• Title/Summary/Keyword: Cyanoacrylate Adhesive

Search Result 20, Processing Time 0.02 seconds

Preservation Values and Effects on Cleaning and Adhesive Agents for Plastic Artifacts (플라스틱 작품의 보존 가치 및 세척제와 접착제의 효능 평가)

  • Chung, Yong Jae;Yu, Ji A;Kang, Dai Ill
    • Journal of Conservation Science
    • /
    • v.29 no.2
    • /
    • pp.127-138
    • /
    • 2013
  • Plastic, widely used as a material for contemporary art, get damaged as directly exposed to temperature, humidity, ultra violet, etc. And it is very quickly damaged in early time, once damaged, it can't recover into original state. But like this characteristics, there is a few advanced research in Korea. So this study deal with a rising value of plastic artifacts in other country, United Kingdom and France, current conservation state, identification and cleaning method. Also 5 types of cleaners(distilled water, ethanol, acetone, eraser) and adhesives(cyanoacrylate, epoxy, acrylic, chloroprene rubber) were evaluated by produced plastics(PVC, PE, PP, PS, PU). As a result of experiment, ethanol and acetone that were previous evaluated in other research performed in other country are the best cleaner. Result of degradation after adhesive, cyanoacrylate and epoxy resin showed better performance and stability. As a basic research, this study is expected that can be used in future researches.

Study on the Basic Survey and Materials Properties for Conservation of Plastic Artifacts: 'A Bag of Alice - a Fish without Eyes' (플라스틱 작품의 기초조사 및 보존처리 재료 연구: 이인희 '앨리스의 가방 - 눈 없는 물고기'를 중심으로)

  • Han, Ye Bin;Kim, Jung Heum;Beom, Dae Geon
    • Journal of Conservation Science
    • /
    • v.34 no.5
    • /
    • pp.379-385
    • /
    • 2018
  • This study examined the condition of degraded plastic artifacts and conducted materials assessments for conservation treatment. The properties and bond characteristics of five types of adhesives(EVA, PVAc, Cyanoacrylate) were evaluated to select the adhesive most suitable for conservation treatment. The degradation of plastic artifacts caused cracks, peelings, and surface warping. According to the FT-IR analysis, the synthetic resin used in the artifact was estimated to EVA type. The properties of the adhesives were evaluated through acidity, and hardness measurements. The results showed that acidity varies with the type of adhesive, and that the hardness of PVAc was higher than those of EVA. On comparing the bond characteristics of the samples after artificial degradation, it was found that PVAc and Cyanoacrylate increased the chromaticity and hardness of the samples, while EVA was the most stable with relatively little change. Thus, EVA was confirmed to be the most suitable materials for conservation treatment of degraded plastic artifacts. In this study, as the experiment of treatment materials based on actual artifact, it is expected that it could be used a basis research for conservation treatment of plastic artifacts.

Biomimetic characteristics of mussel adhesive protein-loaded collagen membrane in guided bone regeneration of rabbit calvarial defects

  • Song, Woong-Kyu;Kang, Joo-Hyun;Cha, Jae-Kook;Lee, Jung-Seok;Paik, Jeong-Won;Jung, Ui-Won;Kim, Byung-Hoon;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.5
    • /
    • pp.305-316
    • /
    • 2018
  • Purpose: The aim of the present study was to evaluate the biocompatibility and barrier function of mussel adhesive protein (MAP)-loaded collagen membranes in guided bone regeneration (GBR). Methods: Eight male New Zealand white rabbits were used. Four circular defects (diameter: 8 mm) were created in the calvarium of each animal. The defects were randomly assigned to 1) a negative control group, 2) a cyanoacrylate (CA)-loaded collagen membrane group (the CA group), 3) a MAP-loaded collagen membrane group (the MAP group), and 4) a group that received a polycaprolactone block with MAP-loaded collagen membrane (the MAP-PCL group). Specimens were harvested at 2 weeks (n=4) and 8 weeks (n=4) postoperatively for observational histology and histometric analysis. Results: In the histologic analysis, MAP was completely absorbed without any byproducts. In contrast, some of the CA adhesive remained, showing an inflammatory reaction, at 8 weeks. In the MAP-PCL group, the MAP-loaded collagen membranes served as a barrier membrane despite their fast degradation in GBR. No significant difference was found in the amount of new bone between the MAP-PCL and MAP groups ($1.82{\pm}0.86mm^2$ and $2.60{\pm}0.65mm^2$, respectively). Conclusions: The MAP-loaded collagen membrane functioned efficiently in this rabbit calvarial GBR model, with excellent biocompatibility. Further research is needed to assess clinical applications in defect types that are more challenging for GBR than those used in the current model.

Removing Resin Contaminants from the Seated Stone Buddha (Korean Treasure No.84) of Sinboksa Temple Site in Gangneung (강릉 신복사지 석조보살좌상 보물 제84호 수지상 오염물 제거 방안 연구)

  • Lee, Byeonghoon;Go, Hyeongsun
    • Conservation Science in Museum
    • /
    • v.15
    • /
    • pp.56-65
    • /
    • 2014
  • The face of the Seated Stone Buddha Korean Treasure No.84 of Sinboksa Templesite in Gangneung was contaminated with a glossy resin, spoiling its beauty. The contaminants covered the face, the forehead of the urna, to the bottom of the jaw. FT-IR analysis on a sample of the contaminants identified the substance as cyanoacrylate instant adhesive, which can normally be melted with acetone and removed with a swab. However, given that the surface of the statue was severely weathered from prolonged open-air exposure, alternative removal procedures were considered, to minimize the possibility of physical damage. After research, two removal procedures were utilized: one procedure involving poultices, which had been used to remove graffiti from the Samjeondobi Stele, and one procedure involving steam sterilization, which has been used to remove resin from pottery and porcelain. When both the poultices and steam sterilization were applied together, the resin was removed within twenty-four hours, without physical work using a swab.

Effect of Occlusion on the Activities of Dermal Xanthine Oxidase in Rats (흰쥐에 있어서 피부노출 차단이 피부조직의 Xanthine Oxidase 활성에 미치는 영향)

  • 한선일;전태원;윤종국
    • Biomedical Science Letters
    • /
    • v.6 no.1
    • /
    • pp.37-43
    • /
    • 2000
  • To investigate an impact of skin occlusion on the dermal xanthine oxidase (XO) activity, the dorsal part in rats was covered with closed petri dish-shaped chamber, 46 mm in diameter and 10 mm in height, which was made of glass. The crack between top of chamber and skin was sealed by an adhesive agent. After 5 days, the quantity of sweat accumulation was about 400 mg, whereas after 10 days that was decreased about to 21 mg. The 5 days skin occlusion showed the more increased activity of dermal XO compared with the control, and the increased ratio of enzyme activity to the control was higher than that of 10 days skin occlusion, with the increase being associated with sweat accumulation in chamber. Furthermore, the V$_{max}$ of dermal XO in 5 days skin occlusion was higher than that in the control. In conclusion, it may be hypothesized that the XO system may play an role for defence mechanism in dermal tissue.

  • PDF

EFFECT OF SALIVARY CONTAMINATION OF TEETH ON MICROTENSILE BOND STRENGTH OF VAR10US DENTIN BONDING SYSTEMS. (타액에 의한 오염이 상아질 접착제의 미세전단결합강도에 미치는 영향)

  • Choi, Kyoung-Kyu;Ryu, Gil-Joo
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.3
    • /
    • pp.203-208
    • /
    • 2003
  • The purpose of this study was to evaluate the effect of salivary contamination of teeth on bonding efficacy of self-priming and self-etching DBSs. The materials used were Single Bond(SB, self-priming system, 3M), Unifil Bond(UB, self-etching system, GC), and Scotchbond Multi-Purpose Plus(SM, 3M) as control. Forty five human molars randomly allocated to three groups as dentin bonding systems tested and embedded in epoxy resin. Then the specimens were wet-ground to expose flat buccal enamel surface or flat occlusal dentin surface and cut bucco-lingually to form two halves with slow speed diamond saw. One of them was used under non-contamination, other under contamination with saliva. The bonding procedure was according to the manufacturer's directions and resin composite(Z-100, 3M Dental Products, St. Paul, MN) was built-up on the bonded surface 5mm high. The specimens were ground carefully at the enamel-composite interface with fine finishing round diamond bur to create an hour-glass shape yielding bonded surface areas of $1.5{\pm}0.1\textrm{mm}^2$. The specimens were bonded to the modified microtensile testing apparatus with cyanoacrylate, attached to the universal testing machine and stressed in tension at a CHS of 1mm/min. The tensile force at failure was recorded and converted to a tensile stress(MPa). Mean values and standard deviations of the bond strength are listed in table. One-way ANOVA was used to determine significant difference at the 95% level. The bond strength of SBMP and SB were not affected by salivary contamination, but that of UB was significantly affected by salivary contamination. These results indicate that DBSs with total etch technique seems less likely affected by salivary contamination in bonding procedure.

Stability and Effectiveness of Laser and Liquiband Treatments in the Rat Model of Oral Ulcer

  • Kang, Ji Won;Ryu, Hyun Seok;Abueva, Celine;Chung, Phil-Sang;Woo, Seung Hoon
    • Medical Lasers
    • /
    • v.10 no.4
    • /
    • pp.207-213
    • /
    • 2021
  • Background and Objectives This study was undertaken to assess the stability and efficacy of laser therapy (808 nm), Liquiband (a commercial topical skin adhesive product), and a combination treatment, for application in oral ulcers. Materials and Methods The oral ulcer rat animal model was used to determine the efficacy of photobiomodulation, Liquiband, or combination therapy. Ulcers were induced by injecting 60% acetic acid in the oral mucosa. Three days after ulcer confirmation, the chemically induced ulcers were treated with either laser (808 nm), Liquiband, or a combination of both, every two days for 8 days (4 sessions). Combination therapy was performed by first treating with laser followed by application of the Liquiband. Reduction in ulcer area size was subsequently determined, and animals were sacrificed at 5 and 10 days after the last administration, for histological observation of the extracted oral ulcer tissue samples. Results In this study, treatment with either laser (808 nm) or commercial Liquiband product as well as the combined treatment significantly enhanced oral ulcer healing in the rat animal model. The effect of laser treatment is mainly attributed to collagen synthesis, whereas application of the Liquiband promotes vascularization and formation of granulation tissue. Our results indicate that further optimization of the combined therapy could synergistically and significantly enhance oral ulcer healing. Conclusion Laser or Liquiband treatment of oral ulcer in the rat animal model exert different outcomes, but both methods confirm significant effects relative to the untreated group. The combined treatment group with laser and Liquiband showed marked oral ulcer healing, but further optimization is required to get highly significant results and establish the potential synergistic effect of the combination therapy, as compared to the individual enhancing effects of healing oral ulcers.

Dismantling and Restoration of the Celadon Stool Treasure with an Openwork Ring Design (보물 청자 투각고리문 의자의 해체 및 복원)

  • KWON, Ohyoung;LEE, Sunmyung;LEE, Jangjon;PARK, Younghwan
    • Korean Journal of Heritage: History & Science
    • /
    • v.55 no.2
    • /
    • pp.200-211
    • /
    • 2022
  • The celadon stools with an openwork ring design which consist of four items as one collection were excavated from Gaeseong, Gyeonggi-do Province. The celadon stools were designated and managed as treasures due to their high arthistorical value in the form of demonstrating the excellence of celadon manufacturing techniques and the fanciful lifestyles during the Goryeo Dynasty. However, one of the items, which appeared to have been repaired and restored in the past, suffered a decline in aesthetic value due to the aging of the treatment materials and the lack of skill on the part of the conservator, raising the need for re-treatment as a result of structural instability. An examination of the conservation condition prior to conservation treatment found structural vulnerabilities because physical damage had been artificially inflicted throughout the area that was rendered defective at the time of manufacturing. The bonded surfaces for the cracked areas and detached fragments did not fit, and these areas and fragments had deteriorated because the adhesive trickled down onto the celadon surface or secondary contaminants, such as dust, were on the adhesive surface. The study identified the position, scope, and conditions of the bonded areas at the cracks UV rays and microscopy in order to investigate the condition of repair and restoration. By conducting Fourier-transform infrared spectroscopy(FT-IR) and portable x-ray fluorescence spectroscopy on the materials used for the former conservation treatment, the study confirmed the use of cellulose resins and epoxy resins as adhesives. Furthermore, the analysis revealed the addition of gypsum(CaSO4·2H2O) and bone meal(Ca10 (PO4)6(OH)2) to the adhesive to increase the bonding strength of some of the bonded areas that sustained force. Based on the results of the investigation, the conservation treatment for the artifact would focus on completely dismantling the existing bonded areas and then consolidating vulnerable areas through bonding and restoration. After removing and dismantling the prior adhesive used, the celadon stool was separated into 6 large fragments including the top and bottom, the curved legs, and some of the ring design. After dismantling, the remaining adhesive and contaminants were chemically and physically removed, and a steam cleaner was used to clean the fractured surfaces to increase the bonding efficacy of the re-bonding. The bonding of the artifact involved applying the adhesive differently depending on the bonding area and size. The cyanoacrylate resin Loctite 401 was used on the bonding area that held the positions of the fragments, while the acrylic resin Paraloid B-72 20%(in xylene) was treated on cross sections for reversibility in the areas that provided structural stability before bonding the fragments using the epoxy resin Epo-tek 301-2. For areas that would sustain force, as in the top and bottom, kaolin was added to Epo-tek 301-2 in order to reinforce the bonding strength. For the missing parts of the ring design where a continuous pattern could be assumed, a frame was made using SN-sheets, and the ring design was then modeled and restored by connecting the damaged cross section with Wood epos. Other restoration areas that occurred during bonding were treated by being filled with Wood epos for aesthetic and structural stabilization. Restored and filled areas were color-matched to avoid the feeling of disharmony from differences of texture in case of exhibitions in the future. The investigation and treatment process involving a variety of scientific technology was systematically documented so as to be utilized as basic data for the conservation and maintenance.

Development of the Fixed Slab Analogy Device for the Measurement of Stress Intensity Factor (응력확대계수 측정용 고정 슬랩상사 장치의 개발)

  • 정진석;최선호;황재석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.11
    • /
    • pp.1999-2010
    • /
    • 1992
  • The fixed slab analogy device which can measure stress intensity factors(S.I.F) experimentally by slab analogy theory is developed in this paper. The margin of errors resulted from the new testing apparatus are between 0.02% and 8.25%. Therefore, it is assured that this one can be effectively used for the more accurate measurement of S.I.F.( $k_{I}$, $k_{I I}$) than conventional apparatus. The pitch of master grating used in this experiment is 0.1mm It is known that the ratio of the distance from crack tip to the crack length on obtaining the accurate stress intensity factor is between 0.4 and 0.7. The optimum curvature radius of slab is about 125mm. The thickness of slab(plate) used in the fixed slab analogy device is 0.05mm(P.V.C. ; E = 64 MN/ $m^{2}$, .nu.=0.38), which is proved to be suitable for the test. The optimum material for the frame(slab`s external boundary) is a alloy tool steel(SKS 5) plate and its thickness is 1mm. In this research, the rigid cracks are directly bonded to the slab surface by cyanoacrylate adhesive for the easiness of slab making and conformity to the practical crack figure. The material of rigid crack is thin steel plate. It is expected that the developed method can be used effectively for the analysis of $k_{I}$ and $k_{I I}$ of arbitrary shaped or distributed cracks.cks.

Evaluation of polymerization shrinkage stress in silorane-based composites (Silorane계 복합레진의 중합수축응력의 평가)

  • Ryu, Seung-Ji;Cheon, Ji-Hoon;Min, Jeong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.3
    • /
    • pp.188-195
    • /
    • 2011
  • Objectives: The purpose of this study was to evaluate the polymerization shrinkage stress among conventional methacrylate-based composite resins and a silorane-based composite resin. Materials and Methods: The strain gauge method was used for the determination of polymerization shrinkage strain. Specimens were divided by 3 groups according to various composite materials. Filtek Z-250 (3M ESPE) and Filtek P-60 (3M ESPE) were used as a conventional methacrylate-based composites and Filtek P-90 (3M ESPE) was used as a silorane-based composites. Measurements were recorded at each 1 second for the total of 800 seconds including the periods of light application. The results of polymerization shrinkage stress were statistically analyzed using One way ANOVA and Tukey test (p = 0.05). Results: The polymerization shrinkage stress of a silorane-based composite resin was lower than those of conventional methacrylate-based composite resins (p < 0.05). The shrinkage stress between methacrylate-based composite resin groups did not show significant difference (p > 0.05). Conclusions: Within the limitation of this study, silorane-based composites showed lower polymerization shrinkage stress than methacrylate-based composites. We need to investigate more into polymerization shrinkage stress with regard to elastic modulus of silorane-based composites for the precise result.