• Title/Summary/Keyword: Current Interruption

검색결과 203건 처리시간 0.024초

45kVA UPQC 제어 알고리즘 설계 (A Control Algorithm Design for 45kVA UPQC Prototype)

  • 전진홍;김태진;류홍제;안종보
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1483-1485
    • /
    • 2005
  • In recent years, customers and power supplies are interested in power quality. Demands of customers are change from standard quality of distribution power system to various high quality of distribution power system. so, it is necessary to apply power quality compensator. in our project, we develop the UPQC(Unfied Power Quality Compensator of 45kVA which compensates power factor and voltage sag, interruption. it is very frequently occurred power quality problems. As a series and shunt compensator, UPQC consists of two inverters with common dc link capacitor bank. It compensates the current quality in the shunt part and the voltage quality in the series part. In this paper, we present simulation and test result of developed UPQC system. Test for UPQC are performed at voltage sag, flickers and non-linear load conditions. For voltage sag and ficker generation, we use RTDS(Real Time Digital Simulator) and power amplifier system.

  • PDF

마이크로프로세서를 이용한 아크결함 차단기 설계 (Arc Fault Circuit Interrupter Design using Microprocessor)

  • 윤광호;반기종;이효직;박병석;남문현
    • 전자공학회논문지SC
    • /
    • 제44권1호
    • /
    • pp.12-18
    • /
    • 2007
  • 본 연구에서 설계한 AFCI는 Arc 고장 차단기로서 종속된 전기 배선상의 노화, 절연 및 배선 파괴, 연결 고장, 절연과 배선에 과도한 기계적 손상으로 인한 아크고장을 검출하여 차단하는 기능을 가지고 있으며 기존 차단기가 가지고 있던 과전류에 의한 바이메탈의 만곡 특성에 의한 동작으로 차단하는 방식은 차단에 긴 시간이 걸리나 설계한 AFCI는 전자방식으로서 과부하, 과전류에 의한 기계적 , 전기적인 스트레스를 검출하여 차단하는 기능을 가진 제품으로 차단시간이 100% 이상 단축되어 전기 화재의 발생률을 낮추도록 하였다.

중간 광전극에 삽입된 산란층에 의한 염료감응 태양전지의 광수집 성능 향상 (Enhancement of the Light Harvesting of Dye-sensitized Solar Cell by Inserting Scattering Layer)

  • 남정규;김범성;이재성
    • 한국분말재료학회지
    • /
    • 제16권5호
    • /
    • pp.305-309
    • /
    • 2009
  • The effect of light scattering layers (400 nm, TiO$_2$ particle) of 4 $\mu$m thickness on the dye-sensitized solar cell has been investigated with a 12 $\mu$m thickness of photo-anode (20 nm, TiO$_2$ particle). Two different structures of scattering layers (separated and back) were applied to investigate the light transmitting behaviors and solar cell properties. The light transmittance and cell efficiency significantly improved with inserting scattering layers. The back scattering layer structure had more effective transmitting behavior, but separated scattering layer (center: 2 $\mu$m, back: 2 $\mu$m) structure (9.83% of efficiency) showing higher efficiency (0.6%), short circuit current density (0.26 mA/cm$^2$) and fill factor (0.02). The inserting separating two scattering layers improved the light harvesting, and relatively thin back scattering layer (2 $\mu$m of thickness) minimized interruption of ion diffusion in liquid electrolyte.

$Ce_{0.8}Gd_{0.2}O_{1.9}$ 전해질에서 $La_{0.5}Sr_{0.5}MnO_{3-\delta}$ 양극의 과전압특성 (Cathodic Polarization of $La_{0.5}Sr_{0.5}MnO_{3-\delta}$ on $Ce_{0.8}Gd_{0.2}O_{1.9}$ Electrolyte)

  • 윤희성;노의범;김병호
    • 한국세라믹학회지
    • /
    • 제35권9호
    • /
    • pp.981-987
    • /
    • 1998
  • $La_{0.5}Sr_{0.5}MnO_{3-\delta}$ as air electrode for soild oxide fuel cell was synthesized by a citrate process and its cathodic polarization was determinated by the current interruption method on the Gd-doped ceria as electrolyte. The addition of citric acid increased the exothermic heat for the formation of $La_{0.5}Sr_{0.5}MnO_{3-\delta}$ perovskite oxide. The degree of the initial particle agglomeration was affected by the exothermic heat. Also the increase of cal-cination temperature enlarged the particle size and the higher sintering temperature accelerated the den-sification of $La_{0.5}Sr_{0.5}MnO_{3-\delta}$ layer after its being painted on $Ce_{0.8}Gd_{0.2}O_{1.9}$ electrolyte. In this study $La_{0.5}Sr_{0.5}MnO_{3-\delta}$ synthesized by citrate process of which the molar ratio of citric acid to metal nitrate was 2 calcined at $650^{\circ}C$ for 2hr and sintered at 1100 at $1200^{\circ}C$ for 4 hrs after slurry coating on Ce0.8Gd0.2O1.9 electrlyte showed the lowest cathodic polarization.

  • PDF

콘크리트 양생 모니터링을 위한 거푸집 일체형 무선센서네트워크(WSN) 시스템 (Form Integrated Wireless Sensor Network for Monitoring of Concrete Curing)

  • 이성복;박원준;조명원;이승엽;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.173-175
    • /
    • 2012
  • Temperature during concrete curing can be effectively used to predict the early age strength of concrete However, various current methods have limits to provide the temperature data in real time due to harsh working environment including frequent cutting of wires. This paper presents the results of our investigation of an all-in-one Wireless sensor network (WSN) for the management of the curing temperature of in-placed concrete at early curing stages. Also, the network device for transmission can be easily separated from the probe sensor part and reused consistently. The field experiment entailed measuring the curing temperature of concrete using the WSN. After fresh concrete was poured into the formworks, the signals were measured at a 150 m radius from the field office. The signal was acquired for 28 days without any dispersion or interruption at the construction site; therefore, this study confirms the applicability of the proposed system to a construction site.

  • PDF

P42 Ebp1 functions as a tumor suppressor in non-small cell lung cancer

  • Ko, Hyo Rim;Nguyen, Truong L.X.;Kim, Chung Kwon;Park, Youngbin;Lee, Kyung-Hoon;Ahn, Jee-Yin
    • BMB Reports
    • /
    • 제48권3호
    • /
    • pp.159-165
    • /
    • 2015
  • Although the short isoform of ErbB3-binding protein 1 (Ebp1), p42 has been considered to be a potent tumor suppressor in a number of human cancers, whether p42 suppresses tumorigenesis of lung cancer cells has never been clarified. In the current study we investigated the tumor suppressor role of p42 in non-small cell lung cancer cells. Our data suggest that the expression level of p42 is inversely correlated with the cancerous properties of NSCLC cells and that ectopic expression of p42 is sufficient to inhibit cell proliferation, anchorage-independent growth, and invasion as well as tumor growth in vivo. Interestingly, p42 suppresses Akt activation and overexpression of a constitutively active form of Akt restores the tumorigenic activity of A549 cells that is ablated by exogenous p42 expression. Thus, we propose that p42 Ebp1 functions as a potent tumor suppressor of NSCLC through interruption of Akt signaling.

멀티-레벨 H-Bridge 인버터를 이용한 Line-Interactive DVR (Line-Interactive DVR Using Multi-Level H-Bridge Inverter)

  • 강대욱;우성민;김태진;최창호;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 추계학술대회 논문집
    • /
    • pp.139-143
    • /
    • 2001
  • Recently, the interest on power quality has been hot issue. The equipments cause voltage disturbance and has become more sensitive to the voltage disturbance. This paper deals with 5-Level H-Bridge Line-Inter active Dynamic Voltage Restorer(LIDVR) system. The LIDVR has following advantages in comparison with the DVR with series injection transformer It has the power factor near to unity under normal source voltage, can compensate the harmonic current of the load and the instant interruption, and has the fast response. First, the construction, the operation mode and algebraic modeling of LIDVR are reviewed. And then a voltage controller is proposed to get sinusoidal load voltage with constant amplitude. To find PWM method suitable for H-Bridge converter, two PWM methods are compared and analyzed. Finally, simulation results verify the proposed 5-level H-Bridge LIDVR system.

  • PDF

A SENSITIVITY STUDY OF THE DISTORTED INLET FLOW IN AXIAL TURBOMACHINERY WITH NOVEL INTEGRAL SCHEME

  • Ng Eddie Yin-Kwee;Liu Ningyu;Lim Hong Ngiap;Tan Daniel
    • 한국전산유체공학회지
    • /
    • 제10권1호
    • /
    • pp.51-55
    • /
    • 2005
  • For proper installation, operation and performance of axial flow jet engines in aircrafts, the impacts and effects of inlet flow distortion in axial compressors have to be understood. Inlet distortion conditions may cause component-mismatch and instability problems known as rotating stall, and severe oscillations of mass flow rate called surge or a combination of both. Typical effects of this phenomenon include stresses and wear on the compressor blading, destruction of entire jet engines due to the failure of airfoil and mechanical failure or interruption of the combustion process. Therefore, it is important to study inlet flow distortion and its propagation effects to minimize and hence to prevent the occurrence of such calamity. The current novel integral method with parametric analysis signifies its validity to this field of research and offers much potential for further improvements. The present effort further indicates that this simple method may be flourishing in the problems of strongly distorted flow and propagating stall in axial compressor. It is therefore believe that using a more realistic and flexible velocity and pressure profiles could develop this approach further.

7-레벨 H-Bridge 인버터를 이용한 Line-Interactive DVR의 전압제어 (A Voltage Control Technique of Line-Interactive DVR Using 7-Level H-Bridge Inverter)

  • 강대욱;현동석;이우철
    • 전기학회논문지
    • /
    • 제56권4호
    • /
    • pp.705-715
    • /
    • 2007
  • Recently, the interest on power quality has been hot issue because the equipments cause voltage disturbance and have become more sensitive to the voltage disturbance. Additionally, the reseach on power electronic equipments applying to the high power has been increased. This paper deals with Line-Interactive Dynamic Voltage Restorer(LIDVR) system using 7-Level H-Bridge inverter, which is one of the solutions to compensate the voltage disturbance and to increase the power of equipments. The LIDVR has the following advantages comparing to the DVR with the series injection transformer. It has the power factor near to unity under the condition of normal source voltage, can compensate the harmonic current of the load and the instant interruption, and has the fast response. First, the construction, the operation mode and algebraic modeling of LIDVR are reviewed. And then the voltage control algorithm is proposed to get the sinusoidal load voltage with constant amplitude. Finally, simulation and experiment results verify the proposed LIDVR system.

에어컨 배수펌프 설치 실태 및 개선방안 분석 - 창원시를 중심으로 (Analysis on Installation Conditions Survey and Improvement of Drain Pump in Air-Conditioner : Focusing on Changwon City)

  • 김성삼
    • 조명전기설비학회논문지
    • /
    • 제26권8호
    • /
    • pp.102-106
    • /
    • 2012
  • This paper was carried out to survey fire hazard and improvement at the drain pump in air-conditioners. Based on the results of analysis, the proposal of electrical accidents prevention and a construction improvement are as follows. A power connection of the drain pump has two types, an electrical outlet type and direct connection type at control board of air-conditioner. The electrical outlet types need a bulletin sign or education as malfunction of the drain pump include an additional accidents, current leakage and overflowing with water on the floor from breaker trip by exterior cause and breaker off by mistake of worker. On the other hand, the direct connection types prevent a power interruption as exterior cause, but it has some trouble, cut of ground cable and without protection device. Usually it doesn't work by electrician when air-conditioner and the drain pump power work. Therefore an education or countermeasures are recommended for not electrician. Generally malfunction of the drain pump causes accumulated materials into the tank. Even though the accumulated materials lead to an overheating and burning as failure of detector occur an idling, periodic inspection of the air-conditioner filter and the drain pump tank prevent the trouble.