• Title/Summary/Keyword: Current transient

Search Result 1,271, Processing Time 0.029 seconds

Characteristics of the Switching Surge Voltages Induced at Metal Flexible Conduits Due to Ground Faults (지락고장에 의해 금속제 유연전선관에 유도된 개폐서지전압의 특성)

  • Lee, Bok-Hee;Shin, Gun-Jin;Park, Hee-Yeoul;Um, Sang-Hyun;Kim, You-Ha
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.5
    • /
    • pp.74-80
    • /
    • 2013
  • This paper presents the transient behavior of the switching surge voltages generated by interruption of DC ground fault currents flowing through metal flexible conduits. All fault circuits consist of line parameters such as resistance, inductance, capacitance and conductance. The use of nonmagnetic metal conduits should be taken into account in order to reduce the inductance of battery charger distribution circuits. The frequency-dependent circuit parameters of metal flexible conduits were measured. The switching surge voltages generated at the ground fault circuit consisted of steel-galvanized alloy and aluminium conduits were investigated. As a result, the impedances of metal flexible conduits are significantly increased over the range of the frequency above 10 kHz and the switching surge voltages generated along aluminium flexible conduit are lower than those along steel-galvanized alloy conduit when DC fault current is interrupted.

Transient Characteristics of Sensorless Vector Control of Induction Motor using Speed Observer (속도 Observer를 이용한 유도전동기 센서리스 벡터제어의 과도특성)

  • 이수원;전칠환;이성룡
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.808-811
    • /
    • 2002
  • The stability for a speed sensorless vector control of an induction machine has been studied. These studies show that the sensorless control is apt to be more unstable than the control with sensor on the variation for stator resistance, rotor resistance and system parameters of the machine. First, this paper investigates the speed characteristics when the inertia, J, changes and the rotor resistance, R$_{r}$ changes respectively for a step change of a speed reference, $\omega$. Then, the new speed estimation algorithms with no effects on the parameters variation of the machine and the system is proposed. The proposed method is to implement the observer using voltage, current and constant of the machine. The results are verified by simulation.

  • PDF

Carrier Lifetime Analysis of Proton Irradiated SOl Wafer with Pseudo MOSFET Technology (Pseudo MOSFET 기술에 의한 양성자 조사 SOl 웨이퍼의 캐리어 수명 분석)

  • Jung, Sung-Hoon;Lee, Yong-Hyun;Lee, Jae-Sung;Kwon, Young-Kyu;Bae, Young-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.9
    • /
    • pp.732-736
    • /
    • 2009
  • Protons are irradiated into SOl wafers under total dose of 100 krad, 500 krad, 1 Mrad and 2 Mrad to analyze the irradiation effect. The electrical properties are analyzed by pseudo MOSFET technology after proton irradiation. The wafers are annealed to stabilize generated defects in a nitrogen atmosphere at $300^{\circ}C$ for 1 hour because proton irradiation induces a lot of unstable defects in the surface silicon film. Both negative and positive turn-on voltages are shifted to negative direction after the irradiation. The more proton total dose, the more turn on voltage shifts. It means that positive oxide trap charge is generated in the buried oxide(BOX). The minority carrier lifetime which is analyzed by the drain current transient characteristics decreases with the increase of proton total dose. The proton irradiation makes crystal defects in the silicon film, and consequently, the crystal defects reduce the carrier lifetime and mobility. As these results, it can be concluded that pseudo MOSFET is a useful technology for the analysis of irradiated SOI wafer.

Mixed-mode Simulation of Switching Characteristics of SiC DMOSFETs (Mixed-mode 시뮬레이션을 이용한 SiC DMOSFETs의 스위칭 특성 분석)

  • Kang, Min-Seok;Choi, Chang-Yong;Bang, Wook;Kim, Sang-Chul;Kim, Nam-Kyun;Koo, Sang-Mo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.9
    • /
    • pp.737-740
    • /
    • 2009
  • SiC power device possesses attractive features, such as high breakdown voltage, high-speed switching capability, and high temperature operation. In general, device design has a significant effect on the switching characteristics, In this paper, we demonstrated that the switching performance of DMOSFETs are dependent on the with Channel length ($L_{channel}$) and Current Spreading Layer thickness ($T_{CSL}$) by using 2-D Mixed-mode simulations. The 4H-SiC DMOSFETs with a JFET region designed to block 800 V were optimized for minimum loss by adjusting the parameters of the JFET region, CSL, and epilayer. It is found that improvement of switching speed in 4H-SiC DMOSFETs is essential to reduce the gate-source capacitance and channel resistance. Therefore, accurate modeling of the operating conditions are essential for the optimizatin of superior switching performance.

Application of Wavelet Transform for Fault Discriminant of Generator (발전기의 고장 판별을 위한 웨이브릿 변환의 적용)

  • Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.1
    • /
    • pp.35-40
    • /
    • 2015
  • Generators are the most complex and expensive single element in a power system. The generator protection relays should to minimize damage during fault states and must be designed for maximum reliability. A conventional CDR(Current Differential Relaying) technique based on DFT(Discrete Fourier Transform) filter have the disadvantages that the time information can lead to loss in the process of converting the signal from the time domain to the frequency domain. A WT(Wavelet transform) and WT analysis is known that it is possible with the local analysis of the fault and transient signal. In this paper, to overcome the defects in the DFT process, an application of WT for fault detection of generator is presented. This paper describes an selection of mother Wavelet to detect faults of generator. Using collected data from the fault simulation with ATPdraw, we analyzed the several mother Wavelet through the course of MLD(multi-level decomposition) using MATLAB software. Finally, it can be seen that the proposed technique using detail coefficient of Daubechies level 2 which can be fault discriminant of generator.

Electro-thermal Feedback Effects on the Signal in a Pulse Voltage Biased μ-bolometer Focal Plane Array (마이크로 볼로미터 초점면 배열에서 전기-열적 피드백 현상이 신호에 미치는 영향)

  • Park, Seung-Man;Han, Seungoh
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1886-1891
    • /
    • 2012
  • In this paper, the analytical models for the electrothermal feedback of a ${\mu}$-bolometer focal plane array(FPA) are proposed and applied to the conceptually designed FPA to investigate the electrothermal feedback effect on bolometer FPA signal. The temperature and resistance change of the ${\mu}$-bolometer by the electrothermal feedback(ETF) model are increased upto 20 and 35.7 % of those of no feedback case, respectively, while those by the effective thermal conductance(ETC) model increased 8.5 and 15.1 %. The integration current and output voltage of a CTIA used as an column amplifier of FPA are also increased upto 41.6 and 32.4 % by the ETF model, while increased upto 17.2 and 13.5 % by the ETC model. The proposed models give more accurate temperature change, accordingly larger signal than no feedback considering case. Electrothermal feedback effect should be considered to design a high performance and high density ${\mu}$-bolometer FPA. The proposed models are very useful to investigate the transient thermal analysis, also considered to be useful to predict the responsivity and dynamic range of ${\mu}$-bolometer FPAs.

A DSP based Three Phase Power Quality Analyzer for Motor Drives (모터 구동장치를 위한 DSP기반 3상 전력품질분석 시스템)

  • 김우용;정영국;임영철
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.1
    • /
    • pp.27-33
    • /
    • 2001
  • This paper presents a digital instrument for a DSP based power quality analysis in three phase power system where current waveform is non-sinusoidal. it is based on stand alone type TMS320C31 DSP(digital signal processor)board and on a special high-speed data acquisition system. Power quality of low power motor drives are analyzed and processed by using a simple average power algorithm, and result of power analysis are displayed by LCD in the proposed system. This paper also goes on to discuss the performance of an instrument prototype, both in terms of accuracy and speed of measurement under the transient and steady state condition.

  • PDF

Ginsenoside Rd and ischemic stroke; a short review of literatures

  • Nabavi, Seyed Fazel;Sureda, Antoni;Habtemariam, Solomon;Nabavi, Seyed Mohammad
    • Journal of Ginseng Research
    • /
    • v.39 no.4
    • /
    • pp.299-303
    • /
    • 2015
  • Panax ginseng is a well-known economic medical plant that is widely used in Chinese traditional medicine. This species contains a unique class of natural products-ginsenosides. Recent clinical and experimental studies have presented numerous lines of evidence on the promising role of ginsenosides on different diseases including neurodegenerative diseases, cardiovascular diseases, and certain types of cancer. Nowadays, most of the attention has focused on ginsenoside Rd as a neuroprotective agent to attenuate ischemic stroke damages. Some of the evidence showed that ginsenoside Rd ameliorates ischemic stroke-induced damages through the suppression of oxidative stress and inflammation. Ginsenoside Rd can prolong neural cells' survival through the upregulation of the endogenous antioxidant system, phosphoinositide-3-kinase/AKT and extracellular signal-regulated protein kinase 1/2 pathways, preservation of mitochondrial membrane potential, suppression of the nuclear factor-kappa B, transient receptor potential melastatin, acid sensing ion channels 1a, poly(ADP-ribose) polymerase-1, protein tyrosine kinase activation, as well as reduction of cytochrome c-releasing and apoptosis-inducing factor. In the current work, we review the available reports on the promising role of ginsenoside Rd on ischemic stroke. We also discuss its chemistry, source, and the molecular mechanism underlying this effect.

Effect of Ultrathin Al2O3 Layer on TiO2 Surface in CdS/CdSe Co-Sensitized Quantum Dot Solar Cells

  • Sung, Sang Do;Lim, Iseul;Kim, Myung Soo;Lee, Wan In
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.2
    • /
    • pp.411-414
    • /
    • 2013
  • In order to enhance the photovoltaic property of the CdS/CdSe co-sensitized quantum dot sensitized solar cells (QDSSCs), the surface of nanoporous $TiO_2$ photoanode was modified by ultrathin $Al_2O_3$ layer before the deposition of quantum dots (QDs). The $Al_2O_3$ layer, dip-coated by 0.10 M Al precursor solution, exhibited the optimized performance in blocking the back-reaction of the photo-injected electrons from $TiO_2$ conduction band (CB) to polysulfide electrolyte. Transient photocurrent spectra revealed that the electron lifetime (${\tau}_e$) increased significantly by introducing the ultrathin $Al_2O_3$ layer on $TiO_2$ surface, whereas the electron diffusion coefficient ($D_e$) was not varied. As a result, the $V_{oc}$ increased from 0.487 to 0.545 V, without appreciable change in short circuit current ($J_{sc}$), thus inducing the enhancement of photovoltaic conversion efficiency (${\eta}$) from 3.01% to 3.38%.

Energy Saving Potentials of Dedicated Outdoor Air System in a High-rise Apartment Building (외기전담 시스템 기반 초고층 공동주택 중앙 환기시스템의 에너지 절감효과 분석)

  • Kim, Min-Hwi;Kim, Jin-Hyo;Kwon, Oh-Hyun;Jeong, Jae-Weon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.291-296
    • /
    • 2009
  • This paper investigates the energy saving potentials of a dedicated outdoor air system (DOAS) applied to a highrise apartment building. As for a typical $132-m^2$ apartment unit, two different HVAC systems; centralized DOAS-Ceiling Radiant Cooling Panel and decentralized Energy Recovery Ventilator-Packaged Air Conditioner were installed. Transient behavior and control characteristics of each system were modeled numerically using a commercial equation solver program, and annual cooling coil load and heating load reduction potentials were compared. The research shows that DOAS-Ceiling Radiant Cooling Panel system can reduce the cooling coil load over 21% annually compared with the current Energy Recovery Ventilator-Packaged Air Conditioner pair. In addition, over 40% of annual ventilation heating load can be reduced by use of DOAS.

  • PDF