• Title/Summary/Keyword: Cut off angle

Search Result 85, Processing Time 0.023 seconds

Studies on fabrication of 0.5$mu$m GaAs power MESFET's using a conventional UV lithography and angle evaporations (Conventional UV 리소그라피와 경사각증착에 의한 0.5$mu$m 전력용 CaAs MESFET 제작에 관한 연구)

  • 이일형;김상명;윤진섭;이진구
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.12
    • /
    • pp.130-135
    • /
    • 1995
  • GaAs power MESFET's with 0.5 .mu.m gate length using a conventional UV lithography and angle evaporations are fabricated and then DC and RF characteristics are measured and carefully analyzed. The 0.5$\mu$m GaAs power MESFET's are fabricated on epi-wafers which have an undoped GaAs layer inbetween n+ and n GaAs layers grown by MBE, and by the processes such as an image reversal(IR), air-bridge, and our developed 0.5 .mu.m gate fabrication techniques. The total gate widths of the fabricated 0.5$\mu$m GaAs power MESFETs are 0.6-3.0 mm, the current saturation of them 80-400 mA, the maximum linear and RF output power of them 60-265 mW. The current gain cut-off frequencies for the 0.5$\mu$m GaAs power MESFETs varies 13-16 GHz. For the test frequency of 10 GHz the maximum unilateral transducer power gains and the power added efficiencies of the GaAs power devices are 7.0-2.5 dB and 35.68-30.76 %, respectively.

  • PDF

The Evaluation of Images with Various Filters in I-131 SPECT/CT (I-131 SPECT/CT에서 Ringing Artifact 감소를 위한 다양한 Filter값의 적용)

  • Kim, Ha Gyun;Kim, Soo Mee;Woo, Jae Ryong;Oh, So Won;Lee, Jae Sung;Kim, Yu Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.62-68
    • /
    • 2014
  • Purpose: After I-131 therapy, SPECT/CT is useful in identifying location of thyroid remnants and metastasis of thyroid cancers. An excessive uptake of thyroid leads to a ringing artifact in the SPECT images. The aim of this study is to investigate and suggest a proper post filters to remove ringing artifact and produce better image quality. Materials and Methods: A low-cost, customized thyroid-mimicking phantom, consisting of an acrylic bottle and a hollow sphere was used for SPECT/CT Discovery (GE Healthcare, USA). It was filled with I-131 solution. The ratio of hollow sphere to background were varied as 50:1, 200:1, 1000:1 and 4000:1. Acquired images were reconstructed by OSEM (2 iterations, 10 subsets) with and without Evolution (resolution recovery correction, GE). Three different post-filters were applied; Butterworth (cut off: 0.38 to 0.58 with intervals of 0.05), Hanning (cut off: 0.8 to 1 with intervals of 0.05) and Gaussian (FWHM: 3 to 5 with intervals of 0.5) filters. Contrast, background variability, air area variability, and full width half maximum (FWHM) were compared. Results: Higher contrasts were obtained from the SPECT images with Evolution than without Evolution. In the case of images without Evolution, image distortion such as star artifact was generated. For all sphere-to-background ratio, the Butterworth filter showed better constrasts and FWHMs than other two filters, but the ringing artifact was still generated in all studies except 50:1 and it was decreased as cutoff value was increased. The ringing artifact didn't appear with Hanning and Gaussian filters at all studies, however constrats and FWHMs with Gaussian was worse than Hanning filter. For the images having ringing artifacts, the background variability and air area variability were increased. Conclusion: In this study, we suggested that it is desirable to use Hanning filter when the ringing artifact is generated and to use Butterworth filter when ringing artifact is not generated in I-131 SPECT.

  • PDF

K-band MMIC Oscillator Design Using the PHEMT (PHEMT소자를 이용한 K-band MMIC 발진 설계)

  • 이지형;채연식;조희철;윤용순;이진구
    • Proceedings of the IEEK Conference
    • /
    • 2000.06b
    • /
    • pp.88-91
    • /
    • 2000
  • An MMIC oscillator operating at the 24.55 GHz has been designed using 0.2 ${\mu}{\textrm}{m}$AlGaAs/InGaAs/GaAs Pseudomorphic HEMT technology. The active device used in the oscillator design has a 0.2 ${\mu}{\textrm}{m}$ gate length PHEMT with 4$\times$80 ${\mu}{\textrm}{m}$ gate width. We obtained 4.08 dB of S$_{21}$ gain and 317 mS/mm of transconductance, and extrapolated unit current gain cut-off frequency (f$_{T}$) and maximum oscillation frequency (fmax) were 62 GHz and 120 GHz, respectively. The circuit are based on a series feedback and negative resistance topology. Microstrip line open stub is used to terminating. The oscillator circuits has designed for delivering maximum power to load and conjugated matching. The simulated small signal negative resistance was 50 Ω. We obtained 1.002 of loop gain and 0.0005$^{\circ}$angle from the simulation by HP libra 6.1. The layout for oscillator is 1.2$\times$1.8 $\textrm{mm}^2$.>.

  • PDF

The Study on the Aeroelastic Stability of Hingeless Helicopter Rotor in Hover Considering Parametric Angle Changes (파라메타 각 변화를 고려한 힌지없는 헬리콥터 로우터의 공력탄성학적 안정성)

  • 한창헌;김승조
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.386-391
    • /
    • 1998
  • The effect of the changes in parameter angles(precone, droop, sweep) on the lead-lag damping was focused on. Experiment was made with hingeless 4-blade rotors and NACA 0012 airfoil. For the measurement of the rotating natural frequencies and lead-lag damping, non-rotating swash plate was oscillated at the regressing lag mode frequency and the data were acquired after the excitation was cut off. Analysis was made using a finite element formulation based on Hamilton's principle. The main blade is assumed as elastic beams. Quasi-steady strip theory is used to obtain aerodynamic forces, and non-circulatory forces are also included.

  • PDF

Ir-192 Brachytherapy Planning of Brain Tumor (Ir-192 방사성소선원에 의한 뇌종양의 치료계획)

  • Choi Tae Jin;Park Jeong Ho;Kim Ok Bae;Suh Soo Ji
    • Radiation Oncology Journal
    • /
    • v.6 no.2
    • /
    • pp.277-281
    • /
    • 1988
  • Although widely used in external beam treatment planning, computed tomography scans are infrequent in incranial tumors by implanting of Radioactive isotope. This incranial brachytherapy has only become possible by using CT scans and stereotaxic operation methods. The coincidence of single source and tumor axes in brachytherapy is very important to determine the therapeutic dosages. Eventhough using the CT scan, according to spatial location of tumor tying, the section of tumor will be seen enlargement, cause the tumor will be cut off with slight angle to its axes. Correct analysis of tumor size from source is required for rotated axes in analytical geometry.

  • PDF

On the Stochastic Stability Criteria for the Analysis and Simulation of Ocean Waves (수치실험조건에 따른 해양피낭특성의 통계적 안정한계)

  • RYU Cheong-Ro;KIM Hyeon-Ju
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.20 no.5
    • /
    • pp.457-462
    • /
    • 1987
  • Stochastic stability criterias for ocean wave analysis add simulation are studied using the data simulated by the linear superposition method. To clarify the criterias, the effects of the simulation parameters on the variance of stochastic properties of ocean waves are investigated, and the stable conditions of the parameters are estimated through the comparative study on the stochastic properties of simulated waves and well-known ocean waves. The simulation parameters considered are high frequency cut-off, data length, and number and phase angle of component waves. Statistical characteristics analysed are wave height, period and steepness, and the formation of groups of higher waves, resonance periods, steeper higher waves and extreme run-length of the run.

  • PDF

Control Method for Reducing the THD of Grid Current of Three-Phase Grid-Connected Inverters Under Distorted Grid Voltages

  • Tran, Thanh-Vu;Chun, Tae-Won;Lee, Hong-Hee;Kim, Heung-Geun;Nho, Eui-Cheol
    • Journal of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.712-718
    • /
    • 2013
  • This paper proposes a control method for reducing the total harmonic distortion (THD) of the grid current of three-phase grid-connected inverter systems when the grid voltage is distorted. The THD of the grid current caused by grid voltage harmonics is derived by considering the phase delay and magnitude attenuation due to the hardware low-pass filter (LPF). The Cauchy-Schwarz inequality theory is used in order to search more easily for the minimum point of the THD. Both the gain and angle of the compensation voltage at the minimum point of the THD of the grid current are derived with the variation of cut-off frequencies of the hardware LPF. Simulation and experimental results show the validity of the proposed control methods.

A Study on Sensorless Control of a PMSM using Sliding Mode Observer in High Speed Range (슬라이딩 모드 관측기를 이용한 고속 영역에서의 PMSM 센서리스 제어에 관한 연구)

  • 강계룡;김장목;이상혁;황근배;김경훈
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.1
    • /
    • pp.30-36
    • /
    • 2004
  • An iterative sliding mode observer is proposed to sensorless control of a PMSM(Permanent Magnet Synchronous Motor). The proposed sliding mode observer has the character which is robust to the disturbance and parameters variation. A low pass filter with the variable cut-off frequency is also proposed to compensate the delay of the rotor angle according to the rotor speed, it is led to save memory and minimize operation time. Experimental results show that the proposed sliding mode observer leads to the proper performance.

Prediction of Possible Intercept Time by Considering Flight Trajectory of Nodong Missile

  • Lee, Kyounghaing;Oh, Kyunngwon
    • International Journal of Aerospace System Engineering
    • /
    • v.3 no.2
    • /
    • pp.14-21
    • /
    • 2016
  • This paper presents research on predicting the possible intercept time for a Nodong missile based on its flight trajectory. North Korea possesses ballistic missiles of various ranges, and nuclear warhead miniaturization tests and ballistic missile launch tests conducted last year and in previous years have made these missiles into a serious security threat for the international community. With North Korea's current miniaturization skills, the range of the nuclear capable Nodong missiles can be adjusted according to their use goals and operating environment by using a variety of adjustment methods such as payload, fuel mass, Isp, loft angle, cut-off, etc., and therefore precise flight trajectory prediction is difficult. In this regards, this research performs model simulations of the flight trajectory of North Korea's domestically developed Nodong missiles and uses these as a basis for predicting the possible intercept times for major ballistic missile defense systems such as PAC-3, THAAD, and SM-3.

Statistical Fingerprint Recognition Matching Method with an Optimal Threshold and Confidence Interval

  • Hong, C.S.;Kim, C.H.
    • The Korean Journal of Applied Statistics
    • /
    • v.25 no.6
    • /
    • pp.1027-1036
    • /
    • 2012
  • Among various biometrics recognition systems, statistical fingerprint recognition matching methods are considered using minutiae on fingerprints. We define similarity distance measures based on the coordinate and angle of the minutiae, and suggest a fingerprint recognition model following statistical distributions. We could obtain confidence intervals of similarity distance for the same and different persons, and optimal thresholds to minimize two kinds of error rates for distance distributions. It is found that the two confidence intervals of the same and different persons are not overlapped and that the optimal threshold locates between two confidence intervals. Hence an alternative statistical matching method can be suggested by using nonoverlapped confidence intervals and optimal thresholds obtained from the distributions of similarity distances.