PSS Modeling and Cerification for #6 Generator of Boryong T/P (보령 T/P 6호기 PSS 모델링과 검증)

  • Choi, H.K.;Kim, D.J.;Moon, Y.H.;Kim, Y.H.;Yoon, Y.B.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.31-34
    • /
    • 2002
  • It studied modelling about employing analog PSS in domestic 500MW grade standard thermoelectric power plant in this paper. Modeling and parameters were verified by simulation of PSS response characteristics measured in AVR step examination and using power plant system model parameters decided by generator characteristics test. Through this PSS modelling research, contributed in domestic electrical power system small signal stability as that do modelling to be possible exact analysis of power system.

  • PDF

Health prognostics of stator Windings in Water-Cooled Generator using Fick's second law (Fick's second law 를 이용한 수냉식 발전기 고정자 권선의 건전성 예지)

  • Youn, Byeng D.;Jang, Beom-Chan;Kim, Hee-Soo;Bae, Yong-Chae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.533-538
    • /
    • 2014
  • Power generator is one of the most important component of electricity generation system to convert mechanical energy to electrical energy. I t designed robustly to maintain high system reliability during operation time. But unexpected failure of the power generator could happen and it cause huge amount of economic and social loss. To keep it from unexpected failure, health prognostics should be carried out In this research, We developed a health prognostic method of stator windings in power generator with statistical data analysis and degradation modeling against water absorption. We divided whole 42 windings into two groups, absorption suspected group and normal group. We built a degradation model of absorption suspected winding using Fick's second law to predict upcoming absorption data. Through the analysis of data of normal group, we could figure out the distribution of data of normal windings. After that, we can properly predict absorption data of normal windings. With data prediction of two groups, we derived upcoming Directional Mahalanobis Distance (DMD) of absorption suspected winding and time vs DMD curve. Finally we drew the probability distribution of Remaining Useful Life of absorption suspected windings.

  • PDF

Pulse generator using series-connected boost converter (승압헝 컨버터의 직렬 배열에 의한 펄스전압 발생회로)

  • Baek, J.W.;Yoo, D.W.;Byun, Y.B.;Kim, T.J.;Cho, G.Y.;Kim, H.G.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1106-1109
    • /
    • 2002
  • This paper introduces an improved pulse generator using power semiconductors. The proposed circuit consists of the series connected boost converter structure. In the presented circuits, high voltage pulse is generated by series-connection of capacitors and IGBTs. The charging of capacitors and voltage balance of IGBTs is done automatically. To verify the proposed circuit, 1kV, 25A pulse generator is manufactured and tested.

  • PDF

Analysis of current characteristics of outage generator for microgrid in outage mode operation (마이크로그리드용 순간정전발생기의 순간정전모드 동작시 전류특성 해석)

  • Lee, Y.H.;Min, B.H.;Nho, E.C.;Kim, I.D.;Chun, T.W.;Kim, H.G.
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.130-132
    • /
    • 2008
  • This paper describes the current characteristics of outage generator for microgrid in outage mode operation. The outage can be generated with 3-phase voltage disturbance generator. The STS current becomes very huge during the first cycle of the outage, and the magnitude of the current depends on the time impedance, series transformer leakage inductance, interfacing reactor of PCS, and the maximum allowable PCS output current. The current and load voltage waveform are analysed through simulation.

  • PDF

Switching Characteristics Analysis of Bypass SCR for Series Transformer in 3-phase Voltage Disturbance Generator (3상 전압변동발생기의 직렬변압기 바이패스용 SCR의 스위칭 특성해석)

  • Song, W.H.;Park, H.Y.;Nho, E.C.;Kim, I.D.;Kim, H.G.;Chun, T.W.
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.71-72
    • /
    • 2010
  • This paper deals with the SCR thyristor switching characteristics of a 3-phase voltage disturbance generator. The series transformers of the generator require bypass SCR thyristors to provide the source voltage to the output terminal in normal operating mode. The SCR thyristor switching characteristics is quite different according to the connection point to the series transformer. The switching characteristics is analysed and verified through simulation results.

  • PDF

Switching Characteristics Analysis of Bypass SCR for Series Transformer in 3-phase Voltage Disturbance Generator (3상 전압변동발생기의 직렬변압기 바이패스용 SCR의 스위칭 특성해석)

  • Song, W.H.;Park, H.Y.;Nho, E.C.;Kim, I.D.;Kim, H.G.;Chun, T.W.
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.532-533
    • /
    • 2010
  • This paper deals with the SCR thyristor switching characteristics of a 3-phase voltage disturbance generator. The series transformers of the generator require bypass SCR thyristors to provide the source voltage to the output terminal in normal operating mode. The SCR thyristor switching characteristics is quite different according to the connection point to the series transformer. The switching characteristics is analysed and verified through simulation results.

  • PDF

Output Voltage Disturbance Analysis for 100kw-Rated Outage and Phase Jump Generator (100kW급 순간정전 및 위상급변 발생기의 출력 전압변동 해석)

  • Nho, E.C.;Park, H.Y.;Kim, J.Y.;Kim, I.D.;Chun, T.W.;Kim, H.G.
    • Proceedings of the KIEE Conference
    • /
    • 2008.10c
    • /
    • pp.123-125
    • /
    • 2008
  • This paper deals with output voltage characteristics analysis of outage and phase jump generator. As soon as the outage occurs the STS(Solid Transfer Switch)s are switched off. At the beginning of the outage the DG is required to limit the reverse current within the rated DG output current. In case of phase jump the DG output voltage phase should be adjusted with PLL. Simulation results show the output voltage characteristics of the generator.

  • PDF

A Study On the Controller of Synchronous Generator for Distributed Generation (분산전원용 동기발전기의 제어기 모델링에 대한 연구)

  • Kim, C.S.;Kim, T.E.;Kim, J.E.;Hwang, J.S.;Ryu, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.220-222
    • /
    • 2002
  • DG (Distributed Generation) devices such as co-generation systems, fuel cells and photovoltaic power generation systems, etc is introducing into the distribution systems by the deregulation. In this paper, the controller of synchronous generator used for DG is newly designed in order to regulate the real & reactive power and the effect on the islanding phenomenon compared with the traditional controller.

  • PDF

Neutron irradiation impact on structural and electrical properties of polycrystalline Al2O3

  • Sunil Kumar;Sejal Shah;S. Vala;M. Abhangi;A. Chakraborty
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.402-409
    • /
    • 2024
  • High energy neutron irradiations impact on structural and electrical properties of alumina are studied with particular emphasis on real time in-situ radiation induced conductivity measurement in low flux region. Polycrystalline Al2O3 samples are subjected to high energy neutrons produced from D-T neutron generator and Am-Be neutron source. 14 MeV neutrons from D-T generator are chosen to study the role of fast neutron irradiation in the structural modification of samples. Real time in-situ electrical measurement is performed to investigate the change in insulation resistance of Al2O3 due to radiation induced conductivity at low flux regime. During neutron irradiation, a significant transient decrease in insulation resistance is observed which recovers relative higher value just after neutron exposure is switched off. XRD results of 14 MeV neutron irradiated samples suggest annealing effect. Impact of relatively low energy neutrons on the structural properties is also studied using Am-Be neutrons. In this case, clustering is observed on the sample surface after prolonged neutron exposure. The structural characterizations of pristine and irradiated Al2O3 samples are performed using XRD, SEM, and EDX. The results from these characterizations are analysed and interpreted in the manuscript.