Effect analysis of geothermal cooling and heating system (지열냉난방 시스템의 효과 분석)

  • Kim, Byeong-Kak;Kim, Yong-Hwan;Kim, Jong-Deug
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1146_1147
    • /
    • 2009
  • This experiment is significant because we can provide information by measuring effect of energy saving for whom plan to install a geothermal heat & cooling system. The result shows geothemal system can save about 50% of energy(heating : 35%, cooling : 60%) and we verified that when using curtain can help saving 4~12% of energy additionally.

  • PDF

Effect analysis of geothermal cooling and heating system (지열(수온차)냉난방 시스템 효과 분석)

  • Chung, Hoon;Ma, Bum-Gu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.365-368
    • /
    • 2008
  • This experiment is significant because we can provide information by measuring effect of energy saving for whom plan to install a geothermal heat & cooling system. The result shows geothemal system can save about 50% of energy(heating : 35%, cooling : 60%) and we verified that when using curtain can help saving $4{\sim}12%$ of energy additionally

  • PDF

Survey Research on Thermal Situation of Office Buildings (사무소 건축물의 단열상황에 관한 조사연구)

  • Jung, Ui In;Kim, Bong Joo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.3
    • /
    • pp.145-152
    • /
    • 2013
  • This study is to evaluate the thermal insulation of the curtain wall of the buildings constructed since the 1990s to the buildings currently under construction in 2011 and to provide the basic data for repairing and reinforcing and designing the thermal insulation. To this effect, the temperature difference by part was analyzed through measuring the inside and outside surface temperature of the curtain wall of the office building, and thereafter, the conditions of the thermal insulation and the thermal bridge part were examined. The result of the study is as follows; Not only in the winter season when the temperature difference between the indoor-outdoor is over $20^{\circ}C$, but also in the summer season when there is a small temperature difference, the temperature difference between the inside and outside of the frame is $2^{\circ}C{\sim}4^{\circ}C$ equally. Under such conditions as stated above, the thermal bridge occurred, which resulted from the heat flow of the steel frame part (mullion, transom), and therefore, the reinforcement of the thermal insulation is considered to be needed.

A Study of Numerical Analysis on Hydrogeological Influence by Groundwater Development around Underground Oil Storage Cavern (지하 석유비축기지 주변의 지하수 개발에 의한 수리지질학적 영향의 수치해석 연구)

  • 정현영;송무영;이경주
    • The Journal of Engineering Geology
    • /
    • v.11 no.1
    • /
    • pp.37-50
    • /
    • 2001
  • Through the modeting study on the groundwater now system around the underground stockpile site of crude oil near Seoul, we carried out the research on the influence of the groundwater yield near the site, the effect of the water curtain construction in order to reduce the influence of water yield, and the realized case study by measuring the water level change after the construction of the water curtain. For the simu1ation of the water yield and the water curtain, the nwnerical analysis code, MODFLOW has been utilized. Groundwater levels of the observation wells which were established to observe the hydraulic head around underground oil storage cavern of the study area have been changed in the range of from EL.+30 to +60 meter, while the simulation study revealed that groundwater levels changed in the range of from EL.+20 to +5Om. The hydrogeological condition of the underground oil storage cavern becomes stable by injection water to maintain the groundwater level around the cavern. The result shows the proper input of the hydrogeological factors helps the management to be effective for the oil stockpile site.

  • PDF

A Comparative Experiment on Thermal Stress Failure of Vacuum Glazing applied in Curtain Wall at Spandrel area (커튼월 스팬드럴용 진공유리의 열파손에 대한 비교실험)

  • Kim, Seung-Chul;Yoon, Jong-Ho;Shin, U-Cheol;Ahn, Jung-Hyuk
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.121-128
    • /
    • 2016
  • Purpose: The vacuum glazing should constantly retain the gap in vacuum state to maintain high thermal performance. To do so, pillars are used to prevent the glazing from clinging to each other by the atmospheric pressure and therefore surface of the vacuum glazing is consistently affected by residual stress. The vacuum glazing could be applied to curtain wall systems at spandrel area to fulfill a rigorous domestic standard on U-value of the external wall. However, this can lead to high glazing temperature increase by heat concentration at a back panel and finally thermal stress breakage. This study experimentally determined weakness of the vacuum glazing systems on the thermal stress breakage and investigated effect of the residual stress. Method: The experiment first built two scale-down mock-up facilities that replicate the spandrel area in curtain wall, and then installed single low-e glass and vacuum glazing respectively. The two mock-up facilities were exposed to outside to induce the thermal stress breakage. Result: The experiment showed that the temperature occurred the thermal stress breakage was $114.4^{\circ}C$ for the single low-e glass and $118.9^{\circ}C$ for the vacuum glazing respectively. The result also showed the vacuum glazing reached the critical point earlier than the single low-e glass, which means that the vacuum glazing has high potential to occur the thermal shock breakage. In addition, the small temperature difference between two glazing indicates that the residual stress scarcely affects breakage of the vacuum glazing.

Statistical Review for New USNCAP Side Crash Test Results (새로운 미국 측면 신차안전도평가 결과에 대한 통계적 분석)

  • Beom, Hyenkyun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.2
    • /
    • pp.104-113
    • /
    • 2013
  • New USNCAP has been carried out by NHTSA including front and side crash from MY2011. In this paper, test results for USNCAP Side crash were reviewed by statistical analysis. This review focused on side crash test results to investigate the effect of changes from new USNCAP side crash test protocol among 30 passenger cars. These results were summarized as followings. Total number of 5 star vehicles on the front seat dummy (16 vehicles, 53.3%) was slightly smaller than the rear seat's (17 vehicles, 56.7%) in MDB test. For the ES-2re dummy, chest injury, ie maximum rib deflection contributed to 66% in the mean value of $P_{joint}$. Pelvis injury was highly dependent upon performance up to 87% in the SID-IIs dummy cited on the rear seat in average $P_{joint}$. For Pole test, pelvis injury made contribution to the average performance to 83%. For standard deviation, it showed the largest value in the same body region as the mean value for each dummy. Overall front seat performance showed 14 vehicles, 44.6% with 5 star vehicles less than each MDB or Pole test result. This result showed that performances in MDB test were different pattern to Pole test on driver position. Number of 5star vehicles for overall side NCAP performance are 18 passenger cars (60%). Curtain airbag and driver thorax airbag were equipped in all test vehicles. One vehicle is equipped with thorax airbag in the rear seat. Results from two side tests considered as reliability problem, ie the cause for large standard deviation in side crash test. Consequently, the countermeasure for new USNCAP side crash test is essential to design the effective side structures for side collision and to control well dummy kinematics with curtain and thorax airbag in order to reduce chest and pelvis injuries.

The Advanced Case Study for Investigation on Application of BIPV on Tall Building (초고층빌딩의 BIPV 적용성 검토를 위한 선진 사례 조사)

  • Lee, Jong-Min;Seok, Ho-Tae;Yang, Jeong-Hoon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.155-160
    • /
    • 2009
  • The increasingly high prices for oil, the exhaustion of fossil fuels as well as concern about global warming are driving rapid growth of alternative sources of energy in the world. The active solution for global environment and exhaustion of energy sources is to develop and popularize the technologies to use natural energy such as sunlight, wind, and water. PV(Photovoltaic) modules are efficient devices that has been considered a logical material for use in buildings. Recent advanced BIPV(Building Integrated PV) technology have rapidly made PVs suitable for direct integration into construction in the world. Recently, building has been higher and higher. Tall buildings have many advantages for BIPV such as wide facade area and no shading effect by the surrounding buildings. However. BIPV has not been applied for tall building facade yet. Therefore, the purpose of the research is to develop suitable BIPV for tall buildings and to put these technologies to practical use. Therefore, the purpose of the study is to investigate unification of BIPV to curtain wall to apply BIPV on tall building through research into advanced application of overseas BIPV cases.

  • PDF

The Evaluation of Integrated Agricultural Resource Management Policy through Water-Energy-Food Nexus - An Application to Management of Aquifer Recharge Project - (물-에너지-식량 넥서스를 활용한 통합적 농업자원관리정책 평가 - 지하수 함양 사업을 중심으로 -)

  • Sung, Jae-hoon;Lee, Hyun-jung;Cho, Wonjoo
    • Journal of Korean Society of Rural Planning
    • /
    • v.25 no.4
    • /
    • pp.35-45
    • /
    • 2019
  • Korean agriculture experienced rapid changes in its production structure to respond fluctuations on external conditions, and these changes have increased the dependence between agricultural resources and negative environmental externalities from agricultural production. As a tool for managing agricultural resources and reducing negative environmental effects from agricultural production, this study employs water-energy-food nexus for integrated resource management. To show the necessity of an integrated approach, this study evaluated three policy scenarios including changes in capital interest, water capacity, and energy cost. The results show that three scenarios have unintended consequences for farmers' incomes and their use of resources. Also the unintended consequences of government policies also affected farms' vulnerability to environmental changes. In particular, the expansion of financing for the establishment of non-circulating water curtain facilities did not have a significant effect on the crop switching of farms. In addition, increasing the amount of available water through the aquifer recharge project leads to the installation of non-circulating water curtain facilities in zucchini farm. It raises dependence on groundwater in agricultural production, thereby increasing farmers' vulnerability to groundwater shortages. These results imply that the agricultural sector needs to consider the interrelationship between agricultural resources when designing or evaluating policies.

Analysis on the Bluegill Blocking Effects using Bubbles (버블을 이용한 파랑볼우럭 차단 효과 분석)

  • Kang, Joon-Gu;Kim, Jong-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.390-397
    • /
    • 2017
  • The introduction of exotic fish species may reduce the number of native fish species and disturb the aquatic ecosystem. Therefore, measures to block and manage fish species are required. Accordingly, a fish species blocking system using bubbles was developed in this study to block exotic fish species. An experimental channel was produced and the possibility of blocking such exotic fish species was evaluated. The bubble generator is a system that produces a bubble curtain by generating air with an air compressor that blocks fish species. Bluegill, which is an exotic fish species in the country, was tested with this generator. The size of bluegill was between 0.10 m and 0.15 m and the depth of water was maintained at 0.70 m. The flow velocity of the experiment channel was classified into 3 levels (0.20 m/s, 0.10 m/s, and 0.05 m/s) considering the natatorial ability of the fish species. The results revealed that 70.07% of bluegill showed movements to swim upstream before applying the bubble, but it is considered that the ascending rate would be higher given that the fish species thinks downstream is a habitat and showed almost no movement. However, when the blocking facility was installed, most fish species showed movements to return to the downstream again by the bubble curtain, indicating a very high blocking effect. In particular, when the generating bubble was terminated, the fish species swam back to the upstream area very soon, so the fish species blocking effect using the bubble was excellent.

Numerical analysis of solar heat gain on slim-type double-skin window systems - Heat transfer phenomena with opening of windows and vent slot in summer condition - (전산유체 해석을 통한 슬림형 이중외피 창호의 태양열 취득량 분석 - 높은 태양고도 및 하절기 냉방조건에서의 자연환기구 적용 및 창문 조절 방식별 비교 -)

  • Park, Ji-Ho;Oh, Eun-Joo;Cho, Dong-Woo;Cho, Kyung-Joo;Yu, Jung-Yeon
    • KIEAE Journal
    • /
    • v.17 no.1
    • /
    • pp.69-75
    • /
    • 2017
  • Purpose: Heat transfer analysis of recently developed 'slim type double-skin system window' were presented. This window system is designed for curtain wall type façade that main energy loss factor of recent elegant buildings. And the double skin system is the dual window system integrated with inner shading component, enclosed gap space made by two windows when both windows were closed and shading component effectively reflect and terminate solar radiation from outdoor. Usually double-skin system requires much more space than normal window systems but this development has limited by 270mm, facilitated for curtain wall façade buildings. In this study, we estimated thermophysical phenomena of our double-skin curtain wall system window with solar load conditions at the summer season. Method: A fully 3-Dimentional analysis adopted for flow and convective and radiative heat transfer. The commercial CFD package were used to model the surface to surface radiation for opaque solid region of windows' frame, transparent glass, fluid region at inside of double-skin and indoor/outdoor environments. Result: Steep angle of solar incident occur at solar summer conditions. And this steep solar ray cause direct heat absorption from outside of frame surface rather than transmitted through the glass. Moreover, reflection effect of shading unit inside at the double-skin window system was nearly disappeared because of solar incident angle. With this circumstances, double-skin window system effectively cuts the heat transfer from outdoor to indoor due to separation of air space between outdoor and indoor with inner space of double-skin window system.