• Title/Summary/Keyword: Curtain effect

Search Result 104, Processing Time 0.022 seconds

The Effects of Winch-curtain Ventilation on the Indoor Environment of a Fattening Swine House (윈치커튼 환기가 비육돈사의 실내 환경에 미치는 영향)

  • Kim, Hyeon-Tae;Song, Jun-Ik;Choi, Hong-Lim
    • Journal of Animal Environmental Science
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • The study was conducted to investigate the effects of climate on indoor environment of a swine house with natural. This study was tested in the beef swine stall at Young-in, Kyung-ki do. The test was experimented for the effect of interior environment by the outdoor environment and the interior-pan. The results are as follows. 1. In test 1 ($T_{out}$ : $25.7^{\circ}C$, without fan), an indoor air flow pattern was showed that entered from sidewall winch-curtain to went out of a indoor by the ridge winch-curtain. And the velocity of a section of the center was measured two times as large as the velocity of the floor. It is the acceleration of the velocity by thermal buoyancy. And, the entered air was rapidly dissipated by flow energy. So that in the swain livestock with sidewall winch-curtain is effected by thermal buoyancy. And the air temperature of the indoor was distributed more higher as compared with the outdoor temperature. This result is caused by the sensible heat from swine and the ventilation is restricted. 2. In test 2 (($T_{out}$ : $25.7^{\circ}C$, with fan), the velocity of a section of the center was measured more higher as compared with the test 1. And the variance of air velocity was distributed higher as compared with the test 1. This result is showed dead region of air flow with a fan operation. And, the variance of gas density was distributed lower as compared with the test 1.

A Case Study on the Ground Reinforcement Method and Effect of the Failed Tunnel (터널붕괴지반의 보강공법 및 효과에 대한 사례연구)

  • Cho, Hyun;Lim, Jae-Seung;Chung, Yoon-Young;Choi, Sang-Yeul
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.03a
    • /
    • pp.293-300
    • /
    • 1999
  • The maintenance for the stability of tunnel, especially on downtown area, careful check must be considered during construction stage and after. Moreover we have to achieve the stability of tunnel by ground improvement and reinforcement when ground condition is bad or tunnel failures under the various ground conditions. In this paper, it is presented the case of tunnel failure and the state of restoration by ground reinforcements at seoul subway $\bigcirc$-$\bigcirc$ construction site. For the purpose of ground reinforcement, first, curtain wall was established by chemical grouting. Secondly, cement milk grouting was carried by upper part of tunnel crown. Also Boreholes loading test and tunnel monitoring were carried by in failure site for the long term stability of tunnel.

  • PDF

Performance Analysis of Combined Passive Solar System for Building South Wall (남측외벽에 적용한 혼합형 태양열시스템의 성능 분석)

  • Yun, Tae-Gyun;Lee, Hyun-Soo;Jang, Hyang-In;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.2
    • /
    • pp.42-49
    • /
    • 2012
  • In this article, the author carried out a theoretical study on the application techniques of a new Combined Passive Solar System (hereinafter referred to as the CPSS) of direct gain and trombe walls to get quick morning heating and to prevent afternoon overheating for office building. The numerical model proposed in this study can be used for the performance analysis of the CPSS in the winter and summer. Heating and Cooling loads are analysed for building energy consumption reduction using this numerical model. The results indicate that CPSS in the winter and summer modes could provide profitable conditions for improvement of indoor thermal comfort control and energy saving. consequently, the application of CPSS will not lead to significant reductions in the auxiliary air conditioning demand but also realize the environmentally friendly building.

Optimized slat angle control algorithm prediction of venetian blind depending on window orientation for energy saving (건물에너지 저감을 위한 향별 슬랫형 블라인드의 최적각도 제어 알고리즘 산출)

  • Kwon, Hyuk-Ju;Lee, Keum-Ho;Lee, Kwang
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.99-106
    • /
    • 2017
  • Purpose: Most modern office buildings adopt the curtain wall system in order to provide occupants with the sense of openness and high-technology, which requires large window area. As a result, the amount of solar radiation increases, negatively affecting cooling load during the summer and increasing energy costs. However, the performance of window itself is not sufficiently controllable parameter to control thermal comfort and solar radiation. Therefore, a shading device such as venetian blind is required to control them and thus a variety of studies have been performed thus far. So, the purpose of this study is to improve the performance of blind through the development of blind control algorithm. Method: Among various input variables for the control of venetian blinds, the vertical solar radiation has been selected in this study as the primary input variable and the optimal control algorithm for venetian blinds were developed for each window orientation. Result: The developed optimal control algorithm has a positive effect on building energy savings.

Prediction of Time-dependent Lateral Movement Induced by Differential Shortening in Tall Buildings Using Construction Stage Analysis

  • Ha, Taehun;Kim, Sangdae;Lee, Sungho
    • International Journal of High-Rise Buildings
    • /
    • v.6 no.1
    • /
    • pp.11-19
    • /
    • 2017
  • High-rise buildings move during construction due to time-dependent material properties of concrete (creep and shrinkage), construction sequences, and structural shapes. The building movements, including vertical and horizontal displacements, result from the sum of axial and lateral deformation of vertical members at each level. In addition to the vertical shortenings, the lateral movement induced by differential shortening can have adverse effects on the construction tolerance and serviceability of non-structural elements such as elevators and curtain walls. In this study a construction stage analysis method is developed to predict lateral movement induced by shortening, including the effect of creep and shrinkage. The algorithm of construction stage analysis is combined with the FE analysis program. It is then applied to predict lateral movement of a 58-story reinforced concrete building that was constructed in Kuala Lumpur, Malaysia. Gravity induced lateral movement of this building is predicted by the construction stage analysis. A field three-dimensional laser scanning survey is carried out to verify the prediction results, and satisfactory agreement is obtained.

Analysis of the Correlation between Climatic Elements and Electricity Generation of Building Integrated Photo Voltaic on Gymnasium Building's Curtain Wall (체육관 커튼월에 설치된 건물일체형 태양광발전시스템의 발전량과 기후 요소 간의 상관성 분석)

  • Park, Kang-Hyun;Lee, Jeong-Hun;Kim, Su-Min;Park, Kyung-Won
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.1
    • /
    • pp.8-14
    • /
    • 2012
  • Concerning about global warming due to emission of greenhouse effect gas like C02 and depletion of fossil fuels have been spreading. So the need for solar energy utilization is increased. It is essentially important to make efforts to reduce usage of fossil energy resources. In this study, we analyzed the correlation between climatic elements and the photovoltaic power generation. Cloud cover of the correlation coefficient was 0.93. The order of the correlation coefficient was average temperatures, hours of sunshine duration of sunshine and the humidity. To accurately analyze of the degree of correlation for the photovoltaic power generation, additional research about climatic elements that show a high correlation is needed.

Effects of Slits and Swirl Vanes on the Main Flow Fields of a Gun-Type Gas Swirl Burner (슬릿과 스월베인이 Gun식 가스버너의 주 유동장에 미치는 영향)

  • Kim, J.K.;Jeong, K.J.
    • Journal of Power System Engineering
    • /
    • v.6 no.4
    • /
    • pp.23-29
    • /
    • 2002
  • This paper is studied to investigate the effect of slits and swirl vanes on the main flow fields of a gun-type gas burner through X-Y plane and Y-Z plane respectively by using X-probe from hot-wire anemometer system. This experiment was carried out with flow rate $450{\ell}/min$ in respective burner models installed in the test section of a subsonic wind tunnel. The burner models with only slits and only swirl vanes respectively were made by modifying original gun-type gas burner. The fast jet flow spurted from slits played a role such as an air-curtain because it encircled rotational flow by swirl vanes and drives mixed main flow to axial direction. As a result, the gun-type gas burner had a wider flow range up to about Y/R=1.5 deviated from slits and maintains a comparatively large velocity in the central part of burner within the range of about X/R=2.5. Therefore, it was very desirable that swirl vanes were installed within slits in gun-type gas burner in order to control the main flow fields effectively.

  • PDF

A Study on the Temperature Change of Green House using Aerogel (에어로젤을 사용한 시설하우스의 온도 변화에 대한 연구)

  • Yang, Ji-Ung;Lee, Eun-Suk;Ko, Joon-Young;Kim, Won-Kyung;Byun, Jae-Young;Park, Jin-Gyu;Choi, Won-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.6_2
    • /
    • pp.1067-1074
    • /
    • 2020
  • Green houses provide a more conditioned and warmer environment than the outside environment due to insulation. Currently used insulation materials include soft film (PVC, PE, EVA), foamed PE sheet, non-woven fabric, reflective film, and multi-layer insulation curtain, but there are many disadvantages and to compensate for this, silica aerogel insulation material with excellent warmth, light weight, and small volume Research using is in progress. In this study, the temperature change of the quadruple-structure green house and the temperature change in the dual-structure green house of soft film and silica airgel were investigated. The daytime temperature change was highest in A and A2 (soft film) at 10 to 16:00 after sunrise, but showed the lowest temperature at 17 to 18:00, which is the sunset time, showing the greatest change. The airgels of D and D2 showed the smallest change in temperature after sunrise and right after sunset. That is, it can be said that the airgel is hardly affected by external temperature. The temperature change at night was highest in D and D2 (aerogel) for both quadruple and dual structures. The temperature at night was measured higher in the quadruple structure than in the double structure. As for the ratio of the internal temperature to the external temperature for the quadruple structure and the double structure, D (aerogel) was not affected by the external temperature during the day in the quadruple structure and the double structure. D (Aerogel) seems to be able to reduce the damage caused by high temperatures in summer due to the high thermal insulation effect of the airgel, as the temperature rises above 4℃ at night. And in winter, it helps to save heating costs due to less heat emitted to the outside.

Effects of Halogen and Light-Shielding Curtains on Acquisition of Hyperspectral Images in Greenhouses (온실 내 초분광 영상 취득 시 할로겐과 차광 커튼이 미치는 영향)

  • Kim, Tae-Yang;Ryu, Chan-Seok;Kang, Ye-seong;Jang, Si-Hyeong;Park, Jun-Woo;Kang, Kyung-Suk;Baek, Hyeon-Chan;Park, Min-Jun;Park, Jin-Ki
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.23 no.4
    • /
    • pp.306-315
    • /
    • 2021
  • This study analyzed the effects of light-shielding curtains and halogens on spectrum when acquiring hyperspectral images in a greenhouse. The image data of tarp (1.4*1.4 m, 12%) with 30 degrees of angles was achieved three times with four conditions depending on 14 heights using the automatic image acquisition system installed in the greenhouse at the department of Southern Area of National Institute of Crop Science. When the image was acquired without both a light-shielding curtain and halogen lamp, there was a difference in spectral tendencies between direct light and shadow parts on the base of 550 nm. The average coefficient of variation (CV) for direct light and shadow parts was 1.8% and 4.2%, respective. The average CV value was increased to 12.5% regardless of shadows. When the image was acquired only used a halogen lamp, the average CV of the direct light and shadow parts were 2 .6% and 10.6%, and the width of change on the spectrum was increased because the amount of halogen light was changed depending on the height. In the case of shading curtains only used, the average CV was 1.6%, and the distinction between direct light and shadows disappeared. When the image was acquired using a shading curtain and halogen lamp, the average CV was increased to 10.2% because the amount of halogen light differed depending on the height. When the average CV depending on the height was calculated using halogen and light-shielding curtains, it was 1.4% at 0.1m and 1.9% at 0.2 m, 2 .6% at 0.3m, and 3.3% at 0.4m of height, respectively. When hyperspectral imagery is acquired, it is necessary to use a shading curtain to minimize the effect of shadows. Moreover, in case of supplementary lighting by using a halogen lamp, it is judged to be effective when the size of the object is less than 0.2 m and the distance between the object and the housing is kept constant.

The Effect in Heat Controlling and Perceptions Towards Home Furnishing Fabrics - Focus on Curtains and Draperies - (주택에서 내장재로 쓰이는 섬유의 절약효과와 소비자의식에 관한 연구 - 커어튼을 중심으로 -)

  • 윤복자
    • Journal of the Korean Home Economics Association
    • /
    • v.20 no.1
    • /
    • pp.65-77
    • /
    • 1982
  • The intent of this study was to focus attention on the relationship between curtain fabrics and consumer perceptions towards curtains and draperies. This study consisted of the laboratory test for thermal transmittance of selected fabrics and the exploratory survey for consumer perceptions towards curtains and draperies. The objectives of the laboratory test were to measure fabric's thermal transmittance, thickness, and count which affect to the effect in heat controlling. Selected 23 fabrics were tested at Korean Yarn and Fabrics Testing Inspection Institute. The objectives of the exploratory survey were to determine sociodemographic factors; the stage of family life cycle, the economics status, and homemaker's level of education, and physical factors; the type of houses, the direction of windows, and the type of windows, affect consumer perceptions toward curtains and draperies. Questionaires were administered to 489 homemakers selected by a stratified propotional sampling plan, in Seoul in October, 1981. Data from responses were analyzed by T-test(Analysis of Varience) and Partial Correlation. The major findings are as follows; 1. The results of the laboratory test 1) The fabrics used for draperies had higher effect in heat controlling than the fabrics used for glass curtains. 2) It did not show much differences among the fibers in heat controlling. The thicker fibers, however, had the higher effect in heat controlling among same fibers. 3) The fabrics which had high level of effect I heat controlling were corduroy, flax, rayon, nylon, acetate, thick polyester, and thick polyacrylic. The fabrics which had midium level of affect in heat controlling were velveteen, velvet, and thin polyester. The fabrics which had low level of effect in heat controlling were cotton, silk, and thin polyarcylic. 4) The draperies with lining showed 2∼5 times more effective in heat controlling than the draperies without lining. 2. The results of the exploratory survey Consumer perceptions towards curtains and draperies consisted of functional, financial, and aesthetic perception. 1) Factor affecting functional perception towards curtains and draperies was the stage of family life cycle. Families in the contracting stage considered function of curtains and draperies significantly better than those in others stages. 2) Factors affecting financial perception towards curtains and draperies were the economic status, homemaker's level of education, the direction of windows, and the type of windows. However the correlation between the factors and financial perception was too low to explain the significance of tendency. 3) There was not any factors affecting aesthetic perception towards curtains and draperies.

  • PDF