Comparison of quality of 30:2 vs. 2:30 CPR in manikins (심폐소생술 방법 변화에 따른 quality 비교 - 30:2와 2:30 비교분석실험 -)

  • Uhm, Tai-Hwan;Yoou, Soon-Kyu;Choi, Hea-Kyung;Jung, Ji-Yeon
    • The Korean Journal of Emergency Medical Services
    • /
    • v.14 no.3
    • /
    • pp.71-81
    • /
    • 2010
  • Purpose: To minimize an interruption in chest compression, reduce the hands-off time, the American Heart Association has recommended the ratio of chest compression to ventilation ratio to 30:2 from 2005 CPR guideline to 2010 CPR guideline. However, current studies have shown that the hands-off time was > 10 seconds with that method. For this reason, we devised new CPR method that a ventilation to chest compression ratio of 2:30 to reduce pt assessment time and skipped the assessment step of carotid artery pulse would be a more effective way to reduce the hands-off time & the time to set the CPR. According to the more detailed purpose are listed below. 1) We would like to confirm efficiency of a ventilation to chest compression ratio of 2:30 than a chest compression to ventilation ratio of 30:2 to reduce the hands-off time & the time to set the CPR. 2) We would like to evaluate possibility of increasing for chest compression accuracy of a ventilation to chest compression ratio of 2:30 than a chest compression to ventilation ratio of 30:2 3) We would like to evaluate possibility of increasing for ventilation accuracy of a ventilation to chest compression ratio of 2:30 than a chest compression to ventilation ratio of 30:2 Methods: According to 2005 American Heart Association Guidelines, 60 paramedic students(20 students X freshmen, sophomore, junior) performed 5 cycles of 3~ chest compressions : 2 ventilations after A, B, C evaluation with Laerdal Resusci R Anne SkillReporters. After 5 minutes rest, the 60 students performed 5 cycles of 2 ventilations : 30 chest compressions after A, B evaluation with the manikins between 13 and 17 September 2010. The short reports including speed & accuracy of chest compression, respiratory, CPR cycle were gained from the manikins. Hands-off times were measured by assistants. Results: Recently, the importance of high quality CPR was emphasized in order to perform the CPR faster and more accurate. To find out improving the conventional CPR method, we switch the procedure of the compression and the ventilation. By switching the procedure back and forth, we are able to compare the effectiveness of CPR between two type of CPR method which are 2:30 and 30:2 methods. 2:30 is that the breaths is delivered twice, first and perform 30 compressions while 30:2 perform 30 compressions first and give 2 breaths followed by the ABC method. Also, we verify the effectiveness of the hands off time, compression accuracy of the compression through the comparison of the two procedure as mentioned earlier. Consequently research verified that 2:30 is the efficient by providing faster set up delivering more accurate chest compression. Conclusion: 2:30 can minimize a time delay from cardiac standstill until starting the chest compression. In addition, hands-off time which is an interruption in chest compression can be shortened by 2:30 method, which result to effective oxygenation of coronary artery & maintenance of the bloodstream. Once again, performing the 2:30 method provide lessen hands off time and increase the accuracy of the chest compression.

  • PDF

Determination of 129I in simulated radioactive wastes using distillation technique (증류법을 이용한 모의 방사성폐기물 중 129I 의 정량)

  • Choi, Ke-Chon;Song, Byung-Cheol;Han, Sun-Ho;Park, Yong-Joon;Song, Kyu-Seok
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.9 no.3
    • /
    • pp.141-148
    • /
    • 2011
  • It is clarified in the radioactive waste transfer regulation that the concentration of radioactive waste for the major radio nuclide has to be examined when radioactive waste is guided to the radioactive waste stores. In case of the low level radioactive waste sample, the analytical results of radioactive waste concentration frequently show a value lower than minimum detectable activity (MDA). Since the MDA value basically depends on the amount of a sample, background value, measurement time, counting efficiency, and etc, it would be necessary to increase a sample amount with a intention of minimizing MDA. In order to measure a concentration of $^{129}I$ in low and medium level radioactive waste, $^{129}I$ was collected by using a distillation technique after leaching the simulated radioactive waste sample with a non-volatile acid. The recovery of $^{129}I$ measured was compared with that measured with column elution technique which is a conventional method using an anion-exchange resin. The recovery of inactive iodide by using the distillation method and column elution were found as $86.5{\pm}0.9%$ and $87.3{\pm}2.7%$, respectively. The recovery and MDA value calculated for distillation technique when 100 g of extracted solution of $^{129}I$ was taken, were found to be $84.6{\pm}1.6%$ and $1.2{\times}10^{-4}Bq/g$, respectively. Consequently, the proposed technique with simplified process lowered the MDA value more than 10 times compared to the column elution technique that has a disadvantage of limited sampling amount.

A Study on Plasma Etching Reaction of Cobalt for Metallic Surface Decontamination (금속 표면 제염을 위한 코발트의 플라즈마 식각 반응 연구)

  • Jeon, Sang-Hwan;Kim, Yong-Soo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • In this study, plasma processing of metal surface is experimentally investigated to enhance the surface decontamination efficiency and to find out the reaction mechanism. Cobalt, the major contaminant in the nuclear facilities, and three fluorine-containing gases, $CF_4/O_2$, $SF_6/O_2$, and $NF_3$ are chosen for the investigation. Thin metallic disk specimens are prepared and their surface etching reactions with the three plasma gases are examined. Results show that the maximum etching rate of $17.2\;{\mu}m/min.$ is obtained with NF3 gas at $420^{\circ}C$, while with $CF_4/O_2$, $SF_6/O_2$ gas plasmas those of $2.56\;{\mu}m/min.$ and $1.14\;{\mu}m/min.$ are obtained, respectively. Along with etching experiments, constituent elements of the reaction products are identified to be cobalt, oxygen, and fluorine by AES (Auger Electron Spectroscopy) analysis. It turns out that the oxygen atoms are physically adsorbed ones to the surface from the ambient not participation ones during the analysis after reaction, which supports that the surface reaction of cobalt is mainly to be a fluorination reaction.

  • PDF

Development of Electrokinetic-Flushing Equipment for a Remediation of Soil Contaminated with Radionuclides (방사성오염토양 제염을 위한 동전기세정장치 개발)

  • Kim, Gye-Nam;Jung, Yun-Ho;Lee, Jung-Joon;Moon, Jei-Kwon;Jung, Chong-Hun;Chung, Un-Soo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.1
    • /
    • pp.1-9
    • /
    • 2008
  • This study examined the effect of an electrokinetic-flushing remediation for a soil of a high permeability. The soil was sampled from the site around a research atomic reactor which had high hydro-conductivities due to a high content of sand in the soil. The flow rate of the washing reagent was fast at the beginning but it was reduced as time lapsed. In the case of using citric acid as a washing reagent, the flow rate was fastest, 78.7 ml/day. The removal efficiencies of $Co^{2+}$ and $Cs^+$ from a soil cell with acetic acid were the highest, which were 95.2% and 84.2% respectively. The soil waste-solution volume generated from the electrokinetic remediation was reduced to about 1/20 of that from the soil washing remediation. Meanwhile, the electrokinetic-flushing method enhanced the removal efficiencies of $Co^{2+}$ and $Cs^+$ from the soil by about 6% and 2% respectively, compared to those by the electrokinetic method. Consequently, it was found that the electrokinetic-flushing method was more effective for the remediation of a soil with a high permeability.

  • PDF

Study of Composite Adsorbent Synthesis and Characterization for the Removal of Cs in the High-salt and High-radioactive Wastewater (고염/고방사성 폐액 내 Cs 제거를 위한 복합 흡착제 합성 및 특성 연구)

  • Kim, Jimin;Lee, Keun-Young;Kim, Kwang-Wook;Lee, Eil-Hee;Chung, Dong-Yong;Moon, Jei-Kwon;Hyun, Jae-Hyuk
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.1
    • /
    • pp.1-14
    • /
    • 2017
  • For the removal of cesium (Cs) from high radioactive/high salt-laden liquid waste, this study synthesized a highly efficient composite adsorbent (potassium cobalt ferrocyanide (PCFC)-loaded chabazite (CHA)) and evaluated its applicability. The composite adsorbent used CHA, which could accommodate Cs as well as other molecules, as a supporting material and was synthesized by immobilizing the PCFC in the pores of CHA through stepwise impregnation/precipitation with $CoCl_2$ and $K_4Fe(CN)_6$ solutions. When CHA, with average particle size of more than $10{\mu}m$, is used in synthesizing the composite adsorbent, the PCFC particles were immobilized in a stable form. Also, the physical stability of the composite adsorbent was improved by optimizing the washing methodology to increase the purity of the composite adsorbent during the synthesis. The composite adsorbent obtained from the optimal synthesis showed a high adsorption rate of Cs in both fresh water (salt-free condition) and seawater (high-salt condition), and had a relatively high value of distribution coefficient (larger than $10^4mL{\cdot}g^{-1}$) regardless of the salt concentration. Therefore, the composite adsorbent synthesized in this study is an optimized material considering both the high selectivity of PCFC on Cs and the physical stability of CHA. It is proved that this composite adsorbent can remove rapidly Cs contained in high radioactive/high salt-laden liquid waste with high efficiency.

An Analysis on the Operation Productivity and Initial Growth of Containerized Seedlings Planted by the Lightweight Planting Auger (경량식혈기를 이용한 용기묘 식재의 작업공정 및 초기생장 분석)

  • Ko, Chi-Ung;Kim, Dong-Hyun;Lee, Kwan-Hee;Kim, Jin-Hyun;Kim, Dong-Geun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.19 no.6
    • /
    • pp.77-86
    • /
    • 2016
  • Due to aging of the rural and mountain populations the labor force is reduced. However work intensity continues to increase, thus, there is a need to improve the current effectiveness of forest operations. This study compared and analyzed the Operation productivity and efficiency of planting containerized seedlings using a battery-powered planting auger and a mattock. Growth was also investigated by looking into the initial growth increments in the planted seedlings. Tasks were investigated by analyzing the process and operation time needed to plant 1 containerized seedling using a planting auger and a mattock. The time spent on the various elements of the planting process was measured with a stopwatch but observations were done continuously. Result of the study shows that with the use of a lightweight planting auger the average time spent to plant a containerized seedling is 18.61 seconds while with the use of a mattock it took an average of 26.96 seconds which clearly demonstrates that the planting auger is more efficient in terms of working hours. Working intensity was also analyzed with the use of a portable heart rate monitor (Polar V800). The average increase in heart rate and work intensity index were analyzed for one planting cycle. It was observed that when using the lightweight planting auger, there was a 46.51% increase in the average heart rate while a 74.67% increase in heart rate when the mattock was used which shows that there is a significant increase in heart rate when mattock is used. In addition, work intensity index was observed to be 29.95% and 47.83% when the planting auger and mattock were used respectively. With the continuous use, work intensity index is significantly higher with the use of the mattock as compared to that of the lightweight planting auger. There were no significant differences on the growth increment of seedlings planted using the different tools until a year after planting, however differences in growth increment were observed after a year. A difference of 15.1 cm in height and 3.41 mm in diameter was observed which shows that the use of lightweight planting auger is excellent for planting containerized seedlings.

Production of cloned Rabbits Embryos and Offsprings by Nuclear Transplantation using In Vitro Matured Oocytes in Rabbits (토끼의 체외배양 난자를 이용한 핵이식으로 복제수정란 및 복제산자의 생산)

  • 박충생;전병균;이경미;윤희준;이효종;곽대오;최상용
    • Journal of Embryo Transfer
    • /
    • v.10 no.1
    • /
    • pp.65-72
    • /
    • 1995
  • The purposes of this study were to produce cloned rabbit embryos and offsprings by nuclear transplantation(NT) using in vitro matured oocytes as nuclear recipient cytoplasm and to determine the effect of frozen nuclei donor embryos on the production efficiency of cloned embryos. The 8cell embryos were collected from the mated does by flushing oviducts with Dulbecco's phosphate buffered saline containing 10% fetal calf serum(FCS) at 40 hours after hGG injection. A portion of collected embryos were preserved at 4$^{\circ}C$ for 24 hours and a portion of them were frozen by vitrification method. The embryos used for donor nuclei were synchronized in the phase of Gi /S transition. The in vitro matured oocytes were used as recipient cytoplasm following removing the nucleus and the first polar body. The synchronized blastomeres from fresh, cooled or frozen embryos were injected into the enucleated oocytes by micromanipulation and were electrofused by electrical stimulation of three pulses for 60 $\mu$sec at 1.0 W /cm in 0.28 M mannitol solution. The fused oocytes were co-cultured with a monolayer of rabbit oviductal epithelial cells in M-199 solution containing 10% FCS for 120 hours at 39$^{\circ}C$ in a 5% $CO_2$incubator. Following in vitro culture of the NT embryos to blastocyst stage, they were stained with Hoechst 33342 dye for counting the number of blastomeres by fluorescence microscopy. The nuclear transplant embryos developed in vitro to 2- to 4-cell stage were transferred into the oviducts of synchronized recipient does. The results obtained were summarized as follows: 1. The fusion rates of the blastomeres from fresh, cooled and frozen embryos with the in vitro matured and enucleated oocytes were 100, 95.8 and 64, 3%, respectively. 2. Development in vitro to blastocyst was significantly(p<0.05) different between the cloned embryos with the blastomeres from fresh, cooled or frozen embryos as 39.0, 20. 9 and 15.7%, respectively. 3. The mean numbers of cell cycle per day during in vitro culture of cloned embryos blastomeres from fresh, cooled or frozen embryos was 1.31, 1.29 and 1.16, respectively. 4. A total of 77 nuclear transplant embryos were transferred into 6 recipient does, of which two offsprings were produced from a foster mother 31 days after embryo transfer.

  • PDF

Economic Feasibility Study of the Life Extension by Reactor Type of Nuclear Power Plant in Korea (우리나라 원자력발전의 노형을 고려한 계속운전의 경제성 비교 연구)

  • Cho, Sungjin;Kim, Yoon Kyung
    • Environmental and Resource Economics Review
    • /
    • v.27 no.2
    • /
    • pp.261-286
    • /
    • 2018
  • This paper evaluated the economic feasibility of the life extension of Kori unit 1 and Wolsong unit 1 according to the types of the nuclear power plants (NPPs) and the life extension period comparing to the levelized costs of energy (LCOE) of the new NPPs, coal-fired plants (CFPs), and combined cycle gas turbine (CCGTs) which proposed in the $7^{th}$ Basic Plan for Electricity Supply and Demand. The economic feasibility of the life extension of NPPs using LCOE method is affected by the types of NPPs, lifetime extension periods, discount rate, and capacity factor. According to the analysis results, the pressurized light water reactor (PWR) is more economical than the pressurized heavy water reactor (PHWR). Comparing the economical efficiency between the life extension of NPPs and other alternatives, the operation of the PWR for 20 years is more economical than the one of new NPPs and CFPs. However, 20 years of life extension of PHWR is more economical than the CCGTs, but less economical than new NPPs and CFPs. In summary, the 20 years of life extension of the NPPs seems to be more, especially for the PWR, which is more cost effective than other generation alternatives. Therefore, the government policy of the life extension of NPPs need to be a selective approach that simultaneously considers both safety and economics rather than closing all NPPs.

Electrorefining Behavior of Zirconium Scrap with Multiple Cathode in Fluoride-Based Molten Salt (불화물계 용융염을 이용한 지르코늄 스크랩의 다중전극 전해정련 거동)

  • Park, Dong Jae;Kim, Seung Hyun;Park, Kyoung Tae;Mun, Jong Han;Lee, Hyuk Hee;Lee, Jong Hyeon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.13 no.1
    • /
    • pp.11-19
    • /
    • 2015
  • The production of nuclear fuel cladding tube is expected to increase with the nuclear power plant expansion. Zirconium(Zr) scrap that is generated during manufacturing is also expected to increase. Zr electrorefining experiment was carried out in the fluoride salt of LiF-KF-ZrF4 using multiple electrode for scale up and improving throughput Zr electrorefiner develop-ment. The Zr reduction peak observed at-0.8 V(vs.Ni). Polarization behavior showed that the amount of applied current increases because of decreasing cell resistance as the number of cathode increases. Experimental results showed the highest recovery rate about 98% at lowest current density of 25.64 mA/cm2 using 6 electrodes. XRD and TG analysis result show that pure Zr was recovered 99.92% and ICP analysis shows that lower impurity content than conventional impurity content of the Anode(97.8%). Electrorefining consumes energy about 7.15 kWh/kg less than 39.7% compared to the Kroll process using 6 electrode width of 20 mm and height of 65 mm. Because of increasing cell efficiency and recovery rate, using multiple cathode is determined as an efficient technique for scale up electrorefining Zr scrap.

A Study on Segmentation Process of the K1 Reactor Vessel and Internals (K1 원자로 및 내부구조물 절단해체 공정에 대한 연구)

  • Hwang, Young Hwan;Hwang, Seokju;Hong, Sunghoon;Park, Kwang Soo;Kim, Nam-Kyun;Jung, Deok Woon;Kim, Cheon-Woo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.4
    • /
    • pp.437-445
    • /
    • 2019
  • After the permanent shutdown of K1 in 2017, decommissioning processes have attracted great attention. According to the current decommissioning roadmap, the dismantling of the activated components of K1 may start in 2026, following the removal of its spent fuel. Since the reactor vessel (RV) and reactor vessel internal (RVI) of K1 contain massive components and are relatively highly activated, their decommissioning process should be conducted carefully in terms of radiological and industrial safety. For achieving maximum efficiency of nuclear waste management processes for K1, we present activation analysis of the segmentation process and waste classification of the RV and RVI components of K1. For RVI, the active fuel regions and some parts of the upper and lower active regions are classified as intermediate-level waste (ILW), while other components are classified as low-level waste (LLW). Due to the RVI's complex structure and high activation, we suggest various underwater segmentation techniques which are expected to reduce radiation exposure and generate approximately nine ILW and nineteen very low level waste (VLLW)/LLW packages. For RV, the active fuel region and other components are classified as LLW, VLLW, and clearance waste (CW). In this case, we suggest in-situ remote segmentation in air, which is expected to generate approximately forty-two VLLW/LLW packages.