• 제목/요약/키워드: Cycle Length

검색결과 824건 처리시간 0.032초

2상류이젝터를 이용하는 $CO_{2}$ 냉동사이클의 성능해석 (Performance analysis of $CO_{2}$ refrigeration cycle with two-phase ejector)

  • 이윤환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권8호
    • /
    • pp.946-952
    • /
    • 2005
  • The $CO_{2}$ refrigeration cycle is expected to reduce the compressor work and increase the COP by applying two-phase ejector as a device for the recovery of dissipated expansion energy. In this study, the performance of the cycle was simulated and effects of the ejector shapes on the performance of the $CO_{2}$ refrigeration cycle were investigated. The following results were obtained through the cycle simulation. The COP of the $CO_{2}$ refrigeration cycle with two-phase ejector flow which expansion is occured in the isentropic manner is increased by a maximum of 24 $\%$ than the basic cycle with expansion valve If the velocity nonequilibrium in the mixing process is assumed the COP of the cycle is increased with the increase of the length and the decrease of the section area of the mixing tube. The best cycle performance is obtained when the divergent angle of diffuser is 7.

Ovarian Cycle, the Biological Minimum Size and Artificial Spawning Frequency in Female Meretrix petechialis (Bivalvia: Veneridae) in Western Korea

  • Jun, Je-Cheon;Kim, Yong-Min;Chung, Jae-Seung;Chung, Ee-Yung;Lee, Ki-Young
    • 한국발생생물학회지:발생과생식
    • /
    • 제16권3호
    • /
    • pp.205-217
    • /
    • 2012
  • The ovarian cycle, the biological minimum size, and artificial spawning frequency by artificial spawning induction of the female hard clam, Meretrix petechialis, were investigated by histological observations and morphometric data. The ovarian cycle of this species can be classified into five successive stages: early active stage, late active stage, ripe stage, partially spawned stage, and spent/inactive stage. The spawning period was from June to September, and the main spawning occurred between July and August when the seawater temperature exceeds over $20^{\circ}C$. The biological minimum size (shell length at 50% of first sexual maturity) in females were 40.39 mm in shell length (considered to be two years of age), and all clams over 50.1 mm in shell length sexually matured. In this study, the mean number of the spawned eggs by spawning induction increased with the increase of size (shell length) classes. In case of artificial spawning induction for the clams > 40.39 mm, the number of spawned eggs from the clams of a sized class was gradually decreased with the increase of the number of the spawning frequencies (the first, second, and third spawning). In the experiments of artificial spawning induction during the spawning season, the interval of each spawning of this species was estimated to be 15-18 days (approximately 17 days).

도로 종류와 도로생애주기별 탄소배출량, 에너지소모량 및 비용에 대한 거시적 분석방법 (Macro-level Methodology for Estimating Carbon Emissions, Energy Use, and Cost by Road Type and Road Life Cycle)

  • 허혜정;백종대
    • 한국도로학회논문집
    • /
    • 제17권2호
    • /
    • pp.143-150
    • /
    • 2015
  • PURPOSES : The authors set out to estimate the related carbon emissions, energy use, and costs of the national freeways and highways in Korea. To achieve this goal, a macro-level methodology for estimating those amounts by road type, road structure type, and road life cycle was developed. METHODS : The carbon emissions, energy use, and costs associated with roads vary according to the road type, road structure type, and road life cycle. Therefore, in this study, the road type, road structure type, and road life cycle were classified into two or three categories based on criteria determined by the authors. The unit amounts of carbon emissions and energy use per unit road length by classification were estimated using data gathered from actual road samples. The unit amounts of cost per unit road length by classification were acquired from the standard cost values provided in the 2013 road business manual. The total carbon emissions, energy use, and cost of the national freeways and highways were calculated by multiplying the road length by the corresponding unit amounts. RESULTS: The total carbon emissions, energy use, and costs associated with the national freeways and highways in Korea were estimated by applying the estimated unit amounts and the developed method. CONCLUSIONS: The developed method can be employed in the road planning and design stage when decision makers need to consider the impact of road construction from an environmental and economic point of view.

PWR환경을 모사한 저주기 피로실험장치 국산화 (Development of Low-Cycle Fatigue Test Rig in Simulated PWR Environments)

  • 정일석;김상재;이용성;홍승열
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.178-183
    • /
    • 2004
  • For developing fatigue design curve of cast stainless steels that would be used in piping material of domestic nuclear power plants, a low-cycle fatigue test rig was built. It is capable of performing tests in pressurized high temperature water environment of PWR. Cylindrical specimens of CF8M were used for the strain-controlled environmental fatigue tests. Fatigue life was measured in terms of the number of cycles with the variation of strain amplitude at 0.04%/s strain rates. The disparity between target length and measured length of specimens was corrected by using finite element method. The corrected test results showed similar fatigue life trend with another previous results.

  • PDF

PVAJT 모션플래너를 이용한 Cubic Spline 보간기의 설계 (Design of Cubic Spline Interpolator using a PVAJT Motion Planner)

  • 신동원
    • 한국기계가공학회지
    • /
    • 제10권3호
    • /
    • pp.33-38
    • /
    • 2011
  • A cubic spline trajectory planner with arc-length parameter is formulated with estimation by summing up to the 3rd order in Taylor's expansion. The PVAJT motion planning is presented to reduce trajectory calculation time at every cycle time of servo control loop so that it is able to generate cubic spline trajectory in real time. This method can be used to more complex spline trajectory. Several case studies are executed with different values of cycle time and sampling time, and showed the advantages of the PVAJT motion planner. A DSP-based motion controller is designed to implement the PVAJT motion planning.

A Study on the Relationship between the Traffic Signal System and the Air Pollutants emitted by the Motor Vehicles at Intersection

  • Hong, Min-Sun;Woo, Wan-Gi;Park, Jong-In
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제9권E호
    • /
    • pp.364-372
    • /
    • 1993
  • The purpose of this study is to analyze traffic patterns by use of TRANSYT-7F Model, and to choose the optimum traffic-light cycle length and cycle splite to improve traffic flow and air quality at Samsung Intersection in Seoul. Emission rates of air pollutants are calculated for three time segments 0700-0900, 0900-1800 and 1800-2000. The traffic volume correlated reasonably well with air pollutants emitted ; however, the phasing and timing of traffic signals was found to equally be important. The results of performance with optimal setting indicate that the best cycle length were 80sec(0700-0900), 95sec(0900-1800) and 90sec(1800-2000), res-pectively. As expected the highest emissions of air pollutants were observed during the evening rush hours (1800-2000). A properly designed signalized intersection can help reduce traffic delay, driver discomfort, fuel consumption, and air pollution by efficiently the capacity of existing intersection.

  • PDF

The Influence of Body Support Treadmill Training with Visual Feedback on the Gait Factors of Stroke Patients

  • Jegal, Hyuk;Kim, Ki Jong;Jun, Hyun Ju
    • 국제물리치료학회지
    • /
    • 제5권2호
    • /
    • pp.708-713
    • /
    • 2014
  • The aim of this research was to investigate how the effects of body supported treadmill training with visual feedback affect the gait factors of stroke patients. Thirty subjects (21 male, 9 female) with a diagnosis of stroke were taken to the hospital to participate in this study. The subjects received body supported treadmill training with visual feedback. The training was executed for 6 minutes, 3 times a day per week for 19 weeks after general exercise. The effects of the visual feedback in the body supported treadmill training were evaluated by measuring the average gait cycle and the average step length of the affected and unaffected. The collected data were statistically analyzed by using a paired t-test. The results of this study were a significant improvement of the average gait cycle and no statistically significant difference of the average step length. The gait cycle average had a statistically significant difference in gender, age, etiology, paretic side, and step length average. There was no statistically significant difference in infarction within etiology. Therefore, it was necessary to apply the easy and simple with the treadmill training in the rehabilitation of the stroke patients. This study will require a variety of outcome measures related to the effects of treadmill training with gait factors.

강의 피로균열지연거동에 미치는 과대하중의 영향과 통계적 변동에 관한 연구 (Influence of overload on the fatigue crack growth retardation and the statistical variation)

  • 김선진;남기우;김종훈;이창용;박은희;서상하
    • 한국해양공학회지
    • /
    • 제11권3호
    • /
    • pp.76-88
    • /
    • 1997
  • Constant .DELTA.K fatigue crack growth rate experiments were performed by applying an intermediate single and multiple overload for structural steel, SM45C. The purpose of the present study is to investigate the influence of multiple overloads at various stress intensity factor ranges and the effect of statistical variability of crack retardation behavior. The normalized delayed load cycle, delayed crack length and the minimum crack growth rate are increased with increasing baseline stress intensity factor range when the overload ratio and the number of overload application were constant. The crack retardation under low baseline stress intensity factor range increases by increasing the number of overload application, but the minimum crack growth rate decreases by increasing the number of overload application. A strong linear correlation exists between the minimum crack growth rate and the number of overload applications. And, it was observed that the variability in the crack growth retardation behavior are presented, the probability distribution functions of delayed load cycle, delayed crack length and crack growth life are 2-parameter Weibull. The coefficient of variation of delayed load cycle and delayed crack length for the number of 10 overload applications data are 14.8 and 9.2%, respectively.

  • PDF

무선 센서 네트워크에서 Duty Cycle의 영향 (Impact of Duty Cycle in Wireless Sensor Networks)

  • 스타핏프라네쉬;변재영
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2008년도 추계종합학술대회 B
    • /
    • pp.854-857
    • /
    • 2008
  • 무선 센서 네트워크의 센서 노드는 내부 전원을 사용함으로 인해 수명이 제한적이다. 기존의 여러 MAC 프로토콜은 무선 센서 네트워크에서 에너지 절약을 위해 sleep/listen cycle을 스케쥴링한다. 또한, MAC프로토콜의 duty-cycle은 사용자의 조정에 의해 낮은 duty cycle로 변화할 수 있으며, 이는 프레임에서 sleep 시간을 결정하게 된다. 이러한 duty cycle의 크기는 MAC 프로토콜의 성능에 직접적인 영향을 미친다. 본 논문에서는 NS-2 환경에서 서로 다른 duty cycle을 갖는 TEEM과 SMAC을 시뮬레이션하고 두 개의 프로토콜의 에너지 소비와 성능 측면에서 duty cycle을 분석한다.

  • PDF

An Experimental Study on the Performance of Inverter Heat Pump with a Variation of Frequency and Capillary Size

  • Choi, Jong-Min;Kim, Yong-Chan;Kim, Jong-Yup
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.27-35
    • /
    • 1998
  • An experimental study was performed to investigate the optimum cycle of an inverter heat pump as a function of frequency. The performance of the inverter heat pump with the rated cooling capacity of 4,141 W(3,550kcal/h) was measured with a variation of frequency, indoor and outdoor temperature, and length of capillary tube in the psychrometric test room. As a base case, the inverter heat pump with the standard capillary length of l,000mm(optimum size for the frequency of 60Hz) and ASHRAE Test condition "A" was tested by varying frequency from 30Hz to 80Hz. Then, the optimum cycles were investigated by varying the length of capillary tube at each frequency level of 30, 60 and 80Hz. Based on the experimental data, the change of system characteristics between the optimum and the base case were analyzed for each selected frequency level. Generally, for low frequency level(30Hz), the longer length of the capillary tube compared with the standard size showed the higher energy efficiency ratio(EER), while for high frequency level(80Hz) the shorter length of the capillary tube showed the higher EER.

  • PDF