• 제목/요약/키워드: Current Mode Control

검색결과 1,001건 처리시간 0.036초

인버터 아크 용접기의 단락이행성능 개선을 위한 순시 출력전류제어에 관한 연구 (A Study on Instantaneous Output Current Control for Short-Circuit Mode Improvement of Inverter Arc Welding Machine)

  • 채영민;고재석;구자열;목형수;최규하;김희진
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권5호
    • /
    • pp.257-263
    • /
    • 1999
  • Recently the performance of CO2 arc welding machine has been advanced significantly through the adoption of inverter circuit topology which made it possible to control the waveform of welding current and thus to suppress the spatter generation. However, the optimum waveform is still uncertain. As a first step for figuring out the promising waveforms, this study was performed to set-up the experimental system for studying the effect of waveform variables, The system designed in this study is a digital controller using single chip microprocessor of 80C196KC. As a result of performance test of this system, it was demonstrated all of the waveform variables could be set individually and the resultant waveforms appeared to be pretty much the same as the intended one.

  • PDF

계통 사고 발생시 전압 변동을 최소화 하기위한 계통연계형 PCS의 제어 기법 (Control of Grid Connected Type PCS to Minimize Voltage Disturbance at Line Fault)

  • 정재헌;권창근;노의철;김인동;김흥근;전태원
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 추계학술대회
    • /
    • pp.257-258
    • /
    • 2011
  • This paper describes a new method for the seamless operation mode transfer of a PCS with minimized voltage disturbance. The proposed method provides reduced STS turn off time after line fault and smooth mode change between current and voltage control of the PCS. The usefulness of the method is verified through simulations with the consideration of the time delay in detecting a line fault and SCR turn-off time.

  • PDF

가변 출력 영전압 스위칭 PWM 컨버터에 관한 연구 (A study on ZVS-PWM Converter with Variable Output)

  • 김영재;임상언;김희준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.364-368
    • /
    • 1999
  • This paper suggests switching regulator technique to overcome the drawback of conventional variable linear power supply. Switching regulator technique can eliminate the extremely lossy operation and reduce the size and weight of variable linear power supply and provide nearly constant output power over the majority of output voltage range. The topology of variable switched mode power supply is employed active clamp forward converter with a current doubler rectifier and by using control of variable-frequency together with control of fixed-frequency, output voltage can be controled. Equivalent circuits pertinent to each operational mode of converter are derived, and an experimental 20V, 50A converter was designed and built. The converter operates from an output voltage of zero to 25 V, under 100 kHz switching frequency.

  • PDF

Experimental Verification of Transverse Electric Mode Controlled Vacuum Chamber of PLS-II Storage Ring

  • 주영도;하태균
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.229-229
    • /
    • 2012
  • It is significant issue to control the unwanted transverse electric (TE) modes in the vacuum chamber for preventing the position reading noise from the beam position monitor (BPM) of storage ring. We introduce shunt structure to control the frequency distribution of TE resonance modes excited in the vacuum chambers of the Pohang Light Source II (PLS-II). The design of shunt structure is performed using the full three dimensional finite-difference time-domain (FDTD) simulation. It is verified that the sympton of the BPM noise is not oberved up to the beam current of 190 mA in the commmissioning of PLS-II.

  • PDF

Performance Analysis of a Sliding Mode Control for Distributed Generations

  • Islam, Gazi;Al-Durra, Ahmed;Muyeen, S.M.;Caruna, Cedric;Tamura, Junji
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권1호
    • /
    • pp.98-104
    • /
    • 2014
  • This paper presents the performance analysis of a sliding mode based hybrid controller for three phase voltage source inverter. The main objective of this analysis is to observe the effectiveness of the controller for fault ride through (FRT) capability improvement of the distributed generations (DG). The performance of the conventional PI based cascaded controller is also presented for comparison purpose.

슬라이딩 모드 축차 관측기를 이용한 유도 전동기 속도추정 (A Rotor Speed Estimation of Induction Motors Using Sliding Mode Cascade Observer)

  • 김응석
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권3호
    • /
    • pp.145-153
    • /
    • 2004
  • A nonlinear adaptive speed observer is designed for the sensorless control of induction motors. In order to design the speed observer, the measurements of the stator currents and the estimates of the rotor fluxes are used. The sliding mode cascade observer is designed to estimate the time derivatives of the stator currents. The open-loop observer is designed to estimate the rotor fluxes and its time derivatives using the stator current derivatives. The adaptive observer is also designed to estimate the rotor resistance. Sequentially, the rotor speed is calculated using these estimated values. It is shown that the estimation errors of the corresponding states and the parameters converge to the specified residual set. It is also shown that the speed controller using these estimates is performed well. The simulation examples are represented to investigate the validity of the proposed observers for the sensorless control of induction motors.

Rapid Dynamic Response Flyback AC-DC Converter Design

  • Chang, Changyuan;Wu, Menglin;He, Luyang;Zhao, Dadi
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1627-1633
    • /
    • 2018
  • A constant voltage AC-DC converter based on digital assistant technology is proposed in this paper, which has rapid dynamic response capability. The converter operates in the PFM (Pulse Frequency Modulation) mode. According to the load state, the compensation current produced by the digital compensation module was injected into the CS pin to adjust the switching pulse width dynamically and improve the dynamic response. The control chip is implemented based on NEC $1{\mu}m$ 5V/40V HVCMOS process. A 5V/1.2A prototype has been built to verify the proposed control method. When the load jumps from idle to heavy, the undershoot time is only 7.4ms.

전류불연속 모드 절연형 벅-부스트 컨버터에 관한 연구 (A Study on Isolated Buck-Boost Converter by Discontinuous Conduction Mode)

  • 곽동걸;이봉섭;김춘삼;심재선;박영직
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 추계학술대회
    • /
    • pp.173-174
    • /
    • 2010
  • In this paper, authors propose a new buck-boost converter of discontinuous conduction mode (DCM) added electric isolation. The proposed converter with DCM eliminates the complicated circuit control requirement and reduces the size of components. The general converters of high efficiency are made that the power loss of the used switching devices is minimized. To achieve the soft switching operation of the used control switches, the proposed converter uses a lossless snubber capacitor. The proposed converter achieves the soft-switching for all switching devices without increasing their voltage and current stresses. The result is that the switching loss is very low and the efficiency of converter is high. The soft switching operation of the proposed converter is verified by digital simulation and experimental results.

  • PDF

직류 대체에너지 활용을 위한 Z-원 인버터 제어 (The Control of Z-Source Inverter for using DC Renewable Energy)

  • 박영산;배철오;남택근
    • 해양환경안전학회지
    • /
    • 제13권2호
    • /
    • pp.169-172
    • /
    • 2007
  • 본 논문은 Z-형 컨버터와 수정된 공간벡터 PWM인버터로 구성된 분산전원시스템의 회로모델과 제어 알고리즘을 보여주고 있다. Z-형 컨버터는 수동소자인 L과 C로 간단히 구성되어 있으며 인버터의 상하 양 소자가가 동시에 도통되도록 하는 구간을 이용해 승압을 함으로써 기존의 DC/DC 변환기와는 다른 형태를 취하고 있다. 점근 관측기를 이용한 이산시간 슬라이딩모드제어를 통해 전류제어를 함으로써 센서수를 줄이고 제어성능을 개선하였다. 대체에너지로 관심이 많은 태양광이나, 연료전지 그리고 소형 풍력발전으로부터 생산된 직류 에너지를 상용으로 사용할 수 있도록 하는 전력변환기로써 유용하게 사용될 수 있을 것이다.

  • PDF

6 직렬 연결된 ITER VS 컨버터의 시퀀스제어 비교 해석 (Comparative Analysis of Sequence Control in Six Series-Connected ITER VS Converters)

  • 조현식;정진용;조종민;차한주
    • 전력전자학회논문지
    • /
    • 제19권5호
    • /
    • pp.399-406
    • /
    • 2014
  • This study investigates the structure and operation of the ITER VS converter and proposes a sequence control method for six series-connected VS converters to reduce reactive power. The operation and the proposed sequence control method are verified through RTDS simulation. The ITER VS converter must supply voltage/current to the superconducting magnets for plasma current vertical stabilization, and the four-quadrant operation must proceed without a zero-current discontinuous section. The operation mode of the VS converter is separated into a 12- and 6-pulse circulating current and transition modes according to the size of the load current. The output voltage of the unit VS converter is limited because of the rated voltage; however, the superconducting coil must increase the operating output voltage. Thus, the VS converter must be connected in a 6-series to provide the required operating output voltage. The output voltage of the VS converters is controlled continuously; however, reactive power is limited within a minimized value of the grid. In this study, the unit converter is compared with converters connected in a 6-series to determine a suitable sequence control method. The output voltage is the same in all cases, but the maximum reactive power is reduced from 100% to 73%. This sequence control method is verified through RTDS simulation.