• 제목/요약/키워드: Current regulator

검색결과 342건 처리시간 0.036초

DC/DC 컨버터의 파라미터 변동에 따른 분기 특성 (Bifurcation Characteristics of DC/DC Converter with Parameter Variation)

  • 오금곤;조금배;김재민;조진섭;정삼용
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.650-654
    • /
    • 1999
  • In this paper, author describe the simulation results concerning the period doubling bifurcation route to chaos of DC/DC boost converter under current mode control to show that it is common phenomena on switching regulator when parameters are improperly chosen or continuously varied beyond the ensured region by system designer. Bifurcation diagrams of periodic orbits of inductor current and capacitor voltage of DC/DC boost converter are plotted with sampled data at moment of each clock pulse causing switching on. DC/DC boost converter studied on this paper is modelled by its state space equations as per switching condition under continuous conduction mode. Current reference signal and capacitance are chosen as the bifurcation parameters and those are varied in step for iterative calculation to find bifurcation points of periodic orbits of state variables.

  • PDF

Fault-Tolerant Control of Five-Phase Induction Motor Under Single-Phase Open

  • Kong, Wubin;Huang, Jin;Kang, Min;Li, Bingnan;Zhao, Lihang
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.899-907
    • /
    • 2014
  • This paper deals with fault-tolerant control of five-phase induction motor (IM) drives under single-phase open. By exploiting a decoupled model for five-phase IM under fault, the indirect field-oriented control ensures that electromagnetic torque oscillations are reduced by particular magnitude ratio currents. The control techniques are developed by the third harmonic current injection, in order to improve electromagnetic torque density. Furthermore, Proportional Resonant (PR) regulator is adopted to realize excellent current tracking performance in the phase frame, compared with Proportional Integral (PI) and hysteresis regulators. The analysis and experimental results confirm the validity of fault-tolerant control under single-phase open.

응답 의존형 MR 감쇠기의 성능 평가 (Performance Evaluation of Response-Dependent MR Damper)

  • 이상현;민경원;윤경조
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.511-518
    • /
    • 2006
  • In this study, seismic response mitigation effect of an MR damper generating response-dependent frictional force is investigated. It has been reported in previous studies that passively operated MR damper with constant input current doesn't show better control performance than semi-active MR damper with varying input current calculated by control algorithms such as linear quadratic regulator and sliding mode control. However, in order to operate the MR damper semi-actively, other control systems besides the damper itself such as sensors for measuring structural responses and controller for calculating optimal input current are necessary, which deteriorate the economical efficiency. This study presents a MR damper generating frictional force of which magnitude is controlled in accordance to the displacement and velocity transferred to the damper. Numerical analyses results indicate that the performance of the response dependent MR damper is closely related with the range of the friction force and it can be designed to short better control performance than the passive MR damper.

  • PDF

스마트그리드의 탭 전환 자동 전압 조정기의 다중 스위칭 제어 방법 및 활용 방안에 관한 연구 (A Study on the Utilization and Control Method of Hybrid Switching Tap Based Automatic Voltage Regulator on Smart Grid)

  • 박광윤;김정률;김병기
    • 한국컴퓨터정보학회논문지
    • /
    • 제17권12호
    • /
    • pp.31-39
    • /
    • 2012
  • 본 논문에서는 수용가의 에너지 절감과 최대수요전력 제어를 위하여 마이크로프로세서를 이용한 자동 전압 조정기(AVR)를 제안한다. 제안한 자동 전압 조정기(HS-AVR : Hybrid Switching Automatic Voltage Regulator)는 토로이달 코어에 1개의 직렬 권선과 분리된 4개의 분로 권선으로 구성되어 있는 단권변압기를 사용한다. 변압기의 전압 조정은 직렬 권선과 분로 권선의 연결 방법에 따라 감압/승압이 가능하다. 스위치는 릴레이와 트라이악을 병행하여 사용한다. 스위치의 조작 시 발생하는 권선의 여자돌입전류를 제어하기 위하여 트라이악을 이용하여 연결 상태를 변경하고, 연결 상태 유지 시에는 릴레이를 이용함으로써 스위치 소비 전력을 최소화 한다. 제어 신호는 여자 돌입 전류를 줄이기 위하여 전압 파형에 동기화 하여 제어되며 이를 위하여 소프트웨어 PLL을 사용한다. 소프트웨어 PLL은 전압 파형의 제로크로스, 전압 최고점 등의 동기화에 사용함으로써 스위치와 시스템을 최소화한다. 기존 전압 조절 스위치나 자동 전압 조정기 구조는 여자 돌입 전류로 인한 스위치 접점 손상을 막기 위하여 최대전류를 수용할 수있는 용량으로 구성함으로써 장치 크기가 매우 커지는 문제점이 있었다. 본 논문은 이런 문제를 해결하여 자동 전압 조정기의 크기를 줄이고 효율을 높이는 방법을 제안하였다.

VMS 자동제어 알고리즘 설계 (Conceptual Design of Automatic Control Algorithm for VMSs)

  • 박은미
    • 대한교통학회지
    • /
    • 제20권7호
    • /
    • pp.177-183
    • /
    • 2002
  • 현재 국내 VMS 운영은 대체로 소극적 정보제공에 머물고 있으며, 정보제공 우선순위. 조합 가능한 메시지 집합 등이 포함된 간단한 형태의 지식기반 추론엔진 방식에 의하고 있다. 또한 VMS 관련 연구도 해당도로의 상황을 정확히 검지하고 예측하는 방법론 개발에 집중되어 있다. 그러나 VMS도 적극적 운영을 통하여 교통관리의 수단으로 활용해야 하며, 이에 있는 그대로 상황을 전달하는 현 Practice에서 진일보한 전략적 정보제공 기술이 개발되어야 한다. 본 연구에서는 네트워크 차원의 교통관리를 목적으로 한 VMS 자동제어 알고리즘을 제안하였다. 외란의 불확실성과 모형의 정확도에 강한(robust) 피드백 제어방식을 채택하였고, 알고리즘은 시스템 최적 달성을 목표로 설정한 여유용량 균등화 Regulator와 VMS Display 모듈로 구성된다. 여유용량의 산정은 도로용량편람의 용량 개념과 차별화 되는 개념을 제안하였으며 이 부분에 대한 구체적 산정방식의 개발은 향후과제로 남겨두었다. 두 개의 대안경로로 구성된 실제 도로망에 대한 모의실험을 통하여. 여유용량균등화 Regulator에 의한 통행 재배분 효과를 제한적으로나마 살펴보았다. 그러나 VMS Display Strategy 모듈에 의한 실제 통행배분 행태는 모의실험의 한계성으로 인하여 검증하지 못하였으며 이를 향후과제로 남겨두었다.

Design and Torque Ripple Analysis of Brush-less DC Motor According to Delta Winding Connection

  • Lee, Tae-Yong;Seo, Myung-Ki;Kim, Yong-Jae;Jung, Sang-Yong
    • Journal of Magnetics
    • /
    • 제20권2호
    • /
    • pp.166-175
    • /
    • 2015
  • In this study, we describe the design method of a Brush-less DC (BLDC) motor with delta winding connection. After designing delta winding connection model with the $60^{\circ}$ flat-top region of the Back Electro-Motive Force (BEMF), an ideal current source analysis and a voltage source analysis, with a 6-step control, were conducted primarily employing Finite Element Method. In addition, as a current controller, we considered the Current Regulator with PI controller using Simulink for the comparison of torque characteristics. When the input current is controlled, the switching regions and reference signals are determined by means of the phase BEMF zero-crossing point. In reality, the input current variation depends on the inductance as well as input voltage, and it causes a torque ripple after all. Therefore, each control method considered in this research showed different torque ripple results. Based on the comparison, the causes of the torque ripple have been verified in detail.

스위칭 레귤레이터에 있어서 과도응답에 대한 연구 (A Study on the transient response in the switching regulator)

  • 김희준;김순창
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 추계학술대회 논문집 학회본부
    • /
    • pp.235-239
    • /
    • 1989
  • This paper investigated the effect of right half plane zero on the transient response in the buck-boost DC-DC converter. And it is clarified that the damping ratio decreases gradually by increases of the feedback loop gain and the regulation system of the converter becomes unstable. From the result, we obtained the stability region about the duty ratio and the output current by evaluating the feedback loop gain.

  • PDF

벅형 프리레귤레이터를 가진 일정주파수 직렬공진변환기를 위한 새로운 준최적제어기 설계 (A sub-optimal controller design for constant-frequency series resonant converter with buck type pre-regulator)

  • 안희욱;고정호;윤명중
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.96-100
    • /
    • 1990
  • Dynamic modelling and controller design technique for constant-frequency series resonant converter with buck type preregulator are mainly described in this paper. An equivalent circuit model is derived and a state equation is developed from this model. To improve the dynamic performance, a negative feedback of inductor current is added to the proportional and integral control of output voltage. Furthermore, an optimization technique with prescribed eigenvalue region is applied to the determination of feedback gains. With the presented design method, much better dynamic performance can be obtained.

  • PDF

주요국 설비제공대가 산정방식에 대한 사례 분석 (Case Study on Pricing Principle of Facilities Sharing and Its Implications)

  • 이종용
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2004년도 춘계종합학술대회
    • /
    • pp.565-568
    • /
    • 2004
  • Facilities Sharing is defined as the access providers who is holding the telecommunications facilities rent their facilities to the access seekers who is not holding them to promote the fair competition among carriers in a narrow sense and to avoid the duplication of investment in a broad sense. MIC, the regulator in Korea, has revised the current policy of facilities access toward mandatory system. The purpose of this paper is to review the pricing principle of facilities sharing in major countries and to discuss the implications of this case study.

  • PDF

Establishment of Analytical Method for Residues of Ethychlozate, a Plant Growth Regulator, in Brown Rice, Mandarin, Pepper, Potato, and Soybean Using HPLC/FLD

  • Kim, Jae-Young;Lee, Jin Hwan;Lee, Sang-Mok;Chae, Young-Sik;Rhee, Gyu-Seek;Chang, Moon-Ik
    • 한국환경농학회지
    • /
    • 제34권2호
    • /
    • pp.111-119
    • /
    • 2015
  • BACKGROUND: Ethychlozate (ECZ) is a plant growth regulator of synthetic auxin for agricultural commodities (ACs). Accurate and sensitive method to determine ECZ in diverse ACs on global official purpose is required to legal residue regulation. As the current official method is confined to the limited type of crops with poor validation, this study was conducted to improve and extend the ECZ method using high-performance liquid chromatography (HPLC) in all the registered crops with method verification. METHODS AND RESULTS: ECZ and its acidic metabolite (ECZA) were both extracted from acidified samples with acetone and briefly purified by dichloromethane partition. ECZ was hydrolyzed to form ECZA and the combined ECZA was finally purified by ion-associated partition including hexane-washing. The instrumental quantitation was performed using HPLC/ FLD under ion-suppression of ECZA with no interference by sample co-extractives. The average recoveries of intra- and inter-day experiment ranged from 82.0 to 105.2% and 81.7 to 102.8%, respectively. The repeatability and reproducibility for intra- and inter-day measurements expressed as a relative standard deviation was less than 8.7% and 7.4%, respectively. CONCLUSION: Established analytical method for ECZ residue in ACs was applicable to the nation-wide pesticide residues monitoring program with the acceptable level of sensitivity, repeatability and reproducibility.