• 제목/요약/키워드: Customized implant

검색결과 97건 처리시간 0.022초

DENTIS 내부연결형 서브머지드 임플란트에서 지대주 선택에 따른 성공률의 후향적 연구 (A retrospective randomized study of success rates according to abutment selection in DENTIS submerged implant with an internal hex connection)

  • 김은희;이정은;황희성;김철훈;김정한;김복주
    • 대한치과의사협회지
    • /
    • 제56권11호
    • /
    • pp.605-614
    • /
    • 2018
  • PURPOSE. The purpose of this study is to determine the efficacy of the DENTIS submerged-type implant with an internal hex connection and to build corresponding abutment-selection criteria. MATERIAL AND METHODS. A total of 204 patients received submerged implant fixtures with an internal hex connection at the Dong-A University Hospital Dental clinic in Busan from January 2013 and May 2016. Three specific abutments, UCLA abutments, customized abutments, ready-made abutments, were randomly selected. Implant success was defined as the basis of the International Congress of Oral Implantologists(ICOI, 2007) criteria. The relationship between the implant success rate and the abutment factor was analyzed using the Kruskal-Wallis test(P<.05). RESULTS. A total of 508 implants were placed in 204 patients. After a mean observation period of 38.6 months, 493 out of 508 implants were in normal function, yielding an overall success rate of 97.05%. A total of 15 implants failed: 10 in the maxillary molar area, 4 in the mandibular molar area, and 1 in the mandibular incisal area. All of the implant failures occurred in a single-implant prosthesis, especially high in the maxillary molar area. The Kruskal-Wallis analysis showed that abutment selection has no significant correlation with implant failure(P>.05). CONCLUSION. DENTIS submerged implants with an internal hex connection showed predictable results with a success rate of 97.05%. It is no influence on the success rate in the selection of submerged implant abutment with an internal hex connection.

  • PDF

CORRELATION ASSESSMENT BETWEEN RESONANCE FREQUENCY ANALYSIS AND RADIOGRAPHIC METHOD ACCORDING TO PERI-IMPLANT BONE CHANGE

  • Lee Mi-Ran;Cho Lee-Ra;Yi Yang-Jin;Choi Hang-Moon;Park Chan-Jin
    • 대한치과보철학회지
    • /
    • 제43권6호
    • /
    • pp.736-744
    • /
    • 2005
  • Statement of problem. Initial stability of implant is an important factor for predicting osseointegration. It requires a rapid, non-invasive, user-friendly technique to frequently assess the implant stability and the degree of osseointegration. Purpose. The aim of this study was to evaluate the correlation between the resonance frequency analysis (RFA) and the radiographic method for peri-implant bone change under in vitro conditions. Material and Method. Twenty implants of 3.75 mm in diameter(Neoplant, Neobiotech, Korea) were used. To simulate peri-implant bone change, 2 mm-deep $45^{\circ}$ range horizontal defect and 2 mm-deep $90^{\circ}$ range horizontal defect area were serially prepared perpendicular to the X-ray beam after conventional implant insertion. Customized film holding device was fabricated to standardize the projection geometry for serial radiographs of implants and direct digital image was obtained. ISQ values and gray values inside threads were measured before and after peri-implant bone defect preparation. Results. Within a limitation of this study, ISQ value of resonance frequency analysis was changed according to peri-implant bone change (p<0.05) and gray value of radiographic method was changed according to peri-implant bone change (p<0.05). There was no correlation between the ISQ value and the gray value for peri-implant bone change (p>0.05). But, in horizontal defect condition, relatively positive correlation were between ISQ and gray values(r=0.663). Conclusion. This results provided a possibility that peri-implant bone change may be evaluated by both RFA and radiographic method.

Mandibular reconstruction using customized three-dimensional titanium implant

  • Lee, Yun-Whan;You, Hi-Jin;Jung, Jae-A;Kim, Deok-Woo
    • 대한두개안면성형외과학회지
    • /
    • 제19권2호
    • /
    • pp.152-156
    • /
    • 2018
  • Mandibular defects lead to severe deformation and functional deficiency. Vascularized osteocutaneous tissue has been widely used to reconstruct the mandible. However, it is technically challenging to shape this type of grafts in such a manner that they resemble the configuration of the mandible. A 48-year-old female patient who underwent anterolateral thigh (ALT) flap coverage after a tongue cancer excision was diagnosed with a tumor recurrence during the follow-up. A wide excision mandibulectomy and mandibular reconstruction with an ALT flap and a titanium implant were performed. The prefabricated titanium implant was fixed to the condyle. Then, an ALT flap was harvested from the ipsilateral thigh and anastomosed. After confirming that the circulation of the flap was intact, the implant was fixed to the parasymphysis. On the radiograph taken after the surgery, the prosthesis was well positioned and overall facial shape was acceptable. There was no postoperative complication during the follow-up period, 1 year and 2 months. The prefabricated implant allows the restoration of facial symmetry without harvesting autologous bone and it is a safe and effective surgical option for mandibular reconstruction.

임플란트 보철물의 식편압입: 교합적 원인분석과 대처 (Food impaction related with trauma from occlusion)

  • 조리라
    • 대한치과의사협회지
    • /
    • 제52권8호
    • /
    • pp.491-505
    • /
    • 2014
  • Food impaction between the implant prostheses and adjacent teeth is the most frequently observed problem. It may be caused by the migration of the adjacent teeth. This symptom may be observed at the mesial aspect of implant prostheses especially, and related with the multiple contributing factors including teeth vitality and antagonist. Idal proximal contact with optimal strength and shape should be made for preventing the food impaction. Shape of customized abutment and prosthesis should have optimal emergence profile. Long duration from the extraction to the delivery of implant prostheses, the adjacent teeth and antagonist teeth may have possibility of occlusal interferences. Remained teeth mobility can induce the food impaction regardless of interproximal contact strength. Occlusal adjustment to remove occlusal interferences can be a method for enhancing the stability of interproximal contact.

Considerations for Invasive Dental Treatment in Disabled Patients

  • Eun-Jung Kwak
    • Journal of Korean Dental Science
    • /
    • 제16권1호
    • /
    • pp.1-8
    • /
    • 2023
  • Dental treatment for the disabled should be a customized that considers the characteristics and degree of cooperation of each disabled patient. There are additional considerations during implant treatment and tooth extraction in disabled patients. Since some brain lesion disorder or cardiac disease patients may be taking antiplatelet or anticoagulant medications, it is necessary to evaluate whether these medications should be discontinued before an invasive procedure. Precautions should be taken for patients with heart valve disease considering the risk of infective endocarditis, especially during invasive dental procedures. Moreover, disabled patients may have difficulty in following instructions and cautions. There are specific considerations for each stage of implant treatment in disabled patients. In the case of patients who are in the pre- or post-transplant state, it is necessary to assess their general condition and oral disease due to the risk of infection. Since disabled patients with various systemic diseases may visit the dental clinic, it is important to understand their characteristics and treatment process in order to flexibly adjust the dental treatment plan accordingly.

The evaluation of healing patterns in surgically created circumferential gap defects around dental implants according to implant surface, defect width and defect morphology

  • Im, Se-Ung;Hong, Ji-Youn;Chae, Gyung-Joon;Jung, Ui-Won;Kim, Chang-Sung;Lee, Yong-Keun;Cho, Kyoo-Sung;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • 제38권sup2호
    • /
    • pp.385-394
    • /
    • 2008
  • Purpose: The aim of this study was to evaluate the factors affecting healing patterns of surgically created circumferential gap defects around implants in dogs. Materials and Methods: In four mongrel dogs, all mandibular premolars were extracted. After 8 weeks of healing periods, implants were submerged. According to the surface treatment, turned surface was designated as a group A and rough surface as a group B. In each dog, surgical defects on the left side were made with a customized tapered step drill and on the right with a customized paralleled drill. Groups were also divided according to the width of the coronal gaps: 1.0mm, 1.5mm, or 2.0mm. The dogs were sacrificed following 8 weeks and the specimens were analyzed histologically and histomorphometrically. Results: During the postoperative period, healing was uneventful and implants were well-maintained. As the size of the coronal gap was increased, the amount of bone-to-implant contact was decreased. The bone healing was greater in rough surface implants compared to the turned ones. About the defect morphology, tapered shape showed much bone healing and direct bone to implant contact even in the smooth surface implants. Conclusion: Healing of the circumferential defect around dental implant is influenced by the implant surface, defect width and the morphology of the defect. When using rough surface implants, circumferential gap defects within 2 mm do not need any kinds of regenerative procedures and the healing appeared to be faster in the tapered defect morphology than the paralleled one.

디지털 복제로 만든 맞춤형 인공치로 제작한 임시의치와 임플란트 수술용 템플릿을 통한 임플란트 지지형 고정성 보철 수복 증례 (Rehabilitation with implant-supported fixed dental prostheses using digital duplication technique on customized artificial tooth, interim denture and implant surgical template: A case report)

  • 정대길;오경철;심준성;박지만
    • 대한치과보철학회지
    • /
    • 제57권4호
    • /
    • pp.397-404
    • /
    • 2019
  • 성공적인 임플란트 치료를 위해서는 식립부위의 골조직 및 연조직 상태(condition)도 중요하지만 식립 위치 또한 매우 중요하다. 잘못된 위치에 식립된 임플란트는 생물학적, 심미적, 기계적 문제점을 야기하게 된다. 올바른 위치에 임플란트를 식립하기 위해서는 최종 보철물을 고려해야 하며 이를 위해서는 진단 왁스업 과정이 필요하다. 발치 후 사용 할 임시 의치의 인공치를 진단 왁스업 형태대로 제작하면 구강내에서 진단 왁스업 형태를 평가해 볼 수 있으며, 잘 적응된 임시 의치를 복제해 제작한 임플란트 수술용 템플릿으로 계획된 위치에 임플란트를 식립하는 것이 가능하다. 본 증례에서는 진단 왁스업을 디지털 복제하여 의치용 인공치를 맞춤형으로 제작하였고, 이를 이용해 임시 의치를 제작하였다. 충분한 적응 기간을 거친 후 임시 의치를 복제하여 임플란트 수술용 템플릿을 제작한 다음, 이를 활용하여 계획된 위치에 임플란트를 식립하였다. 골유착을 위한 충분한 치유기간을 가진 다음 진단 왁스업 형태가 반영된 임플란트 지지형 고정성 보철물을 제작하였다. 최종 보철물 장착 후 6개월간의 경과 관찰 기간 동안 심미적, 기능적으로 만족할 만한 치료 결과를 보였기에 이를 보고하고자 한다.

Digital evaluation of axial displacement by implant-abutment connection type: An in vitro study

  • Kim, Sung-Jun;Son, KeunBaDa;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권5호
    • /
    • pp.388-394
    • /
    • 2018
  • PURPOSE. To measure axial displacement of different implant-abutment connection types and materials during screw tightening at the recommended torque by using a contact scanner for two-dimensional (2D) and three-dimensional (3D) analyses. MATERIALS AND METHODS. Twenty models of missing mandibular left second premolars were 3D-printed and implant fixtures were placed at the same position by using a surgical guide. External and internal fixtures were used. Three implant-abutment internal connection (INT) types and one implant-abutment external connection (EXT) type were prepared. Two of the INT types used titanium abutment and zirconia abutment; the other INT type was a customized abutment, fabricated by using a computer-controlled milling machine. The EXT type used titanium abutment. Screws were tightened at $10N{\cdot}cm$, simulating hand tightening, and then at the manufacturers' recommended torque ($30N{\cdot}cm$) 10 min later. Abutments and adjacent teeth were subsequently scanned with a contact scanner for 2D and 3D analyses using a 3D inspection software. RESULTS. Significant differences were observed in axial displacement according to the type of implant-abutment connection (P<.001). Vertical displacement of abutments was greater than overall displacement, and significant differences in vertical and overall displacement were observed among the four connection types (P<.05). CONCLUSION. Displacement according to connection type and material should be considered in choosing an implant abutment. When adjusting a prosthesis, tightening the screw at the manufacturers' recommended torque is advisable, rather than the level of hand tightening.

Computer guided implant surgery와 CAD/CAM을 활용한 전악 수복 증례 (Full mouth rehabilitation utilizing computer guided implant surgery and CAD/CAM)

  • 김성진;한중석;김성훈;윤형인;여인성
    • 대한치과보철학회지
    • /
    • 제57권1호
    • /
    • pp.57-65
    • /
    • 2019
  • Computer guided implant surgery와 computer-aided design/computer-aided manufacturing, computer guided implant surgery (CAD/CAM) 기술의 발전은 수복 기반 임플란트 치료의 완성도를 한층 더 높였으며, 3D printing을 통한 국소의치의 제작도 빈도가 늘고 있다. 본 증례는 디지털 치의학의 작업 흐름을 따라서 콘빔컴퓨터단층촬영을 통한 치료 계획 수립 및 수술용 스텐트의 제작과 그를 바탕으로 한 임플란트 식립을 하였으며, 맞춤 지대주와 보철물을 제작하였다. 그 후 전자 서베잉과 3D printing을 통한 국소의치 금속 구조물 및 최종적으로 지르코니아 온레이의 제작을 통해 전악 수복을 완성하여 기능과 심미적으로 만족스러운 결과를 얻을 수 있었다.

Assessing changes of peri-implant bone using digital subtraction radiography

  • Kwon Ji-Yung;Kim Yung-Soo;Kim Chang-Whe
    • 대한치과보철학회지
    • /
    • 제39권3호
    • /
    • pp.273-281
    • /
    • 2001
  • Digital subtraction radiography may be one of the most precise and noninvasive methods for assessing subtle density changes in peri-implant bone, providing additional diagnostic information on implant tissue integration in overall maintenance. The aims of this study were to evaluate density changes after first, second surgery of dental implant and to measure the amount of marginal bone loss 9 months after second surgery using digital subtraction radiography. Bone change around 30 screw-shaped implants in 16 patients were assessed on radiographs. 17 Branemark implants of 3.75mm in diameter(Nobel Biocare, Goteborg, Sweden), 2 Branemark implants of 5.0mm in diameter, 11 $Replace^{TM}$ implants of 4.3mm in diameter(Nobel Biocare, Goteborg, Sweden) were used. To standardize the projection geometry of serial radiographs of implants, customized bite block was fabricated using XCP film holder(Rinn Corporation, Elgin, IL.) with polyether impression material of Impregum(ESPE, Germany) and direct digital image was obtained. Qualitative and quantitative changes on radiographs were measured with Emago software(The Oral Diagnostic System, Amsterdam, Netherlands). The results were as follows: 1. The peri-implant bone density of 69.2% implants did not change and the peri-implant bone density of 30.8% implants decreased after 3 months following first surgery. 2. The crestal bone density of 53.9% implants decreased first 3 months after second surgery. The crestal bone density of 58.8% implants increased 9 months after second surgery. No density change was observed around the midportion of the implants after second surgery, 3. The amount of marginal bone loss between different kinds of implants showed no statistically significant differences (p>0.05). 4. More than 90% of total marginal bone loss recorded in a 9-month period occurred during the first 3 months.

  • PDF