Optimal Operation Model of Battery Energy Storage System(BESS) for High Voltage Customer (고압수용가용 전지전력저장시스템의 최적 운전모형 수립에 관한 연구)

  • Kim, Eung-Sang;Kim, Jae-Eon;Kim, Ji-Won
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1192-1194
    • /
    • 1998
  • This paper presents a optimal operation algorithm of 1MW class Battery Energy Storage System (BESS) which is constructed in EHWA electric corporation. Total electric charge of conventional '97 year and simulated '98 year are compared to verify the validity of the proposed algorithm. Simulation results have showed that the about \\32,000,000 reduction of electric charge for 1 year.

  • PDF

A Study on Power Quality Detection Method of Utility interconnected Distributed Generation (분산전원이 연계된 배전계통에서의 전압품질 검출에 관한 연구)

  • Lee, B.Y.;Kim, J.C.;Jung, S.B.
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.252-254
    • /
    • 2004
  • This paper studies power quality problem of utility interconnected distributed generation. Recently, electronic devices that are sensitive to power quality have been increasing. Both utility and customer are interested in power quality problem. Therefore, we studied an effect of utility power quality caused by distributed generation. We detect and analysis voltage sag which is one of power quality indicator. Also, we used Matlab to simulate power quality problem.

  • PDF

The Study for Mitigating Voltage Sags in Distribution System (배전계통에서의 전압저하 저감방법에 관한 연구)

  • 오용택;김진성
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.139-145
    • /
    • 2002
  • Recently, power-electronics equipments or machine that microprocessor is included and computers have been installed continuously in industrial process or region of electronics customer. So concern for power quality, especially sags has been increased. Because those equipments are very sensitive to sags. The sag is phenomenon that magnitude of load voltage temporarily decreases because of power system fault. If a certain equipment in industrial process have any trouble result from sag, it can cause utility to be charged for enormous economics loss. Therefore it need to analyze the characteristic of sag and then mitigation method for sags in distribution system in odor to increase reliability. This paper gives an overview of sags characteristic due to short circuit fault in distribution system and after a general discussion of the various forms mitigation, gives a sags mitigation method with concentrating on changing the distribution system like spot network, on-site generation.

  • PDF

Micro-Grid System Analysis (마이크로그리드 시스템 해석)

  • Son, Kwang-M.;Lee, Kye-B.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.280-282
    • /
    • 2005
  • Micro-source units having power ratings in thousands of watts can provide even higher reliability and fuel efficiency than the conventional large scale units. These units are also clustered with loads creating micro-grid services to customer sites such as office buildings, industrial parks and homes. Micro-sources adopt voltage source inverter to ensure the power quality of sensitive loads. This paper deals with the connection of micro-sources into the system grid. Modeling and simulation of the grid connected micro-sources at the power frequency range are investigated. Simulation results show that the micro-grid system with two micro-sources has good dynamic characteristics.

  • PDF

Real and Reactive Power Control of Battery Energy Storage System (전지전력저장시스템의 유효 및 무효전력제어)

  • Kim, Dae-Won;Choi, Joon-Ho;Jung, Sung-Kyo;Kim, Jae-Chul;Choi, Byoung-Su
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1189-1191
    • /
    • 1999
  • This paper deals with the real and reactive power control of BESS(Battery Energy H Storage System) interconnected to power system. The real and reactive power control of proposed customer side BESS are performed by controlling the amplitude and the phase of inverter output voltage via power flow equation. Also in order to control the amplitude and phase of output voltage of proposed BESS, single-pulse width control method is used. The BESS and controller is implemented and the active and reactive power control is simulated by using the PSCAD/EMTDC simulation program.

  • PDF

Development of the Ubiquitous-based Intelligent Digital Switchgear Panel for Home Automation (유비쿼터스 기반의 주택 자동화용 디지털 분전반 개발)

  • Ko, Yun-Seok;Kim, Ho-Yong;Yun, Seok-Yeul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.5
    • /
    • pp.741-747
    • /
    • 2008
  • This paper proposes a new concept of IDSP(Intelligent Digital Switchgear Panel) which can solve the problem of the safety, the reliability and the convenience to correspond to the requirement of the general electric customer or electric power company under the ubiquitous-based home automation environments. By analyzing their requirement functions, a 32-bit micro processor is adopted as main controller to support the designed functions efficiently. The DSP-based single phase power management device is utilized to collect the electric power information and the ethernet convertor to communicate through internet among the IDSPs and the remote computer system. In the proposed IDSP, the several functions are implemented such as the earth leakage level display and waveform transmission, the electric fee display, the voltage management, the load management and the load control function. Finally, the prototype of the IDSP is made experimently based on the designed results, and then the effectiveness is verified by testing its basic functions.

A study on the distribution system using Flexible Reliable Intelligent Electrical eNergy Delivery System (FRIENDS(Flexible Reliable Intelligent Electrical eNergy Delivery System)를 이용한 배전계통의 효율적인 운용방안 개발)

  • Kim, Yong-Ha;Lee, Hyeong-No;Jo, Jae-Han;No, Dae-Seok;Lee, Beom;Choi, Sang-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1059-1062
    • /
    • 1998
  • This paper which can simulate FRIENDS(Flexible Reliable Intelligent Electrical eNergy Delivery System) model of distribution electrical system presents a new algorithm. In the operation of FRIENDS model, dispersed energy storage(DES) systems have an important role. We can use the active and reactive power of DES to control customer's voltage. In this, the former means load levelling operation and the later means voltage control operation of DES. We focus our research on load levelling operation of DES. We develope an algorithm to get an optimal capacity and operation schedule of DES and then apply it to the FRIENDS model. The results show the effectiveness of the proposed method.

  • PDF

A Study on the Development of ADWHM(Advanced Digital Watt-Hour Meter) (차세대 디지털 적산전력계 개발에 대한 연구)

  • Ko, Yun-Seok;Yun, Sang-Moon;Seo, Seong-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.262-264
    • /
    • 2003
  • This paper develops an ADWHM(Advanced Digital Watt Hour Meter) based on RISK type'8bit micro-controller, which has voltage management data recording function, load management data recording function as well as the existing watt-hour data recording data function. It can enhance greatly the economics of the existing remote meter reading system. Also it can improve highly the quality of power supplied to the electric customer by minimizing the voltage management cost and by enhancing the efficiency of load management.

  • PDF

Case Study of Power Factor Correction Capacitors On Upseting Elevator (고압 커패시터 투입시 수용가측 엘리베이터 정지사례 분석)

  • Cho, Nam-Hun;Jun, Young-Jae;Park, Hea-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.33-35
    • /
    • 2003
  • Capacitor switching is essential for the economic operation, and proper voltage control of KOREA electric utility distribution system. Voltage transients produced by capacitor switching (around 2.0 per unit at substation and 2.5 or less per unit at customer site, and lasting less then 1ms) do not have the magnitude or duration to interfere with the operation of computers, but they do disrupt the operation of adjustable speed drivers. The result of our research, ASD manufacturers should team from the computer industry and design products that will operate satisfactory in the electrical envelopment in which they will be placed. In this case history, the inductors on the input to ADSs in order to prevent nuisance tripping from capacitor switching(and other causes within the apartment) proved to be an effective, low-cost solution.

  • PDF

Evaluation of Power Quality Cost Based on Value-Based Methodology and Development of Unified Index (가치산정법에 의한 전력품질비용 산정 및 단일화지수의 개발)

  • Lee, Buhm;Kim, Kyoung-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.7
    • /
    • pp.1293-1298
    • /
    • 2011
  • This paper presents an Unified Index which can evaluate a performance of a distribution system based on value-based methodology. Reliability cost and voltage sags cost are calculated for each load point using Reliability Sector Customer Damage Function(SCDF). Aging cost is calculated for each load point using Aging SCDF. Power loss cost and operation cost are calculated for the system. By summation of each cost of load point and system, power quality cost can be obtained. Finally, this paper developed an unified index which can show the performance of a distribution system. Presented method has been applied to a real system, the usefulness of the method has been verified.