• Title/Summary/Keyword: Curve phase

Search Result 780, Processing Time 0.027 seconds

Study on Confirmation of Solid-Meal Lag Phase of Gastric Emptying (고형음식물 위배출시 초기 정체기의 존재에 대한 연구)

  • Lee, Ji-Young;Lee, Kyoung-Soo;Kim, Chang-Guhn;Juhng, Seon-Kwan;Won, Jong-Jin;Nah, Yong-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.207-210
    • /
    • 1991
  • The purpose of this study was to examine the existence of a lag phase of gastric emptying of solid meals. We studied solid phase gastric emptying in 26 normal subject using continuous data aquisition for 30 minutes. Each ingested a 300 g meal containing $^{99m}Tc-labeled$ scrambled egg (solid 150g, milk 150 ml). Lag phase was determined by 1) inspection of the gastric emptying curve 2) time to a 2% decrease in stomach activity 3) the time of visual appearance of duodenal activity on computer image We concluded that solid meal lag phase exist.

  • PDF

A Study on the Near Wake of a Square Cylinder Using Particle Image Velocimetry (III) - Phase Average - (PIV기법을 이용한정사각실린더의 근접후류에 관한 연구 (III) - 위상평균유동장 -)

  • Lee, Man-Bok;Kim, Gyeong-Cheon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.11
    • /
    • pp.1527-1534
    • /
    • 2001
  • Phase averaged velocity fields in the near wake region behind a square cylinder have been (successfully) obtained using randomly sampled PIV data sets. The Reynolds number based on the flow velocity and the vertex height was 3,900. To identify the phase information, we examined the magnitude of circulation and the center of peak vorticity. The center of vorticity was estimated from lowpass filtered vorticity contours (LES decomposition) adopting a sub-pixel searching algirithm. Due to the sinusoidal nature of firculation which is closely related to the instantaneous vorticity, the location of peak voticity fits well with a sine curve of the circulation magnitude. Conditionally-averaged velocity fields represent the barman vortex shedding phenomenon very well within 5 degrees phase uncertainty. The oscillating nature of the separated shear layer and the separation bubble at the top surface are clearly observed. With the hot-wire measurements of Strouhal frequency, we found thats the convection velocity changes its magnitude very rapidly from 25 to 75 percent of the free stream velocity along the streamwise direction when the flow passes by the recirculation region.

A study on the determination of Ultrasonic Travel Time by Norm Phase-Time Method (위상시간법에 의한 초음파전파시간의 결정에 관한 연구)

  • 이은방
    • Journal of the Korean Institute of Navigation
    • /
    • v.18 no.4
    • /
    • pp.137-146
    • /
    • 1994
  • In this paper, a new algorithm to measure the ultrasonic travel time is proposed, which is fundamental to estimate distance depth and volume in several media. Pulse wave has been used to measure travel time of transmitted signal. However, due to the characteristic of transducer and propagation, the received signal is so distorted that it is difficult to measure travel time, which is propagation, the received signal is so distorted that it is difficult to measure travel time, which is to be time difference between transmitted and received signals. In this proposed method, transmitted and received signal are transformed respectively into norm phase newly designed by this paper and displayed on phase-time curve. And travel time is simply determined by the arithmetic numerical mean of time difference at the identical norm phase on the phase-time curves of transmitted and received signals. This method has several features; firstly, travel time is calculated analytically with high accuracy by least square error method, secondly, it is useful to compare the difference of signal magnitude for time information, thirdly, noise and discrete errors are relatively small, finally, the measurement accuracy is not influenced by D.C. bias. In particular, this method is useful and applicable to measuring very short distance and sound speed with high accuracy.

  • PDF

Concrete-steel bond-slip behavior of recycled concrete: Experimental investigation

  • Ren, Rui;Qi, Liangjie;Xue, Jianyang;Zhang, Xin;Ma, Hui;Liu, Xiguang;Ozbakkaloglu, Togay
    • Steel and Composite Structures
    • /
    • v.38 no.3
    • /
    • pp.241-255
    • /
    • 2021
  • In order to study the interfacial bond-slip behavior of steel reinforced recycled concrete (SRRC) under cyclic loading, thirteen specimens were designed and tested under cyclic loading and one under monotonic loading. The test results indicated that the average bond strength of SRRC decreased with the increasing replacement ratio of recycled concrete, whereas the bond strength increased with an increase in the concrete cover thickness, the volumetric stirrup ratio, and the strength of recycled concrete. The ultimate bond strength of the cyclically-loaded specimen was significantly (41%) lower than that of the companion monotonically-loaded specimen. The cyclic phenomena also showed that SRRC specimens went through the nonslip phase, initial slip phase, failure phase, bond strength degradation phase and residual phase, with all specimens exhibiting basically the same shape of the bond-slip curve. Additionally, the paper presents the equations that were developed to calculate the characteristic bond strength of SRRC, which were verified based on experimental results.

Outdoor Positioning Estimation of Multi-GPS / INS Integrated System by EKF / UPF Filter Conversion (EKF/UPF필터 변환을 통한 Multi-GPS/INS 융합 시스템의 실외 위치추정)

  • Choi, Seung-Hwan;Kim, Gi-Jeung;Kim, Yun-Ki;Lee, Jang-Myung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.12
    • /
    • pp.1284-1289
    • /
    • 2014
  • In this Paper, outdoor position estimation system was implemented using GPS (Global Positioning System) and INS (Inertial Navigation System). GPS position information has lots of errors by interference from obstacles and weather, the surrounding environment. To reduce these errors, multiple GPS system is used. Also, the Discrete Wavelet Transforms was applied to INS data for compensation of its error. In this paper, position estimation of the mobile robot in the straight line is conducted by EKF (Extended Kalman Filter). However, curve running position estimation is less accurate than straight line due to phase change in rotation. The curve is recognized through the rate of change in heading angle and the position estimation precision of the initial curve was improved by UPF (Unscented Particle Filter). In the case of UPF, if the number of particle is so many that big memory gets size is needed and processing speed becomes late. So, it only used the position estimation in the initial curve. Thereafter, the position of mobile robot in curve is estimated through switching from UPF to EKF again. Through the experiments, we verify the superiority of the system and make a conclusion.

Estimation of Growth Curves and Suitable Slaughter Weight of the Liangshan Pig

  • Luo, Jia;Lei, Huaigang;Shen, Linyuan;Yang, Runlin;Pu, Qiang;Zhu, Kangping;Li, Mingzhou;Tang, Guoqing;Li, Xuewei;Zhang, Shunhua;Zhu, Li
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.28 no.9
    • /
    • pp.1252-1258
    • /
    • 2015
  • The Liangshan pig is a traditional Chinese small-sized breed; it has a relatively long feeding period and low meat production ability but superior meat quality. This study utilized three non-linear growth models (Von Bertalanffy, Gompertz, and logistic) to fit the growth curve of Liangshan pigs from an unselected, random-bred pig population and estimate the pigs most suitable slaughter weight. The growth development data at 20 time points of 275 Liangshan pigs (from birth to 250 d) were collected. To analyze the relative gene expression related to development, seven slaughter weight phases (50, 58, 66, 74, 82, 90, and 98 kg) (20 pigs per phase) were examined. We found that the Liangshan pig growth curve fit the typical S-curve well and that their growth turning point was 193.4 days at a weight of 62.5 kg, according to the best fit Von Bertalanffy model based on the goodness of fit criteria. Furthermore, we estimated that the most suitable slaughter weight was 62.5 to 74.9 kg based on the growth curve and the relative expression levels of growth-related genes.

An Application of Hilbert-Huang Transform on the Non-Stationary Astronomical Time Series: The Superorbital Modulation of SMC X-1

  • Hu, Chin-Ping;Chou, Yi;Wu, Ming-Chya;Yang, Ting-Chang;Su, Yi-Hao
    • Journal of Astronomy and Space Sciences
    • /
    • v.30 no.2
    • /
    • pp.79-82
    • /
    • 2013
  • We present the Hilbert-Huang transform (HHT) analysis on the quasi-periodic modulation of SMC X-1. SMC X-1, consisting of a neutron star and a massive companion, exhibits superorbital modulation with a period varying between ~40 d and ~65 d. We applied the HHT on the light curve observed by the All-Sky Monitor onboard Rossi X-ray Timing Explorer (RXTE) to obtain the instantaneous frequency of the superorbital modulation of SMC X-1. The resultant Hilbert spectrum is consistent with the dynamic power spectrum while it shows more detailed information in both the time and frequency domains. According to the instantaneous frequency, we found a correlation between the superorbital period and the modulation amplitude. Combining the spectral observation made by the Proportional Counter Array onboard RXTE and the superorbital phase derived in the HHT, we performed a superorbital phase-resolved spectral analysis of SMC X-1. An analysis of the spectral parameters versus the orbital phase for different superorbital states revealed that the diversity of $n_H$ has an orbital dependence. Furthermore, we obtained the variation in the eclipse profiles by folding the All Sky Monitor light curve with orbital period for different superorbital states. A dip feature, similar to the pre-eclipse dip of Her X-1, can be observed only in the superorbital ascending and descending states, while the width is anti-correlated with the X-ray flux.

Phase Transformation of Silicon by Indentation (압입법에 의한 실리콘의 상전이)

  • Kim, Sung-Soon;Lee, Hong-Lim
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.12
    • /
    • pp.1149-1152
    • /
    • 2002
  • Indentation was used to analyze high pressure phases of silicon. Phase transformations on both loading time and loading rate were studied. Micro-raman spectroscopy was used to observe the indentation-induced transformations. As the loading time increased, Si-III and Si-XII disappeared and only a-Si was observed in (111) samples. As the loading time increased, the residual stress was removed by creation of cracks or dislocations. At 0.1 mm/min loading rate, pop-in . At 5 mm/min loading rate pop-in was observed in force/displacement curve of (111) sample, but pop-in was not observed in force/displacement curve of (100) sample. This result indicates that the loading rate affects the volume of phase transformation in silicon.

Adaptive thresholding for eliminating noises in 2-DE image (2차원 전기영동 영상에서 잡영을 제거하기 위한 적응적인 문턱값 결정)

  • Choi, Kwan-Deok;Kim, Mi-Ae;Yoon, Young-Woo
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.1
    • /
    • pp.1-9
    • /
    • 2008
  • One of the problems for implementing the spot detection phase in the 2-DE gel image analysis program is the eliminating noises in the image. Remained noises after the preprocessing phase cause the over-segmented regions by the segmentation phase. To identify and exclude the over-segmented background regions, if we use the fixed thresholding method that is choosing an intensity value for the threshold, the spots that is invisible by the eyes but mean a very small amount proteins which have important role in the biological samples could be eliminated. This paper propose an adaptive thresholding method that come from an idea that is got on statistical analysing for the prominences of the peaks. The adaptive thresholding method works as following. Firstly we calculate an average prominence value curve and fit it to exponential function curve, as a result we get parameters for the exponential function. And then we calculate a threshold value by using the parameters and probability distribution of errors. Lastly we apply the threshold value to the region for determining the region is a noise or not. According to the probability distribution of errors, the reliability is 99.85% and we show the correctness of the proposed method by representing experiment results.

  • PDF

Determination of Non-Steroidal Anti-Inflammatory Drugs in Human Urine Sample using HPLC/UV and Three Phase Hollow Fiber-Liquid Phase Microextraction (HF-LPME)

  • Cha, Yong Byoung;Myung, Seung-Woon
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.11
    • /
    • pp.3444-3450
    • /
    • 2013
  • Three phase hollow fiber-liquid phase microextraction (HF-LPME), which is faster, simpler and uses a more environmentally friendly sample-preparation technique, was developed for the analysis of Non-Steroidal Anti-Inflammatory Drugs (NSAIDs) in human urine. For the effective simultaneous extraction/concentration of NSAIDs by three phase HF-LPME, parameters (such as extraction organic solvent, pH of donor/acceptor phase, stirring speed, salting-out effect, sample temperature, and extraction time) which influence the extraction efficiency were optimized. NSAIDs were extracted and concentrated from 4 mL of aqueous solution at pH 3 (donor phase) into dihexyl ether immobilized in the wall pores of a porous hollow fiber, and then extracted into the acceptor phase at pH 13 located in the lumen of the hollow fiber. After the extraction, 5 ${\mu}L$ of the acceptor phase was directly injected into the HPLC/UV system. Simultaneous chromatographic separation of seven NSAIDs was achieved on an Eclipse XDB-C18 (4.6 mm i.d. ${\times}$ 150 mm length, 5 ${\mu}m$ particle size) column using isocratic elution with 0.1% formic acid and methanol (30:70) at a HPLC-UV/Vis system. Under optimized conditions (extraction solvent, dihexyl ether; $pH_{donor}$, 3; $pH_{acceptor}$, 13; stirring speed, 1500 rpm; NaCl salt, 10%; sample temperature, $60^{\circ}C$; and extraction time, 45 min), enrichment factors (EF) were between 59 and 260. The limit of detection (LOD) and limit of quantitation (LOQ) in the spiked urine matrix were in the concentration range of 5-15 ng/mL and 15-45 ng/mL, respectively. The relative recovery and precision obtained were between 58 and 136% and below 15.7% RSD, respectively. The calibration curve was linear within the range of 0.015-0.96 ng/mL with the square of the correlation coefficient being more than 0.997. The established method can be used to analyse of NSAIDs of low concentration (ng/mL) in urine.