 will be transferred to the AI-Si system. Part IV of this project will describe the field test in a hot-dip-aluminizing plant of the mechanically alloyed bearing bushes under aluminum liquid metal. After testing. the bushes will be characterized and obtained results with respect to wear. expected lifetime, surface roughness and infiltration will be discussed.

  • PDF

Effect of Extracelluar Matrix on Cell-Surface Interactions and Growth of Cardiomyocyte(HL-1) (세포외 기질 물질에 따른 심근세포(HL-1)의 성장 연구)

  • Hong, Yoon-Mi;Anwar, Khalid;Kim, Sun-Min
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.1
    • /
    • pp.83-87
    • /
    • 2010
  • We present here the effect of extracellular matrix (ECM) on the proliferation and physiology of HL-1 cardiac cells. HL-1 cell is from AT-1 mouse atrial cardiomyocyte tumor lineage. HL-1 cell can be serially passaged, yet they maintain the ability to contract which is a promising character of HL-1 cell for the cell based biosensors. HL-1 cells grow up on the ECM which can affect on the attachment and growth of HL-1. In this paper, we discuss HL-1 cell-ECM interactions with three different ECMs and non-treated surface. HL-1 cells are grown for 4 days after seeding then observed their attachment. Also they were immunostained by hoechst and EthD-1 for proliferation, phalloidin for Factin, and DAPI for nuclei. Fibronectin was revealed as the proper ECM material for HL-1 cell culture. This study can provide basic information for understanding the cell-ECM interactions and growth of HL-1 cells.

Chromaticity(b*), Sheet Resistance and Transmittance of SiO2-ITO Thin Films Deposited on PET Film by Using Roll-to-Roll Sputter System (롤투롤시스템을 이용하여 PET 필름위에 제조된 SiO2-ITO 박막의 색도(b*), 면저항과 투과도 연구)

  • Park, Mi-Young;Kang, Bo-Gab;Kim, Jung-Soo;Kim, Hye-Young;Kim, Hu-Sik;Lim, Woo-Taik;Choi, Sik-Young
    • Korean Journal of Materials Research
    • /
    • v.21 no.5
    • /
    • pp.255-262
    • /
    • 2011
  • This paper has relatively high technical standard and experimental skill. The fabrication of TCO film with high transparency, low resistance and low chromaticity require exact control of several competing factors. This paper has resolved these problems reasonably well, thus recommended for publication. Indium tin oxide(ITO) thin films were by D.C. magnetron roll-to-roll sputter system utilizing ITO and $SiO_2$ targets of ITO and $SiO_2$. In this experiment, the effect of D.C. power, winding speed, and oxygen flow rate on electrical and optical properties of ITO thin films were investigated from the view point of sheet resistance, transmittance, and chromaticity($b^*$). The deposition of $SiO_2$ was performed with RF power of 400W, Ar gas of 50 sccm and the deposition of ITO, DC power of 600W, Ar gas of 50 sccm, $O^2$ gas of 0.2 sccm, and winding speed of 0.56m/min. High quality ITO thin films without $SiO_2$ layer had chromaticity of 2.87, sheet resistivity of 400 ohm/square, and transmittance of 88% and $SiO_2$-doped ITO Thin film with chromaticity of 2.01, sheet resistivity of 709 ohm/square, and transmittance of more than 90% were obtained. As a result, $SiO_2$ was coated on PET before deposition of ITO, their chromaticity($b^*$) and transmittance were better than previous results of ITO films. These results show that coating of $SiO_2$ induced arising chromaticity($b^*$) and transmittance. If the thickness of $SiO_2$ is controlled, sheet resistance value of ITO film will be expected to be better for touch screen. A four point probe and spectrophotometer are used to investigate the properties of ITO thin films.

Pharmacokinetic Evaluation and Gastric Ulcer Symptoms comparison of Ketorolac Tromethamine Sustained-Release Pellets after Oral Administration in Beagle Dogs (비글견을 이용한 케토롤락트로메타민 서방형 펠렛 제제의 위궤양 증상 비교와 약물속도론적 평가)

  • Yoon, Yang-No;Kim, Su-Ji;Jung, Suk-Hyun;Kim, Hyo-Jeong;Park, Eun-Seok;Hwang, Sung-Joo;Lee, Yong-Won;Seong, Ha-Soo;Shin, Byung-Cheol;Cho, Sun-Hang
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.6
    • /
    • pp.401-409
    • /
    • 2009
  • Ketrorolac tromethamine (KT), a nonsteroidal anti-inflammatory drug (NSAID) is required repeated administration due to its short blood half-life. To avoid dose-dependent side effects of KT, sustained-release pellets containing KT were prepared by coating with Eudragit$^{(R)}$ RS 100 and Eudragit$^{(R)}$ NE 30D. The in vitro and in vivo drug release behavior of KT from Eudragit$^{(R)}$ RS 100 and NE 30D coated pellet (SR-A), Eudragit$^{(R)}$ RS 100 coated pellet (SR-B) and conventional commercial immediate-release tablet (IR) was investigated. KT from SR-A and SR-B was slowly released over several hours, whereas IR showed rapid initial release in vitro. The pharmacokinetic study in vivo was performed by oral administration in beagle dogs. 5 mg IR was administered 3 times at intervals 5 hr. Five milligrams of IR was administered 3 times at intervals of 5 hr and 15 mg of SR-A and SR-B did once. After administering IR, KT concentration in blood showed high peak- trough fluctuation and stomach ulcer were discovered. On the other hand, SR-A and SR-B sustainedly released KT and reduced the occurrence of stomach ulcer. There sustained-release pellets will be effective system to minimize dosedependent of side effect and improve patient compliance.