• 제목/요약/키워드: Current design method

검색결과 3,338건 처리시간 0.037초

Controller Design for a Quick Charger System Suitable for Electric Vehicles

  • Jeong, Hae-Gwang;Lee, Kyo-Beum
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권5호
    • /
    • pp.1122-1130
    • /
    • 2013
  • This paper proposes a new design for quick battery charger systems for electric vehicles that consists of a three-phase inverter and a full-bridge converter which use the phase-shift method. The 3-phase inverter controls the input and DC-link voltage by use of a current controller and a voltage controller. The full-bridge converter transfers the DC-link voltage to a fixed output voltage. Designs for the output-side converter and controller for improved performance are proposed in this paper. Design schemes for the filter and controller of an input-side inverter are also presented. Furthermore, the paper proposes a compensation method for the offset current that is caused by switch failure and circuit problems. Simulations and experiments have been performed on a 50kW-battery charger system that is suitable for vehicles. The presented results verify the validity of the proposed method and the superiority of the system over conventional methods.

판해석을 통한 교대날개벽 단면력 산정 및 설계 개선에 관한 연구 (Sectional Force and Design Improvement of Abutment Wing based on Plate Analysis)

  • 김민호;정원석;안주옥;최혁진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2010년도 춘계 학술대회 제22권1호
    • /
    • pp.175-176
    • /
    • 2010
  • 국내 도로교설계기준에서는 날개벽 길이가 8m 미만인 경우에 대해서 날개벽을 4개 구역으로 나누고 캔틸레버 구조로 간편하게 수계산하여 단면력을 산정하도록 하는 간편법을 제시하고 있다. 이러한 간편법은 수계산에 의존하던 때에 만들어진 규정으로 과도한 안전율을 고려하게 되어 경제성 면에서도 불리한 설계가 이루어지고 있다. 따라서 본 연구에서는 불합리한 교대 날개벽 관련 도로교설계기준을 개선하기 위해서, 날개벽을 2변 고정 판구조로 해석하고 시방서 단면력과 비교검토를 실시하여 현시방서의 문제점을 정량화하고 개선책을 제시하였다.

  • PDF

LD-FM 회로모델을 이용한 광 FSK 송신기 설계 (Design of Optical FSK Transmitter Using LD-FM Circuit Model)

  • 소준호;박상영;이규송;임호근;김성환;홍완혜
    • 대한전자공학회논문지
    • /
    • 제27권4호
    • /
    • pp.612-619
    • /
    • 1990
  • In this paper, a design method of optical FSK transmitter is described using LD-FM circuit model. In the design of optical FSK transmitter, an optimum bias current was chosen using LD-FM circuit model, and an unequalized FM transfer function was determined at this current. The equalizers that can make this transfer function uniform were designed by use of a simple passive network. For the designed optical FSK transmitter, the pulse-transient and small-signal frequency-deviation responses were simulated and discussed.

  • PDF

Design and Analysis of Current Mode Low Temperature Polysilicon TFT Inverter/Buffer

  • Lee, Joon-Chang;Jeong, Ju-Young
    • Journal of Information Display
    • /
    • 제6권4호
    • /
    • pp.11-15
    • /
    • 2005
  • We propose a current mode logic circuit design method for LTPS TFT for enhancing circuit operating speed. Current mode inverter/buffers with passive resistive load had been designed and fabricated. Measurement results indicated that the smaller logic swing of the current mode allowed significantly faster operation than the static CMOS. In order to reduce the chip size, both all pTFT and all nTFT active load current mode inverter/buffer had been designed and analyzed by HSPICE simulation. Even though the active load current mode circuits were inferior to the passive load circuits, it was superior to static CMOS gates.

목구조 설계를 위한 확정론적 구조 설계법과 확률 기반 구조 설계법의 비교 연구 (Methods for wooden structural design- A comparative research between deterministic design and probability based design)

  • 박문재;김광철
    • 한국가구학회지
    • /
    • 제20권4호
    • /
    • pp.358-373
    • /
    • 2009
  • Probability based design(PBD)method has some advantages against current design methods. First, it can provide the quantitative values for the structural safety or capacity through the reliability index, $^{\beta}$. That presented the certainty on the corresponding structure for the designer or user, also that permitted the broad consideration in the safety of structures. In addition, it can give the quantitative lifetime of the related structure in the calculation process of target reliability index. Also, incidental economical efficiency can be expected because decrease of required structural material can be obtained by using the practical material data. Unlikely current deterministic structural design methods, main advantage is the reflection of real condition in the structural design process by application of the data with not small clear specimen but structural size material. Advanced countries, namely America, Canada, Europe, Australia and New Zealand already converted from allowable stress design(ASD) method to PBD method and used as a standard wooden structures code in the late 1980s and 1990s. Other domestic constructions standards such as the steel or concrete constructions accepted and used the PBD methods already. Accordingly, wooden structural design method also should be converted from deterministic ASD to probabilistic LRFD(Load and resistance factor design) in order to keep pace with worldwide demands for PBD. Hence, to suggest the reason of introduction the PBD in domestic wooden structural design and analysis, a brief example was used to show the different reliability index by using the different design methods. Definition, merits and demerits of deterministic ASD and probabilistic LRFD were followed. Also the three examples were presented to show the similarity and differences between ASD and LRFD. Finally, connection problems that might cause a disputation in wooden structural design and analysis were broadly examined.

  • PDF

자연대류를 고려한 전류도입선의 최적설계 (Optimal design of Current lead considering Natural convection)

  • 손봉준;설승윤
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.103-108
    • /
    • 2003
  • In this paper, the current lead for superconducting device is studied by numerical method. The current lead is cooled by surrounded $N_{2}$ gas by natural convection. The heat conduction equation for current lead and boundary layer equation for $N_{2}$ gas must be solved simultaneously. The boundary layer equation for $N_{2}$ gas is highly nonlinear for varied temperature of current lead. So the linearization method is adopted for simplicity. Numerical results using natural convection cooling are compared with the conventional cooling methods such as conduction cooling and vapor cooling methods. The main difference of natural convection cooing is the non-zero temperature gradient at the top of current lead for the minimum heat dissipation into superconducting devices. For the optimized conduction-cooling and vapor-cooling current leads, the temperature gradient at the top of current lead is zero. Also, the heat flow at the cold end is much smaller than conduction cooling case.

  • PDF

Improved Droop Method for Converter Parallel Operation in Large-Screen LCD TV Applications

  • Kim, Jung-Won;Jang, Paul
    • Journal of Power Electronics
    • /
    • 제14권1호
    • /
    • pp.22-29
    • /
    • 2014
  • Current sharing between modules in a converter parallel operation is very important for the reliability of the system. This paper proposes an improved droop method that can effectively improve current sharing accuracy. The proposed method adaptively adjusts the output voltage set-point of each module according to the current set-points. Unlike conventional droop control, modules share a signal line to communicate with each other. Nevertheless, since signals are simple and in digital form, the complexity of the circuitry is much less and noise immunity is much better than those of conventional methods utilizing communication. The operation principle and design procedure of the proposed method are described in detail. Results of the experiment on two boost converters operating in parallel under the specification of a TFT LCD TV panel power supply verify the validity of the proposed scheme.

Development of Pareto strategy multi-objective function method for the optimum design of ship structures

  • Na, Seung-Soo;Karr, Dale G.
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제8권6호
    • /
    • pp.602-614
    • /
    • 2016
  • It is necessary to develop an efficient optimization technique to perform optimum designs which have given design spaces, discrete design values and several design goals. As optimization techniques, direct search method and stochastic search method are widely used in designing of ship structures. The merit of the direct search method is to search the optimum points rapidly by considering the search direction, step size and convergence limit. And the merit of the stochastic search method is to obtain the global optimum points well by spreading points randomly entire the design spaces. In this paper, Pareto Strategy (PS) multi-objective function method is developed by considering the search direction based on Pareto optimal points, the step size, the convergence limit and the random number generation. The success points between just before and current Pareto optimal points are considered. PS method can also apply to the single objective function problems, and can consider the discrete design variables such as plate thickness, longitudinal space, web height and web space. The optimum design results are compared with existing Random Search (RS) multi-objective function method and Evolutionary Strategy (ES) multi-objective function method by performing the optimum designs of double bottom structure and double hull tanker which have discrete design values. Its superiority and effectiveness are shown by comparing the optimum results with those of RS method and ES method.

22.9kV 배전선로 적용을 위한 DVR의 새로운 외란검출 기법 및 제어시스템 설계 (The New Voltage Event Detection Method and Control System Design for DVR Applied to 22.9kV Distribution System)

  • 김희중;정용호;권기현;박태범;문전일;전영수
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권1호
    • /
    • pp.7-12
    • /
    • 2006
  • This paper proposes the new voltage event detection method using the weight factor of neural network and describes control system design for the DVR(Dynamic Voltage Restorer) consisted of a rectifier and series inverter applied to 22.9kV distribution system. As this method can express the fault level of each phase, we expect the proposed method can make up for disadvantage of synchronous detection method. Also, in this paper, the control system was designed using double deadbeat controller, As it has an inner current control loop and an outer voltage control loop, we can easily limit the current level during the transient intervals by using the current control loop. Simulation and experiment are performed to prove the analysis of the voltage event detection method and double deadbeat controller.

Direct Current Control Method Based On One Cycle Controller for Double-Frequency Buck Converters

  • Luo, Quanming;Zhi, Shubo;Lu, Weiguo;Zhou, Luowei
    • Journal of Power Electronics
    • /
    • 제12권3호
    • /
    • pp.410-417
    • /
    • 2012
  • In this paper, a direct current control method based on a one-cycle controller (DCOCC) for double frequency buck converters (DF buck) is proposed. This control method can make the average current through the high frequency and low frequency inductors of a DF buck converter equal. This is similar to the average current control method. However, the design of the loop compensator is much easier when compared with the average current control. Since the average current though the high frequency and low frequency inductors is equivalent, the current stress of the high frequency switches and the switch losses are minimized. Therefore, the efficiency of the DF buck converter is improved. Firstly, the operation principle of DCOCC is described, then the small signal models of a one cycle controller and a DF buck converter are presented based on the state space average method. Eventually, a system block diagram of the DCOCC controlled DF buck is established and the compensator is designed. Finally, simulation and experiment results are given to verify the correction of the theory analysis.