A study on the transient cooling process of a vertical-high temperature tube in an annular flow channel (환상유로에 있어서 수직고온관의 과도적 냉각과정에 관한 연구)

  • 정대인;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.156-164
    • /
    • 1986
  • In the case of boiling on high temperature wall, vapor film covers fully or parcially the surface. This phenomenon, film boiling or transition boiling, is very important in the surface heat treatment of metal, design of cryogenic heat exchanger and emergency cooling of nuclear reactor. Mainly supposed hydraulic-thermal accidents in nuclear reactor are LCCA (Loss of Coolant Accident) and PCM (Power-Cooling Mismatch). Recently, world-wide studies on reflooding of high temperature rod bundles after the occurrence of the above accidents focus attention on wall temperature history and required time in transient cooling process, wall superheat at rewet point, heat flux-wall superheat relationship beyond the transition boiling region, and two-phase flow state near the surface. It is considered that the further systematical study in this field will be in need in spite of the previous results in ref. (2), (3), (4). The paper is the study about the fast transient cooling process following the wall temperature excursion under the CHF (Critical Heat Flux) condition in a forced convective subcooled boiling system. The test section is a vertically arranged concentric annulus of 800 mm long and 10 mm hydraulic diameter. The inner tube, SUS 304 of 400 mm long, 8 mm I.D, and 7 mm O.D., is heated uniformly by the low voltage AC power. The wall temperature measurements were performed at the axial distance from the inlet of the heating tube, z=390 mm. 6 chromel- alumel thermocouples of 76 .mu.m were press fitted to the inner surface of the heating tube periphery. To investigate the heat transfer characteristics during the fast transient cooling process, the outer surface (fluid side) temperature and the surface heat flux are computed from the measured inner surface temperature history by means of a numerical method for inverse problems of transient heat conduction. Present cooling (boiling) curve is sufficiently compared with the previous results.

  • PDF

Verification of Periodical Calibration for Iso-center Positions using Quality Assurance System for Irradiation Equipment Position Established at PMRC

  • Yasuoka, Kiyoshi;Ishikawa, Satoko
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.192-194
    • /
    • 2002
  • We present the results on the calibration of iso-center positions using the quality assurance system established at PMRC for determination of center position in X-ray and proton irradiation fields. Details on the system are presented in another presentation in this session. The equipment in the system is mounted on a patient treatment bed in each proton exposure room, G1 or G2. A center of a stainless ball on the equipment is set at a cross of laser markers located around the iso-center and fixed on the room and on the snout in the gantry. A proton beam or an X-ray beam is exposed onto the ball through a brass collimator of 100 mm ${\times}$ 100 mm and projected onto the imaging plate set at I cm behind the ball. On the axis perpendicular to the thrust axis of the gantry on the imaging plate, a distance between a center of the collimator image and a center of the ball image varies as a cosine function of gantry angles unless the ball is set on the iso-center. An amplitude of the cosine curve shows the distance between the ball and the iso-center, an offset the offset of the collimator, and a phase shift at a zero crossing point the ball direction viewed from the iso-center. We present the relation among the iso-center position, the laser maker position, and the center of proton and X-ray irradiation fields. Its stability and its reproducibility are discussed.

  • PDF

The Performance Evaluation of Parallel and Single Structure MCMA-MDD Adaptive Equalizer for 16-QAM Signal (16-QAM 신호에대한 병렬 구조와 단일 구조를 갖는 MCMA-MDD 적응 등화기의 성능 평가)

  • Lim, Seung-Gag
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.4
    • /
    • pp.15-22
    • /
    • 2012
  • This paper deals with the performance comparison and evaluation of blind adaptive equalizer, the PMCMA-MDD and DW-MCMA, that is used for compensation of the amplitude and phase distortion which occurs in the time dispersive channel. Basically, these algorithms are modification of MCMA cost function in order to obtain the fast convergence speed and reduced residual isi by taking the parallel and serial double structured and the combination of the concept of RCA for the updating the tap coefficient. We implements the algorithm of it and compare the recovered constellation, residual isi, MSE characteristics curve and SER in the signal to noise ratio given the time dispersive channel. As a result of simulation, the PMCMA-MDD has a good in recovered constellation than DW-MCMA. But in the SER, the DW-MCMA has a good than PMCMA-MDD.

Performance Improvement of MCMA Equalization Algorithm Using Adaptive Modulus (Adaptive Modulus를 이용한 MCMA 등화 알고리즘의 성능 개선)

  • Lim, Seung-Gag
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.3
    • /
    • pp.57-62
    • /
    • 2014
  • This paper proposes the improving the equalization performance using the adaptive modulus concept to the MCMA blind equalizer in order to the reduction of intersymbol interference which occurs in the band limited and time dispersive communication channel. In MCMA blind algorithm, it is possible to reducing the amplitude and phase rotation of intersymbol interference without training sequence, the fixed constant modulus of transmission signal is used. But in proposed algorithm, the modulus are adaptively varies according to the equalizer output signal, then the improved equalization performance were obtained by the computer simulation. For this, the recovered signal constellation that is the output of the equalizer, the convergence performance by MSE, MD (maximum distortion) and residual isi characteristic learning curve were used. The propose algorithm has fairly good performance compared to the traditional MCMA algorithm in the same adaptive equalization algorithm.

Interlayer and Interfacial Exchange Coupling of IrMn Based MTJ

  • Wrona, J.;Stobiecki, T.;Czapkiewicz, M.;Kanak, J.;Rak, R.;Tsunoda, M.;Takahashi, M.
    • Journal of Magnetics
    • /
    • v.9 no.2
    • /
    • pp.52-59
    • /
    • 2004
  • As deposited and annealed MTJs with the structure of $Ta(5 nm)/Cu(10 nm)/Ta(5 nm)/Ni_{80}Fe_{20}(2 nm)/Cu(5 nm)/ Ir_{25}Mn_{75}(10 nm)/Co_{70}Fe_{30}(2.5 nm)/Al-O/Co_{70}Fe_{30}(2.5nm)/Ni_{80}Fe_{20}(t)/Ta(5nm)/Ni_{80}Fe_{20}(t)/Ta(5 nm)$, where t=10, 30, 60 and 100 nm were characterized by XRD and magnetic hysteresis loops measurements. The XRD measurements were done in grazing incidence $(GID scan-2{\theta})$ and ${\theta}-2{\theta}$ geometry, by rocking curve $(scan-{\omega})$ and pole figures in order to establish correlation between texture and crystallites size and magnetic parameters of exchange biased and interlayer coupling. The variations of shifting and coercivity field of free and pinned layers after annealing in $300^{\circ}C$ correlate with the improvement of [111] texture and grains size of $Ni_{80}Fe_{20}$ and $Ir_{25}Mn_{75}$ respectively. The exchange biased and the coercivity fields of the pinned layer linearly increased with increasing grain size of $Ir_{25}Mn_{75}$, The reciprocal proportionality between interlayer coupling and coercivity fields of the free layer and grain size of $Ni_{80}Fe_{20}$ was found. The enhancement of interlayer coupling between pinned and free layers, after annealing treatment, indicates on the correlated in-phase roughness of dipolar interacting interfaces due to increase of crystallites size of $Ni_{80}Fe_{20}$.

Pre-screening technique for MT and GDS data processing based on the spectral power of Electromagnetic field (전자기장의 분광 에너지에 기반한 MT 및 GDS 자료의 전처리 기법 연구)

  • Yang, Jun-Mo;Kwon, Byung-Doo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.253-258
    • /
    • 2006
  • The Korean peninsula has been known to be very difficult to acquire clean MT and GDS data due to its highly industrialization and civilization. In this environment, a pre-screening step selecting data segments with a proper S/N ration is an essential one. This study modified the automatic pre-screening step based on the spectral power of electromagnetic field (RMP) taking account of the situation of the Korean Peninsula. The modified RMP technique was applied to MT data measured at seven sites located in middle part of the peninsula. In the whole sense, the RMP technique considerably improved the connectivity of apparent resistivity and phase curves around the period of 10 sec. In addition, the results processed by the RMP technique showed a very little difference with those derived from manual editing, and the superior performance of it is found especially in the connectivity of apparent resistivity curve.

  • PDF

A Study of the Guided Wave Propagation in the Water Supplying Pipes with Scale (스케일이 있는 급수관내의 유도초음파의 전파 특성에 관한 연구)

  • Song, Sung-Jin;Lee, Dong-Hoon;Lee, Hyun-Dong;Bae, Cheol-Ho;Park, Jung-Hoon;Kim, Young-H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.1
    • /
    • pp.1-6
    • /
    • 2003
  • Since the scale in pipes reduces the flow rate, a quantitative evaluation of the scale is essential for the proper maintenance of pipes. Guided waves were employed to estimate the amount of scale in water supplying pipes. Using variable angle wedge, several modes of guided waves wire generated and their propagation charcteristics along the pipes with stale were analyzed. It was experimentally observed that the amplitude of F(M,2) modes at $f{\times}d=1.5MHz\;mm$ decreased significantly with increasing amount of scale. The present study showed that F(M,2) modes were optima) to evaluate the scale in water supplying pipes.

Fluorogenic and Chromogenic Assay for Rapid Detection of Escherichia coli and Total Coliform Bacteria (효소발색법을 이용한 대장균 및 총대장균군 신속 검사)

  • Lee, Keun-Heon;Kim, Hun-Soo;Kim, Byong-Ryol;Lee, Seung-Hui;In, Chi-Kyung;Park, Kyeong-Ryang
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.3
    • /
    • pp.363-369
    • /
    • 2009
  • We developed the Eco medium for Escherichia coli and total coliforms, which was modified by Violet Red Bile (VRB) medium, and derived the standard curve of exponential phase at $OD_{410}$ by using type strains such as E. coli ATCC11303, Enterobacter cloacae KCTC2361, Klebsiella pneumoniae KCTC2241, and Citrobacter freundii KCTC2359. Also, we used total 93 samples of spring and stream water to compare the detection ability of total coliforms between the method using Eco medium and such as most probable number (MPN), and plate count methods. As a result, the qualitative analysis of E. coli and total coliforms using Eco medium contained ortho-nitrophenyl-$\beta$-galactoside (ONPG) and 4-methylumbelliferyl-$\beta$-D-glucuronide (MUG) was same as those of Korean standard methods (Colilert kit). And the colony forming unit (CFU) detected in Eco medium was similar to those of result from MPN and plate count methods. Moreover, the agreement, sensitivity, and specificity of the developed kit was more than 97.5% in comparison with Colilert kit for 350 samples. Thus, the Eco medium can be used both qualitative and quantitative analysis of E. coli and total coliforms.

Characteristics of the Algal Growth inhibition Substances Produced by Alteromonas sp. SR-14 (Alteromonas sp. SR-14가 생산하는 조류증식 저해 물질의 특성)

  • 김지회;이희정;이태식;김형락;이명숙;장독석
    • Journal of Food Hygiene and Safety
    • /
    • v.14 no.3
    • /
    • pp.270-276
    • /
    • 1999
  • In previous reports, the authors isolated the algicidal marine bacterium, Alteromonas sp. SR-14 and demonstrated its growth inhibition of diatom, Chaetoceros calcitrans (C. calcitrans). In this paper, we studied the effects of cell free culture filtrate of Alteromonas sp. SR-14 on the growth of C. calcitrans, and the characteristics of the algal growth inhibition substance. The culture filtrate of Alteromonas sp. SR-14 grown in peptone broth showed growth inhibition activity against C. calcitrans. The reasonable culture conditions of the bacterium for producing of algal growth inhibition substances were $15~20^{\circ}$ in temperature, 7.0-9.0 in pH and $23~30{\textperthousand}$ in salinity, respectively. The algal growth inhibition activity of culture filtrate was increased from stationary phase in growth curve of Alteromonas sp. SR-14. The molecular weights of algal growth inhibition substances produced by Alteromonas sp. SR-14 were ranged about from 3 KDa to 12 KDa. Among the substances, less than 10 KDa fraction were stable by heating at $100^{\circ}$ for 10 minutes, while more than 10 KDa fraction were heat labile. According to the experimental results, the algal growth inhibition substance produced by the bacterium was not a single compound.

  • PDF

Determination of Ethyl Carbamate in Maesil Extract and Estimated Daily Intake (매실농축액의 에틸카바메이트 분석과 노출량 평가)

  • Choi, Bogyoung;Koh, Eunmi
    • Korean journal of food and cookery science
    • /
    • v.31 no.2
    • /
    • pp.112-117
    • /
    • 2015
  • The analytical method for ethyl carbamate (EC) in maesil (Prunus mume) extract was developed with deuterium-labeled ethyl carbamate as an internal standard. Samples were neutralized with an addition of 1 N sodium hydroxide solution, followed by a solid phase extraction with a Chem Elut cartridge. A standard curve exhibited a good linearity with correlation coefficient of 0.9991. The limit of detection (LOD) and limit of quantification (LOQ) were 2.91 ng/g and 8.83 ng/g, respectively. The recovery rate of EC ranged from 91.40% to 120.90%. The precision never exceeded 12.57% (intra-day) and 11.03% (inter-day). Samples were comprised of 24 home-made and 7 commercially-available maesil extracts. Eight home-made samples contained EC at levels between 3.39 and 75.76 ng/g. Three commercially-available samples had EC at levels between 11.67 and 20.16 ng/g. Average daily intakes of EC from maesil extracts for consumers were 0.23 g/kg of body weight. Based on a benchmark dose confidence limit ($BMDL_{10}$) of 0.25 mg/kg of body weight/day, the margin of exposure (MOE) of EC in maesil extract for consumers was 94,150, which is not of concern. Considering that a daily intake of maesil extract has been increasing, further studies on the formation of EC in maesil extract is needed.