• Title/Summary/Keyword: Cuk Converter

Search Result 29, Processing Time 0.03 seconds

Digital Control of an AC/DC Converter using the Power Balance Control Technique with Average Output Voltage Measurement

  • Wisutmetheekorn, Pisit;Chunkag, Viboon
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.88-97
    • /
    • 2012
  • This paper presents a method for the digital control of a high power factor AC/DC converter employing the power balance control technique to achieve a fast response of the output voltage control. To avoid the effects of an output voltage ripple in the voltage control loop, the average output voltage is sampled and used as a feedback signal for the output voltage controller. The proposed control technique was verified by simulations using MATLAB/Simulink and its implementation was realized by a dsPIC30F4011 digital signal processor to control a CUK topology AC/DC converter with a 48V output voltage and a 250 W output power. The experimental results agree with the simulation results. The proposed control technique achieves a fast transient response with a lower line current distortion than is achieved when using a conventional proportional-integral controller and the power balance control technique with the conventional sampling method.

A New Family of Non-Isolated Zero-Current Transition PWM Converters

  • Yazdani, Mohammad Rouhollah;Dust, Mohammad Pahlavan;Hemmati, Poorya
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1669-1677
    • /
    • 2016
  • A new auxiliary circuit for boost, buck, buck-boost, Cuk, SEPIC, and zeta converters is introduced to provide soft switching for pulse-width modulation converters. In the aforementioned family of DC-DC converters, the main and auxiliary switches turn on under zero current transition (ZCT) and turn off with zero voltage and current transition (ZVZCT). All diodes commutate under soft switching conditions. On the basis of the proposed converter family, the boost topology is analyzed, and its operating modes are presented. The validity of the theoretical analysis is justified by the experimental results of a 100W, 100 kHz prototype. The conducted electromagnetic emissions of the proposed boost converter are measured and found to be lower than those of another ZCT boost converter.

Redundant Operation of a Parallel AC to DC Converter via a Serial Communication Bus

  • Kanthaphayao, Yutthana;Kamnarn, Uthen;Chunkag, Viboon
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.533-541
    • /
    • 2011
  • The redundant operation of a parallel AC to DC converter via a serial communication bus is presented. The proposed system consists of three isolated CUK power factor correction modules. The controller for each converter is a dsPIC30F6010 microcontroller while a RS485 communication bus and the clock signal are used for synchronizing the data communication. The control strategy of the redundant operation relies on the communication of information among each of the modules, which communicate via a RS485 serial bus. This information is received from the communication checks of the converter module connected to the system to share the load current. Performance evaluations were conducted through experimentation on a three-module parallel-connected prototype, with a 578W load and a -48V dc output voltage. The proposed system has achieved the following: the current sharing is quite good, both the transient response and the steady state. The converter modules can perform the current sharing immediately, when a fault is found in another converter module. In addition, the transient response occurs in the system, and the output voltages are at their minimum overshoot and undershoot. Finally, the proposed system has a relatively simple implementation for the redundant operation.

Compare of buck-boost converter and Boost converter using the IC MPPT method Efficiency (IC MPPT 방법을 이용한 벅-부스트 컨버터와 부스트 컨버터의 효율분석 및 비교)

  • Kim, Yu-Tak;Ko, Jae-Sub;Seo, Tae-Young;Kang, Sung-Min;Chung, Dong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.952-953
    • /
    • 2015
  • In this paper, various MPPT control in the most simple and widely used method of IC using the method According to the type of DC-DC converter to analyze the efficiency buck-boost convertor, Cuk convertor using each efficiency was analyzed.

  • PDF

A Study on Photovoltaic Generation System by DC-DC converter (DC-DC 컨버어터에 의한 태양광 발전 시스템에 관한 연구)

  • Won, Chung-Yuen;Yang, Seung-Ho;Kim, Hack-Seong;Kim, Sei-Chan
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.486-491
    • /
    • 1991
  • The photovoltaic modules have each maximum power point, which depending on the intensity of sunlight, modules temperature and etc. Cuk converter is used to obtain the maximum charging power from photovoltaic modules to storage batteries. This paper proposed to a new tracking control method by detecting its current and voltage in photovoltaic power generation system controlled by microprocessor, in order to operate at the maximum power point tracking(MPPT) even if the sunlight and the temperature are varied.

  • PDF

A New Phase Converter Uninterruptible Power Bypass Device for the Replacement of Distribution Transformers (배전선로 무정전 변압기 교체를 위한 새로운 위상변환 장치)

  • Shin, Dong-Yeol;Kim, Cuk-Cheol;Yoon, Gi-Gab;Cha, Han-Ju
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.715-716
    • /
    • 2007
  • 배전선로의 주상변압기 교체 공법은 시공방법에 따라 전력품질이 좌우된다고 할 수 있으나, 지금도 개선되지 않은 방법으로 작업을 하고 있어 부실시공에 의한 고장정전과 안전사고가 근절되지 않고 있으며, 공사비가 과다발생 하는 문제점이 있는 등 전력신기술에 의한 시공품질 관리가 절실히 요구되는 분야이다. 따라서, 본 논문에서는 새로운 위상변환장치를 이용한 무정전 공법을 제안한다. 제안한 공법은 현행 공법의 문제점을 획기적으로 개선함으로써 안정적인 전력공급과 동시에 배전원가 절감에 따른 저렴한 전기요금으로 국민생활에 편리함을 더하고 국가경제 발전에 기여하게 될 것으로 기대된다.

  • PDF

An Efficiency Improvement of the Photovoltaic Generation System by Using the PPT based Converter (병렬전력전달 방식에 의한 DC/DC 컨버터의 효율 개선)

  • Lee, Seong-Ryong;Jeon, Chil-Hwan;Lee, Eun-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1404-1406
    • /
    • 2005
  • 본 논문에서는 기존의 DC/DC 컨버터에 특별한 소자의 부가나 가격의 증가 없이 효율을 향상시키기 위한 방안에 대하여 논하였다. 이에 따라 병렬전력전달 방식(Parallel Power Transfer, PPT) 기반 Cuk 컨버터를 제안하였고, 이의 효율 향상 효과를 이론적으로 해석하고, 기존에 널리 사용되고 있는 DC/DC 컨버터와 특성을 비교 분석하였다. 마지막으로 이를 제안된 이론을 기본으로 DC 48V 전원 공급용 시스템을 설계하고, 구성한 다음 PSIM 시뮬레이션을 통해 시스템의 효율 향상 효과와 그 유용성을 입증하였다.

  • PDF

ESL-𝚪-Z- Source Inverter

  • Pan, Lei;Sun, Hexu;Wang, Beibei;Dong, Yan;Gao, Rui
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.589-599
    • /
    • 2014
  • On the basis of the traditional ZSI (Z-source inverter), this paper presents a ESL-${\Gamma}$-ZSI, which uses a unique ${\Gamma}$-shaped impedance network and an extended SL network for boosting its output voltage in addition to their usual voltage-buck behavior. The inverter can increase the boost factor through adjusting shoot-through duty ratio and increasing the number of inductors. Capacitor voltage stress of ESL-${\Gamma}$-ZSI is a constant when 1>D>0, and ESL-${\Gamma}$-ZSI has small inductor current stress. The working principle of ESL-${\Gamma}$-ZSI and comparison with the classical ZSI and SL- ZSI are analyzed in detail. The power loss comparison between ESL-${\Gamma}$-ZSI and Cuk converter is analyzed detailedly. Simulation and experimental results are given to demonstrate the operation features of the inverter.

Comparison of Main Circuit Type Characteristics of LED Driver for Output Ripple Reduction (출력 리플 저감을 위한 LED 드라이버의 주회로 방식 특성 비교)

  • Park, Dae-Su;Kim, Tae-Kyung;Oh, Sung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.491-499
    • /
    • 2019
  • Recently, there has been increasing demand for power quality in power supply devices. The IEC 61000-3-2 standard requires that the AC / DC power supply for lighting meet the specifications for the power factor (PF) and total waveform distortion (THD). In addition, advanced countries in Europe are regulating the ripple rate as 15 ~ 30% for the flicker phenomenon caused by the change in the amount of foot energy due to the change in current of the output terminal. Therefore, domestic standards and regulations are being updated. This study adopted the Flyback converter to satisfy the PFC standard, and has the circuit first and second insulation function. To reduce the low frequency ripple of the LED current, Flyback, Coupled Inductor, LC parallel resonance filter, LLC resonance filter, and Cuk were simulated by PSIM to mimic each LED driving circuit. A coupled LC resonant circuit with a coupled inductor on the primary side and LC resonance on the secondary side was also proposed for output side ripple reduction.