• Title/Summary/Keyword: Cycle frequency

Search Result 1,045, Processing Time 0.029 seconds

Ovarian Morphology and Menstrual Cycle of Reproductive Age Women Receiving Anti-Epilepsy Medication (항경련제 투여를 받는 가임기 간질 여성의 난소의 형태 및 월경주기에 관한 연구)

  • Park, Seong-Ho;Ku, Seung Yup
    • Annals of Clinical Neurophysiology
    • /
    • v.4 no.1
    • /
    • pp.51-55
    • /
    • 2002
  • Background : An increased frequency of reproductive endocrine disorders and polycystic ovary(PCO) has been reported in women with epilepsy. A possible role of the seizure disorder or, of the use of antiepileptic drugs(AEDs) has been suggested as the pathogenic mechanism. The objective of the present study was to assess the prevalence of reproductive endocrine disorders, such as PCO or menstrual abnormalities, in a series of women with epilepsy, examining the possible relationships of these disturbances with different epilepsy syndromes and AED treatment. Methods : Thirty epileptic women, all of reproductive age and none pubertal, pregnant, or lactating, were evaluated by clinical endocrinological assessment, and pelvic ultrasonography. Seven patients were on valproic acid(VPA), nineteen on carbamazepine(CBZ), and four on diphenylhydantoin(DPH) treatment, respectively. Results : Menstrual irregularity was observed in 8 women(26.7%), dysmenorrhea in 7(23.3%), and premenstrual syndrome in 1(3.3%). Ultrasonographic examination revealed that one women(3.3%) showed polycystic ovary, 4(13.3%) had ovarian cyst(s), and 2(6.7%) had uterine myoma, respectively. There was no difference in the prevalence of menstrual abnormalities or polycystic ovary according to the different preparations of AEDs. Conclusions : Data from this investigation suggest that, in Korean reproductive age women, the treatment of AEDs and the kind of medication may not have a significant effect on the prevalence of menstrual abnormalities or ultrasonographic polycystic ovary.

  • PDF

Identification of Genetic Markers Distinguishing Golden Flounders from Normal Olive Flounders Paralichthys olivaceus Using Microsatellite Markers (황금색 넙치(Paralichthys olivaceus)의 발현을 예측할 수 있는 Microsatellite Marker 개발)

  • Kim, Min Sung;Kwak, Ju Ri;Kim, Tae Hwan;Han, Jae Yong;Park, Ji Been;Jo, Hyeon Kyeong;Suh, Jong-pyo;Lee, Woo-jai
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.53 no.4
    • /
    • pp.492-498
    • /
    • 2020
  • Despite its economic importance, olive flounder Paralichthys olivaceus aquaculture industry is facing a crisis with a continuous production decline. There have been many solutions to overcome the complicate predicament proposed. Increasing genetic diversity and discovering new commercial value through selective breeding are among them. The aims of the present study are to increase the selection power of the golden flounders. We examined the genetic diversity of the breeder population of golden flounders and developed selective markers for the golden flounder population. The 6 microsatellite (MS) markers were selected from melanogenesis-related genes, which are believed to be involved in the pigmentation of fish. All markers were polymorphic (except PO4) and 5 of them had PIC value of 0.6 or above. All makers had distinctive alleles indicating either normal or golden individuals. For examples, from PO4 marker, the frequency of an allele (316) in the golden population was 100% and in normal population was 0% (P<0.001). Although some more studies with more samples at the later generations should be performed to confirm this result, the 316 allele from PO4 marker could be a distinctive tool for decision of the colors in olive flounders at an early stage of the life cycle.

VLSI Design of an Improved Structure of a $GF(2^m)$ Divider (확장성에 유리한 병렬 알고리즘 방식에 기반한 $GF(2^m)$나눗셈기의 VLSI 설계)

  • Moon San-Gook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.3
    • /
    • pp.633-637
    • /
    • 2005
  • In this contribution, we developed and improved an existing GF (Galois field) dividing algorithm by suggesting a novel architecture for a finite field divider, which is frequently required for the error correction applications and the security-related applications such as the Reed-Solomon code, elliptic curve encryption/ decryption, is proposed. We utilized the VHDL language to verify the design methodology, and implemented the architecture on an FPGA chip. We suggested the n-bit lookup table method to obtain the throughput of 2m/n cycles, where m is the order of the division polynomial and n is the number of the most significant lookup-bits. By doing this, we extracted the advantages in achieving both high-throughput and less cost of the gate areaon the chip. A pilot FPGA chip was implemented with the case of m=4, n=2. We successfully utilized the Altera's EP20K30ETC144-1 to exhibit the maximum operating clock frequency of 77 MHz.

Boost $1\Psi$ converter of high efficiency by partial resonant switching using lossless snubber (무손실 스너버를 이용한 부분공진 스위칭에 의한 고효율 승압형 단상 컨버터)

  • 서기영;곽동걸;전중함;이현우
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.315-322
    • /
    • 1998
  • Power conversion system must increase switching frequency in order to achieve small size, light weight and low noise. However, the switches of converter are subject to high switching power losses and switching stresses. As a result, the power system has a lower efficiency. In this paper, the authors propose an AC-DC boost converter of high efficiency by partial resonant switching mode. The switching devices in the proposed circuit are operated with soft switching and the control technique of those is simplified for switch to drive in constant duty cycle. The partial resonant circuit makes use of a inductor using step up and a condenser of loss-less snubber. Besides, by regenerating energy, that is charged in a loss less snubber condenser of a snubber adopted to a common circuit, toward an input source part, this circuit can get increased efficiency. as merit. The result is that the switching loss is very low, the efficiency and power factor of system is high. The proposed converter is deemed the most suitable for high power applications where the power switching devices are used.

  • PDF

Comparison of Contrast Sensitivity Between Soft Contact Lens Wearers and Spectacle Wearers (콘택트렌즈와 안경 착용자의 대비감도 비교)

  • Kim, Jai-Min;Lee, Min-Ah
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.119-125
    • /
    • 2007
  • The aim of the present study was to compare the contrast sensitivity of soft contact lens wearers, spectacle wearers or emmetropia. Seventy myopic eyes and thirty emmetropic eyes aged 19 to 26 years were collected. The myopic group included 48 eyes corrected with spectacle lenses and 22 eyes of them corrected with contact lenses, too: all had corrected vision acuity of 20/20 or better. Spatial contrast sensitivity was measured using the OPTEC 6500 contrast sensitivity view-in tester included the EyeView  Functional Vision Analysis software at photopic or mesoopic condition. There was no significant difference in contrast sensitivity between spectacle lenses and emmetropes. Myopes corrected with soft contact lenses showed statistical sensitivity losses at 1.5, 12 cycle/degree spatial frequencies. In conclusion, our findings suggest that loss of contrast sensitivity in soft contact lens wearers might be interpreted as evidence for corneal disruption before corneal pathological events occur in contact lens wearers. Contrast sensitivity testing appears to be a useful method for evaluating soft contact lenses.

  • PDF

The Effects of Taping on Metacarpophalangeal Disorders of the Thumb (모지의 수근중수관절 손상에 대한 테이핑 효과)

  • Lee, Moon-Hwan;Kim, Eung-Chang;Lee, Soo-Yeon;Park, Rae-Joon
    • The Journal of Korean Physical Therapy
    • /
    • v.22 no.1
    • /
    • pp.33-38
    • /
    • 2010
  • Purpose: This study investigated the effect of taping therapy on metacarpophalangeal (MCP) disorders of the thumb. Methods: Twenty eight patients were enrolled in this study. They were randomly assigned to experimental (n=16) or a control group (n=12). The experimental and control groups received Ultrasound (Gymna Pulson 200) operating at a frequency of 3MHz and an intensity of $1.0W/cm^2$ with a 100% duty cycle for 10 minutes. The experimental group received, additionally, taping using Kinesiotape on the injured thumb. The following parameters were measured:pain during rest and flexion of the thumb, tenderness, range of motion (ROM), pinch and spherical grip power pre- and post-treatment. This study was carried out 3 days per week throughout the 2-week treatment. Results: There were significant improvements in pain during rest and flexion of the thumb, tenderness, ROM, pinch and spherical grip power between pre- and post-treatment times in both groups (p<0.05). However, there was a significant difference in all parameters between the experimental and control groups (p<0.05). Finally, the satisfaction level after intervention was significantly higher in the experimental group than in the control group (p<0.05). Conclusion: Taping is effective for treating pain and dysfunction in patients with thumb disorders.

Wear Characteristics for Rod and Nozzle of Jetting Dispenser Driven by Dual Piezoelectric Actuators Under High Frequency with Phosphor-containing Liquid (형광체 함유 용액 고속 토출 조건에서의 듀얼 압전 디스펜서 공이와 노즐의 마모 특성 평가)

  • Ha, Myeong-Woo;Lee, Kwang-Hee;An, Jun-Wook;Lee, Chul-Hee
    • Tribology and Lubricants
    • /
    • v.33 no.2
    • /
    • pp.52-58
    • /
    • 2017
  • An ultra-high precise ejection process is essential in a dispensing system for fabricating various precision parts such as a semiconductor, LED, and camera module. The size of such parts has been decreasing, which implies that a precise ejecting technique is required. A phosphor-containing liquid is ejected via a dispenser using dual piezoelectric actuators that are used for generating a high-speed dispensing mechanism. The rod and nozzle continuously contact in high speed to eject the liquid. However, the high-strength filler or phosphor in the liquid causes wear on the surfaces of the rod and nozzle during the dispensing process. As a result, the ejection reliability decreases as the wear on the surfaces increases. Therefore, it is necessary to estimate the wear characteristics of the rod and nozzle via an experiment and FE analysis. Reliability rests up to 1,000 cycles are conducted under relatively severe conditions. The flow rate and surfaces roughness of the rod and nozzle are measured in each ejection cycle. The surface images and wear volume are obtained before and after the tests and the ejection reliability is confirmed by measuring the flow rate of the liquid. The experimental results show that the ejection reliability is maintained up to 1,000k cycles; these results are validated by the simulation results.

The Development of Automatic Grease Lubricator Driven by Gear Mechanism with Controlled Operating Time (주유시간 조절이 가능한 기어 메커니즘 구동방식의 자동그리스주유기 개발)

  • Wang, Duck-Hyun;Lee, Kyu-Young;Lee, Sang-Hoon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.2 s.179
    • /
    • pp.199-206
    • /
    • 2006
  • Automatic grease lubricator is equipment that provides adequate amount of fresh grease constantly to the shaft and the bearings of machines. It minimizes the friction heat and reduces the friction loss of machines to the least. This research is to develop automatic grease lubricator by gear driven mechanism with controlled operation time. The ultimate design of this equipment is to lubricate an adequate amount of grease by a simple switch clicking according to the advanced set cycle. The backlash of the gear was minimized to increase the output power. To increase the power of gear mechanism, the binding frequency and the thickness of the coil were changed. To control the rotating cycles of the main shaft according to its set numbers, different resistance and chips were used to design the circuit to controls electrical signals with pulse. The body of the lubricator was analyzed by stress analysis with different constructed angle. The stress analysis for differing loading pressures applied to the exterior body of grease lubricator due to the setup angle, was found that the maximum stress was distributed over the outlet part where the grease lubricator suddenly narrowed contracts. Digital mock-up was analyzed and the rapid prototyping(RP) trial products were tested with PCB circuit and grease. The evaluation of the outlet capacity for RP trial products was conducted, because the friction caused by the outlet on the wall surface was an important factor in the operation of the equipment. Finally, the finishing process was applied to decrease the roughness of the surface to a comparable level and was able to test the performance examination for the product.

Web-Based Data Processing and Model Linkage Techniques for Agricultural Water-Resource Analysis (농촌유역 물순환 해석을 위한 웹기반 자료 전처리 및 모형 연계 기법 개발)

  • Park, Jihoon;Kang, Moon Seong;Song, Jung-Hun;Jun, Sang Min;Kim, Kyeung;Ryu, Jeong Hoon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.5
    • /
    • pp.101-111
    • /
    • 2015
  • Establishment of appropriate data in certain formats is essential for agricultural water cycle analysis, which involves complex interactions and uncertainties such as climate change, social & economic change, and watershed environmental change. The main objective of this study was to develop web-based Data processing and Model linkage Techniques for Agricultural Water-Resource analysis (AWR-DMT). The developed techniques consisted of database development, data processing technique, and model linkage technique. The watershed of this study was the upper Cheongmi stream and Geunsam-Ri. The database was constructed using MS SQL with data code, watershed characteristics, reservoir information, weather station information, meteorological data, processed data, hydrological data, and paddy field information. The AWR-DMT was developed using Python. Processing technique generated probable rainfall data using non-stationary frequency analysis and evapotranspiration data. Model linkage technique built input data for agricultural watershed models, such as the TANK and Agricultural Watershed Supply (AWS). This study might be considered to contribute to the development of intelligent watercycle analysis by developing data processing and model linkage techniques for agricultural water-resource analysis.

Characteristics of the Electro-Optical Camera(EOC)

  • Lee, Seung-Hoon;Shim, Hyung-Sik;Paik, Hong-Yul
    • Proceedings of the KSRS Conference
    • /
    • 1998.09a
    • /
    • pp.313-318
    • /
    • 1998
  • Electro-Optical Camera(EOC) is the main payload of Korea Multi-Purpose SATellite(KOMPSAT) with the mission of cartography to build up a digital map of Korean territory including Digital Terrain Elevation Map(DTEM). This instrument which comprises EOC Sensor Assembly and EOC Electronics Assembly produces the panchromatic images of 6.6 m GSD with a swath wider than 17 km by push-broom scanning and spacecraft body pointing in a visible range of wavelength, 510 ~ 730 nm. The high resolution panchromatic image is to be collected for 2 minutes during 98 minutes of orbit cycle covering about 800 km along ground track, over the mission lifetime of 3 years with the functions of programmable rain/offset and on-board image data storage. The image of 8 bit digitization, which is collected by a full reflective type F8.3 triplet without obscuration, is to be transmitted to Ground Station at a rate less than 25 Mbps. EOC was elaborated to have the performance which meets or surpasses its requirements of design phase. The spectral response the modulation transfer function, and the uniformity of all the 2592 pixel of CCD of EOC are illustrated as they were measured for the convenience of end-user. The spectral response was measured with respect to each gain setup of EOC and this is expected to give the capability of generating more accurate panchromatic image to the EOC data users. The modulation transfer function of EOC was measured as greater than 16% at Nyquist frequency over the entire field of view which exceeds its requirement of larger than 10%, The uniformity that shows the relative response of each pixel of CCD was measured at every pixel of the Focal Plane Array of EOC and is illustrated for the data processing.

  • PDF