• Title/Summary/Keyword: Current Range Extension

Search Result 64, Processing Time 0.031 seconds

Morphing Wing Mechanism Using an SMA Wire Actuator

  • Kang, Woo-Ram;Kim, Eun-Ho;Jeong, Min-Soo;Lee, In;Ahn, Seok-Min
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.13 no.1
    • /
    • pp.58-63
    • /
    • 2012
  • In general, a conventional flap on an aircraft wing can reduce the aerodynamic efficiency due to geometric discontinuity. On the other hand, the aerodynamic performance can be improved by using a shape-morphing wing instead of a separate flap. In this research, a new flap morphing mechanism that can change the wing shape smoothly was devised to prevent aerodynamic losses. Moreover, a prototype wing was fabricated to demonstrate the morphing mechanism. A shape memory alloy (SMA) wire actuator was used for the morphing wing. The specific current range was measured to control the SMA actuator. The deflection angles at the trailing edge were also measured while various currents were applied to the SMA actuator. The trailing edge of the wing changed smoothly when the current was applied. Moreover, the deflection angle also increased as the current increased. The maximum frequency level was around 0.1 Hz. The aerodynamic performance of the deformed airfoil by the SMA wire was analyzed by using the commercial program GAMBIT and FLUENT. The results were compared with the results of an undeformed wing. It was demonstrated that the morphing mechanism changes the wing shape smoothly without the extension of the wing skin.

Efficacy and Safety of Micro Current Tape on Chronic Low Back Pain: One Group Pre-Post Test Design, Multi Center Pilot Study (만성 요통 통증 완화에 대한 미세전류 테이프의 안전성 및 유효성 평가)

  • Park, Hyun-Gun;Kim, Jong-Yeon;Yi, Woon-Sup;Lee, Sin-Ji;Chung, Won-Suk;Kim, Ho-Jun;Lee, Jong-Soo
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.23 no.4
    • /
    • pp.185-194
    • /
    • 2013
  • Objectives The aim of this study was to evaluate the efficacy and safety of micro current taping therapy (MTT) on patients with chronic low back pain (CLBP). Methods We included 50 participants who met the inclusion criteria and 5 participants dropped out during the sessions due to the following reasons: 3 participants were personal reasons, 1 participant was taking medication, 1 participant was fore arm fracture. We attached "I" shaped 40 cm, 2 tapes along the erector muscles of the spine starting from both iliac crest and another "I" shaped 30 cm, 1 tape on the painful site horizontally. This procedure was done 8 times and participants visited a total of 9 times including a final visit for evaluation. We measured visual analog scale (VAS), range of motion (ROM) and schober's test on every visit. Participants completed a questionnaire of oswestry disability index (ODI) and Beck's depression inventory (BDI) on the first and last visits. Results In VAS for pain intensity and bothersomeness, there were significant decreases after 1st, 6th treatments. In range of extension, there was significant increase after 3rd treatment at first. In range of flexion, there was significant increase after 2nd treatment at first. In range of left flexion, there was significant increase after 4th treatment at first. In range of right flexion, there was significant increase after 3rd treatment at first. in schober's test, there was significant increase after 2nd treatment at first. In VAS, ROM, schober's test, BDI, ODI, there were significant improvement after all treatments had done. Conclusions There was a significant effect of MTT on CLBP. And there was no adverse effect.

The Effects of IFC and Ultrasound on the ROM and Pain in Patients with Chronic Back Pain (간섭전류와 초음파가 만성 배근 통증을 가진 환자의 통증과 관절가동범위에 미치는 영향)

  • Park, Jung-Seo;Lee, Jeong-Woo;Lee, Ji-Yeun
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.9 no.1
    • /
    • pp.23-28
    • /
    • 2011
  • Purpose : The purpose of study was to better understand the effects of Interferential Current (IFC) and Ultrasound on the ROM and pain in patients with chronic back muscle pain. Methods : Twenty patients with chronic back pain were randomly assigned to IFC stimulation groups and Ultrasound stimulation groups. Both groups used the same method for 20 minutes each session, three times a week for 4 weeks at the same time point and with the same amount of treatment. Measurement items are visual analogue scale (VAS) and range of motion (ROM). Results : This study showed that the IFC stimulation group and the ultrasound stimulation group demonstrated significant improvement in ROM increase and pain reduction. Both groups showed a significant reduction in VAS; however, the ultrasound stimulation group decreased more than ultrasound stimulation group. And, both groups showed a significant increase in ROM. The ultrasound stimulation group increased significantly more than the IFC stimulation group in ROM of flexion and extension. The IFC stimulation group increased significantly more than the ultrasound stimulation group in ROM of lateral flexion. Conclusion : Pain relief was more effective in the ultrasound group. The ultrasound showed a more significant effect than IFC in ROM of flexion and extension. The IFC showed a more significant effect than ultrasound in ROM lateral flexion. The results of this study suggest that the treatment effects are different on patients with chronic back pain, according to treatment methods.

Design of UWB CMOS Low Noise Amplifier Using Inductor Peaking Technique (인덕터 피킹기법을 이용한 초광대역 CMOS 저잡음 증폭기 설계)

  • Sung, Young-Kyu;Yoon, Kyung-Sik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.1
    • /
    • pp.158-165
    • /
    • 2013
  • In this paper, a new circuit topology of an ultra-wideband (UWB) 3.1-10.6GHz CMOS low noise amplifier is presented. The proposed UWB low noise amplifier is designed utilizing RC feedback and LC filter networks which can provide good input impedance matching. In this design, the current-reused topology is adopted to reduce the power consumption and the inductor-peaking technique is applied for the purpose of bandwidth extension. The performance results of this UWB low noise amplifier simulated in $0.18-{\mu}m$ CMOS process technology exhibit a power gain of 14-14.9dB, an input matching of better than -10.8dB, gain flatness of 0.9dB, and a noise figure of 2.7-3.3dB in the frequency range of 3.1-10.6GHz. In addition, the input IP3 is -5dBm and the power consumption is 12.5mW.

A Design Evaluation of Strained Si-SiGe on Insulator (SSOI) Based Sub-50 nm nMOSFETs

  • Nawaz, Muhammad;Ostling, Mikael
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.5 no.2
    • /
    • pp.136-147
    • /
    • 2005
  • A theoretical design evaluation based on a hydrodynamic transport simulation of strained Si-SiGe on insulator (SSOI) type nMOSFETs is reported. Although, the net performance improvement is quite limited by the short channel effects, simulation results clearly show that the strained Si-SiGe type nMOSFETs are well-suited for gate lengths down to 20 nm. Simulation results show that the improvement in the transconductance with decreasing gate length is limited by the long-range Coulomb scattering. An influence of lateral and vertical diffusion of shallow dopants in the source/drain extension regions on the device performance (i.e., threshold voltage shift, subthreshold slope, current drivability and transconductance) is quantitatively assessed. An optimum layer thickness ($t_{si}$ of 5 and $t_{sg}$ of 10 nm) with shallow Junction depth (5-10 nm) and controlled lateral diffusion with steep doping gradient is needed to realize the sub-50 nm gate strained Si-SiGe type nMOSFETs.

Mean Flow and Variability at the Upper Portion of the East Sea Proper Water in the southwestern East Sea with APEX Floats

  • Lee, Ho-Man;Kim, Tae-Hee;Kim, Ju-Ho;Youn, Yong-Hoon
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.145-150
    • /
    • 2003
  • 16 APEX floats, autonomous profiling floats deployed as part of the Array for Real-time Geostrophic Oceanography (ARGO) program, are used to understand the currents at 800 m underwater in the southwestern East Sea. The flow penetrates into the Ulleung basin (UB) through two paths: an extension of the southward flowing the North Korean Cold Water along the east coast of Korea and between Ulleung Island and Dok island. Flows at 800 m are observed range 0.2 to 4.29 cm/sec and the variability in the north in the DB is stronger than that in the south. The eddy kinetic energy is found a few $cm^{2}$ $S^{-2}$. In the UB, cyclonic flows from 0.3 - 1.6 cm/see are observed with the bottom topography.

  • PDF

3D Deinterlacing Algorithm Based on Wide Sparse Vector Correlations

  • Kim, Yeong-Taeg
    • Journal of Broadcast Engineering
    • /
    • v.1 no.1
    • /
    • pp.44-54
    • /
    • 1996
  • In this paper, we propose a new 3-D deinterlacing algorithm based on wide sparse vector correlations and a vertical edge based motion detection algorithm. which is an extension of the deinterlacing algorithm proposed in [10. llJ by the authors. The prooised algorithm is developed mainly for the format conversion problem encountered in current HDTV system, but can also be aplicable to the double scan conversion problesm frequently encountered in ths NTSC systems. By exploiting the edge oriented spatial interpolation based on the wide vector correlations, visually annoying artifiacts caused by interlacing such as a serrate line. line crawling, a line flicker, and a large area flicker can be remarkably reduced since the use of the wide vectors increases the range of the edge orientations that can be detected, and by exploiting sparse vectors correlations the HjW complexity for realizing the algorithm in applications cam be significantly simplified. Simulations are provided indicating thet the proposed algorithm results in a high performance comparable to the performance of the deinterlacing algorithm. based on the wide vector correlations.

  • PDF

Development of Quantitative Diagnostic Technique for Low-Back Pain Patients via Three Dimensional Dynamic Motion Analysis (3차원 동작분석에 의한 요통환자의 정량적 진단기법 개발에 관한 연구)

  • Kim, Jeong-Ryong
    • Journal of the Ergonomics Society of Korea
    • /
    • v.17 no.2
    • /
    • pp.11-23
    • /
    • 1998
  • Dynamic motion difference between normal subjects and low-back pain (LBP) patients has been investigated in terms of kinematic variables such as range of motion, velocity and acceleration of the back and hip. Ten healthy subjects and ten LBP patients were recruited in this study. Electro-goniometer such as Lumbar Motion Monitor and Hip Monitor have been used for quantitative measurement of the trunk motion during repetitive flexion and extension for ten seconds. Results indicated that the velocity and acceleration of the back and hip were important parameters to quantitatively identify LBP patients. The consistency of cyclic trunk motion and the relationship between the back and hip were measured in terms of Variance Ratio and Phase Angle in order to accurately assess the motion characteristics of LBP patients. In particular, the hip motion has been proven to be a very important factor in describing the kinematics of damaged lower back. The functional evaluation technique suggested in this study will be a tool to assist physicians for an accurate diagnosis and timely rehabilitation along with current image diagnosis techniques.

  • PDF

Experimental Study of Large-amplitude Wavefront Correction in Free-space Coherent Optical Communication

  • Guo, Qian;Cheng, Shuang;Ke, Xizheng
    • Current Optics and Photonics
    • /
    • v.5 no.6
    • /
    • pp.627-640
    • /
    • 2021
  • In a free-space coherent optical communication system, wavefront distortion is frequently beyond the correction range of the adaptive-optics system after the laser has propagated through the atmospheric turbulence. A method of residual wavefront correction is proposed, to improve the quality of coherent optical communication in free space. The relationship between the wavefront phase expanded by Zernike polynomials and the mixing efficiency is derived analytically. The influence of Zernike-polynomial distortion on the bit-error rate (BER) of a phase-modulation system is analyzed. From the theoretical analysis, the BER of the system changes periodically, due to the periodic extension of wavefront distortion. Experimental results show that the BER after correction is reduced from 10-1 to 10-4; however, when the closed-loop control algorithm with residual correction is used, the experimental results show that the BER is reduced from 10-1 to 10-7.

A Study on the Micro Stepping Drive to reduce Vibration of Step motor (스텝모터의 진동 저감을 위한 마이크로 스텝 구동에 관한 연구)

  • 신규범;이정우;오준호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.448-455
    • /
    • 1996
  • In this study, to reduce vibration of step motor we use Microstep control. Microstep control of stepmotor is usually thought of as an extension of conventional stepmotor control technology. The essence ofmicro stepping is that we divide the full step of a stepmotor into a number of substep called microstep and cause the stepmotor to move through a substep per input pulse. In ideal case, bycontrolling the individual phase currents of a two-phase step motor sinusoidally we can get uniform torque and step angles. But due to the monlinear characteristics of the step motor, we need to compensate current waveform to improve the overall smoothness of the conventional micro stepping system. We implement digital Pulse Width Modulation(PWM) driver to drive step motor and microphone was used for detecting vibration. Driver enables speed change automatically byincreasing or decreasing micro stepping ratio which we call Automatic Switching on the Fly. To compensate the torque harmonics, Neural Networks is applied to the system and we foundcompensated optimal input current waveform. Finally we can get smooth motion of step motor in a wide range of motor speed.

  • PDF