• Title/Summary/Keyword: Custom abutment

Search Result 36, Processing Time 0.032 seconds

THE EFFECT OF INTERNAL IMPLANT-ABUTMENT CONNECTION AND DIAMETER ON SCREW LOOSENING

  • Ha, Chun-Yeo;Kim, Chang-Whe;Lim, Young-Jun;Jang, Kyung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.3
    • /
    • pp.379-392
    • /
    • 2005
  • Statement of problem. One of the common problems of dental implant prosthesis is the loosening of the screw that connects each component, and this problem is more common in single implant-supported prostheses with external connection, and in molars. Purpose. The purposes of this study were: (1) to compare the initial abutment screw detorque values of the six different implant-abutment interface designs, (2) to compare the detorque values of the six different implant-abutment interface designs after cyclic loading, (3) to compare the detorque values of regular and wide diameter implants and (4) to compare the initial detorque values with the detorque values after cyclic loading. Material and methods. Six different implant-abutment connection systems were used. The cement retained abutment and titanium screw of each system were assembled and tightened to 32Ncm with digital torque gauge. After 10 minutes, initial detorque values were measured. The custom titanium crown were cemented temporarily and a cyclic sine curve load(20 to 320N, 14Hz) was applied. The detorque values were measured after cyclic loading of one million times by loading machine. One-way ANOVA test, scheffe’s test and Mann-Whitney U test were used. Results. The results were as follows : 1. The initial detorque values of six different implant-abutment connections were not significantly different(p>0.05). 2. The detorque values after one million dynamic cyclic loading were significantly different (p<0.05). 3. The SS-II regular and wide implant both recorded the higher detorque values than other groups after cyclic loading(p<0.05). 4. Of the wide implants, the initial detorque values of Avana Self Tapping Implant, MIS and Tapered Screw Vent, and the detorque values of MIS implant after cyclic loading were higher than their regular counterparts(p<0.05). 5. After cyclic loading, SS-II regular and wide implants showed higher detorque values than before(p<0.05).

Influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with a lingual slot

  • Choi, Kyu-Hyung;Son, KeunBaDa;Lee, Du-Hyeong;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.5
    • /
    • pp.381-387
    • /
    • 2018
  • PURPOSE. Cement-retained implant prostheses can lack proper retrievability during repair, and residual cement can cause peri-implantitis. The purpose of this in vitro study was to evaluate the influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with lingual slots, known as retrievable cement-type slots (RCS). MATERIALS AND METHODS. We fabricated six types of titanium abutments (10 of each type) with two different heights (4 mm and 6 mm), three different convergence angles ($8^{\circ}$, $10^{\circ}$, and $12^{\circ}$), a sloped shoulder margin (0.6 mm depth), a rectangular shape ($6mm{\times}6.5mm$) with rounded edges, and a rectangular ledge ($2mm{\times}1mm$) for the RCS. One monolithic zirconia crown was fabricated for each abutment using a dental computer-aided design/computer-aided manufacturing system. The abutments and crowns were permanently cemented together with dual-curing resin cement, followed by 24 hours in demineralized water at room temperature. Using a custom-made device with a slot driver and torque gauge, we recorded the torque ($N{\cdot}cm$) required to remove the crowns. Statistical analysis was conducted using multiple regression analysis and Mann-Whitney U tests (${\alpha}=.05$). RESULTS. Removal torques significantly decreased as convergence angles increased. Multiple regression analysis showed no significant interaction between the abutment height and the convergence angle (Durbin-Watson ratio: 2.186). CONCLUSION. Within the limitations of this in vitro study, we suggest that the retrievability of cement-retained implant prostheses with RCS can be maintained by adjusting the abutment height and convergence angle, even when they are permanently cemented together.

A technique for fabricating abutment replica with hot melt adhesive material to minimize residual cement in implant restoration: a case report (임플란트 보철 합착 시 잔여 시멘트 최소화를 위해 열가소성 접착제를 이용한 복제 지대주 제작 방법: 증례보고)

  • Seo, Chi-Won;Han, A-Reum;Seo, Jae-Min;Lee, Jung-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.240-245
    • /
    • 2016
  • Removal of excess cement is important to prevent biological complication in cementation of implant restoration with subgingival margin. It can be difficult to completely remove excess cement. Several techniques have been introduced to minimize excess cement using abutment replica. In this case report, a simple method for making abutment replica with hot melt adhesive material in dental office was described. This technique is simple and effective because it can be used for pre-fabricated or custom abutment without additional laboratory procedure. In addition, it can minimize excess cement after cementation of implant restoration.

A literature review on implant abutment and soft tissue response (임플란트 지대주와 임플란트 주위 연조직의 반응에 관한 고찰)

  • Lee, Young-Hoon;Ko, Kyung-Ho;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.4
    • /
    • pp.263-273
    • /
    • 2016
  • In the implant prosthetic procedure, the soft tissue reaction was varied with the material and surface treatment of the abutment. It may be the cause of the peri-implantitis, and hence it can affect the long-term prognosis of the implant prosthesis. Titania and zirconia abutment presented superior biocompatibility and stable soft tissue reaction, while gold alloy abutment showed unfavorable reaction sometimes. A soft tissue reaction can be differed by the surface characteristics even in the same material type. Because rougher surface induces a bacterial attachment, the part contacting a soft tissue should have smooth surface. Additional surface treatment can enhance the cellular response without increasing bacterial attachment. Repeated removal and insertion of the abutment and the shape of the abutment may affect the soft tissue reaction, also. Ultrasonic cleaning and argon plasma cleaning are effective way to clean the retained micro-dust on the customized abutment.

Evaluating usability of and satisfaction with two types of dental CAD software (두 종류 치과 임플란트 캐드 소프트웨어의 사용자 편의성 및 만족도 비교)

  • Kim, Seong-Min;Lee, Wan-Sun;Son, Keunbada;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.1
    • /
    • pp.11-19
    • /
    • 2019
  • Purpose: This study evaluated the usability of and satisfaction with two types of computer-aided design (CAD) software among users who had experience with dental implant CAD software and those who did not. Materials and Methods: Dental technicians (n = 20) who had previous experience with dental implant CAD Software and students from the College of Dentistry (n = 12) who had never designed implant custom abutments were asked to evaluate two types of CAD Software, Exocad and Deltanine. In addition, the participants were asked to fill out a structured questionnaire (Section 1: Entering basic information and retrieving files; Section 2: Setting conditions before abutment design; Section 3: Setting abutment design; and Section 4: Overall satisfaction). For the statistical analysis of the collected data, Mann-Whitney U test was used (${\alpha}=.05$). Results: The ease of design and satisfaction with the implant CAD Software, evaluated with respect to 21 statements divided into four Stages, were significantly higher for Exocad in both groups for Secion 1. For Sections 2 and 3, participants with experience evaluated Deltanine to be significantly better. For Section 4, both groups evaluated Exocad Software to be better. Conclusion: Overall, the Exocad Software was evaluated as having better usability and offering greater satisfaction. However, in terms of performance in the core of the design process, i.e. Sections 2 and 3, Deltanine was rated higher by the experienced users. Thus, if the user interface design parts are supplemented, Deltanine CAD Software could be put to a wider use in clinics.

An efficient way of communication between dentists and dental technicians to ensure optimum clinical outcome with implant restorations (임플란트 보철물 제작시 치과의사와 기공사가 효과적으로 소통하는 한가지 방법)

  • Kim, Chonghwa
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.29 no.2
    • /
    • pp.66-74
    • /
    • 2020
  • Communication and cooperation between dentists and dental technicians are two essential elements for the fabrication of high quality 'custom' prosthesis. For successful communication and cooperation between the two groups, however, dentists and dental technicians must share common understanding about clinical dentistry. Ironically, it is often noticed that they are not really sharing the same clinical knowledge. Although there is a strong association between 'Emergence Profile' of implant prostheses and periodontal health or esthetics, no definite guideline has ever been provided for ideal emergence profile of implant prosthesis in literature. Problems resulted from inherent differences between implants and natural teeth must be acknowledged and shared between dentists and dental technicians so that they can come up with desirable clinical results with implant prostheses.

The Accuracy of Master Cast for Implant Prosthesis According to the Types of Impression Tray and Splinting Methods of Impression Copings (인상용 트레이의 종류와 인상용 코핑의 연결고정이 임플랜트 주모형의 정확성에 미치는 영향)

  • Lee, Jee-Hyuk;Choi, Yu-Sung;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.4
    • /
    • pp.433-445
    • /
    • 2010
  • The aim of this study was to evaluate the fixation effect by connecting impression copings and to compare the three types of impression trays which were used in open tray impression technique. Experimental groups used 3 types of impression trays which are custom tray, plastic metal combination tray and polycarbonate stock tray. These three groups were subdivided into splinted and non-splinted impression copings group. The total number of experimental groups was six. 10 specimens were made for each group. We used 1-screw test, observing the specimen on which only one side abutment of reference framework was fixated with 20 Ncm. The gap between implant analogue and abutment of the other side was observed by stereo microscope. It was measured at 6 points in each specimen. Measuring value was selected when same result was revealed 3 times. Recorded data were statistically analyzed. Whether impression copings were splinted or not, there was no significant difference among custom tray group, plastic metal combination tray group, and polycarbonate stock tray group. Significant statistical difference in vertical fit discrepancy was found between splinted and non-splinted impression copings group with custom tray, plastic metal combination tray and polycarbonate stock tray (p<0.05).

Customized abutment and screw-type implant prostheses after cementation based on the digital intra-oral impression technique (구강 내 디지털 인상채득을 통한 맞춤형 지대주와 시멘트 합착 후 나사형 임플란트 보철 수복 증례)

  • Hong, Yong-Shin;Park, Eun-Jin;Kim, Sun-Jong;Kim, Myung-Rae;Heo, Seong-Joo;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.1
    • /
    • pp.67-73
    • /
    • 2012
  • Fixed dental prostheses such as inlay, onlay, crown, and bridge fabricated by CAD/CAM technique combined with digital impressions is getting popular due to the recent rapid progress of digital impression taking system. For the scope of implant prosthesis, however, digital intra-oral scan hasn't been actively utilized for the fabrication of superstructures. In this case report, 6 cases of titanium-milled custom abutment based on the iTero intra-oral scan data were introduced, five of them were restored with screw-type prosthesis after cementation (SCRP) and the clinical results were satisfactory on restoring the function and esthetics.

Full mouth rehabilitation with fixed implant-supported prosthesis using temporary denture and double digital scanning technique: a case report (임시 의치와 이중 디지털 스캐닝 기법을 활용한 전악 고정성 임플란트 수복 증례)

  • Seok-Hyun Shin;Chan-Ik Park;Se-Ha Kang;Ji-Eun Moon;Min-Seok Oh;Chul-Min Park;Woo-Jin Jeon;Seong-Gu Han;Sun-Jae Kim;Su-Jin Choi
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.245-256
    • /
    • 2023
  • When restoring with a dental digital system for implant-supported prosthesis, a double digital scanning technique is required: an intraoral scan of the three-dimensional implant location and intraoral scan after placement of temporary denture or provisional prosthesis. During the intraoral scan, the use of scan body as a stable landmark can improve the accuracy of digital impression and simplify laboratory process. In this case, a full-digital system was used to plan and fabricate a custom abutment, provisional prosthesis, and definitive prosthesis. After implant placement, the scan area of the intraoral scan body connected with implant and the intraoral scan body marked on the inside of temporary denture were superimposed. Out of the superimposed files, a custom abutment and provisional prosthesis were fabricated which match the vertical dimension of temporary denture, and definitive prosthesis was fabricated based on provisional prosthesis. We report this case because result has been functionally and esthetically satisfactory by using vertical dimension and central relation set during the fabrication of temporary denture to the definitive prosthesis.

Radiographic evaluation of marginal bone level alteration around narrow implants placed in narrow alveolar ridge using guided flapless surgery (폭이 좁은 치조골에서 컴퓨터가이드를 이용한 무절개 임플란트 수술로 식립한 narrow implant의 방사선학적 평가)

  • Jeong, Seung-Mi;Choi, Byung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.4
    • /
    • pp.306-312
    • /
    • 2020
  • Purpose: The aim of this study was to compare radiographic outcomes around narrow-diameter implants placed using guided flapless surgery at longer than 6 month post-placement. Materials and methods: A total of 12 implants were assessed in 12 patients for the sites where 0.5 - 1.5 mm labial bone was covering the implants, using CBCT. Results: A statistically significant preservation of crestal bone was observed in the narrow-diameter implants. Conclusion: Guided flapless implant surgery may be important in preventing bone loss around the narrow-diameter implants that are placed in narrow alveolar ridges.