• Title/Summary/Keyword: Cycling Operation

Search Result 62, Processing Time 0.025 seconds

Stability Tests on Anion Exchange Membrane Water Electrolyzer under On-Off Cycling with Continuous Solution Feeding

  • Niaz, Atif Khan;Lim, Hyung-Tae
    • Journal of Electrochemical Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.369-376
    • /
    • 2022
  • In this study, the stability of an anion exchange membrane water electrolyzer (AEMWE) cell was evaluated in an on-off cycling operation with respect to an applied electric bias, i.e., a current density of 500 mA cm-2, and an open circuit. The ohmic and polarization resistances of the system were monitored during operation (~800 h) using electrochemical impedance spectra. Specific consideration was given to the ohmic resistance of the cell, especially that of the membrane under on-off cycling conditions, by consistently feeding the cell with KOH solution. Owing to an excess feed solution, a momentary increase in the polarization resistance was observed immediately after the open-circuit. The excess feed solution was mostly recovered by subjecting the cell to the applied electric bias. Stability tests on the AEMWE cell under on-off cycling with continuous feeding even under an open circuit can guarantee long-term stability by avoiding an irreversible increase in ohmic and polarization resistances.

A Study on Fashion Design for Up-cycled Waste Resources (폐자원을 활용한 업사이클링 패션디자인 연구)

  • Park, Ju Hee;Kim, Youn Hee
    • Journal of the Korean Society of Costume
    • /
    • v.64 no.8
    • /
    • pp.138-154
    • /
    • 2014
  • The purpose of this study was to propose up-cycling fashion designs, based on guidelines derived from up-cycling fashion brand products and their required elements of the design. The study thus categorized required elements into environment, significance, economy, function, design, and material, then extracted a set of design guidelines. The guidelines for waste resource-based up-cycling fashion design include the followings: First, authenticity, taking mutual environmental relations into account. Second, rarity of products beyond the domain of standardized ready-made goods thanks to manual operation. Third, storytelling, reflecting the consumer history. Fourth, sustainability to signify the circulation of matters. Fifth, experimental characteristic to fulfill creative innovation. Sixth, changeability through interactions with wearers. The investigator decided design concepts based on them and created up-cycling design works with waste plastic bags, shirts, stockings, neckties, outdoor mats, and backpacks in a variety of formative expressive techniques.

Minimizing Empty Trips of Yard Trucks in Container Terminals by Dual Cycle Operations

  • Nguyen, Vu Duc;Kim, Kap-Hwan
    • Industrial Engineering and Management Systems
    • /
    • v.9 no.1
    • /
    • pp.28-40
    • /
    • 2010
  • One of the most important objectives of the schedules in a container terminal is to minimize the ship operation time, which consists of discharging and loading operation times. Recently, dual cycling techniques have been used for improving terminal operations, especially for reducing the total empty trips of handling equipment. The main focus of this study is to reduce the empty trip times of yard trucks with minimum delays for ship operations. A heuristic algorithm, modified from a previous algorithm, is proposed to solve this problem. A simulation study is conducted to evaluate the effect of different types of discharging and loading schedules and different locating methods for discharging containers in terms of the performance of the system, including the percentage of the dual cycle operations of yard trucks.

Development of Bib Pants Design and Pattern for Cycling Smart Wear (사이클링 스마트웨어 제작을 위한 빕 팬츠 디자인 및 패턴 개발)

  • Yunyoung, Kim;Byeongha, Ryu;Woojae, Lee;Kikwang, Lee;Rira, Kim
    • Journal of Fashion Business
    • /
    • v.26 no.5
    • /
    • pp.91-104
    • /
    • 2022
  • In this study, a cycling smart wear for measuring cycling posture and motion was developed using a three-dimensional motion analysis camera and an IMU inertial sensor. Results were compared according to parts to derive the optimal smart device attachment location, enabling correct posture measurement and cycle motion analysis to design a pattern. Conclusions were as follows: 1) 'S-T8' > 'S-T10' > 'S-L4' was the most significant area for each lumbar spine using a 3D motion analysis system with representative posture change (90°, 60°, 30°) to derive incisions and size specifications; 2) the part with the smallest relative angle change among significant section reference points during pattern design was applied as a reference point for attaching a cycling smart device to secure detachable safety of the device. Optimal locations for attaching the cycling device were the "S-L4" hip bone (Sacrum) and lumbar spine No. 4 (Lumbar 4th); 3) the most suitable sensor attachment location for monitoring knee induction-abduction was the anatomical location of the rectus femoris; 4) a cycling smart wear pattern was developed without incision in the part where the sensor and electrode passed. The wearing was confirmed with 3D CLO. This study aims to provide basic research on exercise analysis smart wear, to expand the smart cycling area that could only be realized with smart devices and smart watches attached to current cycles, and to provide an opportunity to commercialize it as cycling smart wear.

Effect of Ramping Rate on the Durability of Proton Exchange Membrane Water Electrolysis During Dynamic Operation Using Triangular Voltage Cycling

  • Hye Young Jung;Yong Seok Jun;Kwan-Young Lee;Hyun S. Park;Sung Ki Cho;Jong Hyun Jang
    • Journal of Electrochemical Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.253-260
    • /
    • 2024
  • Proton exchange membrane water electrolysis (PEMWE) is an efficient method for utilizing renewable energy sources such as wind and solar powers to produce green hydrogen. For PEMWE powered by renewable energy sources, its durability is a crucial factor in its performance since irregular and fluctuating characteristics of renewable energy sources, especially for wind power, can deteriorate the stability of PEMWE. Triangular voltage cycle is well able to simulate fluctuating wind power, but its effect on the durability has not been investigated extensively. In this study, the performance degradation of the PEMWE cell operated with the triangular voltage cycling was investigated at different ramping rates. The measured current responses during the cycling gradually decreased for both ramping rates, and I-V curve measurements before and after the cycling confirmed the degradation of the performances of PEMWE. For both measurements, the degradation rate was larger for 300 mV s-1 than 30 mV s-1, and they were determined as 0.36 and 1.26 mV h-1 (at the current density of 2 A cm-2) at the ramping rates of 30 and 300 mV s-1, respectively. The comparison with other studies on triangular voltage cycling also indicate that an increase in the ramping rate accelerates the deterioration of the PEMWE performance. X-ray photoelectron spectroscopy and transmission electron microscopy results showed that the Ir catalyst was oxidized and did not dissolve during the voltage cycling. This study suggests that the ramping rate of the triangular voltage cycling is an important factor for the evaluation of the durability of PEMWE cells.

Research of Circuit Working Construction Elevator with Single-guide Rail and Multi-cages

  • Kun Zhang;Kaiqiang Wang;Di Li;Qing Sun;Zhen Ye;Wei Liu
    • International Journal of High-Rise Buildings
    • /
    • v.11 no.2
    • /
    • pp.137-144
    • /
    • 2022
  • As one of the most important vertical transportation equipment in super high-rise buildings, the construction elevator directly affects the project period, cost, and effectiveness. The paper proposes a new construction elevator with single-guide rail and multi-cages. It can solve the problems of single construction elevator capacity shortage and efficacy decrease with height reduction, the occupancy of plan and elevation position of multiple construction elevators, and extension of total construction period by cycling operation of multi-cages on a single-guide rail. The paper focuses on the design and research of the main components of the equipment, such as the rotating guide rail mechanism, vertical bearing mast tie system, segmented electrical power supply system, group control scheduling system, and safety anti-collision system.

A Study on Performance Degradation of PEMFC by Repetitive Startup/Shutdown Cycling (시동/정지 반복에 따른 고분자전해질 연료전지의 성능 저하에 관한 연구)

  • Jo, Yoo-Yeon;Cho, Eun-Ae;Kim, Jung-Hyeun
    • Journal of Hydrogen and New Energy
    • /
    • v.20 no.4
    • /
    • pp.317-322
    • /
    • 2009
  • To investigate degradation mechanism of PEMFC operated with repetitive startup/shutdown cycling, i-V characteristics, impedance, cyclic voltamograms were measured. OCV decreased from 0.967 to 0.951 V while the cell voltage at 800mA/$cm^2$ from 0.657 to 0.563V, implying that the electrodes rather than membrane electrolyte was damaged during the cycling operation. Electrochemical analyses supported that the performance degradation could be mainly attributed to degradation of the electrodes such as a decrease in electrochemical active surface area rather than degradation of membrane.

A Case of Rapid Cycling Secondary Mania after Gamma-knife Radiosurgery (감마나이프 방사선수술 후 발생한 급속 순환성 이차성 조증 1예)

  • Chung, Chan-Ho;Chae, Jeong-Ho;Kim, Im-Ryol;Lee, Chung-Kyoon;Lee, Kyu-Hang
    • Korean Journal of Biological Psychiatry
    • /
    • v.3 no.2
    • /
    • pp.302-308
    • /
    • 1996
  • A case of rapid cycling mania secondary to gamma-knife radiosurgery for the treatment of refractory epilepsy was reported. A 21-year old woman who had a gamma-knife radiosurgical operation for the treatment of refractory seizure two years ago was admitted because of manic episodes. Although seizure was relieved, manic symptoms like decreased need for sleep, elated mood, unprovoked laughing, grandiose delusion and bizarre behaviors were developed 11 months after the operation. These symptoms recurred lour rimes for eight months. There were no past personal and family history of mood disorders. Laboratory examinations including electroencephalogram ana endocrinological study did not show any abnormal findings. The rapid cycling secondary manic was relieved by lithium. She was then discharged after 5 months. Mood change was not significant during follow-up while hypomania emerged by dose reduction. The secondary mania seemed to be caused or triggered by the right temporal lobe damage induced by gamma-knife radiosurgery.

  • PDF

Dual Cycle Plan for Efficient Ship Loading and Unloading in Container Terminals (컨테이너 터미널의 효율적인 선적 작업을 위한 Dual Cycle 계획)

  • Chung, Chang-Yun;Shin, Jae-Young
    • Journal of Navigation and Port Research
    • /
    • v.33 no.8
    • /
    • pp.555-562
    • /
    • 2009
  • At container terminals, a major measurement of productivity can be work-efficiency in quay-side. At the apron, containers are loaded onto the ship and unloaded to apron by Q/C(Quay Crane). For improving the productivity of quay crane, the more efficient Y/T(Yard Tractor) operation method is necessary in container terminals. Between quay-side and yard area, current transferring methods is single-cycling which doesn't start loading unless it finishes unloading. Dual-cycling is a technique that can be used to improve the productivity of quay-side and utility of yard tractor by ship loading and unloading simultaneously. Using the dual-cycling at terminals only necessitates an operational change without purchasing extra equipment. Exactly, Y/T operation method has to be changed the dedicate system to pooling system. This paper presents an efficient ship loading and unloading plan in container terminals, which use the dual-cycling. We propose genetic and tabu search algorithm for this problem.

The analysis of electrical characteristics with Micro-crack in PV module (Micro-cracks에 의한 PV 모듈의 전기적 특성 분석)

  • Song, Young-Hun;Ji, Yand-Geun;Kim, Kyung-Soo;Kang, Gi-Hwan;Yu, Gwon-Jong;Ahn, Hyung-Gun;Han, Deuk-Young
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.25-30
    • /
    • 2011
  • In this paper, we analyzed the electrical characteristics with Micro-cracks in Photovoltaic module. Micro cracks are increasing the breakage risk over the whole value chine from the wafer to the finished module, because the wafer or cell is exposed to mechanical stress. And The solar cells have to with stand the stress under out door operation in the finished module. Here the mechanical stress is induced by temperature changes and mechanical loads from wind and snow. So, we experimentally analyze the direct impact of micro-cracks on the module power and the consequences after artificial aging. The first step, we made micro-cracks in PV module by mechanical load test according to IEC 61215. Next, PV modules applied the thermal cycling test, because micro-cracks accelerated aging by thermal cycling test, according to IEC61215. Before every test, we checked output and EL image of PV module. As the result of first step, we detected little power loss(0.9%). But after thermal cycling test increased power loss about 3.2%.

  • PDF