• Title/Summary/Keyword: D-H Parameter

Search Result 476, Processing Time 0.032 seconds

STOCHASTIC CHARACTERISTICS OF FATIGUE CRACK GROWTH RESISTANCE OF SM45C STEEL

  • Park, U.H.;Lee, H.W.;Kim, S.J.;Lee, C.R.;Kim, J.H.
    • International Journal of Automotive Technology
    • /
    • v.8 no.5
    • /
    • pp.623-628
    • /
    • 2007
  • Reliability analysis based on fracture mechanics requires knowledge of the on statistical parameters m and C in the fatigue crack growth law $da/dN=C({\Delta}K)^m$. The purpose of the present study is to investigate if it is possible to explain the change of parameter m by the fluctuation of C only. In this study, we apply the Paris-Erdogan law treating the parameter C as random and the parameter m as constant. Fluctuations in crack growth rate are assumed to be dependent only on C. The material resistance to fatigue crack growth(Z=1/C) is treated as a spatially random process, that varies along the crack path. The theoretical crack growth rates at various stress intensity factors are discussed. Additionally, the results of constant ${\Delta}K$ fatigue crack growth tests are reported for the structural steel, SM45C. The experimental data have been analyzed to determine the probability distribution of fatigue crack growth resistanc.

A study on the implementation of optical absorption spectrum analyzer for detecting gases in OF power cable (OF 케이블 Gas 검출을 위한 광흡수 스펙트럼 분석장치 구현에 관한 연구)

  • Oh, S.K.;Kang, D.S.;Kim, Y.H.;Kang, U.;Ryoo, H.S.;Park, H.S.;Roh, J.D.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2450-2452
    • /
    • 1999
  • Presently, it is now developing the optical remote gas sensor system which can measure combustible gases such as $CH_4$ and $C_2H_2$ generating by partial discharges inside the cable and connection parts to detect thermal deterioration of Oil-Filled (OF) power cable at the appropriate time. It is the most important parameter to select central wavelength of laser diode (LD) by analyzing the absorption bend of measuring gases in the infrared region. In this research, we proposed the optical spectrum analyzer to absorption band of $CH_4$ and $C_2H_2$ for the preliminary research of optical fiber gas detecting system.

  • PDF

A Study on the Pulse Wave Parameter in Non Delivery and Delivery Women (미출산 여성과 출산 여성의 맥파 비교 - 난임 맥파 지표 연구를 위한 -)

  • Seo, Chang-Woon;Kim, Gyeong-Cheol;Kim, Yi-Soon
    • Korean Journal of Acupuncture
    • /
    • v.29 no.2
    • /
    • pp.200-215
    • /
    • 2012
  • Objectives : The purpose of this study is to investigate the differences of pulse wave parameter between the non delivery group (single women with no childbirth experience) and the delivery group (married women who gave birth(s) in delivery). Methods : Sixty one healthy (non delivery) nulliparous women and fifty three delivery women participated in this study. We used 3 dimensional pulse analyser(3D MAC, DAEYOMEDI co., Korea), which measures radial pulse waveform non-invasively by way of tonometry method at 5 different applied pressure levels. From 114 subjects enrolled, pulse wave parameters were measured on the six locations of Chon, Kwan and Cheok of each hands. Results : Delivery group's pulse showed larger values in the following pulse wave parameters (Energy, Ap, RAI, As, Aw, h1, h2, h4, h4/h1, t, t1, t2, t4, Wm, Wm/t). Non delivery group's pulse indicated larger values in the pulse wave parameters such as Energy of left Chon, difference pulse energy between left and right hand, Ad, h5, h5/h1, t5. Conclusions : According to the analysis result, delivery group's pulse has bigger values in most part of pulse wave parameters, especially in Kwan and Cheok which correspond to Liver, Kidney, and Myeong-mun. We interpret these results that delivery women are more mature and stable in reproductive organs than non delivery group, as they have experienced delivery(deliveries) and child-caring through married life.

A Study on the Arc Characteristics of Axial Magnetic Field Type Electrode for Vacuum interrupter by Desing Parameters (설계변수에 따른 진공인터럽터용 종자계방식 전극의 아크특성에 관한 연구)

  • Kim, S.I.;Park, H.T.;Ahn, H.I.;Seo, J.M.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.672-674
    • /
    • 2001
  • Axial magnetic field(AMF) type electrode can increase the interrupting capability of vacuum interrupters. But, this interrupting capability vary with design parameters such as shape of electrode, slits of contact, material of contact and so on. In this paper, shown arc characteristics of unipolar axial magnetic field type electrode for vacuum interrupter by design parameters such as shape of contact slits and diameter of contact. And, confirmed vacuum arc configuration by individual design parameter using high speed camera.

  • PDF

The Photoinactivation of Photosystem II in Leaves: A Personal Perspective

  • Chow, Wah-Soon
    • Journal of Photoscience
    • /
    • v.8 no.2
    • /
    • pp.43-53
    • /
    • 2001
  • a, a parameter that describes how effectively photoinactivated PS II units protect their functional neighbours; car, carotenoids; ΔpH, transthylakoid pH difference; D1 protein, psbA gene product in the PS II reaction centre; f, functional fraction of PS II: F$\_$v//F$\_$m/, the ratio of variable to maximum chlorophyll a fluorescence; k$\_$d/, rate coefficient for degradation of D1 protein; k$\_$i/ and k$\_$r/, rate coefficient for photoinactivation and repair of PS II, respectively; NADP+, oxidized nicontinamide adenine dinucleotide phosphate; P680, the primary electron donor in the PSII reaction centre; Ph, pheophytin; PS, photosystem; Q$\_$A/, first quinone acceptor of an electron in PS II; R$\_$s/, the gross rate of D1 protein synthesis.

  • PDF

Solution Properties of ${\gamma}$-Polyglutamic Acid Produced by Alkalophilic Alcaligenes sp. (호 알칼리성 Alcaligenes sp.가 생산하는 ${\gamma}$-Polyglutamic Acid의 용액 특성)

  • 이신영;강태수김갑수
    • KSBB Journal
    • /
    • v.10 no.4
    • /
    • pp.386-392
    • /
    • 1995
  • The high viscous ${\gamma}$-polyglutamic acid(${\gamma}$-PGA) from alkalophilic Alcaligenes sp. was purified and its solution property was investigated. The intrinsic viscosities for Na+ form and H+ form of ${\gamma}$-PGA were 31.1 and 0.38d$\ell$/g, respectively. The viscosity of H+-PGA was not influenced by pH or salts while that of Na+-PGA was influenced. The intrinsic viscosity of Na+-PGA solution decreased remarkably at the alkaline or acidic pH and showed the sharp decrease when salts were added. ${\gamma}$-PGA exhibited the property of the polyelectrolyte showing the .sharp decrease of intrinsic viscosity by the addition of NaCl, and intrinsic viscosity of dilute solution with the low concentration of NaCl was exponentially dependent on temperature and its temperature dependency increased with increasing NaCl concentration. The chain stiffness, coil overlap parameter and critical concentration of Na+-PGA were 0.08, 5.25 and 0.07g/d$\ell$, respectively.

  • PDF

Soil arching analysis in embankments on soft clays reinforced by stone columns

  • Fattah, Mohammed Y.;Zabar, Bushra S.;Hassan, Hanan A.
    • Structural Engineering and Mechanics
    • /
    • v.56 no.4
    • /
    • pp.507-534
    • /
    • 2015
  • The present work investigates the behavior of the embankment models resting on soft soil reinforced with ordinary and stone columns encased with geogrid. Model tests were performed with different spacing distances between stone columns and two lengths to diameter ratios (L/d) of the stone columns, in addition to different embankment heights. A total number of 42 model tests were carried out on a soil with undrianed shear strength $${\sim_\sim}10kPa$$. The models consist of stone columns embankment at s/d equal to 2.5, 3 and 4 with L/d ratio equal 5 and 8. Three embankment heights; 200 mm, 250 mm and 300 mm were tested for both tests of ordinary (OSC) and geogrid encased stone columns (ESC). Three earth pressure cells were used to measure directly the vertical effective stress on column at the top of the middle stone column under the center line of embankment and on the edge stone column for all models while the third cell was placed at the base of embankment between two columns to measure the vertical effective stress in soft soil directly. The performance of stone columns embankments relies upon the ability of the granular embankment material to arch over the 'gaps' between the stone columns spacing. The results showed that the ratio of the embankment height to the clear spacing between columns (h/s-d) is a key parameter. It is found that (h/s-d)<1.2 and 1.4 for OSC and ESC, respectively; (h is the embankment height, s is the spacing between columns and d is the diameter of stone columns), no effect of arching is pronounced, the settlement at the surface of the embankment is very large, and the stress acting on the subsoil is virtually unmodified from the nominal overburden stress. When $(h/s-d){\geq}2.2$ for OSC and ESC respectively, full arching will occur and minimum stress on subsoil between stone columns will act, so the range of critical embankment height will be 1.2 (h/sd) to 2.2 (h/s-d) for both OSC and ESC models.

Macroblock Layer Bit-rates Control Algorithm based on the Linear Source Model (선형 모델 기반 매크로블록 레이어 비트율 제어 기법)

  • Seo Dong-Wan;Choe Yoonsik
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.6
    • /
    • pp.63-72
    • /
    • 2005
  • In this paper, we propose the bit-rate control algorithm for the block based image compression like H.263, H.263+ or MPEG-4. The proposed algorithm is designed to identify the quantization parameter set through the Lagrangian optimization technique based on the well-known linear source model. We set the Lagrangian cost function with the rates and distortion calculated from the linear source model. We calculate the quantization parameter set using the Vitervi algorithm to solve the Lagrangian optimization problem considering the Dquant method of H.263 and MPEG-4. The proposed algorithm improves the video quality by up to 1.5 dB compared with the TMN8 scheme, and is more effective in the video sources with dynamic activities than the consistent quality approaches.

Design of Robust and Non-fragile $H_{\infty}$ Kalman-type Filter for System with Parameter Uncertainties: PLMI Approach (변수 불확실성을 가지는 시스템에 대한 견실비약성 $H_{\infty}$ 칼만형필터 설계: PLMI 접근법)

  • Kim, Joon Ki;Yang, Seung Hyeop;Bang, Kyung Ho;Park, Hong Bae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.10
    • /
    • pp.181-186
    • /
    • 2012
  • In this paper, we describe the synthesis of robust and non-fragile Kalman filter design for a class of uncertain linear system with polytopic uncertainties and filter gain variations. The sufficient condition of filter existence, the design method of robust non-fragile filter, and the measure of non-fragility in filter are presented via LMIs(Linear Matrix Inequality) technique. And the obtained sufficient condition can be represented as PLMIs(parameterized linear matrix inequalities) that is, coefficients of LMIs are functions of a parameter confined to a compact set. Since PLMIs generate infinite LMIs, we use relaxation technique, find the finite solution for robust non-fragile filter, and show that the resulting filter guarantees the asymptotic stability with parameter uncertainties and filter fragility. Finally, a numerical example will be shown.