• Title/Summary/Keyword: Cyanides

Search Result 25, Processing Time 0.02 seconds

UV Light Induced Photocatalytic Degradation of Cyanides in Aqueous Solution over Modified $TiO_2$

  • Kim, Hyeong Ju;Kim, Jae Hyeon;Lee, Cheong Hak;Hyeon, Taek Hwan;Choe, Won Yong;Lee, Ho In
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.12
    • /
    • pp.1371-1374
    • /
    • 2001
  • Metal doping was adopted to modify TiO2 (P-25) and enhance the photocatalytic degradation of harmful cyanides in aqueous solution. Ni, Cu, Co, and Ag doped TiO2 were found to be active photocatalysts for UV light induced degradation of aqueous cyanides generating cyanate, nitrate and ammonia as main nitrogen-containing products. The photoactivity of Ni doped TiO2 was greatly affected by the state of Ni, that is, the crystal size and the degree of reduction of Ni. The modification effects of some mixed oxides, that is, Ni-Cu/TiO2 were also studied. The activity of Ni-Cu/TiO2 for any ratio of Cu/Ni was higher than that of Ni- or Cu-doped TiO2, and the catalyst at the Cu/Ni ratio of 0.3 showed the highest activity for cyanide conversion.

Decomposition Characteristics of Cyano-compounds in Non-thermal Packed-Bed-Plasma-Reactor (충전형 저온 플라즈마 반응기에서 시안 화합물의 분해 특성)

  • Ryu, Sam-Gon;Park, Myung-Kyu;Lee, Hae-Wan
    • Korean Chemical Engineering Research
    • /
    • v.50 no.2
    • /
    • pp.343-347
    • /
    • 2012
  • The decomposition behaviors of gaseous cyanides in non-thermal plasma-catalyst hybrid reactor have been investigated with the variation of discharge power, influent concentration of cyanide, humidity of air carrier and packed materials in the reactor. Destruction of cyanides by plasma only process was very difficult compared to that of trichloroethylene. But the destruction efficiencies of cyanides were dramatically improved through packing alumina or Pt/alumina bead in the plasma discharge region. From the results, it could be assumed that thermal catalytic effect is involved simultaneously with plasma in the reaction of cyanides destruction on the alumina or Pt/alumina packed plasma reactor.

Development of Cyanide Sensor Using S. cerevisiae (S. cerevisiae를 이용한 시안센서의 개발)

  • 김종민;이현우
    • KSBB Journal
    • /
    • v.11 no.6
    • /
    • pp.669-675
    • /
    • 1996
  • Two types of cyanide sensor system were constructed for monitoring river water simply. One is membrane type flow system composed of S. cerevisiae coated membrane and oxygen electrode, the other is reactor type flow system composed of S. cevevisiae immobilized reactor and two oxygen electrode. S. cerevisiae and oxygen electrode were used for detecting cyanide compounds. These sensors are based on the inhibition of cyanides on the respiration activity of S. cerevisiae. Membrane type sensor system could detect cyanides ranging 0.10∼1.00ppm, and the respiration activity of S. cerevisiae continued for a day. Reactor type sensor system composed of immobilized chitopearl HP-5020 with S. cerevisiae could detect cyanides in the range of 0.10∼1.00ppm, and maintained 90% respiration activity for sixteen days. It was found that the optimum reactor size exist for the reactor type biosensor when respirating activity inhibition is used for detection of cyanides.

  • PDF

Ion-Sensitive Field Effect Transistor-Based Multienzyme Sensor for Alternative Detection of Mercury ions, Cyanide, and Pesticide

  • Vyacheslav, Volotovskky;Kim, Nam-Soo
    • Journal of Microbiology and Biotechnology
    • /
    • v.13 no.3
    • /
    • pp.373-377
    • /
    • 2003
  • Various groups of industrial and agricultural pollutants (heavy metal ions, cyanides, and pesticides) can be detected by enzymes. Since heavy metal ions inhibit urease, cyanides inhibit peroxidase, organophosphorus and carbamate pesticides inhibit butyrylcholinesterase, these enzymes were co-immobilized into a bovine serum albumin gel on the surface of an ion-sensitive field effect transistor to create a bioprobe that is sensitive to the compounds mentioned above. The sensitivity of the present sensor towards KCN corresponded to $1\;\mu\textrm{M}$ with 1 min of incubation time. The detection limits for Hg(II) ions and the pesticide carbofuran were 0.1 and $0.5\;\mu\textrm{M}$, respectively, when a 10 min sensor incubation time in contaminated samples was chosen. The total time for determining the concentrations of all species mentioned did not exceed 20 min.

Chemical Asphyxiants - Cyanides and Hydrogen Sulfides (화학적 질식제 -청화물과 황화수소를 중심으로)

  • Kim Yang Ho;Choi Young Hee;Lee Choong Ryeol;Lee Ji Ho;Yoo Cheolln;Lee Hun
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.1 no.1
    • /
    • pp.12-20
    • /
    • 2003
  • Cyanides and hydrogen sulfide ($H_2S$) are major chemical asphyxiants. They have common mechanism of action which inhibit cellular respiration and induce histotoxic hypoxia. They do not generate ATP, and all processes dependent on ATP are stopped. No extraction of $O_2$ from blood decreases AV $O_2$ differences, and the shift to anaerobic glycolysis brings about lactic acidosis with high anion gap. The mainstay of the treatment is rapid treatment with appropriate use of antidotes. However, there are several differences between cyanides and $H_2S$. First, $H_2S$ is not metabolized by enzymes such as thiosulfate. Thus thiosulfate does not play any role in treatment of $H_2S$. Second, $H_2S$ is a more potent inhibitor of cytochrome aa3 than cyanide. Third, $H_2S$ induces more divergent neurologic sequele than cyanide. Finally, $H_2S$ is not absorbed via skin.

  • PDF

Chemical Active Liquid Membranes in Inorganic Supports for Metal Ion Separations

  • Yi, Jongheop
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1994.10a
    • /
    • pp.8-11
    • /
    • 1994
  • Disposal of hazardous ions in the aqueous streams is a significant industrial waste problem.. Waste streams from electronics, electroplating, and photographic industries contain metal ions such as copper, nickel, zinc, chromium(IV), cadmium, aluminum, silver, and gold, amongst others in various aqueous solutions such as sulfates, chlorides, fluorocarbons, and cyanides. Typical plating solutions having similar compositions are listed in Table 1. Spent process streams in catalyst manufacturing facilities also contain precious metals such as Ag, Pt, and Pd. Developing an effective recovery process of these metal ions for reuse is important.

  • PDF

Ecotoxicity Estimation of Hazardous Air Pollutants Emitted from Semiconductor Manufacturing Processes Utilizing QSAR

  • Park, Hyung-Geun;Yeo, Min-Kyeong
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.12
    • /
    • pp.3755-3761
    • /
    • 2013
  • This study aims to assess the ecological risk of the hazardous air pollutants (HAPs) emitted in the semiconductor manufacturing processes in Korea by using Quantitative Structure Activity Relationship (QSAR, EPA, US, EPI $Suite^{TM}$ 4.1). Owing to the absence of environmental standards of hazardous air pollutants in the semiconductor manufacturing processes in Korea, 18 HAPs in the semiconductor field included in both the US EPA NESHAPs and the hazardous air pollutant list of Ministry of Environment in Korea were selected. As a results 8 chemicals (44.4%) of the selected 18 HAPs were VOCs. Cyanides (cyanides) and ethylene oxides (epoxy resins), and tetrachloro-ethylene (aliphatic compounds, halides) showed long half-lives. Cyanide HAPs especially had the highest half-life with the estimated value of 356.533 days. Nickel compounds (heavy metal compounds) possessed the highest water solubility followed by acetaldehyde (aldehyde compounds), ethylene oxides, and 1,4-dioxanes. The halides, including tetrachloro-ethylenes, carbon tetra-chlorides, benzene (aromatic compounds), and lead (heavy metals), are estimated to take the longest time for biodegradation. Tetrachloroethylene, with the acute toxicity end point of 3.685-7.033 mg/L, was assessed to be the most highly toxic substance among the 18 HAPs. However, considering the absence of the HAPs in the common category of log $K_{ow}{\geq}4$and $BCF{\geq}500$, which indicates the standard of bioconcentration potentials, potentials of the bioconcentration are considered to be low.