• 제목/요약/키워드: Culvert spacing

검색결과 8건 처리시간 0.031초

배수효율이 높은 지하암거의 간격과 주름유공관의 통수능 비교분석 (A Comparative Study on the Spacing and Discharge Performance of Subsurface Drainage Culvert to Increase Drainage Efficiency)

  • 김현태;유전용;정기열;박영준
    • 한국농공학회논문집
    • /
    • 제61권6호
    • /
    • pp.67-72
    • /
    • 2019
  • This study compared the theory of a culvert spacing and analytical results of the seepage flow for the subsurface drainage. i) If culvert spacing (Sc) is within 5 m, the unit drainage (q) is very larger; in contrast, if Sc is 5 m or more, there is very little drainage in the middle between drains. Therefore, the drain spacing should be within 5 m to ensure high drainage efficiency. ii) Since the planned culvert drainage increases linearly with the soil's permeability coefficient (k), k must be taken into account when determining the drain diameter by the planned culvert drainage. iii) As a result of analyzing the drainage performance of the absorbing culvert, the drainage performance is sufficient with the diameter of the corrugated drain pipe Dc = 50 mm at the length of the drain Lc = 100 m. iv) Therefore, if the drain spacing (Sc) is less than 5 m using the low-cost non-excavated drainage pipe method (${\Phi}50mm$ the corrugated drain pipe and fiber mat) rather than the conventional trench drain method (Sc > 10 m, Dc > 100 mm), uniform and high drainage efficiency can be ensured as well as low construction cost. v) The sub-irrigation+drainage culvert requires narrower drain spacing (Sc < 2-3 m) for irrigation. As a result of examining the condition of 35 mm in diameter (Dc) and 2~3 m in drain spacing, it is possible to apply the non-excavated drainage pipe method to the sub-irrigation+drainage culvert because drainage performance is sufficient at the drain length Lc = 50 m.

Real-scale field testing for the applicability examination of an improved modular underground arch culvert with vertical walls

  • Tae-Yun Kwon;Jin-Hee Ahn;Hong-duk Moon;Kwang-Il Cho;Jungwon Huh
    • Advances in concrete construction
    • /
    • 제15권6호
    • /
    • pp.377-389
    • /
    • 2023
  • In this study, an improved modular arch system with the lower arch space composed of a precast arch block and an outrigger was proposed as an underground culvert, and its applicability and structural behaviors were confirmed. This modular arch culvert structure with vertical walls was designed using precast blocks and by adjusting the placement spacing of concrete blocks to the upper part form an arch shape and the lower part form a vertical wall shape, based on previously researched modular arch systems. Owing to the vertical wall of the proposed modular arch system, it is possible to secure a load-carrying capacity and an arch space that can sufficiently resist the earth pressure generated from the backfill soil and loading on the arch system. To verify the structural characteristics, and applicability of the proposed modular precast arch culvert structure, a full-scale modular culvert specimen was fabricated, and a loading test was conducted. By examining its construction process and loading test results, the applicability and constructability of the proposed structure were analyzed along with its structural characteristics. In addition, its the structural predictability and safety for the applicability were evaluated by comparing the construction process and loading test results with the FE analysis results.

비굴착 지하배수암거 형태별 지하배수 성능 비교분석 (Comparative Study on the Subsurface Drainage Discharge Performance by the Type of Non-Excavation Subsurface Drainage Culvert)

  • 김현태;유전용;정기열;서동욱
    • 한국농공학회논문집
    • /
    • 제60권6호
    • /
    • pp.73-81
    • /
    • 2018
  • In this study, subsurface discharge performance has been studied through theoretical seepage analysis on four types of culverts that can be installed under the condition of non-excavation, such as (a)perforated pipe(${\Phi}50mm$), (b)perforated pipe+horizontal mat (B50cm) (c)perforated pipe+horizontal mat+vertical gravel(B<10cm), (d)perforated pipe+vertical gravel(B<10cm), and existing typical type (e)perforated pipe with gravel (B40, h=40cm) which can be installed by excavation. The analysis results were as follows. i) Subsurface discharge performance per unit (m) was (a)type 56%, (b) 91%, (c) 96%, (d) 76%, respectively, lower than the value of (e)culvert. ii) However, considering that non-excavation culvert can be installed at a spacing of 5m with the installation cost of the existing excavation culvert at the interval of 10m, it was analyzed that unit subsurface discharge(q) of (a)20.2mm/day(110%), (b)32.8(178%), (c)34.6(188%) (d)27.5(149%) in the four types of non-excavation culvert installed at intervals of 5m under the condition of $ k=10^{-4}cm/s$ was much larger than the amount of (e)type 18.5(100%), existing excavation culvert installed at 10m interval. iii) Through the test construction, peak subsurface drainage discharge($q_p$) was 38.4mm/day, which is larger than the value of design criteria and confirmed that it satisfies the analysis results as well. iv) In particular, it was evaluated that (b)perforated pipe+horizontal mat(B50cm) are low cost, high efficiency subsurface drainage culvert type with sufficient drainage performance(178%).

Performance evaluation of a subsurface drainage culvert system in converted paddy fields

  • Do, Jong Won;Park, Jongseok;Kim, Hyuntai;Lee, Kwangya;Shin, Hyungjin
    • 농업과학연구
    • /
    • 제47권2호
    • /
    • pp.263-273
    • /
    • 2020
  • With the change of the agricultural environment (increased rice production, decreased rice consumption, and rice production policies), converting paddy fields into upland fields is an increasing trend. In terms of conversion into upland fields, subsurface drainage is one of the most important factors for good field crop growth. This study evaluates the performance of a subsurface drainage culvert system in paddy fields and reclaimed lands. The obtained results are briefly summarized as follows: 1) After a comparative evaluation of several subsurface drainage culvert systems, including excavated subsurface drainage and non-excavated subsurface drainage types, type 3 (non-excavated, perforated drain pipe 50 mm, filter mat B50 cm, subsoiling 70 cm and culvert spacing 5 m) shows relatively high values among four types in terms of effectiveness (subsurface discharge capability) and economic efficiency (construction cost). 2) Type 3 has proven that it is suitable for design standards of discharge capacity through field tests performed in paddy fields (three sites: Gong-geom, Gae-san, Juk-san) and reclaimed lands (two sites: Gum-ho, Mi-am). 3) In the experiment of Sesamum indicum growth according to the existence of a drainage system, Sesamum indicum growth with a subsurface drainage culvert system had good value in terms of plant shoot and root length, shoot fresh and dry weight, and root fresh and dry weight).

배수불량 논에서 암거배수처리가 동.하계 사료작물생산에 미치는 영향 (Effect of Drainage Culvert Spacing on Forage Crops Production in Poorly Drained Paddy Field Converted to Upland Crop Cultivation)

  • 신재순;전종길;이상봉;김원호;윤세형;이종경;김종근;정민웅;서성;임영철
    • 한국초지조사료학회지
    • /
    • 제28권4호
    • /
    • pp.301-306
    • /
    • 2008
  • 본 시험은 천안시 성환읍에 위치한 배수가 불량한 논에서 사료작물재배를 위해 암거배수 간격을 3 m, 5 m 그리고 7 m로 처리하고 여름 사료작물로는 옥수수와 수수$\times$수수 교잡종, 겨울 사료작물로는 청보리를 조합하여 옥수수와 청보리 조합, 수수$\times$수수 교잡종과 청보리 조합 등 2개의 작부체계에 대한 재배효과를 비교하기 위해 2006년 3월부터 2007년 5월까지 수행되었다. 배수간격별 출현율과 출수 시는 차이가 없었다. 출현율은 옥수수가 90%, 수수$\times$수수 교잡종이 91%, 청보리가 92%로 조사되었다. 옥수수의 출수시는 7월 26일, 수수$\times$수수교잡종은 7월 21일 그리고 청보리는 4월 27일이었다. 배수처리간격별 건물 수량의 경우, 3m 간격 (24,389 kg/ha) < 5 m 간격 (23,543 kg/ha) < 7 m 간격 (21,527 kg/ha) 순으로 높았는데 3 m 간격과 5 m 간격 간에는 유의차가 없었다. 작부체계간에는 수수$\times$수수 교잡종과 청보리 조합(22,000 kg/ha)이 옥수수와 청보리 조합(19,684 kg/ha)보다 높았다(p<0.05). 배수간격별 조단백질 및 TDN 수량은 3 m간격(2,365 kg/ha, 15,394 kg/ha) < 5 m 간격 (2,255 kg/ha, 14,513 kg/ha) < 7 m 간격(1,884 kg/ha, 13,747 kg/ha) 순으로 높았다. 작부체계별 조단백질과 TDN 수량은 수수$\times$수수 교잡종과 청보리 조합(2,165 kg/ha, 13,582 kg/ha)이 옥수수와 청보리 조합(1,576kg/ha, 12,482 kg/ha)보다 높았다. 이상의 결과를 종합해 볼 때 배수불량 논을 활용하여 조사료를 생산하기 위해서는 작부체계는 수수$\times$수수 교잡종과 청보리 조합으로 배수간격은 5 m 간격이 적당한 것으로 사료된다.

콘크리트 BOX암거 구조물의 초기 균열제어 연구 (Study on Controlling of Cracks of Concrete Box Culvert in Early Ages)

  • 이주호;박경래;배한욱;박성규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.731-736
    • /
    • 2001
  • In this thesis, the study on controlling of cracks of concrete box culvert in early ages is presented. The optimum construction method and economical analysis were proposed also through the experiment of the material and field test. As a result of the experiment of the material, using fly ash, CSA expansive agent and BELITE cement(type IV) showed good result in the control of cracks induced by heat of hydration and shrinkage. As a result of construction test analysis, the maintenance time of form system did not show a big difference in controlling of cracks. Control of distribution of reinforcement, spacing of expansion joint and use of BELITE cement showed big differences in the control of cracks in early ages. As a result of economical analysis, control of construction variables before construction can make it possible to reduce the repair expense.

  • PDF

특수 구간 도로 포장에 포스트텐션 콘크리트 포장 적용 방안 (Application Methodologies of Post-Tensioned Concrete Pavements for Specialized Section Pavements)

  • 배종오;박희범;김성민
    • 한국도로학회논문집
    • /
    • 제13권2호
    • /
    • pp.167-174
    • /
    • 2011
  • 본 연구는 특수 구간의 도로 포장에 포스트텐션 콘크리트 포장(PTCP: Post-Tensioned Concrete Pavement) 공법을 적용하기 위한 설계 방안을 제시하기 위하여 수행되었다. 본 연구에서 고려한 특수 구간으로는 기존의 포장에서 많은 문제점이 발생하는 도심지 버스전용차로 정류소 구간과 고속도로 암거 설치 구간을 선정하였다. 이러한 특수 구간의 PTCP 설계는 응력 기준 설계와 피로파손 기준 설계로 이루어지며 두 설계 결과 중에서 보수적인 결과를 설계에 적용한다. 응력 기준 설계에서는 유한요소해석을 통해 극한의 하중조건을 고려하여 발생할 수 있는 최대 인장응력을 산정한 뒤 이를 감소시켜서 최대 인장응력이 허용휨강도 이하가 되도록 텐던의 개수와 긴장 간격을 산정하였다. 피로파손 기준 설계에서는 AASHTO 피로파손 공식을 기반으로 긴장 설계를 수행하였다. 연구결과, 버스전용차로 정류소 구간과 암거 설치 구간에 PTCP 공법을 적용할 수 있는 설계 방안을 수립하였다.

수리·수문기술을 적용한 도로 배수시설 설계 기법 (Road Drainage Facility Design Methods apply on the Hydraulic and Hydrologic Analysis)

  • 이만석
    • 한국수자원학회논문집
    • /
    • 제45권4호
    • /
    • pp.419-430
    • /
    • 2012
  • 도로 배수시설 설계시 수리 및 수문요소 분석이 적절하게 적용되어야 하지만, 현재는 계산의 복잡함 때문에 충분히 고려되지 못하고 있다. 본 연구에서는 강우지속시간이 10분 이하인 도로배수유역에 적합한 분단위 강우강도식의 개발, 국내 도로배수유역의 지형 특성을 사실적으로 반영할 수 있는 운동파 모형 이론을 접목한 표면 박류 강우-유출 모형의 개발및검증, 노면배수시설설계, 암거단면규격산정및각종수로설계등의모형개발, 개발된 모형들을 도로설계자가 쉽게 익혀서 신속 정확하게 활용할 수 있도록 사용자 편의를 고려한 도로배수설계 전산프로그램을 개발하였다. 개발된 모형을 이용하여 적용성 검토를 수행하였으며, 현행 설계 방법과 개발된 설계 방법을 비교한 결과 노면 배수시설의 설치 간격은 6~65% 짧게 계산되었으며, 횡단 배수시설의 단면 크기는 6~140% 크게 계산되었다.