• Title/Summary/Keyword: Cycle efficiency

Search Result 1,944, Processing Time 0.038 seconds

Effects of Manipulation Conditions on Development of Nuclear Transplant Bovine Embryos Derived from In Vitro Matured Oocytes (미세조작조건이 소 핵이식배의 발달에 미치는 영향)

  • 최상용;노규진;공일근;송상현;조성근;박준규;이효종;박충생
    • Korean Journal of Animal Reproduction
    • /
    • v.21 no.3
    • /
    • pp.293-302
    • /
    • 1997
  • Follicular oocytes of Grade I and II were collected from 2~6 mm ovarian follicles and matured in vitro (IVM) for 24 hrs in TCM-199 su, pp.emented with 35$\mu\textrm{g}$/ml FSH, 10$\mu\textrm{g}$/ml LH, and 1$\mu\textrm{g}$/ml estradiol-17$\beta$ at 39$^{\circ}C$ under 5% CO2 in air. They were fretilized in vitro (IVF) by epididymal spermatozoa capacitated with heparin for 12 hrs. The zygotes were then co-cultured in vitro with bovine oviducted epithelial cells (BOEC) for 7 to 9 days. The optimal time for IVM, the successful enucleation of IVM oocytes by micromanipulation at different oocyte ages after IVM, and the ideal culture system for IVM for effective IVF and in vitro development of IVM-IVF embryos was examined for in vitro production of nuclear recipient oocytes and nuclear donor embryos. To improve the efficiency of nuclear transplantation (NT) of IVF embryo into IVM follicular oocytes, this study evaluated the optimal electric condition and oocytes age for activation of IVM oocytes and in vitro development of NT embryos. In vitro development of NT embryos with preactivation or non-preactivation in enucleation oocytes, cell number of IVN-IVF embryos, and NT embryos wre also examined. The results obtained were as follows; 1. The most suitable enucleation time was at 24 hpm (83.3%) rather than that of 28 hpm(69.6%) and 32 hpm(50.0%). 2. There was no difference among the fusion rates of NT embryos at the voltages of 0.75, 1.0 and 1.5 kV/cm, but the in vitro development rates to morule and blastocyst were significantly (P<0.05) higher at the voltage of 0.75(12.5%) and 1.0kV/cm (12.6%) compared to 1.5kV/cm(0%). 3. No significant difference in activation rates were seen in NT embryos stimulated for 30, 60 and 120 $\mu$sec (71.7, 85.2 and 71.9%, respectively), but the in vitro development rates to morulae and blastocyst were significantly (P<0.05) higher in the oocytes stimulated for 30 $\mu$sec (11.6%) and 60 $\mu$sec(10.7%) than 120 $\mu$sec(0.0%). 4. The fusion rates (71.0 and 87.3%) and the in vitro development rates (9.1 and 12.7%) to morula and blastocyst were seen in the NT embryos stimulated at 28 and 32 hpm under the condition of 1.0 kV/ml, 60 $\mu$sec. However, at 24 hpm the fusion rates were 64.8% and the in vitro development to morula and blastocyst were not seen. 5. The fusion rates between the 8~12, 13~17 and 18~22-cell stage of IVM-IVF embryos were not significantly different. The in vitro development rates of the fused embryos to morula and blastocyst which were received from a blastomere of 8~12, 13~17 and 18~22-cell stages of IVM-IVF embryos were 14.9, 8.3 and 6.5%, respectively. 6. The in vitro development rate of the enucleated recipient oocytes with preactivation (24.2%) to morula and blastocyst was significantly (P<0.05) higher than that of non-preactivation (12.8%). 7. The cell numbers of NT blastocyst and IVM-IVF blastocyst cultured during 7~9 days were 63$\pm$11 and 119$\pm$23, and then their the mean cell cycle number were 5.98 and 6.89, respectively.

  • PDF

Efficiency Test for Surface Protecting Agents for the Chemical Resistance of Concrete Structures Using Sulfur Polymers (Sulfur Polymer를 사용한 콘크리트 구조물용 내화학성 표면보호재의 성능 평가)

  • Lee, Byung-Jae;Lee, Eue-Sung;Chung, Woo-Jung;Kim, Yun-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.5
    • /
    • pp.1-8
    • /
    • 2014
  • Structures requiring chemical resistance are usually coated with surface protecting agents, but the cost for maintenance and re-construction is incurred due to the low durability. Therefore, in this study, sulfur was polymerized and the performance was examined so that it could be used as the concrete surface protecting agents for structures requiring chemical resistance. The evaluation results indicated that for the spray of the sulfur polymer surface coating agents, the application of the gravity type was appropriate; and for the number of coating times, about 3 cycle spray gave the best results. For the surface condition of the concrete to be coated with the surface protecting agents, outstanding quality was obtained above room temperature ($20{\sim}30^{\circ}C$), and the bond strength increased as the temperature increased. The evaluation results of the strength characteristics depending on the filler content of the surface protecting agents indicated that about 20~40% filler mixing contributed to the strength improvement as it reduced the shrinkage of the sulfur polymer. Also, the mixing of silica showed larger increase in the bond strength than the mixing of fly ash, and the most outstanding bond strength characteristics could be obtained by the mixing of both silica and fly ash. In the case of the chemical resistance, the strength reduction was minimized and outstanding chemical resistance was obtained when the fly ash and silica were substituted by 20%, respectively. The performance evaluation of the chloride ion penetration indicated that for the specimens coated with the sulfur polymer surface protecting agents, the chloride ion penetration resistance increased by 29~48% compared to the specimen without the coating of the surface protecting agent. The examination of the coating condition of the surface protecting agents, compressive strength, bond strength, chemical resistance, and salt damage resistance indicated that in the range of this study, the optimal level was when the silica and fly ash were substituted by 20%, respectively, as the filler for the sulfur polymer.

Performance and Economic Analysis of Domestic Supercritical Coal-Fired Power Plant with Post-Combustion CO2 Capture Process (국내 초임계 석탄화력발전소에 연소 후 CO2 포집공정 설치 시 성능 및 경제성 평가)

  • Lee, Ji-Hyun;Kwak, No-Sang;Lee, In-Young;Jang, Kyung-Ryoung;Shim, Jae-Goo
    • Korean Chemical Engineering Research
    • /
    • v.50 no.2
    • /
    • pp.365-370
    • /
    • 2012
  • In this study, Economic analysis of supercritical coal-fired power plant with $CO_2$ capture process was performed. For this purpose, chemical absorption method using amine solvent, which is commercially available and most suitable for existing thermal power plant, was studied. For the evaluation of the economic analysis of coal-fired power plant with post-combustion $CO_2$ capture process in Korea, energy penalty after $CO_2$ capture was calculated using the power equivalent factor suggested by Bolland et al. And the overnight cost of power plant (or cost of plant construction) and the operation cost reported by the IEA (International Energy Agency) were used. Based on chemical absorption method using a amine solvent and 3.31 GJ/$tonCO_2$ as a regeneration energy in the stripper, the net power efficiency was reduced from 41.0% (without $CO_2$ capture) to 31.6% (with $CO_2$ capture) and the levelized cost of electricity was increased from 45.5 USD/MWh (Reference case, without $CO_2$ capture) to 73.9 USD/MWh (With $CO_2$ capture) and the cost of $CO_2$ avoided was estimated as 41.3 USD/$tonCO_2$.

A Study for the Methodology of Analyzing the Operation Behavior of Thermal Energy Grids with Connecting Operation (열 에너지 그리드 연계운전의 운전 거동 특성 분석을 위한 방법론에 관한 연구)

  • Im, Yong Hoon;Lee, Jae Yong;Chung, Mo
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.1 no.3
    • /
    • pp.143-150
    • /
    • 2012
  • A simulation methodology and corresponding program based on it is to be discussed for analyzing the effects of the networking operation of existing DHC system in connection with CHP system on-site. The practical simulation for arbitrary areas with various building compositions is carried out for the analysis of operational features in both systems, and the various aspects of thermal energy grids with connecting operation are highlighted through the detailed assessment of predicted results. The intrinsic operational features of CHP prime movers, gas engine, gas turbine etc., are effectively implemented by realizing the performance data, i.e. actual operation efficiency in the full and part loads range. For the sake of simplicity, a simple mathematical correlation model is proposed for simulating various aspects of change effectively on the existing DHC system side due to the connecting operation, instead of performing cycle simulations separately. The empirical correlations are developed using the hourly based annual operation data for a branch of the Korean District Heating Corporation (KDHC) and are implicit in relation between main operation parameters such as fuel consumption by use, heat and power production. In the simulation, a variety of system configurations are able to be considered according to any combination of the probable CHP prime-movers, absorption or turbo type cooling chillers of every kind and capacity. From the analysis of the thermal network operation simulations, it is found that the newly proposed methodology of mathematical correlation for modelling of the existing DHC system functions effectively in reflecting the operational variations due to thermal energy grids with connecting operation. The effects of intrinsic features of CHP prime-movers, e.g. the different ratio of heat and power production, various combinations of different types of chillers (i.e. absorption and turbo types) on the overall system operation are discussed in detail with the consideration of operation schemes and corresponding simulation algorithms.

A study of SCM strategic plan: Focusing on the case of LG electronics (공급사슬 관리 구축전략에 관한 연구: LG전자 사례 중심으로)

  • Lee, Gi-Wan;Lee, Sang-Youn
    • Journal of Distribution Science
    • /
    • v.9 no.3
    • /
    • pp.83-94
    • /
    • 2011
  • Most domestic companies, with the exclusion of major firms, are reluctant to implement a supply chain management (SCM) network into their operations. Most small- and medium-sized enterprises are not even aware of SCM. Due to the inherent total-systems efficiency of SCM, it coordinates domestic manufacturers, subcontractors, distributors, and physical distributors and cuts down on cost of inventory control, as well as demand management. Furthermore, a lack of SCM causes a decrease in competitiveness for domestic companies. The reason lies in the fundamentality of SCM, which is the characteristic of information sharing, process innovation throughout SCM, and the vast range of problems the SCM management tool is able to address. This study suggests the contemplation and reformation of the current SCM situation by analyzing the SCM strategic plan, discourses and logical discussions on the topic, and a successful case for adapting SCM; hence, the study plans to productively "process" SCM. First, it is necessary to contemplate the theoretical background of SCM before discussing how to successfully process SCM. I will describe the concept and background of SCM in Chapter 2, with a definition of SCM, types of SCM promotional activities, fields of SCM, necessity of applying SCM, and the effects of SCM. All of the defects in currently processing SCM will be introduced in Chapter 3. Discussion items include the following: the Bullwhip Effect; the breakdown in supply chain and sales networks due to e-business; the issue that even though the key to a successful SCM is cooperation between the production and distribution company, during the process of SCM, the companies, many times, put their profits first, resulting in a possible defect in demands estimation. Furthermore, the problems of processing SCM in a domestic distribution-production company concern Information Technology; for example, the new system introduced to the company is not compatible with the pre-existing document architecture. Second, for effective management, distribution and production companies should cooperate and enhance their partnership in the aspect of the corporation; however, in reality, this seldom occurs. Third, in the aspect of the work process, introducing SCM could provoke corporations during the integration of the distribution-production process. Fourth, to increase the achievement of the SCM strategy process, they need to set up a cross-functional team; however, many times, business partners lack the cooperation and business-information sharing tools necessary to effect the transition to SCM. Chapter 4 will address an SCM strategic plan and a case study of LG Electronics. The purpose of the strategic plan, strategic plans for types of business, adopting SCM in a distribution company, and the global supply chain process of LG Electronics will be introduced. The conclusion of the study is located in Chapter 5, which addresses the issue of the fierce competition that companies currently face in the global market environment and their increased investment in SCM, in order to better cope with short product life cycle and high customer expectations. The SCM management system has evolved through the adaptation of improved information, communication, and transportation technologies; now, it demands the utilization of various strategic resources. The introduction of SCM provides benefits to the management of a network of interconnected businesses by securing customer loyalty with cost and time savings, derived through the consolidation of many distribution systems; additionally, SCM helps enterprises form a wide range of marketing strategies. Thus, we could conclude that not only the distributors but all types of businesses should adopt the systems approach to supply chain strategies. SCM deals with the basic stream of distribution and increases the value of a company by replacing physical distribution with information. By the company obtaining and sharing ready information, it is able to create customer satisfaction at the end point of delivery to the consumer.

  • PDF

Optimal Operation of Gas Engine for Biogas Plant in Sewage Treatment Plant (하수처리장 바이오가스 플랜트의 가스엔진 최적 운영 방안)

  • Kim, Gill Jung;Kim, Lae Hyun
    • Journal of Energy Engineering
    • /
    • v.28 no.2
    • /
    • pp.18-35
    • /
    • 2019
  • The Korea District Heating Corporation operates a gas engine generator with a capacity of $4500m^3 /day$ of biogas generated from the sewage treatment plant of the Nanji Water Recycling Center and 1,500 kW. However, the actual operation experience of the biogas power plant is insufficient, and due to lack of accumulated technology and know-how, frequent breakdown and stoppage of the gas engine causes a lot of economic loss. Therefore, it is necessary to prepare technical fundamental measures for stable operation of the power plant In this study, a series of process problems of the gas engine plant using the biogas generated in the sewage treatment plant of the Nanji Water Recovery Center were identified and the optimization of the actual operation was made by minimizing the problems in each step. In order to purify the gas, which is the main cause of the failure stop, the conditions for establishing the quality standard of the adsorption capacity of the activated carbon were established through the analysis of the components and the adsorption test for the active carbon being used at present. In addition, the system was applied to actual operation by applying standards for replacement cycle of activated carbon to minimize impurities, strengthening measurement period of hydrogen sulfide, localization of activated carbon, and strengthening and improving the operation standards of the plant. As a result, the operating performance of gas engine # 1 was increased by 530% and the operation of the second engine was increased by 250%. In addition, improvement of vent line equipment has reduced work process and increased normal operation time and operation rate. In terms of economic efficiency, it also showed a sales increase of KRW 77,000 / year. By applying the strengthening and improvement measures of operating standards, it is possible to reduce the stoppage of the biogas plant, increase the utilization rate, It is judged to be an operational plan.

Changes in microbial phase by period after hepa filter replacement in King oyster(Pleurotus eryngii) mushroom cultivation (큰느타리 재배사에서 헤파필터 교체 이후 기간에 따른 미생물상 변화)

  • Park, Hye-Sung;Min, Gyong-Jin;Lee, Eun-Ji;Lee, Chan-Jung
    • Journal of Mushroom
    • /
    • v.18 no.4
    • /
    • pp.398-402
    • /
    • 2020
  • This study was conducted to set up a proper replacement cycle of High Efficiency Particulate Air (HEPA) filters by observing the microbial populations in the air of the cultivation house of Pleurotus eryngii, before and after HEPA filter replacement at different periods. The density of bacteria and fungi in the air during each cultivation stage was measured using a sampler before the replacement of the HEPA filter. The results showed that airborne microorganisms had the highest density in the mushroom medium preparation room, with 169.7 CFU/㎥ of bacteria and 570 CFU/㎥ of fungi, and the removed old spaun had 126.3 CFU/㎥ of bacteria and 560 CFU/㎥ of fungi. The density of bacteria and fungi in the air at each cultivation stage before the replacement of the HEPA filter was 169.7 CFU/㎥ and 570 CFU/㎥, and 126.3 CFU/㎥ and 560 CFU/㎥, during the medium production and harvesting processes, respectively. After the replacement of the HEPA filter, the bacterial density was the lowest in the incubation room and the fungal density was the lowest in the cooling room. The microbial populations isolated at each period consisted of seven genera and seven species before the replacement, including Cladosporium sp., six genera and six species after 1 month of replacement, including Penicillium sp., 5 genera and 7 species after 3 months of replacement, including Mucor plumbeus, and 5 genera and 12 species, 5 genera and 10 species, and 5 genera and 10 species, 4, 5, and 6 months after the replacement, respectively, including Penicillium brevicompactum. During the period after replacement, the species were diversified and their number increased. The density of airborne microorganisms decreased drastically after the replacement of the HEPA filter. Its lowest value was recorded after 2 months of replacement, and it increased gradually afterwards, reaching a level similar to or higher than that of the pre-replacement period. Therefore, it was concluded that replacing the HEPA filter every 6 months is effective for reducing contamination.

Analysis of Soil Changes in Vegetable LID Facilities (식생형 LID 시설의 내부 토양 변화 분석)

  • Lee, Seungjae;Yoon, Yeo-jin
    • Journal of Wetlands Research
    • /
    • v.24 no.3
    • /
    • pp.204-212
    • /
    • 2022
  • The LID technique began to be applied in Korea after 2009, and LID facilities are installed and operated for rainwater management in business districts such as the Ministry of Environment, the Ministry of Land, Infrastructure and Transport, and LH Corporation, public institutions, commercial land, housing, parks, and schools. However, looking at domestic cases, the application cases and operation periods are insufficient compared to those outside the country, so appropriate design standards and measures for operation and maintenance are insufficient. In particular, LID facilities constructed using LID techniques need to maintain the environment inside LID facilities because hydrological and environmental effects are expressed by material circulation and energy flow. The LID facility is designed with the treatment capacity planned for the water circulation target, and the proper maintenance, vegetation, and soil conditions are periodically identified, and the efficiency is maintained as much as possible. In other words, the soil created in LID is a very important design element because LID facilities are expected to have effects such as water pollution reduction, flood reduction, water resource acquisition, and temperature reduction while increasing water storage and penetration capacity through water circulation construction. In order to maintain and manage the functions of LID facilities accurately, the current state of the facilities and the cycle of replacement and maintenance should be accurately known through various quantitative data such as soil contamination, snow removal effects, and vegetation criteria. This study was conducted to investigate the current status of LID facilities installed in Korea from 2009 to 2020, and analyze soil changes through the continuity and current status of LID facilities applied over the past 10 years after collecting soil samples from the soil layer. Through analysis of Saturn, organic matter, hardness, water contents, pH, electrical conductivity, and salt, some vegetation-type LID facilities more than 5 to 7 years after construction showed results corresponding to the lower grade of landscape design. Facilities below the lower level can be recognized as a point of time when maintenance is necessary in a state that may cause problems in soil permeability and vegetation growth. Accordingly, it was found that LID facilities should be managed through soil replacement and replacement.

Method of Reducing Separation Membrane Fouling Using Microbubbles (마이크로버블을 이용한 분리막 파울링 저감방법)

  • Kyung-Hwan Ku;Younghee Kim
    • Clean Technology
    • /
    • v.29 no.1
    • /
    • pp.31-38
    • /
    • 2023
  • Due to water shortages caused by water pollution and climate change, total organic carbon (TOC) standards have been implemented for wastewater discharged from public sewage treatment facilities. Furthermore, there is a growing interest and body of research pertaining to the reuse of sewage treatment water as a secure alternative water resource. The membrane bio-reactor (MBR) method is commonly used for advanced wastewater treatment because it can remove organic and inorganic ions and it does not require or emit any chemicals. However, the MBR process uses a separation membrane (MF), which requires frequent film cleaning due to fouling caused by a high concentration of mixed liquor suspended solid (MLSS). In this study, process improvement and microbubble cleaning efficiency were evaluated to improve the differential pressure, water flow, and MF fouling, which are the biggest disadvantages of operating the MF. The existing MBR method was improved by installing a precipitation tank between the air tank and the MBR tank in which raw water was introduced. Microbubbles were injected into a separation membrane tank into which the supernatant water from the precipitation tank was introduced. The microbubble generator was operated with a 15 day on, 15 day off cycle for 5 months to collect discharged water samples (4L) and measure TOC. As the supernatant water from the precipitation tank flowed into the separation membrane tank, about 95% of the supernatant water MLSS was removed so the MF fouling from biological contamination was prevented. Due to the application of microbubbles to supernatant water from the precipitation tank, the differential pressure of the separation membrane tank decreased by 1.6 to 2.3 times and the water flow increased by 1.4 times. Applying microbubbles increased the TOC removal rate by more than 58%. This study showed that separately operating the air tank and the separation membrane tank can reduce fouling, and suggested that applying additional microbubbles could improve the differential pressure, water flow, and fouling to provide a more efficient advanced treatment method.

A Study on Image Copyright Archive Model for Museums (미술관 이미지저작권 아카이브 모델 연구)

  • Nam, Hyun Woo;Jeong, Seong In
    • Korea Science and Art Forum
    • /
    • v.23
    • /
    • pp.111-122
    • /
    • 2016
  • The purpose of this multi-disciplinary convergent study is to establish Image Copyright Archive Model for Museums to protect image copyright and vitalize the use of images out of necessity of research and development on copyright services over the life cycle of art contents created by the museums and out of the necessity to vitalize distribution market of image copyright contents in creative industry and to formulate management system of copyright services. This study made various suggestions for enhancement of transparency and efficiency of art contents ecosystem through vitalization of use and recycling of image copyright materials by proposing standard system for calculation, distribution, settlement and monitoring of copyright royalty of 1,000 domestic museums, galleries and exhibit halls. First, this study proposed contents and structure design of image copyright archive model and, by proposing art contents distribution service platform for prototype simulation, execution simulation and model operation simulation, established art contents copyright royalty process model. As billing system and technological development for image contents are still in incipient stage, this study used the existing contents billing framework as basic model for the development of billing technology for distribution of museum collections and artworks and automatic division and calculation engine for copyright royalty. Ultimately, study suggested image copyright archive model which can be used by artists, curators and distributors. In business strategy, study suggested niche market penetration of museum image copyright archive model. In sales expansion strategy, study established a business model in which effective process of image transaction can be conducted in the form of B2B, B2G, B2C and C2B through flexible connection of museum archive system and controllable management of image copyright materials can be possible. This study is expected to minimize disputes between copyright holder of artwork images and their owners and enhance manageability of copyrighted artworks through prevention of such disputes and provision of information on distribution and utilization of art contents (of collections and new creations) owned by the museums. In addition, by providing a guideline for archives of collections of museums and new creations, this study is expected to increase registration of image copyright and to make various convergent businesses possible such as billing, division and settlement of copyright royalty for image copyright distribution service.