• 제목/요약/키워드: Current transient phenomenon

검색결과 36건 처리시간 0.026초

교류발전기 병렬운전시 과도현상 해석에 관한 연구 (A Study on the Transient Phenomenon Analysis at the instant of Parallel Running for A.C. Generators)

  • 오세진;김현수;김성환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권5호
    • /
    • pp.1065-1075
    • /
    • 2001
  • It is common knowledge amongst electrical and marine engineers that short-circuit in electrical system may cause large mechanical torque on generator and prime mover However, it is not so widely known that the faulty synchronizing of generators may cause even higher torques than that of short-circuit. In this study, the transient phenomena related to the parallel running of synchronous generators are analyzed and the exact computer simulation method is proposed. In result, maximum transient torque and current take place in case of $120^{\circ}$ voltage angle difference between Master and Slave and that may develop higher torque than the short-circuit according to a condition of synchronizing. When synchronizing in power system using only two generators higher torque and current occur Master, but using multimachine system those occur to Slave. The short-circuit of marine generator does not happen frequently but faulty synchronizing sometimes takes place, therefore, it is necessary for designers to consider these phenomena.

  • PDF

분로리액터 개폐 과전압 해석을 위한 EMTP 모델링 (Electromagnetic Transient Program Modeling for Analysis of Switching Over-Voltage on Shunt Reactor)

  • 오승열;전인영;한기선;강지원
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권4호
    • /
    • pp.393-397
    • /
    • 2020
  • 무효전력 보상설비인 분로리액터는 전력계통의 부하 패턴에 따라서 하루에도 수 회 정도 차단기에 의해 운전되거나 정지된다. 분로리액터개폐 시 몇 가지 요인에 의해 발생하는 과전압은 차단기의 절연 성능을 저하시키며, 계통을 구성하는 전력기기에 심각한 전압 스트레스를 유발한다. 분로리액터 개폐 과정에서 발생하는 과도현상을 측정하는 것은 계통을 모의하여 차단기 성능을 검증하는 시험소 수준에서는 가능하나, 실제 계통 운전 중에 발생하는 과도현상을 측정하는 것은 여러 가지 제약으로 어려움이 있다. 따라서 본 논문에서는 실 계통에서 지상 소전류 차단과정에서 가혹한 과도회복전압(TRV: Transient Recovery Voltage)을 유발하는 재발호(reignition)나 전류재단(current chopping) 현상에 대한 해석을 위해 전자계과도해석프로그램(EMTP: Electro-magnetic Transients Program)을 활용한 모델링 과정과 이를 토대로 분로리액터 개폐 과정에서 차단기의 고장을 유발하는 주된 현상에 대해 해석하고자 한다.

Unsteady Single-Phase Natural Circulation Flow Mixing Prediction Using CATHARE Three-Dimensional Capabilities

  • Salah, Anis Bousbia;Vlassenbroeck, Jacques
    • Nuclear Engineering and Technology
    • /
    • 제49권3호
    • /
    • pp.466-475
    • /
    • 2017
  • Coolant mixing under natural circulation flow regime constitutes a key parameter that may play a role in the course of an accidental transient in a nuclear pressurized water reactor. This issue has motivated some experimental investigations carried out within the OECD/NEA PKL projects. The aim was to assess the coolant mixing phenomenon in the reactor pressure vessel downcomer and the core lower plenum under several asymmetric steady and unsteady flow conditions, and to provide experimental data for code validations. Former studies addressed the mixing phenomenon using, on the one hand, one-dimensional computational approaches with cross flows that are not fully validated under transient conditions and, on the other hand, expensive computational fluid dynamic tools that are not always justified for large-scale macroscopic phenomena. In the current framework, an unsteady coolant mixing experiment carried out in the Rossendorf coolant mixing test facility is simulated using the three-dimensional porous media capabilities of the thermal-hydraulic system CATHARE code. The current study allows highlighting the current capabilities of these codes and their suitability for reproducing the main phenomena occurring during asymmetric transient natural circulation mixing conditions.

전기철도차량 주변압기의 %임피던스에 따른 차단기 개폐시 과도특성 분석 (Transient Characteristics by Transformer %Impedance at the time of Opening the Main Circuit Breaker on the Electric Railway Vehicle)

  • 창상훈
    • 전기학회논문지
    • /
    • 제63권5호
    • /
    • pp.719-725
    • /
    • 2014
  • Transient of Electric railway vehicle occurs when change to another state. The duration of the transient phenomenon only takes a few second. During this time is considered, the present of short circuit current and the normal state, the energy is present in the form of a magnetic field. Recognized by the vibration of the transient voltage or transient current at witch energy is present in the field. This paper is presented the result of transient characteristics by transformer % impedance at the time of opening and closing of the main circuit Breaker on the electric railway vehicle.

A Cost-Effective, Single-Phase Line-Interactive UPS System that Eliminates Inrush Current Phenomenon for Transformer-Coupled Loads

  • Bukhari, Syed Sabir Hussain;Atiq, Shahid;Lipo, Thomas A.;Kwon, Byung-il
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권3호
    • /
    • pp.675-682
    • /
    • 2016
  • Sudden voltage drops and outages frequently disturb the operation of sensitive loads for domestic, commercial, and industrial use. In some cases, these events may even impair the functioning of relevant equipment. To maintain power under such conditions, a UPS system is usually installed. Once a disturbance happens at the grid side, the line-interactive UPS system takes over the load to prevent an interruption. But, due to magnetic saturation of the transformer, a significant inrush current may occur for the transformer-coupled loads during this transition. The generation of such transient currents may in turn decrease the line voltage and activates over-current protecting devices of the system. In this work, a cost-effective, line-interactive UPS system is proposed that eliminates the inrush current phenomenon associated with transformer-coupled loads. The strategy was implemented by connecting a standard current-regulated voltage source inverter (CRVSI) to the secondary winding of the load transformer. During any transient condition at the grid side, the load current is monitored and regulated to achieve either seamless compensation of the load current or complete transferal of load from grid to the inverter. Experimental results were obtained for a prototype under all possible operating conditions so as to validate the performance of the proposed topology.

과도방사선에 의한 CMOS 소자 Latch-up 모델 연구 (A Study of CMOS Device Latch-up Model with Transient Radiation)

  • 정상훈;이남호;이민수;조성익
    • 전기학회논문지
    • /
    • 제61권3호
    • /
    • pp.422-426
    • /
    • 2012
  • Transient radiation is emitted during a nuclear explosion. Transient radiation causes a fatal error in the CMOS circuit as a Upset and Latch-up. In this paper, transient radiation NMOS, PMOS, INVERTER SPICE model was proposed on the basisi of transient radiation effects analysis using TCAD(Technology Computer Aided Design). Photocurrent generated from the MOSFET internal PN junction was expressed to the current source and Latch-up phenomenon in the INVERTER was expressed to parasitic thyristor for the transient radiation SPICE model. For example, the proposed transient radiation SPICE model was applied to CMOS NAND circuit. SPICE simulated characteristics were similar to the TCAD simulation results. Simulation time was reduced to 120 times compared to TCAD simulation.

진공차단기 3상 동시 차단시의 서지 특성 분석 (Surge Characteristics Analysis of Three-phase Virtual Chopping at Vacuum Circuit Breaker)

  • 김종겸
    • 전기학회논문지
    • /
    • 제67권9호
    • /
    • pp.1159-1164
    • /
    • 2018
  • Vacuum circuit breakers(VCB) are widely used for current interruption of high-voltage inductive loads such as induction motors. This VCB can be chopped off before the current zero due to its high arc-extinguishing capability. One of the outstanding features of VCB is that it can cut off high frequency re-ignition current more than other circuit breakers. If the transient recovery voltage generated in the arc extinguishing is higher than the dielectric strength of the circuit breaker, a re-ignition phenomenon occurs. The surge voltage of the re-ignition is very high in magnitude and the steepness of the waveform is so severe that it can act as a high electrical stress on the winding. If the high frequency current of one phase affects the other two phases when the re-ignition occurs, it may cause a high surge voltage due to the virtual current chopping. If the magnitude of the voltage allowed in the motor winding is high or the waveform level is too severe, it may lead to insulation breakdown. Therefore, it is necessary to reduce the voltage to within a certain range. In this study, we briefly explain the various phenomena at the time of interruption, analyzed the magnitude of the dielectric strength and the transient recovery voltage at the simultaneous three-phase interruption that can give the greatest influence to the inductive load, proposed a method to reduce the impact.

전기적 과도현상으로부터 통신망의 보호대책 (The Protection methods of Telecommunication Network from Electrical Transient Phenomena)

  • 최만호;김현덕;김병철
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2005년도 추계종합학술대회
    • /
    • pp.693-696
    • /
    • 2005
  • 국내의 통신망은 효율적인 유지보수를 위하여 도로를 따라 기반시설이 구축되고 있기 때문에 전력망과 통신망의 교차와 병행이 가속화되고 있다. 전력망은 전력유도를 발생시킬 뿐만 아니라, 낙뢰와 같은 전기적 과도현상으로부터 그 자체가 전송매체로 되기 때문에 전력망 지중 접지체와 통신망 지중 접지체간을 통하여 낙뢰서지 및 지락선 과도 현상이 통신망에 유도되어 악영향을 초래한다. 본 연구에서는 통신망의 보호대책으로 지중접지체간의 이격거리를 통한 귀로전류의 차단과 양쪽 단자의 유휴심선을 접지하여 전력유도전압을 차폐하는 방법이 우수한 효과를 나타냄을 확인 할 수 있었다.

  • PDF

전원외란 시뮬레이터를 이용한 고속전철 이선현상과도 특성 연구 (Transient Characteristic Study on Contact Loss of High Speed Electric Railway Using a Power Line Disturbance Simulator)

  • 김재문;김양수
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.427-431
    • /
    • 2009
  • In this study, the dynamic characteristic of a contact wire and pantograph suppling electrical power to high-speed trains are investigated from an electrical response point of view. To analysis power line disturbance by induced contact loss phenomenon for high speed operation, a hardware Simulator which considered contact loss between contact wire and the pantograph as well as contact wire deviation is developed. It is confirmed that a contact wire and pantograph model are necessary for studying the dynamic behavior of the pantograph system. One of the most important needs accompanied by increasing the speed of high-speed train is reduced that an arc phenomenon by loss of contact brings out EMI. In case of a high-speed train using electrical power, as comparison with diesel rolling stock, PLD(Power Line Disturbance) such as harmonic, transient voltage and current, EMI(Electromagnetic Interference), dummy signal injection etc usually occurs. Throughout experiment, it is verified that an arc phenomenon is brought out for simulator operation and consequently conducted noise is flowed in electric circuit by power line disturbance.

A Novel Simulation Scheme for Grid Connected Photovoltaic Generation Systems

  • Park, Monwon;Kim, Bong-Tae;Yu, In-Keun
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제11B권4호
    • /
    • pp.169-174
    • /
    • 2001
  • A novel simulation scheme of transient phenomenon for the photovoltaic (PV) generation system under the real weather conditions has been proposed in this paper. A grid connected PV array is simulated using PSCAD/EMTDC. The transient changes of the output current of PV array under the real weather conditions is described and the output current of DC/AC converter flowing through the utility power network is also analyzed with the PWM switching width. Moreover, the MPPT control of PV generation system is combined to the system during the simulation for the comparison purposes of the control schemes. The outcome of the simulation demonstrates the effectiveness of the proposed simulation scheme. The result shows that the cost effective verifying for the efficiency or availability and stability of PV generation systems and the comparison research of various control schemes like MPPT under the same real whether conditions are eventually possible.

  • PDF