Instantaneous Voltage Disturbance Generator for the Performance Test of Dynamic UPS (다이나믹 UPS의 성능시험을 위한 순시전압 변동 발생기)

  • Kim J.W.;Lee K.S.;Byeon W.Y.;Nho E.C.;Kim I.D.;Chun T.W.;Kim H.G.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1254-1256
    • /
    • 2004
  • This paper deals with a novel 3-phase power quality disturbance generator. The proposed generator can be applied to the performance that of custom power devices. Voltage sag, swell and outage are provided by the generator. The control scheme for the disturbance generation is simple, and hardware setup is cost effective, compared with conventional scheme. The operating principle of the generator is described and the usefulness verified through simulation with 10KVA power rating.

  • PDF

Probabilistic Method of Risk Assessment in Voltage Sag Mitigation Studies (순간전압강하 보상을 위한 확률론적 위험도 분석 연구)

  • Han, Jong-Hoon;Jang, Gil-Soo;Park, Chang-Hyun
    • Journal of IKEEE
    • /
    • v.14 no.3
    • /
    • pp.236-243
    • /
    • 2010
  • Power quality mitigation devices play an important role in lots of industrial segments. Although there were many devices available in the market, the selection of an appropriate device specially for voltage sags and interruptions mitigation has been a challenge in the utility and customer for several years. It usually depends on technical and economic characteristics of the device. Nevertheless, most mitigation method is selected by rule of thumb or empirical method. In this paper, the life cycle cost analysis for the probabilistic risk assesment of voltage sag mitigation method is performed using either the deterministic or probabilistic approach. The difference between a deterministic and a probabilistic cost analysis approach is illustrated with five different case studies. This paper not only provides a comparison of life cycle costing of various devices but it also indirectly shows the possible savings due to the mitigation of voltage sags in the form of a project balance chart.

On-Line Type Dynamic Voltage Restorer System by Improvement of EDLC's energy utilization ratio (EDLC의 Energy이용 향상에 의한 On-Line type Dynamic Voltage Restorer System)

  • Shon, Jin-Geun;Park, Jong-Chan;Seo, Il-Dong;Jeon, Hee-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1099-1101
    • /
    • 2007
  • In this paper, a study has been performed for development of dynamic voltage restorer(DVR) system using EDLC (Electric Double Layer Capacitor) to solve voltage sags which are considered the dominant disturbances affecting power quality. With the prolific use of semiconductor devices in electrical equipment, modern-day loads are becoming increasingly sensitive to the sags and the disturbances prove to be costly to industries. As a technology-driven custom power installation, the Dynamic Voltage Restorer (DVR) is recognized to be most effective equipment that can be used to counter the voltage sag problem. Hence, this paper proposes the high-performance optimal design of On-Line type DVR system which can efficiently compensate the instantaneous voltage sag and instantaneous interruption of the utility voltage source.

  • PDF

Low-Power IoT Microcontroller Code Memory Interface using Binary Code Inversion Technique Based on Hot-Spot Access Region Detection (핫스팟 접근영역 인식에 기반한 바이너리 코드 역전 기법을 사용한 저전력 IoT MCU 코드 메모리 인터페이스 구조 연구)

  • Park, Daejin
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.11 no.2
    • /
    • pp.97-105
    • /
    • 2016
  • Microcontrollers (MCUs) for endpoint smart sensor devices of internet-of-thing (IoT) are being implemented as system-on-chip (SoC) with on-chip instruction flash memory, in which user firmware is embedded. MCUs directly fetch binary code-based instructions through bit-line sense amplifier (S/A) integrated with on-chip flash memory. The S/A compares bit cell current with reference current to identify which data are programmed. The S/A in reading '0' (erased) cell data consumes a large sink current, which is greater than off-current for '1' (programmed) cell data. The main motivation of our approach is to reduce the number of accesses of erased cells by binary code level transformation. This paper proposes a built-in write/read path architecture using binary code inversion method based on hot-spot region detection of instruction code access to reduce sensing current in S/A. From the profiling result of instruction access patterns, hot-spot region of an original compiled binary code is conditionally inverted with the proposed bit-inversion techniques. The de-inversion hardware only consumes small logic current instead of analog sink current in S/A and it is integrated with the conventional S/A to restore original binary instructions. The proposed techniques are applied to the fully-custom designed MCU with ARM Cortex-M0$^{TM}$ using 0.18um Magnachip Flash-embedded CMOS process and the benefits in terms of power consumption reduction are evaluated for Dhrystone$^{TM}$ benchmark. The profiling environment of instruction code executions is implemented by extending commercial ARM KEIL$^{TM}$ MDK (MCU Development Kit) with our custom-designed access analyzer.

Voltage Sag-Swell Generator for Power Quality Disturbance of Dynamic UPS System (다이나믹 UPS 시스템의 전력품질 외란발생을 위한 전압 Sag-Swell 발생기)

  • Byeon W. Y.;Kim J. W.;Lee K. S.;Nho E. C.;Kim I. D.;Chun T. W.;Kim H. G.
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.102-107
    • /
    • 2005
  • This paper describes a new voltage sag-swell generator for the test of custom power devices such as UPS, DVR, DSTATCOM, SSTS, etc. Voltage sag, swell, outage, and unbalance generation mechanism and the operating principle are described for the proposed scheme. The usefulness of the scheme is proved through simulations and experiments. The proposed scheme has good features of simple structure, high reliability, wide range of sag and swell variation, and easy control. Especially, the scheme can provide a cost-effective implementation of a power quality disturbance generator. Therefore, it is expected that the scheme will contribute to the self implementation of the system with low cost in laboratory.

Voltage Sag and Swell Generator with Thyristor Controlled Reactor (TCR을 이용한 Voltage Sag와 Swell 발생장치에 대한 연구)

  • Park, T.B.;Kwon, G.H.;Chung, Y.H.;Lee, J.;Lim, G.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.25-27
    • /
    • 2002
  • This paper describes a new economical voltage sag and swell generator suitable to the evaluations of high power custom power devices such as DVR (Dynamic Voltage Restorer) and DSTATCOM (Distribution Static Compensator). This system was designed to generate the several power quality disturbances in MVA power ratings - voltage sag and swell, under voltage, over voltage and harmonic distortions. The basic idea for voltage sag and swell is to use the voltage drop across a reactor, while the voltage swell is to use the step-up transformer and the TCR(Thyristor Controlled Reactor). In this paper, two identical 3 phase TCRs and a step-up transformer with tap changer are used. Additional harmonic filters are added to reduce the voltage distortion when TCRs are operated. Simulation results are given for several cases of voltage sag and swell generations.

  • PDF

A Low-Energy Ultra-Wideband Internet-of-Things Radio System for Multi-Standard Smart-Home Energy Management

  • Khajenasiri, Iman;Zhu, Peng;Verhelst, Marian;Gielen, Georges
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.4 no.5
    • /
    • pp.354-365
    • /
    • 2015
  • This work presents an Internet of Things (IoT) system for home energy management based on a custom-designed Impulse Radio Ultra-Wideband (IR-UWB) transceiver that targets a generic and multi-standard control system. This control system enables the interoperability of heterogeneous devices: it integrates various sensor nodes based on ZigBee, EnOcean and UWB in the same middleware by utilizing an ad-hoc layer as an interface between the hardware and software. The paper presents as a first the design of the IR-UWB transceiver for a portable sensor node integrated with the middleware layer, and also describes the receiver connected to the control system. The custom-designed low-power transmitter on the sensor node is fabricated with 130 nm CMOS technology. It generates a signal with a 1.1 ns pulse width while consuming $39{\mu}W$ at 1 Mbps. The UWB sensor node with a temperature measurement capability consumes 5.31 mW, which is lower than the power level of state-of-the-art solutions for smart-home applications. The UWB hardware and software layers necessary to interface with the control system are verified in over-the-air measurements in an actual office environment. With the implementation of the presented sensor node and its integration in the energy management system, we demonstrate achievement of the broad flexibility demanded for IoT.

PLL for Unbalanced Three-Phase Utility Voltage using Positive Sequence Voltage Observer (정상분 전압 관측기를 이용한 불평형 3상 전원의 PLL)

  • Kim, Hyeong-Su;Choi, Jong-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.2
    • /
    • pp.145-151
    • /
    • 2008
  • This paper proposes the PLL method using positive sequence voltage which is estimated by full-order state observer to find an accurate phase angle under the condition of unbalanced utility voltage. The proposed method uses the full-order state observer instead of existing method(APF All Pass Filter) to find a positive sequence of a utility voltage and this proposed method improves transient response of an estimated phase angle when a three-phase utility voltage becomes unbalanced. To compare proposed method withexisting method, experiments have been done for a phase angle detection of utility voltage when a three-phase utility voltage becomes unbalanced. Their results show that transient state response of proposed method is improved.

A Novel Arbitrary Notches Generation Converter with Easy Control of Notch Width and Magnitude (노치폭과 크기 제어가 용이한 새로운 방식의 임의 노치 발생 컨버터)

  • Byeon Woo-Yeol;Oh Kyung-Hee;Nho Eui-Cheol;Kim In-Dong;Choi Nam-Sup;Joung Gyu-Bum
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.8
    • /
    • pp.1700-1704
    • /
    • 2004
  • In this paper a novel power converter for some notches generation in the point of common coupling is described. The magnitude, width, polarity, and position of the notches generated by the proposed scheme can be varied arbitrary with simple control. The scheme has good features of simple structure, high reliability, low cost, high efficiency, and the capability of arbitrary several notches generation. The converter can be used for the test of custom power devices such as UPS, DVR, active power filter, etc. The circuit operation is described and the usefulness of the scheme is verified through simulations.

Sag-Swell Generator for the test of 3-phase Dynamic UPS (3상 다이나믹 UPS의 성능 시험을 위한 Sag-Swell 발생기)

  • Kim, J.W.;Lee, K.S.;Byun, W.Y.;Nho, E.C.;Kim, I.D.;Chun, T.W.;Kim, H.G.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.514-517
    • /
    • 2004
  • This paper describes a new 3 phase Sag-Swell generator for the test of custom power devices such as UPS, DVR, DSTATCOM, SSTS, etc. The proposed scheme has good features of simple structure, high reliability wide range of sag and swell variation, It can also generate voltage outage. The control scheme for the generation is simple. The operation principle of the proposed scheme is described and verified through simulations.