• Title/Summary/Keyword: Cutting system

검색결과 1,891건 처리시간 0.035초

중년층 한국인 하악 제1소구치의 표준화 연구 (A Study of the Standardization in the Mandibular First Premolar of the Middle Aged Korean)

  • 전경진;이호중;정동택
    • 한국정밀공학회지
    • /
    • 제23권2호
    • /
    • pp.154-163
    • /
    • 2006
  • Tooth morphology is the most important scientific aspect of dental medicine in regards to the treatment and study of teeth attrition relating to the absence of teeth due to dental caries or the occlusion of teeth due to external force. Most of the studies have focused on the external morphology in cutting teeth regardless of sex and age. However, the importance of internal morphology in the treatment of damaged teeth has been increased. Therefore, this study established the measurement criteria for the morphology of the mandibular first premolar which had never been presented, in order to investigate the external and internal morphologies of mandibular first premolars, and introduced a non-destructive method such as a microcomputed tomogrphy. Mandibular first premolars in superlative state were taken from molars of middle aged males and females and used as specimens for this study. Criteria relating to the internal and external morphology measurements were established to quantify the length of the teeth in identical state. Two dimensional image data for the selected mandibular first premolar were obtained by taking the image of each O.022mm section, which is perpendicular to the vertical direction using the microcomputed tomography. The Vworks program was applied to measure the length of each morphological part according to the set measurement criteria. These measured data were compared with the data presented by G. V. Black and the internal and external morphologies of the teeth of middle aged Koreans were also compared according to gender. In addition, the methodology for measurement of the mandibular first premolar was presented and according to this, the standardized mandibular first premolars of middle aged Korean males and females were made by using a rapid prototyping system.

Computational Study on the Hemodynamics of the Bypass Shunt Directly Connecting the left Ventricle to a Coronary Artery

  • Shim Eun Bo;Lee Byung Jun;Ko Hyung Jong
    • Journal of Mechanical Science and Technology
    • /
    • 제19권5호
    • /
    • pp.1158-1168
    • /
    • 2005
  • A shunt from the left ventricle to the left anterior descending artery is being developed for coronary artery occlusive disease, in which the shunt or conduit connects the the left ventricle (LV) with the diseased artery directly at a point distal to the obstruction. To aid in assessing and optimizing its benefit, a computational model of the cardiovascular system was developed and used to explore various design conditions. Computational fluid dynamic analysis for the shunt hemodynamics was also done using a commercial finite element package. Simulation results indicate that in complete left anterior descending artery (LAD) occlusion, flow can be returned to approximately 65% of normal, if the conduit resistance is equal for forward and reverse flow. The net coronary flow can increase to 80% when the backflow resistance is infinite. The increases in flow rate produced by asymmetric flow resistance are enhanced considerably for a partial LAD obstruction, since the primary effect of resistance asymmetry is to prevent leakage back into the ventricle during diastole. Increased arterial compliance has little effect on net flow with a symmetric shunt, but considerably augments it when the resistance is asymmetric. The computational results suggest that an LV-LAD conduit will be beneficial when the resistance due to artery stenosis exceeds 27 PRU, if the resistance is symmetric. Fluid dynamic simulations for the shunt flow show that a recirculating region generated near the junction of the coronary artery with the bypass shunt. The secondary flow is induced at the cutting plane perpendicular to the axis direction and it is in the attenuated of coronary artery.

탄소량을 고려한 도로 유지보수 경제성에 관한 연구: KPRP (Korea Pavement Research Program) 활용 (A Study on Economic Feasibility of Highway Maintenance Considering Carbon Amount by Using KPRP (Korea Pavement Research Program))

  • 응웬띤탄;최재호
    • 대한토목학회논문집
    • /
    • 제37권5호
    • /
    • pp.879-890
    • /
    • 2017
  • 기존 미국의 포장 설계법(AASHTO)과 대표적인 도로포장 유지보수 의사결정시스템인 HDM-4는 국내 실정 또는 환경에 적합하지 않아 현실적인 도로설계, 시공 및 유지관리 차원에서 국내에 적합하지 않다. 포장 수명 연장에 따른 환경비용에서도 차이가 발생할 것으로 판단되는 바, 본 연구의 주요 목표는 대한민국의 환경조건과 차종별 특성을 반영한 한국형 도로포장 설계법(KPRP) 설계 소프트웨어의 도로 공용성 해석 모델을 기반으로 활용하여 운영 및 유지보수단계에서 대표적인 세 가지 유지보수전략별 LCCC 계산을 통해 최적 대안을 선정하는 것이다. 본 연구 결과 40년 동안의 누적 탄소배출량은 대안 2의 절삭 및 덧씌우기가 누적 탄소배출량과 LCCC의 현재가치비용이 제일 적은 것으로 분석되었다. 본 연구를 통해 다양한 도로관리 유지보수 공사별 $CO_2$배출 원단위 구축이 가능하며 향후 탄소요금의 증가에 따른 도로시설별 다양한 유지관리 전략 마련에 대한 기초연구를 수행하였다는 점에 의의가 있다.

Yeast Artificial Chromosome의 효율적인 조작과 분석을 위한 새로운 Bicistronic Fragmentation Vector의 개발에 관한 연구 (A New Bicistronic Fragmentation Vector for Manipulation and Analysis of Functional Yeast Artificial Chromosomes (YACs))

  • 임향숙;최주연;김인경;강성만;성영모
    • 미생물학회지
    • /
    • 제35권1호
    • /
    • pp.28-34
    • /
    • 1999
  • 본 연구에서는 Yeast Artificial Chromosome을 효율적으로 조작하고 유유전자의 기능을 보다 더 용이하게 분석하기 위해 EMCV 바이러스의 IRES 염기서열과 $\beta$-galactosidase를 포함하는 새로운 bicistronic fragmentation vector를 제조하였다. 이 벡터의 폴리클로닝 site에 네 개의희귀한 제한효소 부위를 도입하여 DNA를 용이하게 클로닝할 수 있게 만들었다. 그러므로 원하는 어떤 YAC도 효모세포에서 쉽게 상동 재조함에 의해 절편할 수 있는 장점이 있다. 이 bicistronic fragmentation vector 시스템을 이용하면하나의 메시지로부터 연구하고자 하는 유전자와 $\beta$-galactosidase를 동시에 한 세포에서 발현할 수 있기 때문에 유전자의 발현양상을 쉽게 분석할 수 있는 새로운 도구로 이용할 수 있다.

  • PDF

유산완충액을 이용한 인공치아우식의 형성에 미치는 산의 농도와 pH에 관한 연구 (THE EFFECT OF ACID CONCENTRATION AND pH OF LACTATE BUFFER SOLUTION ON THE PROGRESS OF ARTIFICIAL CARIES LESION IN HUMAN TOOTH ENAMEL)

  • 박성호;이찬영;이정석
    • Restorative Dentistry and Endodontics
    • /
    • 제18권2호
    • /
    • pp.277-290
    • /
    • 1993
  • Dental caries is considered to be caused by demineralization by organic acid produced by microorganism. But the formation of subsurface lesion in initial caries make it diffcult to explain by simple demineralization. This study is carried out on the basis of thermodynamic concept proposed by Margolis and Moreno. The purpose of this study is to evaluate the effects of acid concentration and pH of lactate buffer system on the artificial caries lesion progress. 160 teeth without any crack, defect or opaque enamel were used and coated with nail varnish except the window ($2{\times}3$ mm). Under the constant degree of saturation(D.S.). The teeth were divided into 8 groups according to acid concentration(10mM, 25mM, 50mM, 100mM) and pH(4.3, 5.0, 6.0). Each group was immersed in buffer solution for 3, 6, 9, 18 days under controlled temperature($25^{\circ}C$). After cutting through the window and grinding, the specimens, 100-150 um in thickness, were imbibed in water or air and examined using polarilizing microscope. The depth of the surface and subsurface surface lesion were measured. 1. In the constant pH and D. S. value, the subsurface lesion progresses more rapidly as the concentration of lactic acid increases. (0.01, 0.025, 0.05, 0.1) 2. In the constant acid concentration and DS value, the subsurface lesion progresses more slowly as the pH increases. (4.3, 5.0, 5.5, 6.0) 3. The width of surface lesion seems to be constant independant of pH and acid concentration.

  • PDF

Reliability-based Optimization for Rock Slopes

  • 이명재
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1998년도 터널.암반역학위원회 박사학위 논문집
    • /
    • pp.3-34
    • /
    • 1998
  • The stability condition of rock slopes is greatly affected by the geometry and strength parameters of discontinuities in the rock masses. Rock slopes Involving movement of rock blocks on discontinuities are failed by one or combination of the three basic failure modes-plane, wedge, and toppling. In rock mechanics, practically all the parameters such as the joint set characteristics, the rock strength properties, and the loading conditions are always subject to a degree of uncertainty. Therefore, a reasonable assessment of the rock slope stability has to include the excavation of the multi-failure modes, the consideration of uncertainties of discontinuity characteristics, and the decision on stabilization measures with favorable cost conditions. This study was performed to provide a new numerical model of the deterministic analysis, reliability analysis, and reliability-based optimization for rock slope stability. The sensitivity analysis was carried out to verify proposed method and developed program; the parameters needed for sensitivity analysis are design variables, the variability of discontinuity properties (orientation and strength of discontinuities), the loading conditions, and rock slope geometry properties. The design variables to be optimized by the reliability-based optimization include the cutting angle, the support pressure, and the slope direction. The variability in orientations and friction angle of discontinuities, which can not be considered in the deterministic analysis, has a greatly influenced on the rock slope stability. The stability of rock slopes considering three basic failure modes is more influenced by the selection of slope direction than any other design variables. When either plane or wedge failure is dominant, the support system is more useful than the excavation as a stabilization method. However, the excavation method is more suitable when toppling failure is dominant. The case study shows that the developed reliability-based optimization model can reasonably assess the stability of rock slopes and reduce the construction cost.

  • PDF

Air abrasion 기술을 이용한 유치 및 영구치의 수복 (TREATMENT OF PRIMARY AND PERMANENT TEETH WITH THE AIR-ABRASIVE TECHNOLOGY)

  • 조현;이광희;김대업;송인경
    • 대한소아치과학회지
    • /
    • 제29권2호
    • /
    • pp.210-216
    • /
    • 2002
  • Air-abrasion 기술은 입자의 운동에너지를 이용하여 비기계적인 방법으로 치아를 처리하거나 치아표면에 존재하는 착색이나 치석을 제거하는 방법으로서, 환자의 불안이나 불편감을 증가시킬 수 있는 압력, 진동이나 열의 발생이 적고 건전한 치질의 보존이 용이하며 특히 소아환자에서 마취의 필요성을 감소시키고 시술부위에서의 타액오염을 가능성을 줄여주고 건조한 시술부위 유지에 용이하고 수복재의 결합력을 증가시켜주는 등의 여러 장점을 지니고 있어, 복합레진을 위한 와동형성, 열구전색을 위한 치아형성, 산 부식 대신 또는 산부식전 치아표면의 처리, 초기 우식증의 진단 등에 이용될 수 있다. 본 증례는 유중절치의 인접면 우식치료, 유구치의 교합면 우식치료, 제1대구치의 우식치료 및 우식 예방을 air abrasion 기술을 사용하여 수복한 바, 환자의 행동조절 및 시술부위의 완전한 건조가 어려운 소아환자에게 있어 임상적으로 유용하다고 여겨지며 양호한 결과를 얻었기에 보고하는 바이다.

  • PDF

TTS기반에서 디지털 서명의 실행 인증을 통한 에이전트의 무결성 보장 기법 (Integrity Guarantee Scheme of Mobile Agents through Authentication of Digital Signature with TTS)

  • 정창렬;윤홍상
    • 한국통신학회논문지
    • /
    • 제31권6C호
    • /
    • pp.651-657
    • /
    • 2006
  • 여기는 본 논문은 이동 에이전트의 안전한 수행을 보장하기 위한 TTS기반의 디지털 서명 실행 인증 기법을 제안한다. 즉 기존의 연구의 문제점인 처리과정에서 발생하는 시스템의 처리속도와 네트워크의 트래픽을 개선한다. 또한 효율적이고 안전한 이동 에이전트의 실행과 무결성을 보장하기 위해 디지털 서명을 이용한다. 디지털 서명은 합성함수와 공개키 기반의 암호화 알고리듬 그리고 해시함수를 이용한 인증서 체인을 한다. 그리고 디지털 서명의 인증서 체인을 이용할 경우, 공격자에 의해서 체인을 끊고 새로운 인증서를 생성하여 삽입하는 공격으로부터 안전하게 보호한다. 또한 공격자에 의해 정직한 호스트를 악의적으로 이용될 수 있는 위협으로부터 보호한다. 그리고 컴퓨터 실험을 통해 인증서 처리에 대한 시스템의 처리속도와 실시간 처리를 분석한다. 이러한 분석을 통해서 시스템의 오버헤드와 네트워크의 트래픽에 대한 효율성을 증명한다.

스프링 격발형 생검총 구조를 가진 생검 시술 자동화 로봇 말단장치 (A Robot End-effector for Biopsy Procedure Automation with Spring-Triggered Biopsy Gun Mechanism)

  • 원종석;문영진;박상훈;최재순
    • 제어로봇시스템학회논문지
    • /
    • 제22권8호
    • /
    • pp.590-596
    • /
    • 2016
  • Biopsy is a typical needle type intervention procedure performed under radiographic image equipment such as computed tomography (CT) and cone-beam CT. This minimal invasive procedure is a simple and effective way for identifying cancerous condition of a suspicious tissue but radiation exposure for the patients and interventional radiologists is a critical problem. In order to overcome such trouble and improve accuracy in targeting of the needle, there have been various attempts using robot technology. Those devices and systems, however, are not for full procedure automation in biopsy without consideration for tissue sampling task. A robotic end-effector of a master-slave tele-operated needle type intervention robot system has been proposed to perform entire biopsy procedure by the authors. However, motorized sampling adopted in the device has different cutting speed from that of biopsy guns used in the conventional way. This paper presents the design of a novel robotic mechanism and protocol for the automation of biopsy procedure using spring-triggered biopsy gun mechanism. An experimental prototype has been successfully fabricated and shown its feasibility of the automated biopsy sequence.

분할디스크형 글라스레이저 증폭기의 온도분포특성에 관한 연구 (Study on the properties of temperature distribution at the split-disk geometry glass laser amplifier)

  • 김병태
    • 한국광학회지
    • /
    • 제3권4호
    • /
    • pp.227-233
    • /
    • 1992
  • 분할디스크형 글라스레이저 증폭기를 개발하기 위하여 이를 해석 설계할 수 있는 시뮬레이션 코드를 작성했다. 레이저매질에서의 열부하를 감소시키고, 플래시램프의 방사스펙트럼과 레이저글라스의 흡수 스펙트럼 간의 결합효율을 높이기 위해서는 전류밀도를 2000-4000A/$\textrm{cm}^{2}$로 유지하여 단파장에서의 방사에너지를 줄여야 한다. 디스크 증폭기에서 같은 부피를 갖는 매질을 3등분하여 냉각표면적을 3배로 늘렸을 때 온도상승치는 30% 정도로 떨어졌다. 단면펌핑 분할 디스크형 증폭기의 설계에서는 각 글라스 간의 $Nd^{3+}$ 도핑율에 차등을 주어야 하고 플래시램프 앞에 있는 매질의 흡수계수 $\alpha$ 와 두께 d의 곱인 $\alpha$d가 0.26 전후가 적절하다는 것을 알았다.

  • PDF