• Title/Summary/Keyword: Cylindrical projection

Search Result 34, Processing Time 0.03 seconds

First Report of Clavinema mariae (Nematoda: Philometridae) in Cultured Rockfish, Sebastes schlegeli, in Cheonsuman (Bay), the Republic of Korea

  • Han, Hyun-Ja;Seo, Jung Soo;Park, Jeong Su;Lee, Haeng Lim;Seo, Han Gill;Jung, Sung Hee;Kwon, Se Ryun
    • Parasites, Hosts and Diseases
    • /
    • v.55 no.2
    • /
    • pp.219-224
    • /
    • 2017
  • In July 2012, philometrid nematodes were discovered in cultured rockfish (Sebastes schlegeli) in Cheonsuman (Bay), the Republic of Korea. The nematodes were detected in the epithelial tissues of the rockfish and were identified as Clavinema mariae based on morphological studies using light and scanning electron microscopy. They revealed the characteristics same as previously identified C. mariae, notably having a long body with narrow posterior half, no caudal projection, a cylindrical-shaped esophagus, a well-developed anterior bulbous part of the esophagus, cephalic papillae, and a dorsal esophageal gland. This is the first confirmation of C. mariae infection in rockfish in Korea.

The implementation of spherical acoustical holography (구형좌표계에서 음향 홀로그래피의 적용)

  • Kim, Yong-Joe;Cho, Yong-Thung;Bolton, J.Stuart
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.410-415
    • /
    • 2002
  • In this article, spatial filtering procedures with application to spherical acoustical holography are discussed. Planar and cylindrical holography are the most widely used amongst the various nearfield acoustical holography techniques. However, when the geometry of a source is similar to a sphere, spherical holography may yield better results than other types of holography since there are no errors due to truncation of the sound field in the spherical case. Spatial filtering affects the accuracy of spherical acoustical holography critically, especially in the case of backward projection. Thus spatial filtering is essential for successful application of spherical holography. In the present work, various filtering methods were evaluated in simulations made using sound pressure fields of various types and with different levels of random spatial noise. It was found that a procedure based on eliminating spherical harmonic coefficients that contribute insignificantly to the total sound power of the source gave the best results on average of the different procedures considered here. Spherical holography procedures were also verified experimentally. Reliable results were obtained using the power filtering algorithm. Thus it was concluded that spherical holography combined with power filtering may prove to be a useful tool for noise source identification.

  • PDF

Development of Full ice-cream cone model for HCME 3-D parameters

  • Na, Hyeonock;Moon, Yong-Jae;Lee, Harim
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.47.1-47.1
    • /
    • 2016
  • The determination of three dimensional parameters (e.g., radial speed, angular width, source location) of Coronal Mass Ejections (CMEs) is very important for space weather forecast. To estimate these parameters, several cone models based on a flat cone or a shallow ice-cream cone with spherical front have been suggested. In this study, we investigate which cone model is proper for halo CME morphology using 26 CMEs which are identified as halo CMEs by one spacecraft (SOHO or STEREO-A or B) and as limb CMEs by the other ones. From geometrical parameters of these CMEs such as their front curvature, we find that near full ice-cream cone CMEs are dominant over shallow ice-cream cone CMEs. Thus we develop a new full ice-cream cone model by assuming that a full ice-cream cone consists of many flat cones with different heights and angular widths. This model is carried out by the following steps: (1) construct a cone for given height and angular width, (2) project the cone onto the sky plane, (3) select points comprising the outer boundary, (4) minimize the difference between the estimated projection speeds with the observed ones. We apply this model to 12 SOHO halo CMEs and compare the results with those from other stereoscopic methods (a geometrical triangulation method and a Graduated Cylindrical Shell model) based on multi-spacecraft data.

  • PDF

Image-based Realistic Facial Expression Animation

  • Yang, Hyun-S.;Han, Tae-Woo;Lee, Ju-Ho
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 1999.06a
    • /
    • pp.133-140
    • /
    • 1999
  • In this paper, we propose a method of image-based three-dimensional modeling for realistic facial expression. In the proposed method, real human facial images are used to deform a generic three-dimensional mesh model and the deformed model is animated to generate facial expression animation. First, we take several pictures of the same person from several view angles. Then we project a three-dimensional face model onto the plane of each facial image and match the projected model with each image. The results are combined to generate a deformed three-dimensional model. We use the feature-based image metamorphosis to match the projected models with images. We then create a synthetic image from the two-dimensional images of a specific person's face. This synthetic image is texture-mapped to the cylindrical projection of the three-dimensional model. We also propose a muscle-based animation technique to generate realistic facial expression animations. This method facilitates the control of the animation. lastly, we show the animation results of the six represenative facial expressions.

Characterization of Deep Learning-Based and Hybrid Iterative Reconstruction for Image Quality Optimization at Computer Tomography Angiography (전산화단층촬영조영술에서 화질 최적화를 위한 딥러닝 기반 및 하이브리드 반복 재구성의 특성분석)

  • Pil-Hyun, Jeon;Chang-Lae, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2023
  • For optimal image quality of computer tomography angiography (CTA), different iodine concentrations and scan parameters were applied to quantitatively evaluate the image quality characteristics of filtered back projection (FBP), hybrid-iterative reconstruction (hybrid-IR), and deep learning reconstruction (DLR). A 320-row-detector CT scanner scanned a phantom with various iodine concentrations (1.2, 2.9, 4.9, 6.9, 10.4, 14.3, 18.4, and 25.9 mg/mL) located at the edge of a cylindrical water phantom with a diameter of 19 cm. Data obtained using each reconstruction technique was analyzed through noise, coefficient of variation (COV), and root mean square error (RMSE). As the iodine concentration increased, the CT number value increased, but the noise change did not show any special characteristics. COV decreased with increasing iodine concentration for FBP, adaptive iterative dose reduction (AIDR) 3D, and advanced intelligent clear-IQ engine (AiCE) at various tube voltages and tube currents. In addition, when the iodine concentration was low, there was a slight difference in COV between the reconstitution techniques, but there was little difference as the iodine concentration increased. AiCE showed the characteristic that RMSE decreased as the iodine concentration increased but rather increased after a specific concentration (4.9 mg/mL). Therefore, the user will have to consider the characteristics of scan parameters such as tube current and tube voltage as well as iodine concentration according to the reconstruction technique for optimal CTA image acquisition.

An Approach to 3D Object Localization Based on Monocular Vision

  • Jung, Sung-Hoon;Jang, Do-Won;Kim, Min-Hwan
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.12
    • /
    • pp.1658-1667
    • /
    • 2008
  • Reconstruction of 3D objects from a single view image is generally an ill-posed problem because of the projection distortion. A monocular vision based 3D object localization method is proposed in this paper, which approximates an object on the ground to a simple bounding solid and works automatically without any prior information about the object. A spherical or cylindrical object determined based on a circularity measure is approximated to a bounding cylinder, while the other general free-shaped objects to a bounding box or a bounding cylinder appropriately. For a general object, its silhouette on the ground is first computed by back-projecting its projected image in image plane onto the ground plane and then a base rectangle on the ground is determined by using the intuition that touched parts of the object on the ground should appear at lower part of the silhouette. The base rectangle is adjusted and extended until a derived bounding box from it can enclose the general object sufficiently. Height of the bounding box is also determined enough to enclose the general object. When the general object looks like a round-shaped object, a bounding cylinder that encloses the bounding box minimally is selected instead of the bounding box. A bounding solid can be utilized to localize a 3D object on the ground and to roughly estimate its volume. Usefulness of our approach is presented with experimental results on real image objects and limitations of our approach are discussed.

  • PDF

The effects of surface grinding and polishing on the phase transformation and flexural strength of zirconia

  • Lee, Ji-Young;Jang, Geun-Won;Park, In-Im;Heo, Yu-Ri;Son, Mee-Kyoung
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.1
    • /
    • pp.1-6
    • /
    • 2019
  • PURPOSE. The purpose of this in vitro study was to evaluate the effect of surface grinding and polishing procedures using high speed zirconia diamond burs with different grit sizes on the phase transformation and flexural strength of zirconia. MATERIALS AND METHODS. Forty disc shape specimens ($15{\times}1.25mm$) with a cylindrical projection in the center of each disc ($1{\times}3mm$) were fabricated with 3Y-TZP (Prettau, Zirkonzahn, Italy). The specimens were divided into 4 groups (n=10) according to the grinding and polishing procedures: Control group - grinding (coarse-grit diamond bur), Group 1 - grinding (coarse-grit diamond bur) + polishing, Group 2 - grinding (fine-grit diamond bur) + polishing, and Group 3 - grinding (fine grit diamond bur). Each specimen was analyzed by 3D-OM, XRD analysis, and biaxial flexural strength test. RESULTS. Based on the surface morphology by 3D-OM images, polished specimens showed smoother surface and lower roughness value (Ra). In the result of XRD analysis, partial phase transformation from tetragonal to monoclinic zirconia occurred in all groups. Control group, ground with a coarse grit diamond bur, showed more $t{\rightarrow}m$ phase transformation and lower flexural strength than Groups 1 and 2 significantly. CONCLUSION. The flexural strength in all specimens after grinding and polishing showed over 500 MPa, and those were clinically acceptable. However, grinding with a coarse grit diamond bur without polishing induced the phase transformation and low strength. Therefore, surface polishing is required for the occlusal adjustment using a high speed zirconia diamond bur to reduce the phase transformation and to prevent the decrease of flexural strength of zirconia.

Variation on Estimated Values of Radioactivity Concentration According to the Change of the Acquisition Time of SPECT/CT (SPECT/CT의 획득시간 증감에 따른 방사능농도 추정치의 변화)

  • Kim, Ji-Hyeon;Lee, Jooyoung;Son, Hyeon-Soo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.15-24
    • /
    • 2021
  • Purpose SPECT/CT was noted for its excellent correction method and qualitative functions based on fusion images in the early stages of dissemination, and interest in and utilization of quantitative functions has been increasing with the recent introduction of companion diagnostic therapy(Theranostics). Unlike PET/CT, various conditions like the type of collimator and detector rotation are a challenging factor for image acquisition and reconstruction methods at absolute quantification of SPECT/CT. Therefore, in this study, We want to find out the effect on the radioactivity concentration estimate by the increase or decrease of the total acquisition time according to the number of projections and the acquisition time per projection among SPECT/CT imaging conditions. Materials and Methods After filling the 9,293 ml cylindrical phantom with sterile water and diluting 99mTc 91.76 MBq, the standard image was taken with a total acquisition time of 600 sec (10 sec/frame × 120 frames, matrix size 128 × 128) and also volume sensitivity and the calibration factor was verified. Based on the standard image, the comparative images were obtained by increasing or decreasing the total acquisition time. namely 60 (-90%), 150 (-75%), 300 (-50%), 450 (-25%), 900 (+50%), and 1200 (+100%) sec. For each image detail, the acquisition time(sec/frame) per projection was set to 1.0, 2.5, 5.0, 7.5, 15.0 and 20.0 sec (fixed number of projections: 120 frame) and the number of projection images was set to 12, 30, 60, 90, 180 and 240 frames(fixed time per projection:10 sec). Based on the coefficients measured through the volume of interest in each acquired image, the percentage of variation about the contrast to noise ratio (CNR) was determined as a qualitative assessment, and the quantitative assessment was conducted through the percentage of variation of the radioactivity concentration estimate. At this time, the relationship between the radioactivity concentration estimate (cps/ml) and the actual radioactivity concentration (Bq/ml) was compared and analyzed using the recovery coefficient (RC_Recovery Coefficients) as an indicator. Results The results [CNR, radioactivity Concentration, RC] by the change in the number of projections for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.5%, +3.90%, 1.04] at -90%, [-77.9%, +2.71%, 1.03] at -75%, [-55.6%, +1.85%, 1.02] at -50%, [-33.6%, +1.37%, 1.01] at -25%, [-33.7%, +0.71%, 1.01] at +50%, [+93.2%, +0.32%, 1.00] at +100%. and also The results [CNR, radioactivity Concentration, RC] by the acquisition time change for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.3%, -3.55%, 0.96] at - 90%, [-73.4%, -0.17%, 1.00] at -75%, [-49.6%, -0.34%, 1.00] at -50%, [-24.9%, 0.03%, 1.00] at -25%, [+49.3%, -0.04%, 1.00] at +50%, [+99.0%, +0.11%, 1.00] at +100%. Conclusion In SPECT/CT, the total coefficient obtained according to the increase or decrease of the total acquisition time and the resulting image quality (CNR) showed a pattern that changed proportionally. On the other hand, quantitative evaluations through absolute quantification showed a change of less than 5% (-3.55 to +3.90%) under all experimental conditions, maintaining quantitative accuracy (RC 0.96 to 1.04). Considering the reduction of the total acquisition time rather than the increasing of the image acquiring time, The reduction in total acquisition time is applicable to quantitative analysis without significant loss and is judged to be clinically effective. This study shows that when increasing or decreasing of total acquisition time, changes in acquisition time per projection have fewer fluctuations that occur in qualitative and quantitative condition changes than the change in the number of projections under the same scanning time conditions.

DENS INVAGINATUS AND TALON CUSP CO-OCCURING: REPORT OF THREE CASES (치내치를 동반한 탈론 교두: 증례보고)

  • Im, Sung-Ok;Lee, Sang-Ho;Lee, Nan-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.4
    • /
    • pp.488-496
    • /
    • 2010
  • Dens evaginatus is a tooth with cylindrical enamel projection which forms a nodule on occlusal surface. It could be explained as outward overgrowth of inner enamel epithelium or localized hyperplasia of pulpal mesenchymal tissue during tooth development. A problem is that it is likely to be worn out or fractured by mastication ensuing pulpal inflammation. It is occasionally found on the lingual surface of upper anterior teeth as well, called talon cusp. Dens invaginatus is a tooth with deep lingual pit made by invagination of lingual enamel epithelium during tooth development while it is considered normal in terms of size and shape. Radiographically, a part of cervical enamel shows inward growth forming cavity and it is reasonable to say that the base is possibly open to pulpal cavity since they are very close. Talon cusp and dens invaginatus are relatively common abnormality of shape. However it becomes the opposite if the two exist in the same tooth. Once the talon cusp is broken by occlusal force or fissure between cusps is decayed, the complicated structure of canals makes the pulpal treatment difficult. Preventive treatments such as occlusal equilibrium and sealant, and regular oral examination should be preceded and thorough understanding of canal shape, using radiography, is required when pulpal treatment is necessary. This report is about a 9- year-old boy(lower left central incisor), a 8-year-old girl(upper right central incisor), and a 7-year-old boy(upper right central incisor), who have dens invaginatus and talon cusp in the same teeth. The first and the second patients are under pulpal treatments, and the last one is being observed showing no pathologic impressions.

Ultrastructural Variations on the Micropyle of Blacktip Grouper, Epinephelus Fasciatus before and after Artificial Fertilization (홍바리, Epinephelus fasciatus의 인공수정 전.후 난문의 미세구조적 변화)

  • Kim, Seong-Hoon;Lee, Chi-Hoon;Ju, Hea-Sung;Kim, Hyung-Bae;Lee, Young-Don
    • Applied Microscopy
    • /
    • v.41 no.2
    • /
    • pp.123-128
    • /
    • 2011
  • The micropyles on the prefertilized and artificial fertilized eggs of Epinephelus fasciatus were investigated using scanning electron microscope (SEM). The micropyles ($6.6{\pm}0.41\;{\mu}m$) of E. fasciatus eggs were found in the animal pole and theirs shape were observed as a flat crateriform of cylindrical shape. The micropylar vestibule arranged by 6~7 thickened spiral annuli on the ridge and contributed to differentiate and form fertilization cone for blocking to polyspermy by presenting swollen vestibule structure. As E. fasciatus eggs was pelagic, so chorionic surface was an uneven structures such as circular and fillar form nodules. Especially, various pores (0.15~0.55 ${\mu}m$, 230~270 pores) distributed at the only around micropyles, those pores radiately exhibited regular projection structures showing gill filament-shape. These ultrastructural characters of E. fasciatus eggs can be utilized in a taxonomical cue of grouper species.