• Title/Summary/Keyword: D factor

Search Result 6,425, Processing Time 0.038 seconds

Selective Solvent Extraction of In from Synthesis Solution of MOCVD Dust using D2EHPA (MOCVD 더스트 합성용액으로부터 D2EHPA를 이용한 In의 선택적 용매추출)

  • Im, Byoungyong;Swain, Basudev;Lee, Chan Gi;Park, Jae Layng;Park, Kyung-Soo;Shim, Jong-Gil;Park, Jeung-Jin
    • Resources Recycling
    • /
    • v.24 no.5
    • /
    • pp.80-86
    • /
    • 2015
  • The separation of In from the synthesis solution with Ga, Fe, and Al has been studied by the solvent extraction using D2EHPA as an extractant. The effects as a function of the concentration of extractant and HCl on the extraction of In were investigated. The extraction of In and Ga increased with decreasing HCl concentration, but that of Fe and Al was independent. Separation factor between In and Ga of 115 was obtained at 1.0 M D2EHPA in the presence of 0.5 M HCl of feed solution. Consequently, this study shows that D2EHPA is suitable extractant for In extraction from the synthesis solution. Extraction efficiency and separation factor could be increased by controlling HCl and extractant concentration.

Sperm Cytosolic Factor Activation for Bovine Somatic Cell Nuclear Transfer

  • Shin, Tae-Young
    • Journal of Embryo Transfer
    • /
    • v.26 no.3
    • /
    • pp.171-180
    • /
    • 2011
  • In this study I report that in vitro development rates of bovine nuclear transfer embryos activated either with boar sperm cytosolic factor (SCF) or with ionomycin followed by cycloheximide (CHX) and subsequent in vivo developmental rates after embryo transfer are related to blastocyst quality as evaluated by apoptosis analysis. SCF was extracted from porcine semen then purified for post-activation injection after nuclear transfer. The optimal timing for SCF injection was determined to be at least 22 h post-IVM for parthenogenetic activation of bovine oocyies. A total of 364 oocytes were successfully enucleated and 268 (73.6%) fused and were injected with SCF. The survival rate of fused and injected embryos was 109/113 (96.5%) after 2 h. The cleavage rates of nuclear transfer embryos after 3 d of culture in the ionomycin/CHX treated group were significantly higher than those of the SCF-activated group (93.3% vs 81.7%, p<0.01, respectively). However, at 7 d and 9 d there was no significant difference between the total developmental rates to blastocyst for either treatment group. Total blastocyst cell numbers were also not significantly different between the two activation treatments (ionomycin/CHX: 149.5${\pm}$7.7 vs. SCF: 139.3${\pm}$4.4 cells). In contrast, the apoptotic levels in the SCF blastocysts were higher than those produced after the chemical treatment (28.2${\pm}$5.1% vs. 8.8${\pm}$0.6%, respectively). A total of 18 expanded or hatching blastocysts was transferred to nine synchronized recipients in each activation group; 5/9 (55.5%) and 2/9 (22.2%) were pregnant at 40 d in the ionomycin/CHX treatment and SCF activated group, respectively. However, only one went to term in the ionomycin/CHX treatment while none of the pregnancies from the SCF group were maintained by 90 d. In conclusion, these results suggest that SCF derived from different species is a limited activator to be used for activation after bovine nuclear transfer in lieu of a chemical activation protocol.

Classification of Elderly Men's Foot Side Type from 3D Scan Data (3차원 스캔 데이터에 의한 노년 남성의 발 측면유형 분류)

  • Kim, Nam-Soon;Do, Wol-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.38 no.4
    • /
    • pp.427-439
    • /
    • 2014
  • This study identifies the foot side shapes of elderly men by classifying foot types according to 3D foot shapes and analyzing individual characteristics. The subjects were 284 elderly men over 60 years of age who lived in Gwangju and did not have foot related diseases. They were measured with a scanner (Nexcan$^{(R)}$ of K&I Technology) to obtain three dimensional feet shapes. Anthropometric measuring items consisted of 28 items estimated on the right foot of each subject. 3D scan data were analyzed by various statistical methods such as factor analysis, ANOVA and cluster analysis using the statistical program SPSS 19.0. A total of 7 factors were extracted through a factor analysis and these factors represent 77.56% of total variance. The 8 factors were: inside height and side gradient, ankle thickness, size from foot center to ankle, lateral malleolus height, forefoot height, instep and heel height and gradient. A total of 3 clusters (as foot type) were categorized using 7 factor scores by cluster analysis. Type 1 was classified as high forefoot and low midfoot compared to the length. Type 2 was classified as low forefoot and high midfoot, and type 3 was classified as low forefoot and low midfoot.

A Study on Fatigue Crack Propagation Behavior with Pure-Ti Plate (순수 티타늄 판재의 피로균열 전파거동에 관한 연구)

  • 오세욱;김태형;김득진;임만배
    • Journal of Ocean Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.92-100
    • /
    • 1995
  • The effect of different anisotropy and stress ratio on fatigue crack propagation behavior was investigated under various stress ratio(R=-0.4, -0.2, 0.2, 0.2, 0.4) using pure titanium sheet used in aerospace, chemical and food industry. The rack closure behavior under constant load amplitude fatigue crack propagation test was examined. Fatigue crack propagation rate da/dN was estimated in terms of effective stress intensity factor range, $\Delta$K$_{eff}$, regardless of various stress ratio but was influenced by anisotropy. Also, it was found that the effect of anisotropy was considerably decreased but still not negligible when he da/dN was evaluated by a conventional parameter, $\Delta$$K_{eff}$/E and when the modified da/dN.$\sqrt{\varepsilon}_f$ was evaluated by $\Delta$$K_{eff}$/E. On the other hand, da/dN could be evaluated uniquely by effective new parameter, $\Delta$K$_{eff}$/$sigma_{ys}$, regardless of anisotropy, as int he following equation da/dN=C''[\frac{{\Delta}K_{eff}}{{\sigma}_{ys}}]^{n''}. And effective stress intensity factor range ratio, U was estimated by the following equation with respect to the ratio of reversed plastic zone size, $\Delta r_{p}$ to monotonic plastic zone size, $r_p$ regardless of stress ratio and anisotropy. U=-4.45$(\Delta r_{p}/r_{p})^{2}$+4.1$(\Delta r_{p}/r_{p})$+0.245_{p})$+0.245

  • PDF

A Study of Enemy Aptitude of Pistol Sound Source for Space Estimation (공간평가를 위한 피스톨음원의 적정성에 관한 연구)

  • Shon, Jang-Ryul;Kim, Jung-Joong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.3 s.96
    • /
    • pp.320-328
    • /
    • 2005
  • Last target of architectural acoustics is that people wish to convey voice effectively from the space adaptively in use purpose in building. But, how exactly through space sound (sound source) that wish to deliver from indoor can be passed method to do quantification and evaluate quantity of sound by method to serve indoor architectural acoustics estimation summer period and methods to estimate definition propose. This Study searches special quality of sound source about MLS signal that is occurred short-answer sound source (pistol sound source) and nondirectional speaker among indoor sound estimation method, and measure and analyzed reverberation time (RT60), definition (C80, D50) by regulation of each ISO 3382 in age place (classroom, hall, gymnasium). Analysis result and sound factor among could know that d of two sound sources converges in measurement error extent about reverberation time (RT60) of analysis incidental and sound factors and value shows change irregularly about sound factor of D50, C80, pistol sound source judged there is problem. Also, could know that problem is happened in deflection except reverberation time is in deflection analysis with wave that measure each in fixed distance in branch. Finally, when differ size of sound source and measure about change of sound pressure level in case measure sound pressure level giving difference about 10 dB, sound factor could know that there is no different effect.

Characteristics and Classification of Armscye Circumference using 3D Scan Data (3차원 인체형상자료를 이용한 겨드랑둘레선의 형태특성 및 유형)

  • Choi, Kueng-Mi;Park, Sun-Mi;Nam, Yun-Ja;Jun, Jung-Ill;Ryu, Young-Sil
    • Fashion & Textile Research Journal
    • /
    • v.12 no.1
    • /
    • pp.80-85
    • /
    • 2010
  • The purpose of this study was to examine the characteristics of armscye circumference which will be used to develop total contents for the apparel industry. The subjects of this study were 16- to 49-year-old women whose 3D body shape data were analyzed. 72 length and length-ratio measurements were taken to each subject' armscye circumference. The used analysis methods are descriptive statistics, principal component analysis, and cluster analysis. The results are follows; 1. Considering the Length of armscye circumference, the result of principal component analysis were extracted 3 factors and those factors comprised 95% of total variance. As the result of the cluster analysis of factor scores, subjects were classified into 4 cluster by their size characteristic. 2. Considering the length-ratio of armscye circumference, the result of principal component analysis were extracted 5 factors and those factors comprised 96.45% of total variance. As the result of the cluster analysis of factor scores, subjects were classified into 5 cluster by their shape characteristic. So that, this research could be useful to manufacture garment which reflected 3D body figure and improved fitting.

Optimization of High Efficiency Single Crystalline Silicon Solar Cell by Using PC1D (PC1D를 이용한 결정질 실리콘 태양전지 최적화)

  • Lee, Yong-Woo;Yi, Young-Seok;Han, Kyu-Min;Yi, Jun-Sin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.195-196
    • /
    • 2008
  • Doping depth, doping concentration, and resistivity of crystalline silicon solar cell are variables which take important portion in cell's efficiency. To get highly efficient solar cell, PC1D is used to calculate $I_{sc}$, $V_{oc}$, and $P_{max}$. Depth factor, peak doping, and base resistivity was used as variables. As a result, the optimized value of emitter peak doping is $1\times10^{19}cm^{-3}$, depth factor is $1{\mu}m$, and base $\rho$ is $ 0.1\Omega$-cm. Under the optimized condition, the solar cell gets efficiency 19.03(%).

  • PDF