• Title/Summary/Keyword: Cumulative exposure dose

Search Result 74, Processing Time 0.028 seconds

Evaluation of Reductive Effect of Exposure Dose by Using Air Gap Apron in Nuclear Medicine Related Work Environment (핵의학과 내 작업 환경에서 공기층 납치마의 피폭선량 감소 효과 평가)

  • Lee, Wang-Hui;Ahn, Sung-Min
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.12
    • /
    • pp.845-853
    • /
    • 2014
  • In this study, we measured the dose reaching the OSLD dosimeter by using the regular lead apron, and air gap apron through 3 experiments, and researched the reductive effect of air gap apron on exposure dose based on the 140 keV gamma ray radiating from $^{99m}technetium$, which is the most commonly used in nuclear medicine. As a result, when the gap between the dosimeter and 0.2mm lead plate is 0 Cm, the average value of 10 dosimeters was 0.515 mSv, and when the gap between the dosimeter and lead plate is 20 Cm, the average value of 10 dosimeters was 0.138 mSv, which shows reductive effect of dose as much as 0.388 mSv. When the gap between the dosimeter and 0.5mm lead plate is 0 Cm, the average value of 10 dosimeters was 0.296 mSv, and when the gap between the dosimeter and lead plate is 20 Cm, the average value of 10 dosimeters was 0.075 mSv, which shows reductive effect of dose as much as 0.221 mSv. As we check the cumulative dosage for 3 days, the lead apron without air layer shows average 0.239 mSv, and the air gap apron shows 0.176 mSv, which is actually reduced by 0.062 mSv. As we check the cumulative dosage for a month, the lead apron without air layer shows 0.59 mSv, and the air gap apron shows 0.54 mSv, which is reduced by 0.05 mSv.

Chromosome Aberration in Peripheral Lymphocyte of Radiation Workers in Hospital (병원내 방사선작업종사자들의 염색체이상빈도)

  • Yi, Chun-Ja;Ha, Sung-Whan;Jung, Hae-Won
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.4
    • /
    • pp.227-235
    • /
    • 1997
  • Cytogenetic studies were performed in peripheral blood lymphocytes from hospital workers occupationally exposed to low doses of radiation (0.30 - 40.07mSv). The workers were divided into three groups according to their job area : 18 diagnostic radiology, 17 therapeutic radiology, and 16 nuclear medicine. The control group consisted of 49 non-radiation workers with no history of exposure to radiation. A higher percentage of cells with aberration(1.275%) was observed in the workers compared to the controls(0.677%) and the difference was statistically significant(p<0.001). The frequency of chromosomal aberration was $0.706{\times}10^{-2}$/cell in the exposed and $0.344{\times}10^{-2}$/cell in the control(p<0.05). Chromosomal exchange frequency was $0.083{\times}10^{-2}$/cell in the control vs $0.245{\times}10^{-2}$/cell in the workers. There was no evidence of significant increase of chromosome aberration related to age or to the duration of employment. The frequency of chromosomal exchange in workers of nuclear medicine was $0.313{\times}10^{-2}$/cell, which was significantly higher than in the control($0.083{\times}10^{-2}$/cell) or other working groups: therapeutic radiology($0.265{\times}10^{-2}$/cell), and diagnostic radiology($0.167{\times}10^{-2}$/cell). No dose-effect relation was found between chromosome aberration and total cumulative doses, recent 5 yr, recent 2 yr cumulative dose. But in case of last 1 yr cumulative dose, dose-dependant increase was observed when controls were considered(p<0.05). The radiation dose which workers have received was much lower than the maximum permissible dose, but there was a significant difference in the frequency of chromosome aberration between occupationally exposed workers and control. So, it is clear that chromosome aberration is a quite sensitive indicator of radiation exposure and it can be detected at very low dose level of occupational exposure.

  • PDF

Research on the Hematological Changes in Accordance with Radiation Dose and Radiation Exposure period of the Medical Radiation Workers (의료 방사선 종사자의 피폭기간 및 피폭선량과 혈액성분 변화에 대한 조사)

  • Cho, Jihwan;Jin, Seongjin;Park, Cheolwoo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.7
    • /
    • pp.495-502
    • /
    • 2016
  • In this study, we analyzed the effects of radiation exposure, as compared to the hematological parameters change of medical radiation workers and the public. The mean value of all hematological parameters were in the normal range. Eosin mean value of the radiation workers($2.52{\pm}1.79%$) showed that a significantly lower than the control group($2.92{\pm}1.39%$). In the comparison of the results depending on the occupation period, it showed high value that the mean of the radiation workers group WBC, platelet, Lymph, Mono, Baso. Over 20 years of radiation workers WBC, Mono showed low values and less than 10 years of radiation workers mean value of Baso showed low values, there was no statistical significance. In the comparison of the results depending on the 4 years cumulative radiation dose, Over 5.0 mSv of Radiation works RBC($4.61{\pm}0.53$ vs $4.91{\pm}0.38$), Hct($41.51{\pm}4.07$ vs $43.97{\pm}3.40$), Eosin($1.74{\pm}1.14$ vs $2.92{\pm}1.39$) showed low value, it was statistical significance. 0.5~1.0 mSv radiation exposure workers Hb ($13.93{\pm}1.75$) showed a significantly lower value than that of the control group ($14.90{\pm}1.29$).

Calculation of an Indicator for Early Death Using Atomic Bomb Survivors' Data

  • Sasaki, Michiya;Fujimichi, Yuki;Yoshida, Kazuo;Iwasaki, Toshiyasu
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.1
    • /
    • pp.22-29
    • /
    • 2022
  • Background: A comprehensive, traceable, and easy-to-understand radiation risk indicator is desired for radiological protection. The early-onset hypothesis could be used for this purpose. Materials and Methods: An indicator for early death (IED) was developed and calculated using the epidemiological dataset from the 14th Report of the Life Span Study (LSS) of Hiroshima and Nagasaki. By clarifying the calculation process, IED for all-cause mortality was estimated. In addition, the characteristics of IED for solid cancer mortality and cardiovascular mortality as well as those of men and women, and their dependence on age at exposure were investigated for detailed analysis. Results and Discussion: The IED for all-cause mortality was estimated to be approximately 4 years for an acute radiation exposure of 1 Gy regardless of the fitting dose range. The cumulative death rate for all solid cancers also indicated the early-death tendency (approximately 7-10 years at 1 Gy). Although, there is a slight difference in the characteristics of the risk obtained from the LSS study and this study, it is considered that the IED in a unit of years can also be used to show the overall picture of risk due to radiation exposure. Conclusion: We developed and calculated the indicator for early death, IED, for the cumulative mortality rate of all causes of death, all solid cancers, and circulatory diseases. The quantitative values of IED were estimated to be 4 years for all causes of death, 7-10 years for all solid cancers. IED has an advantage for intuitively understanding the meaning of radiation risk since it can be obtained by a simple and traceable method.

Dose Assessment of the Eye of the Operator in the Field of Angiography and Interventional Radiography (혈관조영 및 중재적 시술 분야 내 종사자의 눈에 대한 선량평가)

  • Kim, Jung-hoon;Cho, Yong-In
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.209-216
    • /
    • 2018
  • In the field of angiography and interventional radiology, it is said that the risk of radiation exposure to the eyes is high due to the characteristics of work, but currently divided dose assessment and management are not carried out in reality. Therefore, in this study, in order to evaluate the dose of the operator in the surgical environment and to analyze the shields, firstly, we selected the point where the operator is mainly located, evaluated the exposure dose of the eye after attaching the pocket dosimeter to the lateral angle point of the head and neck phantom, and evaluate shielding effect when wearing lead glasses that is currently commercialized. Secondly, we evaluated the tendency of the exposure dose of the eye and the shielding effect through simulation in the same geometric structure as the actual measurement. As a result, in the case of measurement using a dosimeter, the cumulative dose increased with the increase of the fluoroscopic time, and the tendency was different according to the position of the operator. Simulation results show that the dose distribution of the eye lens in the mathematical phantom is about 1.1 ~ 1.3 times higher than that of the cornea. Also, The protective effect of the lead glasses showed a shielding effect of at least 3.7 ~ 21.4% in each eye.

Evaluation on the Radiation Exposure of Radiation Workers in Proton Therapy (양성자 치료 시 방사선 작업 종사자에게 미치는 방사선 피폭에 대한 평가)

  • Lee, Seung-Hyun;Jang, Yo-Jong;Kim, Tae-Yoon;Jeong, Do-Hyung;Choi, Gye-Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.107-114
    • /
    • 2012
  • Purpose: Unlike the existing linear accelerator with photon, proton therapy produces a number of second radiation due to the kinds of nuclide including neutron that is produced from the interaction with matter, and more attention must be paid on the exposure level of radiation workers for this reason. Therefore, thermoluminescence dosimeter (TLD) that is being widely used to measure radiation was utilized to analyze the exposure level of the radiation workers and propose a basic data about the radiation exposure level during the proton therapy. Materials and Methods: The subjects were radiation workers who worked at the proton therapy center of National Cancer Center and TLD Badge was used to compare the measured data of exposure level. In order to check the dispersion of exposure dose on body parts from the second radiation coming out surrounding the beam line of proton, TLD (width and length: 3 mm each) was attached to on the body spots (lateral canthi, neck, nipples, umbilicus, back, wrists) and retained them for 8 working hours, and the average data was obtained after measuring them for 80 hours. Moreover, in order to look into the dispersion of spatial exposure in the treatment room, TLD was attached on the snout, PPS (Patient Positioning System), Pendant, block closet, DIPS (Digital Image Positioning System), Console, doors and measured its exposure dose level during the working hours per day. Results: As a result of measuring exposure level of TLD Badge of radiation workers, quarterly average was 0.174 mSv, yearly average was 0.543 mSv, and after measuring the exposure level of body spots, it showed that the highest exposed body spot was neck and the lowest exposed body spot was back (the middle point of a line connecting both scapula superior angles). Investigation into the spatial exposure according to the workers' movement revealed that the exposure level was highest near the snout and as the distance becomes distant, it went lower. Conclusion: Even a small amount of exposure will eventually increase cumulative dose and exposure dose on a specific body part can bring health risks if one works in a same location for a long period. Therefore, radiation workers must thoroughly manage exposure dose and try their best to minimize it according to ALARA (As Low As Reasonably Achievable) as the International Commission on Radiological Protection (ICRP) recommends.

  • PDF

Studies on Digitalis Receptor Desensitization in Rat Ventricle (쥐 심실에서 Digitalis Receptor Desensitization에 관한 연구)

  • 이신웅;이정수;장태수
    • Biomolecules & Therapeutics
    • /
    • v.2 no.2
    • /
    • pp.114-119
    • /
    • 1994
  • [$^3$H]Ouabain binding parameters ( $K_{D}$ and $B_{max}$) to control rat ventricular strips and Langendorff preparations which were not previously exposed to ouabain were compared with those to both preparations that had been first exposed to a complete ouabain dose range of dose-response curve (10$^{-8}$ to 10$^{4}$M). In rat ventricular strips and Langendorff perfused heart preparations, cumulative dose-response curves of ouabain revealed biphasic positive inotropic effects, a "low-dose" effect and a "high-dose" effect with E $d_{50}$ values of 0.5 $\mu$M and 35 $\mu$M ouabain, respectively. The "low-dose" effect in ventricular strip disappeared or was diminished significantly when the ouabain dose-response curve was repeated after the washout of the effects of the first dose-response curve, whereas there were no significant differences in the maximal "high-dose"effect in both exposures to oubain. However, both of the control and ouabain-preexposed Langendorff perfused hearts revealed the same low-dose effects. The $K_{D}$ value for [$^3$H] ouabain binding and the ouabain binding site concentration ( $B_{max}$) estimated by [$^3$H]ouabain displacement assay in control preparations were 230 nM and 2 pmol/mg protein, respectively. [$^3$H]Ouabain binding parameters were not changed by repeated exposure to high concentrations of ouabain. These results suggest that digitalis receptor desensitization in the rat ventricular strip may due to the change of post-receptor events induced by ouabain binding to a high affinity site ($\alpha$$_2$isoform).).).).).

  • PDF

A Scientific Critique of a Korean Court's Acquittal for Involuntary Manslaughter Related to 5-chloro-2-methylisothiazol-3(2H)-one/2-methylisothiazol-3(2H)-one (CMIT/MIT), a Humidifier Disinfectant (HD) Part I: Material safety, exposure and delivery to target organ from an HD perspective (CMIT/MIT 함유 가습기 살균제 제품의 제조 및 판매기업 형사판결 1심 재판 판결문에 대한 과학적 고찰 (I) - 제품 위험성과 노출평가 측면에서)

  • Park, Dong-Uk;Zoh, Kyung Ehi;Kim, Jiwon;Choi, Sangjun;Kwon, Jung-Hwan;Jun, Houngbae;Kim, Sungkyoon
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.2
    • /
    • pp.111-122
    • /
    • 2021
  • Objectives: There was a judgment of acquittal for the manufacturer SK Chemical and the vendor Aekyung regarding humidifier disinfectant (HD) containing 5-chloro-2-methylisothiazol-3(2H)-one/2-methylisothiazol-3(2H)-one (CMIT/MIT). The rationale used in this judgement is discussed here in the light of scientific consideration. Methods: The sentencing document for the judgements was obtained from the Korea Supreme Court Service. In particular, the judgements made by the court related to the risk of HD and external and internal exposure to CMIT/MIT are discussed based on scientific evidence. Results: Rendering a determination in a criminal trial of insufficient evidence of causation, the court dismissed the prosecution's motion that humidifier disinfectant-associated lung injuries (HDLI) and asthma were associated with the utilization of these products. However, CMIT/MIT, a strong sensitizing and corrosive substance, has been reported to be associated with brain toxicity, allergic contact dermatitis, and asthma. Furthermore, the judgment did not consider total consumption amounts or the cumulative dose of CMIT/MIT in the humidifier. Lastly, there are several cases supporting the fact that exposure to water-soluble substances including CMIT/MIT can cause lower respiratory tract diseases. In addition to cases of asthma among the workers exposed to CMIT/MIT, we identified lung injury victims who were exposed to HDs exclusively containing CMIT/MIT. Conclusions: We conclude that there is sufficient evidence supporting the assertion that HDs containing CMIT/MIT cause lung injuries, including asthma, contrary to the court's judgement.

IDENTIFICATION OF GENES EXPRESSED IN LOW-DOSE-RATE γ-IRRADIATED MOUSE WHOLE BRAIN

  • Bong, Jin Jong;Kang, Yu Mi;Choi, Seung Jin;Kim, Dong-Kwon;Lee, Kyung Mi;Kim, Hee Sun
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.166-171
    • /
    • 2013
  • While high-dose ionizing radiation results in long term cellular cytotoxicity, chronic low-dose (<0.2 Gy) of X- or ${\gamma}$-ray irradiation can be beneficial to living organisms by inducing radiation hormesis, stimulating immune function, and adaptive responses. During chronic low-dose-rate radiation (LDR) exposure, whole body of mice is exposed to radiation, however, it remains unclear if LDR causes changes in gene expression of the whole brain. Therefore, we aim to investigate expressed genes (EGs) and signaling pathways specifically regulated by LDR-irradiation ($^{137}Cs$, a cumulative dose of 1.7 Gy for total 100 days) in the whole brain. Using microarray analysis of whole brain RNA extracts harvested from ICR and AKR/J mice after LDR-irradiation, we discovered that two mice strains displayed distinct gene regulation patterns upon LDR-irradiation. In ICR mice, genes involved in ion transport, transition metal ion transport, and developmental cell growth were turned on while, in AKR/J mice, genes involved in sensory perception, cognition, olfactory transduction, G-protein coupled receptor pathways, inflammatory response, proteolysis, and base excision repair were found to be affected by LDR. We validated LDR-sensitive EGs by qPCR and confirmed specific upregulation of S100a7a, Olfr624, and Gm4868 genes in AKR/J mice whole brain. Therefore, our data provide the first report of genetic changes regulated by LDR in the mouse whole brain, which may affect several aspects of brain function.

Dose metrology: TLD/OSL dose accuracy and energy response performance

  • Omaima Essaad Belhaj;Hamid Boukhal;El Mahjoub Chakir;Meryeme Bellahsaouia;Siham Belhaj;Younes Sadeq;Mohammed Tazi;Tahar El Khoukhi;Maryam Hadouachi;Khaoula Laazouzi
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.717-724
    • /
    • 2023
  • An essential step in evaluating and comparing the performance of two passive radiation dosimeter types, thermosluminescent (TLD) and optically stimulated luminescence (OSL), used by workers in environments with ionizing radiation for individual radiological monitoring and control of external exposure at various times (cumulative dose for 1 month), is to compare the measured dose accuracy, energy response, and coefficient of variation. In fact this performance study consists in determining the accuracy of both R(10) and R(0.07) which are considered as the ratios of the measured dose (Hp(10) or Hp(0.07)) to the delivered dose (Hp(10) or Hp(0.07)) for each photon energy. The validity of the results of this test is based on the acceptance limits of the ICRP and the international standard IEC-62387. The relative energy response used is normalized to the 137Cs 662 keV energy to find which energy response is closest to the ideal case, and the coefficient of variation that allows to determine the statistical fluctuation of the Hp(10) and Hp(0.07) doses. The results of the accuracy test for the OSL and TLD dosimeters are acceptable because they fall within the ICRP limits. For the energy response, the OSL performs better than the TLD for Hp(10) and Hp(0.07), and for the coefficient of variation, the OSL satisfies the requirements of ISO 62387 for both Hp(10) and Hp(0.07), while the TLD satisfies these requirements only for the measurement of Hp (0.07).