Low Complexity Motion Estimation Based on Spatio - Temporal Correlations (시간적-공간적 상관성을 이용한 저 복잡도 움직임 추정)

  • Yoon Hyo-Sun;Kim Mi-Young;Lee Guee-Sang
    • Journal of KIISE:Software and Applications
    • /
    • v.31 no.9
    • /
    • pp.1142-1149
    • /
    • 2004
  • Motion Estimation(ME) has been developed to reduce temporal redundancy in digital video signals and increase data compression ratio. ME is an Important part of video encoding systems, since it can significantly affect the output quality of encoded sequences. However, ME requires high computational complexity, it is difficult to apply to real time video transmission. for this reason, motion estimation algorithms with low computational complexity are viable solutions. In this paper, we present an efficient method with low computational complexity based on spatial and temporal correlations of motion vectors. The proposed method uses temporally and spatially correlated motion information, the motion vector of the block with the same coordinate in the reference frame and the motion vectors of neighboring blocks around the current block in the current frame, to decide the search pattern and the location of search starting point adaptively. Experiments show that the image quality improvement of the proposed method over MVFAST (Motion Vector Field Adaptive Search Technique) and PMVFAST (Predictive Motion Vector Field Adaptive Search Technique) is 0.01~0.3(dB) better and the speedup improvement is about 1.12~l.33 times faster which resulted from lower computational complexity.

Design of Wideband Bow-Tie Antenna with Folded-Slit Band-Notch Structure (폴디드 슬릿 대역저지 구조를 적용한 광대역 보우타이 안테나 설계)

  • Nam, Hyun-Soo;Woo, Dong Sik;Kim, Sung-Kyun;Kim, In-Bok;Choi, Hyun-Chul;Kim, Kang Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.9
    • /
    • pp.886-894
    • /
    • 2014
  • A wideband bow-tie antenna fed by wideband microstrip-coplanar stripline(CPS) balun and band notch structures that can be applied to bow-tie antenna are proposed in this paper. In order to increase bandwidth, bow-tie radiators are reshaped so that the surface current flows continuously, and wideband impedance matching is achieved by adjusting strip width and spacing of CPS feeding line. The VSWR is measured as 2:1 over the wide frequency range of 2.3~12 GHz. The fabricated antenna size is $60mm{\times}60mm$. In order to achieve the band-notch function at WLAN(5.8 GHz), ${\lambda}/4$ folded-slits located ${\lambda}/4$ away from feeding point are utilized. To minimize the slit size, folded-slit type is adopted. The measured VSWR is 7:1 and gain attenuation is 14 dB at 5.8 GHz.

A Design of Novel Instrumentation Amplifier Using a Fully-Differential Linear OTA (완전-차동 선형 OTA를 사용한 새로운 계측 증폭기 설계)

  • Cha, Hyeong-Woo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.1
    • /
    • pp.59-67
    • /
    • 2016
  • A novel instrumentation amplifier (IA) using fully-differential linear operational transconductance amplifier (FLOTA) for electronic measurement systems with low cost, wideband, and gain control with wide range is designed. The IA consists of a FLOTA, two resistor, and an operational amplifier(op-amp). The principal of the operating is that the difference of two input voltages applied into FLOTA converts into two same difference currents, and then these current drive resistor of (+) terminal and feedback resistor of op-amp to obtain output voltage. To verify operating principal of the IA, we designed the FLOTA and realized the IA used commercial op-amp LF356. Simulation results show that the FLOTA has linearity error of 0.1% and offset current of 2.1uA at input dynamic range ${\pm}3.0V$. The IA had wide gain range from -20dB to 60dB by variation of only one resistor and -3dB frequency for the 60dB was 10MHz. The proposed IA also has merits without matching of external resistor and controllable offset voltage using the other resistor. The power dissipation of the IA is 105mW at supply voltage of ${\pm}5V$.

A Cotwin Control Study of Smoking and Risk Factors of Metabolic Syndrome

  • Sung, Jooh-On;Cho, Sung-Il;Choi, Ji-Sook;Song, Yun-Mi;Lee, Ka-Young;Choi, Eun-Young;Ha, Mi-Na;Kim, Yeon-Ju;Shin, Eun-Kyung
    • Genomics & Informatics
    • /
    • v.3 no.4
    • /
    • pp.166-171
    • /
    • 2005
  • Background: Smoking effects are relatively well-documented, especially on cancers and cardiovascular diseases. However, the direction and magnitude of association between smoking and obesity remain unclear. Conflicting results so far are thought to stem from the multiple confounding structure of smoking and other obesogenic life style characteristics. Methods: Cotwin control study is a genomic epidemiology design, in which the other twin (=cotwin) serves as a control of the twin. Cotwin control study, discordant for smoking habits can provide powerful evidence of association between smoking and obesity by completely matching genomic information, intrauterine environment, and almost all environmental factors. We selected 3,697 like-sex twin pairs (2,762 male and 935 female pairs) out of 63,666 pairs of adult twins in the existing Korea Twin and Family Register, whose smoking habits are discordant. We used the information of obesity as body mass index (BMI, $kg/m^2$) blood pressure, and blood cholesterol level at the time or later than the smoking information. Paired t-test was done to compare the smoking effects. Results: Lifetime smoking rate was 80.1 % (47.9 current smoker) for men and 10% (1.7% current smoker) for women. Among 2,762 and 935 male and female like-sex twin pairs, 363 male pairs and 20 female pairs correspond to the definition of smoker-nonsmoker pair. The male smokers demonstrated increase in BMI by 0.47, while female smokers show slight decrease (by 0.13), which were not statistically significant. Diastolic and systolic blood pressure, and cholesterol level were slightly increased among smokers by 1.85 mmHg, 0.62 mmHg, and 1.28 mg/dl for men. For women, the results show increase in diastolic blood pressure (3.42mmHg) and cholesterol level (1.25 mg/dl), and systolic pressure (8.17 mmHg). Conclusion: The results refute the possibility that smoking can reduce BMI. Considering the direct adverse effect of smoking, it should be emphasized that smoking do not decrease obesity and thus increase overall metabolic syndrome.

A Study of Analysis Current state of the Apprenticeship Curriculum in Vocational Education and Training High Schools Participating in the Apprenticeship System (산학일체형 도제학교의 도제 교육과정 편성 현황 분석 연구)

  • Ahn, Jae-Yeong
    • Journal of vocational education research
    • /
    • v.36 no.4
    • /
    • pp.57-78
    • /
    • 2017
  • This study aimed to make proposals to develop an apprenticeship program and organize the apprenticeship curriculum by conducting an overall analysis of how vocational education and training high schools participating in the apprenticeship system(apprenticeship schools) organized the apprenticeship program in the school curriculum. To that end, the study analyzed the current state of the apprenticeship curriculum of 33 apprenticeship schools and came up with the following results: First, the apprenticeship class and the general class had a similar relevance between 'departments' and 'areas and goals of student training' and between 'departments' and 'qualifications,' while the apprenticeship class had a higher relevance between 'areas and goals of student training' and 'qualifications' than the general class. Second, both the required and optional competency units of the apprenticeship program were relatively evenly included in the Off-JT and OJT. Third, the competency units of the apprentice program were included in the technical subjects of the 2009 revised curriculum as well as the NCS practical subjects of the 2015 revised curriculum. Fourth, although most of the competency units of the apprenticeship program have a high correlation with the technical subjects of the school curriculum, there were also many schools showing a low correlation. Fifth, although the hierarchy of organizing the competency units of the apprenticeship program by semester was mostly high, there were a considerable number of schools with a low hierarchy. As a result, this study made the following policy proposals: granting a grace period for approval of the changes in the curriculum of the apprenticeship, distributing the matching table before and after the revision of the NCS competency units, organizing subjects not included in the national curriculum, creating subjects specialized for companies, and monitoring and consulting the curriculum of the apprenticeship schools.

A Study on the Comparison of Korea Good Manufacturing Practice (KGMP) Evaluation Criteria with Certification Criteria of Extramural Herbal Dispensaries (원외탕전실 평가인증기준과 KGMP 평가인증 기준과의 비교연구)

  • Hyeong-Gi Kim;Eui-Hyoung Hwang;Eun-Gyeong Lee;Byung-Mook Lim;Young-Jae Shin;Sun-Young Park;Byung-Cheul Shin
    • The Korea Journal of Herbology
    • /
    • v.38 no.6
    • /
    • pp.61-71
    • /
    • 2023
  • Objectives : This study aimed to find out the future direction of accreditation system of Extramural herbal dispensaries (EHD) by comparing the current criteria of EHD and the existing Korea good manufacturing practice (GMP) regulations. Methods : Among the accreditation criteria of EHD, criteria of general herbal medicine was compared with the pharmaceutical GMP of Korea. The regulations of the accreditation of EHD and the regulations of KGMP were compared and organized with similar things based on the index of KGMP. All criteria from both were extracted for each element, classified into key-words and evaluated by dividing them into the same, similar one and no-matching. Results : Among the 189 criteria of KGMP, 77 criteria were consistent with the accreditation of EHD, and 15 criteria were similar. Based on the accreditation of EHD, 70.4% of the criteria were consistent or similar to KGMP. There were a total of 27 key-words only in the GMP criteria and not in the EHD one. Hence, a total of 25 key-words only in the EHD criteria and not in the GMP one. There were 12 similar key-words, and among them, there were 4 key-words in which accreditation of EHD was more specific than the KGMP. Conclusions : The criteria of general herbal medicine in EHD showed a similar or equivalent level of accreditation criteria compared to that of pharmaceutical GMP in Korea, and it ts believed that it should be considered at the current level to reflect the characteristics of herbal medicine.

A Study of the Adjustment and Treatment Depending on the Change of Prostate Location Using DIPS in Proton Beam Therapy for Prostate Gland in which a Fiducial Gold Marker was Inserted (Fiducial Gold Marker가 삽입된 전립선암 양성자 치료 시 Digital Image Positioning System (DIPS)을 이용한 전립선의 위치변화에 따른 보정에 관한 연구)

  • Park, June-Ki;Kim, Sun-Young;Kim, Tae-Yoon;Choi, Kye-Sook;Yeom, Doo-Suk;Kang, Dong-Yoon;Choi, Seung-O;Park, Ji-Youn
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.25-29
    • /
    • 2008
  • Purpose: To monitor the changes of location of prostate gland using DIPS and to examine the adjustment and proton beam therapy depending on the movement of prostate gland in proton beam therapy for prostate gland in which a fiducial gold marker was inserted. Materials and Methods: This study was conducted in ten patients with prostate cancer who received proton beam therapy since April of 2008. To monitor the change of prostate location, three fiducial gold markers were inserted prior to the treatment. To minimize the movement of prostate gland, patients were recommended to urinate prior to the treatment, to intake a certain amount of water and to concomitantly undergo rectal balloon. In these patients, the set-up position was identical to that for a CT-simulation. The PA (posterior-anterior) and lateral images were obtained using both DIPS (digital image positioning system) and a plain radiography, and they were compared between the two imaging modalities. Thus, the changes of the location of fiducial gold marker were assessed based on three coordinates (x, y, z) and then adjusted. This was followed by proton beam therapy. Results: Images which were taken using a plain radiography were compared with those which were taken using DIPS. In ten patients, according to a reference bony marker, the mean changes of the location of fiducial gold marker based on an iso-center were X-axis: $\pm$0.116 cm, Y-axis: $\pm$0.19 cm and Z-axis: $\pm$0.176 cm. These ten patients showed a difference in the changes of location of prostate gland and it ranged between RT: 0.04 cm and RT: 0.24 cm on the X-axis; between Inf: 0.03 cm and Sup: 0.42 cm on the Y-axis; and Post: 0.05 cm and Ant: 0.35 cm on the Z-axis. Conclusion: To minimize the movement of prostate gland, as the pre-treatment prior to the treatment. In all the patients, however, three fiducial gold markers showed a daily variation which were inserted in the prostate gland. Based on the above data, Thus, the requirement of gold marker matching system depending on the daily variation in the proton beam therapy for which more accurate establishment of target was confirmed. It is assumed that an accurate effect of proton beam therapy would be enhanced by adjusting the target-center depending on the location change of prostate gland using DIPS which was used in the current study.

  • PDF

Modelling of Fault Deformation Induced by Fluid Injection using Hydro-Mechanical Coupled 3D Particle Flow Code: DECOVALEX-2019 Task B (수리역학적연계 3차원 입자유동코드를 사용한 유체주입에 의한 단층변형 모델링: DECOVALEX-2019 Task B)

  • Yoon, Jeoung Seok;Zhou, Jian
    • Tunnel and Underground Space
    • /
    • v.30 no.4
    • /
    • pp.320-334
    • /
    • 2020
  • This study presents an application of hydro-mechanical coupled Particle Flow Code 3D (PFC3D) to simulation of fluid injection induced fault slip experiment conducted in Mont Terri Switzerland as a part of a task in an international research project DECOVALEX-2019. We also aimed as identifying the current limitations of the modelling method and issues for further development. A fluid flow algorithm was developed and implemented in a 3D pore-pipe network model in a 3D bonded particle assembly using PFC3D v5, and was applied to Mont Terri Step 2 minor fault activation experiment. The simulated results showed that the injected fluid migrates through the permeable fault zone and induces fault deformation, demonstrating a full hydro-mechanical coupled behavior. The simulated results were, however, partially matching with the field measurement. The simulated pressure build-up at the monitoring location showed linear and progressive increase, whereas the field measurement showed an abrupt increase associated with the fault slip We conclude that such difference between the modelling and the field test is due to the structure of the fault in the model which was represented as a combination of damage zone and core fractures. The modelled fault is likely larger in size than the real fault in Mont Terri site. Therefore, the modelled fault allows several path ways of fluid flow from the injection location to the pressure monitoring location, leading to smooth pressure build-up at the monitoring location while the injection pressure increases, and an early start of pressure decay even before the injection pressure reaches the maximum. We also conclude that the clay filling in the real fault could have acted as a fluid barrier which may have resulted in formation of fluid over-pressurization locally in the fault. Unlike the pressure result, the simulated fault deformations were matching with the field measurements. A better way of modelling a heterogeneous clay-filled fault structure with a narrow zone should be studied further to improve the applicability of the modelling method to fluid injection induced fault activation.

Actual Condition of Quality Control of X-ray Imaging System in Primary Care Institution: focused on Gwangju Metropolitan City (1차 의료기관의 엑스선 발생장치 정도관리에 관한 현황조사:광주광역시 지역을 중심으로)

  • Dong, Kyung-Rae;Lee, Seun-Joo;Kweon, Dae-Cheol;Goo, Eun-Hoe;Jung, Jae-Eun;Lee, Kyu-Su
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.34-42
    • /
    • 2010
  • With the expanded use of radiation in modern medical practices, the most important issue in regards to efforts to reduce individual exposure dose is quality assurance. Therefore in order to study the present condition of quality assurance, the Gwangju Metropolitan City area was divided into five districts each containing ten hospitals. Four experiments were conducted: a reproducibility experiment for kVp, mA, and examination time (sec) intensity of illumination; half-value layer (HVL) measurement; and beam perpendicularity test matching experiment. The tube voltage reproducibility experiment for all fifty hospitals resulted in a 95.33% passing rate and mA and examination time both resulted in a 77.0% passing rate. The passing rate for intensity of illumination was 86.0% and 52.0% for HVL, which was the lowest passing rate of all four factors. For the beam perpendicularity test matching experiment, generally the central flux is matched to within $1.5^{\circ}$. Of all fifty hospitals 30.0% were beyond $3^{\circ}$. The results of the survey showed that 58% responded that they knew about quality assurance cycle. All fifty respondents stated that they have not received any training in regards to quality assurance at their current place of employment. Although quality assurance is making relative progress, the most urgent issue is awareness of the importance of quality assurance. Therefore, the implementation of professional training focusing on safety management and accurate quality assurance of radiation will reduce the exposure to radiation for radiologists and patients and higher quality imaging using less dosage will also be possible.

Analysis of Acquisition Parameters That Caused Artifacts in Four-dimensional (4D) CT Images of Targets Undergoing Regular Motion (표적이 규칙적으로 움직일 때 생기는 4DCT 영상의 모션 아티팩트(Motion Artifact) 관련된 원인분석)

  • Sheen, Heesoon;Han, Youngyih;Shin, Eunhyuk
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.243-252
    • /
    • 2013
  • The aim of this study was to clarify the impacts of acquisition parameters on artifacts in four-dimensional computed tomography (4D CT) images, such as the partial volume effect (PVE), partial projection effect (PPE), and mis-matching of initial motion phases between adjacent beds (MMimph) in cine mode scanning. A thoracic phantom and two cylindrical phantoms (2 cm diameter and heights of 0.5 cm for No.1 and 10 cm for No.2) were scanned using 4D CT. For the thoracic phantom, acquisition was started automatically in the first scan with 5 sec and 8 sec of gantry rotation, thereby allowing a different phase at the initial projection of each bed. In the second scan, the initial projection at each bed was manually synchronized with the inhalation phase to minimize the MMimph. The third scan was intentionally un-synchronized with the inhalation phase. In the cylindrical phantom scan, one bed (2 cm) and three beds (6 cm) were used for 2 and 6 sec motion periods. Measured target volume to true volume ratios (MsTrueV) were computed. The relationships among MMimph, MsTrueV, and velocity were investigated. In the thoracic phantom, shorter gantry rotation provided more precise volume and was highly correlated with velocity when MMimph was minimal. MMimph reduced the correlation. For moving cylinder No. 1, MsTrueV was correlated with velocity, but the larger MMimph for 2 sec of motion removed the correlation. The volume of No. 2 was similar to the static volume due to the small PVE, PPE, and MMimph. Smaller target velocity and faster gantry rotation resulted in a more accurate volume description. The MMimph was the main parameter weakening the correlation between MsTrueV and velocity. Without reducing the MMimph, controlling target velocity and gantry rotation will not guarantee accurate image presentation given current 4D CT technology.