• Title/Summary/Keyword: Cycle Length

Search Result 824, Processing Time 0.022 seconds

A Study on the Status of Recognition and Practical Application of Oral Hygiene Devices : with outpatient as the central figure (치과병·의원 내원환자의 구강위생용품에 대한 인지도 및 사용실태에 관한 연구)

  • Kim, Soo-Kyung
    • Journal of dental hygiene science
    • /
    • v.2 no.2
    • /
    • pp.95-103
    • /
    • 2002
  • This study was carried out to investigate recognition level and practical application status of oral hygiene devices through making a survey of Seoul inhabitants. And survey was implemented in order to propose oral hygiene device for household health care activities. The following results were obtained by analyzing personal interviews of 347 commuting patients at two university hospitals and seven dental clinics. 1) The average length of toothbrush head was estimated as 22.3 mm and average changing cycle was 2.3 months. The user ratio of flat-headed brush was estimated as 51.9% and 46.7% were using fluoridated toothpaste. 2) Generally the ratio of toothpick users was higher than other device users. But the user ratio of dental floss was higher than toothpick in case of patients under orthodontic treatment. 3) The patients under orthodontic treatment were not familiar with handling orthodontic toothbrush. Though 45.8% among orthodontic patients recognized this type of toothbrush, only 25.4% of them knew how exactly to use it. 4) It was shown very low user ratio of oral hygiene devices that the patients who had periodontal problem, hypersensitive trouble, halitosis, implant or denture 5) The patients who had halitosis showed the highest user ratio of toothpick. The patients who had separation of teeth showed the highest user ratio of dental floss. The patients who're under orthodontic treatment showed the highest user ratio of interproximal brush and motorized brush. 6) In response to the most interesting dental disease, it's surveyed as follows; 60.3% of dental caries, 24.0% of periodontal disease, 14.8% of false occlusion and 0.9% of oral cancer. 7) Regarding the motivation of using those oral hygiene devices, 45% responded that it was because of recommendation by dental clinics. Among the negative answers, 38.6% responded that it was because of no selection guidance. 31.3% answered that they didn't use hygiene device because it's inconvenient. 12.0% answered that it's difficult to buy and expensive. 7.8% responded that they didn't feel significant improvement. 4.8% answered that dental hospitals and clinics didn't even introduce those hygiene devices. Therefore efficient campaign for those hygiene devices over all Korea nation should be developed and education program must be prepared for each case of patients in every dental hospitals and clinics.

  • PDF

Artificial Multiplication of the Black Soldier Fly(BSF), Hermetia illucens(Diptera: Stratmyidae) Using the Livestock Feces (가축분뇨를 이용한 동애등에 증식기술 개발)

  • Choi, Young-Cheol;Lee, Sang-Beom;Park, Kwan-Ho;Nam, Sung-Hee;Kim, Jong-Gill;Kim, Won-Tae;Choi, Ji-Young
    • Journal of Sericultural and Entomological Science
    • /
    • v.50 no.2
    • /
    • pp.63-70
    • /
    • 2012
  • This study was conducted to investigated the distribution, ecological character and life cycle of Black Soldier Fly(BSF), Hermetia illucens, to determine effects of BSF on composing ability to the livestock feces. The distribution of BSF was defined in all parts of the country in Korea. Its main habitat was found to be areas near cattle sheds, feces sheds, living waste dump grounds, and food waste dump grounds. Excellent species of the bio-conversion using the livestock feces were selected out of two kinds of solider flies(Hermetia illucens and Ptecticus tenebrifer). And effects of BSF on composing ability to the livestock feces were pig feces 0.5 g, cattle feces 0.43 g and chicken feces 0.3 g per a larvae of BSF. In the examination of the ability of BSF to decompose food waste, volume of the livestock feces decreased by weight pig feces 77, cattle feces 83.62 and chicken feces 80%. Observed characteristics of BSF larvae and pupae stage were by developmental stage may be summarized as follows: size and length of larvae and pupae of BSF were higher than in pig feces and mixed sawdust treatments. In order to develop artificial indoor rearing techniques, The pupation and emergence rate were not visible the difference but important factor of the mating and egg-laying was a sun light. And it was visible the difference in mating ratio. Mating rate of H. illucens by seasonal change was the highest from May to July. Mating mostly occurred between 10 : 00 and 12 : 00 during which light intensity is high. As the egg-laying medium for artificial egg collection, calf feed and food waste were most effective. The ratio of egg-laying medium is waste food : sawdust(1 : 1) in volume. For egg-laying materials, flower foam and wood with holes were used; holes sized 3 ~ 5 mm in diameter, 7 ~ 10 mm in depth were most preferred for egg-laying.

Analysis of Respiratory Motional Effect on the Cone-beam CT Image (Cone-beam CT 영상 획득 시 호흡에 의한 영향 분석)

  • Song, Ju-Young;Nah, Byung-Sik;Chung, Woong-Ki;Ahn, Sung-Ja;Nam, Taek-Keun;Yoon, Mi-Sun
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.81-86
    • /
    • 2007
  • The cone-beam CT (CBCT) which is acquired using on-board imager (OBI) attached to a linear accelerator is widely used for the image guided radiation therapy. In this study, the effect of respiratory motion on the quality of CBCT image was evaluated. A phantom system was constructed in order to simulate respiratory motion. One part of the system is composed of a moving plate and a motor driving component which can control the motional cycle and motional range. The other part is solid water phantom containing a small cubic phantom ($2{\times}2{\times}2cm^3$) surrounded by air which simulate a small tumor volume in the lung air cavity CBCT images of the phantom were acquired in 20 different cases and compared with the image in the static status. The 20 different cases are constituted with 4 different motional ranges (0.7 cm, 1.6 cm, 2.4 cm, 3.1 cm) and 5 different motional cycles (2, 3, 4, 5, 6 sec). The difference of CT number in the coronal image was evaluated as a deformation degree of image quality. The relative average pixel intensity values as a compared CT number of static CBCT image were 71.07% at 0.7 cm motional range, 48.88% at 1.6 cm motional range, 30.60% at 2.4 cm motional range, 17.38% at 3.1 cm motional range The tumor phantom sizes which were defined as the length with different CT number compared with air were increased as the increase of motional range (2.1 cm: no motion, 2.66 cm: 0.7 cm motion, 3.06 cm: 1.6 cm motion, 3.62 cm: 2.4 cm motion, 4.04 cm: 3.1 cm motion). This study shows that respiratory motion in the region of inhomogeneous structures can degrade the image quality of CBCT and it must be considered in the process of setup error correction using CBCT images.

  • PDF

An accuracy analysis of Cyberknife tumor tracking radiotherapy according to unpredictable change of respiration (예측 불가능한 호흡 변화에 따른 사이버나이프 종양 추적 방사선 치료의 정확도 분석)

  • Seo, jung min;Lee, chang yeol;Huh, hyun do;Kim, wan sun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.157-166
    • /
    • 2015
  • Purpose : Cyber-Knife tumor tracking system, based on the correlation relationship between the position of a tumor which moves in response to the real time respiratory cycle signal and respiration was obtained by the LED marker attached to the outside of the patient, the location of the tumor to predict in advance, the movement of the tumor in synchronization with the therapeutic device to track real-time tumor, is a system for treating. The purpose of this study, in the cyber knife tumor tracking radiation therapy, trying to evaluate the accuracy of tumor tracking radiation therapy system due to the change in the form of unpredictable sudden breathing due to cough and sleep. Materials and Methods : Breathing Log files that were used in the study, based on the Respiratory gating radiotherapy and Cyber-knife tracking radiosurgery breathing Log files of patients who received herein, measured using the Log files in the form of a Sinusoidal pattern and Sudden change pattern. it has been reconstituted as possible. Enter the reconstructed respiratory Log file cyber knife dynamic chest Phantom, so that it is possible to implement a motion due to respiration, add manufacturing the driving apparatus of the existing dynamic chest Phantom, Phantom the form of respiration we have developed a program that can be applied to. Movement of the phantom inside the target (Ball cube target) was driven by the displacement of three sizes of according to the size of the respiratory vertical (Superior-Inferior) direction to the 5 mm, 10 mm, 20 mm. Insert crosses two EBT3 films in phantom inside the target in response to changes in the target movement, the End-to-End (E2E) test provided in Cyber-Knife manufacturer depending on the form of the breathing five times each. It was determined by carrying. Accuracy of tumor tracking system is indicated by the target error by analyzing the inserted film, additional E2E test is analyzed by measuring the correlation error while being advanced. Results : If the target error is a sine curve breathing form, the size of the target of the movement is in response to the 5 mm, 10 mm, 20 mm, respectively, of the average $1.14{\pm}0.13mm$, $1.05{\pm}0.20mm$, with $2.37{\pm}0.17mm$, suddenly for it is variations in breathing, respective average $1.87{\pm}0.19mm$, $2.15{\pm}0.21mm$, and analyzed with $2.44{\pm}0.26mm$. If the correlation error can be defined by the length of the displacement vector in the target track is a sinusoidal breathing mode, the size of the target of the movement in response to 5 mm, 10 mm, 20 mm, respective average $0.84{\pm}0.01mm$, $0.70{\pm}0.13mm$, with $1.63{\pm}0.10mm$, if it is a variant of sudden breathing respective average $0.97{\pm}0.06mm$, $1.44{\pm}0.11mm$, and analyzed with $1.98{\pm}0.10mm$. The larger the correlation error values in both the both the respiratory form, the target error value is large. If the motion size of the target of the sine curve breathing form is greater than or equal to 20 mm, was measured at 1.5 mm or more is a recommendation value of both cyber knife manufacturer of both error value. Conclusion : There is a tendency that the correlation error value between about target error value magnitude of the target motion is large is increased, the error value becomes large in variation of rapid respiration than breathing the form of a sine curve. The more the shape of the breathing large movements regular shape of sine curves target accuracy of the tumor tracking system can be judged to be reduced. Using the algorithm of Cyber-Knife tumor tracking system, when there is a change in the sudden unpredictable respiratory due patient coughing during treatment enforcement is to stop the treatment, it is assumed to carry out the internal target validation process again, it is necessary to readjust the form of respiration. Patients under treatment is determined to be able to improve the treatment of accuracy to induce the observed form of regular breathing and put like to see the goggles monitor capable of the respiratory form of the person.

  • PDF