• Title/Summary/Keyword: Current Control Loop

Search Result 644, Processing Time 0.033 seconds

A virtual shaker testing experience: Modeling, computational methodology and preliminary results

  • Nali, Pietro;Bettacchioli, Alain;Landi, Guglielmo;Gnoffo, Marco
    • Advances in aircraft and spacecraft science
    • /
    • v.5 no.2
    • /
    • pp.251-258
    • /
    • 2018
  • This work illustrates the progress of a TAS activity at exploring the challenges and the benefits of the Virtual Shaker Testing (VST) approach. The definition and the validation of new computational methodologies with respect to the state of the art were encouraged throughout this activity. The shaker Finite Element (FE) model in lateral configuration was built for the purpose and it was merged with the SpaceCraft (S/C) FE model, together with the S/C-Shaker adapter. FE matrices were reduced through the Craig-Bampton method. The VST transient analysis was performed in MATLAB(R) numerical computing environment. The closed-loop vibration control is accounted for and the solution is obtained through the fourth-order Runge Kutta method. The use of pre-existing built-in functions was limited by authors with the aim of tracing the impact of all the problems' parameters in the solution. Assumptions and limitations of the proposed methodology are detailed throughout this paper. Some preliminary results pertaining to the current progress of the activity are thus illustrated before the conclusions.

Equivalence Between Two Orthogonal Oriented Circular Loops and Planar Inveryed-F Antenna Array (직교형 원형 루프 안테나와 역 에프형 배열구조의 등가성 분석)

  • Kim, Jong-Sung;Park, Seung-Mo;Choi, Won-Kyu;Seong, Nak-Seon
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.289-292
    • /
    • 2005
  • Two planar inverted-F antenna (PIFA) arrays are proposed as an alternative model to generate input and radiation characteristics of two orthogonal oriented circular loops, which has polarization diversity, but inherent mechanical instability of two orthogonal loops, in particular, in installation and operation conditions. Two $1\times2$ PIFA sub-arrays are orthogonally placed on a ground plane and two different feeding networks are applied to control horizontal and vertical radiation current flows for each sub-array, respectively. Equivalence of scattering parameters and radiation patterns between two antennas are validated by the available commercial simulator.

  • PDF

Design of a 49kW high efficiency bidirectional DC-DC converter for charge and discharge of high voltage battery in HEV (하이브리드 자동차 고전압 배터리 충, 방전을 위한 49kW급 고효율 양방향 DC/DC 컨버터 설계)

  • Yang, Jin-Young;Yoon, Chang-Woo;Park, Sung-Sik;Choi, Se-Wan;Park, Rae-Kwan;Chang, Seo-Geon
    • Proceedings of the KIPE Conference
    • /
    • 2007.11a
    • /
    • pp.21-23
    • /
    • 2007
  • In this paper a high efficiency bi-directional DC-DC converter for hybrid vehicles is proposed. The proposed converter a three-phase half-bridge interleaved ZVS converter, is designed to have high efficiency in the main operation range. The component ratings are calculated, the actual devices are selected, and the efficiency analysis has been performed to determine optimal ZVS range. The input and output current ripples are significantly reduced due to the interleaved operation. The dual loop control for the interleaved three-phase converter is also presented. To confirm the proposed convert ter, The simulation and experimental results are presented.

  • PDF

Identification and Damping of Resonances in Inverter-based Microgrids

  • Afrasiabi, Morteza;Rokrok, Esmaeel
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.1235-1244
    • /
    • 2018
  • The application of shunt capacitor banks and underground cables typically induces resonance in power distribution systems. In this study, the propagation of resonance in a microgrid (MG) with inverter-based distributed generators (IBDGs) is investigated. If resonances are not properly damped, then the output current of the inverters may experience distortion via resonance propagation due to the adverse effect of resonances on MG power quality. This study presents a conceptual method for identifying resonances and related issues in multi-inverter systems. For this purpose, existing resonances are identified using modal impedance analysis. However, some resonances may be undetectable when this method is used. Thus, the resonances are investigated using the proposed method based on the frequency response of a closed-loop MG equivalent circuit. After analyzing resonance propagation in the MG, an effective virtual impedance damping method is used in the IBDG control system to damp the resonances. Results demonstrate the effectiveness of the proposed method in compensating for existing resonances.

A Study on the Optimum Design of the Charge Pump PLL with Multi-PFD (다중 위상검출기를 갖는 전하 펌프 PLL의 최적 설계에 관한 연구)

  • Jang, Young-Min;Kang, Kyung;Woo, Young-shin;Sung, Man-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.271-274
    • /
    • 2001
  • In this paper, we propose a charge pump phase-locked loop (PLL) with multi-PFD which is composed of a sequential phase frequency detector(PFD) and a precharge PFD. When the Phase difference is within - $\pi$$\pi$ , operation frequency can be increased by using precharge PFD. When the phase difference is larger than │ $\pi$ │, acquisition time can be shorten by the additional control circuit with increased charge pump current. Therefore a high frequency operation, a fast acquisition and an unlimited error detection range can be achieved.

  • PDF

Development of Three Phase Optimal Power Flow for Distributed Generation Systems (분산전원계통을 위한 3상 최적조류계산 프로그램 개발)

  • Song, Hwa-Chang;Cho, Sung-Koo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.5
    • /
    • pp.882-889
    • /
    • 2010
  • This paper presents a method of finding the optimal operating point minimizing a given objective function with 3 phase power flow equations and operational constraints, called 3 phase optimal power flow (3POPF). 3 phase optimal power flow can provide operation and control strategies for the distribution systems with distributed generation assets, which might be frequently in unbalanced conditions assuming that high penetration rate of renewable energy sources in the systems. As the solution technique for 3POPF, this paper adopts a simulation-based method of particle swarm optimization (PSO). In the PSO based 3POPF, a utility function needs to be defined for evaluation of the degree in operational improvement of each particle's current position. To evaluate the utility function, in this paper, NR-based 3 phase power flow algorithm was developed which can deal with looped distributed generation systems. In this paper, illustrative examples with a 5-bus and a modified IEEE 37-bus test systems are given.

Active Power Filter Type Single Phase Uninterruptible Power Supply(UPS) System (단상 전력용 능동필터형 무정전 전원장치)

  • Kim, Je-Hong;Son, Jae-Hyun
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.36T no.4
    • /
    • pp.53-59
    • /
    • 1999
  • In this paper, a bi-directional UPS with the performance of active power filter has been proposed. The operation of the proposed system can be divided into two modes, such as the active power filter mode and the battery back-up power mode. To improve the transient response for the effective compensation of harmonics and reactive power in active power filter mode, a novel closed-loop control strategy is used to calculate the reference current instantaneously. Finally, the performance of proposed UPS is verified by the simulation and experimental results.

  • PDF

Feasibility Study on the Utilization of Mixed Oxide Fuel in Korean 900MWe PWR Core Through Conceptual Core Nuclear Design and Analysis

  • Joo, Hyung-Kook;Kim, Young-Jin;Jung, Hyung-Guk;Sohn, Dong-Seong
    • Nuclear Engineering and Technology
    • /
    • v.29 no.4
    • /
    • pp.299-309
    • /
    • 1997
  • The neutronic feasibility of typical Korean three-loop 900MWe class PWR core loaded with mixed oxide fuels for both annual and 18-month cycle strategies has been investigated as a means for spent fuel management. For this study, a method of determining equivalent plutonium content was developed under the equivalence concept which gives the same cycle length as uranium fuel. Optimal plutonium zoning within the MOX assembly was also designed with the aim of minimizing the peak md power. Conceptual core designs hate hen developed for equilibrium cycle with the following variations: annual and 18-month cycle, 1/3 and full MOX loading schemes, and typical and high moderation lattice. The analysis of key core physics parameters shows that in all cases considered satisfactory core designs seem to be feasible, though addition of control rod system and change in Technical Specification for soluble boron concentration are required for full MOX loading in order to meet the current design requirements.

  • PDF

A High Frequency Link Direct DC-AC Converter for Fuel Cell Power Source (연료전지 발전 시스템용 고주파 링크 DC-AC 컨버터)

  • Song Y.J.;Jung B.M.;Han S.B.;Jeong H.G.;Park S.I.
    • Proceedings of the KIPE Conference
    • /
    • 2004.11a
    • /
    • pp.124-126
    • /
    • 2004
  • This paper describes a boost converter cascaded high frequency link direct do-ac converter suitable for fuel cell power sources. A new multi-loop control for a boost converter to reduce the low frequency input current harmonics drawn from fuel cell is proposed. A new PWM technique for the cycloconverter at the secondary to reject the low order harmonics in the output voltages is presented in detail.

  • PDF

The Study on Detecting Scheme of Voltage Sag using the Two Difference Voltage (이중 차 전압을 이용한 전압 새그 검출 기법에 관한 연구)

  • Lee, Woo-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.65-73
    • /
    • 2014
  • In this paper, the detection scheme of the voltage variation using a two difference voltage is proposed. The conventional sag detector is from a single-phase digital phase-locked loop (DPLL) that is based on a d-q transformation using an all-pass filter (APF). The APF generates a virtual q-axis voltage component with $90^{\circ}$ phase delay but the APF cannot generate the virtual q-axis voltage depending on the phase of the grid voltage. To overcome the problem, q-axis voltage component is generated from difference between the current and previous value of d-axis voltage component in the stationary reference frame. However, the difference voltage around the zero crossing is not enough to detect the voltage sag. Therefore, the new detection scheme using the two difference voltage which can detect the sag around the zero crossing voltage is proposed.